Irradiation of Living Cells with Single Ions at the Ion Microprobe SNAKE

Similar documents
object objective lens eyepiece lens

The scanning microbeam PIXE analysis facility at NIRS

COST MP0601 Short Wavelength Laboratory Sources

Visit for more fantastic resources. AQA. A Level. A Level Physics. Particle physics (Answers) Name: Total Marks: /30

Analysis of radioinduced DNA damages using Monte Carlo calculations at nanometric scale for different irradiation configurations

Chapter test: Probing the Heart of Matter

ACCELERATOR MASS SPECTROMETRY AT THE LUND PELLETRON ACCELERATOR

Coulomb crystal extraction from an ion trap for application to nano-beam source"

Application of NanoSIMS on Organo Mineral Structures

Effects of a static magnetic field on biological samples

Chapter 10: Wave Properties of Particles

IAP NAN of Ukraine activity in. Possible areas of cooperation in. Roman Kholodov, PICS Meeting, Basivka, Ukraine,

AP5301/ Name the major parts of an optical microscope and state their functions.

Progress in measuring GMR in unstable nuclei: Decay detector calibration and inverse reaction experiment. J. Button, Y.-W. Lui, and D.H.

Optical and THz investigations of mid-ir materials exposed

Energy Dependence of Biological Systems Under Radiation Exposure

Light ion recoil detector

The KATRIN experiment

MIDTERM 3 REVIEW SESSION. Dr. Flera Rizatdinova

In a particular investigation the atomic spacing of the crystal is m and the electrons are accelerated through 3000 V.

Markus Roth TU Darmstadt

Structure of MLL Tandem operation Experiments

MODULE 2 : FOUNDATIONS IN BIOLOGY

Light element IBA by Elastic Recoil Detection and Nuclear Reaction Analysis R. Heller

Workshop on Biomedical Applications of High Energy Ion Beams

Atomic and molecular interactions. Scanning probe microscopy.

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Depth profiles of helium and hydrogen in tungsten nano-tendril surface morphology using Elastic Recoil Detection

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

Secondary ion mass spectrometry (SIMS)

Assembly and test runs of decay detector for ISGMR study. J. Button, R. Polis, C. Canahui, Krishichayan, Y. -W. Lui, and D. H.

Scanning Electron Microscopy

Emphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)

Solution to the ion feedback problem in Hybrid Photon Detectors and Photo Multiplier Tubes a

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Neutron Imaging at Spallation Neutron Sources

r1 (D) r 2 = 2 r 1 (E) r 2 = 4r 1 2

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Introduction into Positron Annihilation

PoS(Bormio2012)013. K 0 production in pp and pnb reactions. Jia-Chii Berger-Chen

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Characterization of heavy charged particle fields using fluorescent nuclear track detectors

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

M. Werner, E. Altstadt, M. Jungmann, G. Brauer, K. Noack, A. Rogov, R. Krause-Rehberg. Thermal Analysis of EPOS components

General Physics (PHY 2140)

General Physics (PHY 2140)

Bi β + Po Bismuth-214 is radioactive. It has a half-life of 20 minutes. (a) The nuclide notation for bismuth-214 is Bi.

Feasibility Studies for the EXL Project at FAIR *

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

SPACE CHARGE EFFECTS AND FOCUSING METHODS FOR LASER ACCELERATED ION BEAMS

Microscopy, Staining, and Classification

Fadei Komarov Alexander Kamyshan

Higher Physics. Particles and Waves

Energetic neutral and negative ion beams accelerated from spray target irradiated with ultra-short, intense laser pulses

Improvement of Spatial Resolution by Selfconsistent Full Muon Track Reconstruction in Gaseous Detectors

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Nuclear Astrophysics II

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

DR KAZI SAZZAD MANIR

Available online at ScienceDirect. Energy Procedia 71 (2015 ) Yokohama, Kanagawa, Japan

Interactions of Particulate Radiation with Matter. Purpose. Importance of particulate interactions

N NBI DEVELOPMENT STATUS IN KURCHATOV INSTITUTE

Scanning Force Microscopy

U n 3 n Ba Kr (D) Br (C) Kr (B) Rb (E) 94 37

PHITS calculation of the radiation field in HIMAC BIO

CONCEPT MAP ATOMS. Atoms. 1.Thomson model 2.Rutherford model 3.Bohr model. 6. Hydrogen spectrum

BIOLOGY. Chapter 10 CELL REPRODUCTION PowerPoint Image Slideshow

Developments of the RCNP cyclotron cascade

2. Determine the excess charge on the outer surface of the outer sphere (a distance c from the center of the system).

State the main interaction when an alpha particle is scattered by a gold nucleus

Transmission Electron Microscopy

TEST BANK FOR PRESCOTTS MICROBIOLOGY 9TH EDITION BY WILLEY SHERWOOD WOOLVERTON

The heavy ion irradiation facility at KVI-CART

Outlook: Application of Positron Annihilation for defects investigations in thin films. Introduction to Positron Annihilation Methods

PARTICLE ACCELERATORS

arxiv:physics/ v2 [physics.ins-det] 18 Jul 2000

General Physics II Summer Session 2013 Review Ch - 16, 17, 18

Lecture 2: Quantum Mechanics and Relativity

in Si by means of Positron Annihilation

The Discovery of the Cell

15 Physics of Biological Systems

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

8.1 Life is cellular

The Groningen Cyclotron at Demokritos Athens

Spin-resolved photoelectron spectroscopy

AMOR the time-of-flight neutron reflectometer at SINQ/PSI

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

A graph of intensity of light incident on photo paper.

