WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Similar documents
WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

WS-7059U Wireless 433 MHz Temperature Station. Instruction Manual

WS-7391U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual

WS-7095U Wireless 433 MHz 24 Wall Hanging Wireless Weather Center. Instruction Manual

WS-7168U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual

Wireless Weather Station. Instruction Manual

The Weather Station FEATURES:

QUICK SET UP MANUAL WEATHER CENTER

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

WIRELESS 868 MHz WEATHER STATION Instruction Manual

Contents. English 1. French 56. Spanish

WS-9018U Wireless Weather Station. Instruction Manual

WS-9043U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual

FEATURES: The Weather Station

WS WEATHER CENTER Instruction Manual

Wireless Color Forecast Station Model: K86319

PROFESSIONAL WEATHER CENTER WS-1611 PROFESSIONAL WEATHER CENTER. This product offers: Table of Contents. Operation Manual FEATURES: Instruction Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

FEATURES: The Weather Station

What is the maximum distance I can have the remote sensors from the display?

WS-9035U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual

Wireless Weather Station Instruction Manual

WEATHER STATION Instruction Manual

CONTENTS. La Crosse Technology, Ltd. Page 1

WS-9016U Wireless 433 MHz Radio-controlled Sun/Moon Weather Station. Instruction Manual

XR Analog Clock - Manual Setting Model Troubleshooting Guide

SUN/MOON WEATHER STATION

Today s Weather 24 Hour Forecaster

Weather Station Model WS-9057U

U.S. Atomic Clock & Weather Station. Instruction Manual

Hadrons Desktop U.S. Atomic Clock & Weather Station

868MHz WEATHER STATION Instruction Manual

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

WIRELESS COLOR WEATHER STATION MODEL B

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Professional Wind Station

Quick Reference Guide

Congratulations on purchasing this WS1516IT Professional Weather Station.

Vantage PRO2 Quick. Reference Guide

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

To Set Time: Turn the set knob on back of the clock movement in either direction.

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue.

TOUCH SCREEN WEATHER STATION MODEL WS-3650

IR/Thermistor Pen. Instruction Manual

Fischer Instruments Stainless Steel Barometer User Manual

TG646 WEATHER STATION

WeatherHub2 Quick Start Guide

TABLE OF CONTENTS TABLE OF CONTENTS. summit/altitech 2. english. 2english

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

WIRELESS PROFESSIONAL COLOR WEATHER STATION & PHOTO ALBUM WITH 7 TFT SCREEN

O P E R A T I N G M A N U A L

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Speedtech Deerhunter s EDGE TM Model HE-1. Speedtech ECO EDGE TM Model EE-1. User s Manual

Digital Multi-Day Soil Temperatures Protocol

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Must Read Before Installation TadPoleTM Safety and Warnings

A clock designed in close consultation with people living with Dementia.

Wireless Weather Station

CONTENTS. Power Requirements... 8

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Assembly and Operation Manual. April 2016

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

LEAPERS, INC. RED/GREEN DOTS

WS-9020U 915MHZ INTELLIGENT WEATHER STATION Instruction Manual

WD-3102U 4 DAY INTERNET POWERED WEATHER STATION Owner s Manual

Dual laser + type K thermometer INFRARED THERMOMETER

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

CABLE FREE WEATHER STATION

C F AQ S C84612 FAQS Batteries Weather Station Factory Restart Quick Connect Remote Sensors Wind Sensor Wireless Rain Sensor

alterra/aerial 2 english english

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

B Left-hand case side (x1) F

BIOS. Weather. 266BC Wireless Wind Chill and Humidex Thermometer. Thermomètre sans fil pour indices de refroidissement éolien et humidex

product manual H-3220A Benkelman Beam

6 + WARNING: CHOKING HAZARD - Small parts/small ball(s). Not for children under 3 years.

WD DAY INTERNET POWERED WEATHER STATION Owner s Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

14 ULTRATOMIC WALL CLOCK

WeatherHawk Weather Station Protocol

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Training Guide. Coastal Environmental Systems, Inc.