Lecture 32 April

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Fundamental Forces. Range Carrier Observed? Strength. Gravity Infinite Graviton No. Weak 10-6 Nuclear W+ W- Z Yes (1983)

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Interface (backside) & Extraction Lens

High-Resolution. Transmission. Electron Microscopy

Applications of scattering theory! From the structure of the proton! to protein structure!

Test Simulation of Neutron Damage to Electronic Components using Accelerator Facilities

A) n L < 1.0 B) n L > 1.1 C) n L > 1.3 D) n L < 1.1 E) n L < 1.3

It helps scientists understand the workings of the human body and of other animals and plants

Transcription:

Vol. 109 (2006) ACTA PHYSICA POLONICA A No. 3 Proceedings of the XL Zakopane School of Physics, Zakopane 2005 Irradiation of Living Cells with Single Ions at the Ion Microprobe SNAKE A. Hauptner a, T. Cremer b, M. Deutsch c, S. Dietzel b, G.A. Drexler c, C. Greubel a, V. Hable d, R. Krücken a, R. Löwe c, H. Strickfaden b, G. Dollinger d and A.A. Friedl c a Physik Department E12, Technische Universität, München, Germany b Department Biologie II, Ludwig-Maximilians-Universität München, Germany c Strahlenbiologisches Institut, Ludwig-Maximilians-Universität München, Germany d Institut für Angewandte Physik und Messtechnik (LRT 2) Universität der Bundeswehr, München, Germany The irradiation setup at the ion microprobe SNAKE is used to irradiate living cells with single energetic ions. The irradiation accuracy of 0.55 µm and respectively 0.40 µm allows to irradiate substructures of the cell nucleus. By the choice of ion atomic number and energy the irradiation can be performed with a damage density adjustable over more than three orders of magnitude. Immunofluorescence detection techniques show the distribution of proteins involved in the repair of DNA double-strand breaks. In one of the first experiments the kinetics of appearance of irradiation-induced foci in living HeLa cells was examined. In other experiments a new effect was detected which concerned the interaction between irradiation events performed at different time points within the same cell nucleus. PACS numbers: 29.27.Eg, 61.80.Jh, 87.16.Sr, 87.50.Gi 1. Introduction The ion microprobe SNAKE (superconducting nanoprobe for applied nuclear (Kern) physics experiments) enables to focus light and heavy ions delivered by the 14 MV Munich tandem accelerator. It is therefore a versatile instrument for the analysis and modification in material and biological sciences. One main application up to now is the three-dimensional hydrogen microscopy with sub-ppm detection limit [1]. Other current activities at the ion microprobe SNAKE concentrate on cell irradiation with single ions [2]. The relevant quantity for the damage (273)

274 A. Hauptner et al. Fig. 1. Relationship between ion velocity and energy deposited in a cell nucleus per single ion hit. The continuous line sections mark the respective energy regions provided by the Munich 14 MV tandem accelerator. induced in a living cell is the linear energy transfer (LET) value, which depends on atomic number and energy of the ion. Calculations of LET values were done using SRIM2003 software [3] assuming cell nuclei consisting of water. In Fig. 1 the corresponding relationship for a number of different ions is shown as well as the sections (= continuous line sections) supported by the 14 MV Munich tandem accelerator. It is evident that a variation of LET values over more than three orders of magnitude is possible, thus making cell irradiation experiments attractive. 2. Experimental technique In order to focus the ion beam to a submicron beamspot, the ion microprobe SNAKE consists of a precision slit system and a superconducting magnetic lens Fig. 2. Ion beam preparation and transport at the ion microprobe SNAKE.

Irradiation of Living Cells with Single Ions... 275 (Fig. 2). The object micro-slits define the object for the ion-optical transformation and have an opening of 20 µm in x- and respectively 10 µm in y-direction. The divergence slits located at a distance of about 5 m determine the aperture of the ion beam and have an opening of typically 60 µm in both directions. The transmission through the whole micro-slit system amounts to less than 10 8, leading to a particle rate of a few hundreds per second. Due to the ion-optical geometry the superconducting lens provides a focussing action with demagnification factors of 88 in x- and 24 in y-direction. Thus a beam spot size well below 0.5 µm can be achieved. An electrostatic deflection system mounted in front of the magnetic lens allows to scan the ion beam at the focal plane without moving the target mechanically. In order to prepare single particles an electrostatic chopper system in front of the divergence slits acts as a fast beam shutter triggered by the hit signal from an ion detector at the target. The cells to be irradiated are grown on a 6 µm thick mylar foil in a container made of stainless steel. Another 6 µm mylar foil acting as cover foil seals this cell chamber. During irradiation experiments the container is filled half with culture medium and put upright into the focal plane of the ion microprobe SNAKE. As can be seen in Fig. 3 the ion beam exits the vacuum of the beam transport system through a 7.5 µm thick Kapton foil which is in direct contact to the cell carrier foil from behind. Thus beam spot broadening by angular straggling effects can be minimized. The particle detector is mounted on the turret of an optical microscope situated behind the cell chamber. With the aid of this microscope the ion beam can be focussed during beam preparation and the cells can be observed before and after the irradiation procedure. To ensure proper operation of the irradiation setup and to obtain a measure for the irradiation resolution nuclear track detectors were irradiated using 100 MeV O ions. Figure 4 shows an irradiated matrix pattern with a pitch size of 5 µm. From the deviations between actual hit position and ideal hit position a resolution of 0.55 µm (FWHM) in x- and 0.40 µm (FWHM) in y-direction could be determined. Fig. 3. Cell container in irradiation position. During irradiation the microscope objective is replaced by a particle detector.

276 A. Hauptner et al. Fig. 4. Left side: irradiation test with single 100 MeV 16 O ions using nuclear track detector foils. Right side: the irradiation resolution was determined to 0.55 µm (FWHM) in x- and respectively 0.40 µm (FWHM) in y-direction. Fig. 5. Optical micrograph of a HeLa cell nucleus irradiated by two single 100 MeV 16 O ions. The foci show the distribution of immunostained 53Bp1 protein. The analysis of the irradiated cells is done by immunostaining techniques. For that purpose antibodies are allowed to enter the nuclei of the fixed cells. In a two step process, first primary antibodies bind specifically to selected proteins involved in the repair of DNA double-strand breaks (DSBs) before secondary antibodies labelled by a fluorescent dye bind to the first ones. In Fig. 5 an example of a cell nucleus irradiated by two single 100 MeV oxygen ions and prepared for 53Bp1 repair protein detection is shown. The corresponding foci clearly are visible. Nuclear DNA is counterstained with Dapi.

Irradiation of Living Cells with Single Ions... 277 3. Results In order to study the spatiotemporal dynamics of DNA DSB repair processes, living HeLa cells were irradiated using a line pattern consisting of single 100 MeV O ion hits separated by 1 µm in x- and 6 µm in y-direction. Several cell samples thus were irradiated and incubated afterwards for different time spans where repair could take place. Figure 6 shows two examples with incubation time of 0.5 hour and respectively 15 hours prepared for γh2ax detection. By using ROOT -software package [4] the development of foci size and position in time was evaluated [5]. With increasing incubation time the foci positions showed an Fig. 6. HeLa cells irradiated by a line pattern consisting of single 100 MeV 16 O ion hits. The time span between irradiation and observation was 0.5 hour (left side) and respectively 15 hours (right side). One can see an increased scatter of foci after the long time span. Fig. 7. Optical micrographs of irradiated HeLa cells showing competition effect in the distribution of 53Bp1 protein. Left side: cell nuclei with a time span of 15 min between first and second irradiation show 53Bp1 signal from all irradiation events. Right side: in cell nuclei with a time span of 45 min between the two irradiations the 53Bp1 signal is inhibited at the second irradiation due to the first irradiation (horizontal lines), while the cell nuclei only exposed to the second irradiation show clearly detectable 53Bp1 signal (vertical lines in the lower part of the image).

278 A. Hauptner et al. increasing scatter around the irradiated line compatible with a diffusion process. The foci size exhibited a more complex time behaviour, consisting of an initial increase and a following decrease after about 0.5 hour at the edge of the cell nucleus and respectively 2 hours at the centre of the cell nucleus. In another type of experiments a potential interaction between irradiation events separated in time within one cell nucleus was investigated. HeLa cells were irradiated twice with 100 MeV O ions forming defined irradiation patterns, so that foci formed after the first and after the second irradiation could be distinguished. We observed an inhibition of 53Bp1 protein accumulation after the second irradiation event in cells which were pre-irradiated about 45 min before. This effect can be seen on the right side of Fig. 7, where fluorescence signal from vertical line irradiation (= second irradiation event) is lacking in those cells where a horizontal line irradiation (= first irradiation event) was performed (upper part of the image), while it is clearly detectable in cells that were not pre-irradiated (lower part). This effect may be due to limited resources of 53Bp1 protein within the cell nucleus so that damage sites stand in competition for the available protein. References [1] P. Reichart, G. Datzmann, A. Hauptner, R. Hertenberger, C. Wild, G. Dollinger, Science 306, 1537 (2004). [2] A. Hauptner, S. Dietzel, G.A. Drexler, P. Reichart, R. Krücken, T. Cremer, A.A. Friedl, G. Dollinger, Radiat. Environ. Biophys. 42, 237 (2004). [3] J.F. Ziegler, J.P. Biersack, http://www.srim.org. [4] ROOT (An Object-Orientated Data Analysis Framework), http://root.cern.ch. [5] V. Hable, Diploma thesis, TU München, Physik Department, 2004.