Home Weather Station (HWS) Instruction Manual Table of Contents

Rain Collector (# 7852 & 7852M)

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

2 ACCESSING VARIOUS MODES

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

CA84688 FAQS TABLE OF CONTENTS

FAQS. La Crosse Technology, Ltd. Page 1

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

InfraRed Thermometer with Laser Pointer

WA-1240U 4 DAY INTERNET POWERED TALKING WEATHER STATION Owner s Manual

Transcription:

WS-7038U Wireless 433 MHz Miniature Rain Monitor Instruction Manual

TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 Quick Set-Up Guide 3 Detailed Set-Up Guide Battery Installation 4 Program Mode Function Buttons 5 Time Setting 5 Date Setting 5 Weekday Setting 6 Rain Alarm Setting 6 Resetting Total Rain Amount 6 Features & Operations Bar Graph 7 Numerical Representation of the Bar Graph 8 Manual Reset of Rain Multiplicator 8 Complete Resetting of Precipitation Data 9 Reception Requirements 9 Icons 9 Mounting 10-11 Maintenance & Care 11 Troubleshooting 12 Specifications 13 Warranty Information 14-16 2

INVENTORY OF CONTENTS 1) WS-7038U Wireless Rain Monitor with table stand. (Figure 1). 2) TX5U Wireless Rainfall Transmitter: includes a base, rainfall collector, and two mounting screws. (Figure 2). 3) Instruction manual and warranty card. Figure 1 Figure 2 Function Buttons ADDITIONAL EQUIPMENT (not included) 1) Two fresh 1.5V AAA batteries. 2) Two fresh 1.5V AA batteries. 3) Flathead screwdriver. QUICK SET-UP GUIDE 1) Insert two AA batteries into the Rainfall Transmitter. 2) Insert two AAA batteries into the Rain Monitor. 3) Program settings. 4) Wait 15 minutes, or until the Rain Monitor has received signals from the Rainfall Transmitter. 5) Mount the units, ensuring they are sending and receiving signals. 3

DETAILED SET-UP GUIDE I) BATTERY INSTALLATION Note: Batteries will fit tightly. To avoid start-up problems make sure that the batteries do not spring free. A) RAINFALL TRANSMITTER 1. Remove the flat-head screw and battery cover, located on the underside of the base. 2. Observe the correct polarity, and install two AA batteries. 3. Make sure the rubber weather seal is in place and replace the battery cover and screw. 4. Separate the base by turning the rainfall collector in a counter-clockwise direction. Remove the tape from the teeter-totter. Replace the cover. B. RAIN MONITOR Battery compartment 1. Remove the battery cover on the backside of the unit. 2. Observe the correct polarity, and install 2 AAA batteries. 3. Replace the battery cover. Battery cover Teeter- Totter Note: After the batteries have been installed, the entire LCD (Liquid Crystal Display) will light up briefly, then the default settings will be initiated. Battery Compartment Battery Cover 4

PROGRAM MODE After the batteries have been installed the minute digits of the time display will flash, signaling that the program mode has been automatically entered. If no buttons are pressed, the digits will stop flashing after 50 seconds. To enter the programming mode (when not automatically entered) hold down the RAIN/SET button for 2 seconds the minute digits will flash. The Program Mode is laid out in a manner that allows you to program each function separately, or you can follow the instructions entirely to program the Rain Monitor. Complete programming is usually done for the initial set-up, and will require you to skip step 1 of programming sections II through VI. I) FUNCTION BUTTONS There are 2 function buttons located on the front of the Rain Monitor, and under the LCD screen. The function buttons are labeled: RAIN/SET, and HISTORY/+. See Figure 1. II) TIME SETTING 1) Hold down the RAIN/SET button for 2 seconds, or until the minute-digits flash. 2) Press the HISTORY/+ button to adjust the minutes. 3) Press the RAIN/SET button to confirm the minutes and to shift to set the hour. 4) The hour-digits should now be flashing. Press the HISTORY/+ button to adjust the hour. Note: An A (a.m.) or a P (p.m.) will appear to the right of the time display, set the time accordingly. 5) Press the RAIN/SET button to confirm the hour setting, and to advance to set the date. III) DATE SETTING 1) Hold down the RAIN/SET button for 2 seconds, press the RAIN/SET button 2 more times until the first digit of the date (the month) flashes (default is 1.1 ). 2) Press the HISTORY/+ button to adjust the month. 3) Press the RAIN/SET button to confirm the month, and to shift to set the date. 4) Press the HISTORY/+ button to adjust the date. 5) Press the RAIN/SET button to confirm the date, and to advance to set the weekday. 5

IV) WEEKDAY SETTING Note: The weekday is not represented alphabetically, it is represented numerically, with 1 equal to Monday, and 2 equal to Tuesday, etc. 1) Hold down the RAIN/SET button for 2 seconds, press the RAIN/SET button 4 more times until the weekday digit flashes (default is 1 ). 2) Press the HISTORY/+ button to adjust the weekday. 3) Press the RAIN/SET button to confirm the weekday digit, and to advance to set the Rain Alarm. V) RAIN ALARM SETTING Note: When the Rain Alarm is activated, the alarm will sound when rain is detected. The alarm will sound for approximately 150 seconds before automatically turning off. The alarm can also be turned off manually by pressing any button. If there is a break of no rain between two rain periods, the break must exceed 80 minutes for the alarm to sound. 1) Hold down the RAIN/SET button for 2-seconds, press the RAIN/SET button 5 more times until the default ALOFF flashes. 2) Press the HISTORY/+ button to adjust the alarm setting ALOFF or AL ON. 3) Press the RAIN/SET button to confirm the alarm setting, and to advance to Resetting the Total Rain Amount. VI) RESETTING THE TOTAL RAIN AMOUNT 1) Hold down the RAIN/SET button for 2-seconds, press the RAIN/SET button 6 more times until the numerical digits flash under the TOTAL heading. 2) Press the HISTORY/+ button to reset the total rain amount. 3) Press the RAIN/SET button to confirm, and to exit the program mode. Note: The total rain amount will constantly accumulate unless the Rain Monitor is reset, or the batteries are changed. 6

FEATURES & OPERATIONS I) BAR GRAPH The bar graph displays the rainfall history. As indicated by the appearance of the word HISTORY at the left-central area of the LCD screen. The horizontal axis measures the past time periods, with 0 representing the current day, week, or month and 6 representing the oldest information (6 days ago, 6 weeks ago, or 6 months ago). The graph reads from right to left. The vertical axis measures the rainfall in inches. The normal (default) measurement scale is {0, 0.1, 0.2, 0.3, 0.4, 0.5, 1, 2, 3, 4, 5, 10 inches}. If, within any selected time period (1 day, 1 week, 1 month), rainfall exceeds 20 inches the measurement scale automatically changes to {0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 100 inches}. The bar graph will display the rainfall history either by day, week, or month. To select which to display: 1. Press the HISTORY/+ button. The DAILY icon will shift and become the WEEKLY icon (appearing across the central position of the LCD). 2. Press the HISTORY/+ button to toggle through the WEEKLY, MONTHLY, and DAILY icons. If DAILY is selected, the graph will display the rainfall history for the past 6 days. The information that is displayed in column 0 (the right column) is renewed daily at midnight, and the information contained in the columns is shifted to the left. If WEEKLY is selected, the graph will display the rainfall history for the past 6 weeks. The information that is displayed in column 0 is renewed every Monday at midnight, and the information contained in the columns is shifted to the left. If MONTHLY is selected, the graph will display the rainfall history for the past 6 months. The information displayed in column 0 is renewed on the first day of every month, at midnight. The information contained in the columns is shifted to the left. 7

II) NUMERICAL REPRESENTATION OF THE BAR GRAPH The bar graph displays the columns sequentially from 0 to 6 until all columns are showing. Then they are hidden again, and the sequential display is repeated. It is possible to read each column one at a time, simultaneously displaying the numeric measurement for that column above the bar graph. For example, the weekly rainfall total from 3 weeks ago may be viewed. Also, the numeric data from each column will correspond to the preveouly selected history ( DAILY, WEEKLY, or MONTHLY ). To view individual totals from the last six periods: 1. Hold down the HISTORY/+ button for 2 seconds. The numeric data from column 0 should appear at the top of the LCD screen, with the RAINFALL icon displayed above the data. 2. Press the HISTORY/+ button again, column 1 will be highlighted, and the numeric data will be displayed above the bar graph. 3. Continue to press the HISTORY/+ button until the data from each column (0 through 6) has been displayed. 4. Pressing the HISTORY/+ button once more, after viewing the data from column 6, will exit this mode returning to normal operation. III) MANUAL RESET OF THE RAIN MULTIPLICATOR Note: The rain multiplicator is the amount of rain needed to tip the teeter-totter bucket (inside the rain gauge). The multiplicator is preset to a value of 105 (0.0105 inches per tip); this number produces the most accurate rainfall measurement. There is no need to manually set this number unless it has been changed. 1. Remove the batteries and wait 30 seconds. This will reset the 1-hour rainfall total, but the bar graph and other totals will remain. 2. Checking the polarity, install batteries. 3. During the brief 2 seconds that the LCD screen lights up, hold down the HISTORY/+ button, until 105 appears in the LCD (the 5 will be flashing). 4. If the multiplicator is not 105; use the HISTORY/+ button to to change the last digit to a 5. Press the RAIN/SET button to confirm and shift to the middle digit. 5. Press the HISTORY/+ button to change the middle digit, and press the RAIN/SET button to confirm and shift to the first digit. Repeat process for the first digit. 6. Press the RAIN/SET button to exit the Rain Multiplicator mode, and to enter the normal mode. Follow Program Mode for set-up proceedures. 8

IV) COMPLETE RESETTING OF PRECIPITATION DATA Note: The rain data held by the bar chart and other rain totals (excluding the 1-hour total) will be stored and displayed again, even after the batteries have been removed. Therefore it is necessary to apply the following instructions to reset the bar chart and other totals, if desired. 1) Enter the Rain Multiplicator mode as instructed in steps 1 through 3 of the Manual Reset of the Rain Multiplicator section above. 2) After setting the rain multiplicator, while the left digit is flashing, press the RAIN/SET button for 8 seconds. This will clear data, and reset it to 0. V) RECEPTION REQUIRMENTS The Rain Monitor receives data from the Rainfall Transmitter every 5 minutes, while the Rainfall Transmitter transmits data every 1 minute. Data is transmitted immediately after rain has been detected. If 3 transmission attempts are made and no data is received, --- will be displayed in the LCD. If this is the case, reset the Rain Monitor. A) RESETTING VI) ICONS 1) Remove batteries from the Rain Monitor and Rain Gauge. 2) Wait 30 seconds, or start-up and transmission problems may arise, then reinstall the batteries. 3) Follow Programming instruction. The Rain Monitor cannot receive data in the Programming Mode, nor during the numeric display of the bar chart. Reception is also interupted when a button is pressed, and will continue when the button is released. The transmission range is approximately 80 feet (25m) in open space. The surrounding environment and interference levels influence this transmission range. A) FLASHING RAIN CLOUD A flashing rain cloud appears in the upper right hand corner of the LCD screen, when the Rainfall Transmitter is accumulating rain and transmitting data. B) SATELLITE ICON The satellite icon appears above the right column of the bar graph, when the Rain Monitor is searching for a signal from the Rainfall Transmitter. 9

MOUNTING Note: Before permanently mounting, ensure that the Rain Monitor is able to receive signals from the Rainfall Transmitter at their desired location. Obstacles such as walls, concrete, and large metal objects can reduce the range. Place units in their desired location, and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception I) THE TX5U RAINFALL TRANSMITTER The Rainfall Transmitter can be mounted in two ways: simply placing it in a desired location, or mounting it to a surface with the provided screws. Ensure that the Rainfall Transmitter is completely horizontal and stable. 1) Rotate the rainfall collector separating it from the base. 2) There are two cylindrical holes in the base to guide the mounting screws. Place the base over a desired mounting surface. With a pencil, mark the mounting surface through the cylindrical holes. 3) Where marked, start the screws. 4) Place the base over mounting surface. Install screws through the cylindrical holes and into the started holes on the mounting surface. 5) Secure the screws, ensuring that no part of the base can lift off the mounting surface. 6) Remove the manufacture tape from the teeter-totter on the base. If this is not done there will be no way to measure rainfall, and no measurement will display on the Weather Center. 7) Place the rainfall collector onto the base. Place the 3 tabs (on the rainfall collector) into the tab slots (on the base) and turn counter-clockwise. 10

II) THE WIRELESS RAIN MONITOR The Rain Monitor can also be mounted in two ways: with the table stand or, on the wall with the use of a wall hanging screw (not included). A) USING THE TABLE-STAND 1. The Rain Monitor comes with the table stand already mounted. If you wish to use the table-stand all that is required is to place the Rain Monitor in an appropriate location. B) WALL MOUNTING 1. Remove the table stand. To do this, pull down on the stand from the rear and rotate forward. (Figure 3). 2. Fix a screw (not included) into the desired wall, leaving approximately 3/16 of an inch (5mm) extended from the wall. (Figure 4). 3. Place the Rain Monitor onto the screw using the hanging hole on the backside. Gently pull the Rain Monitor down to lock the screw into place. Figure 3 Figure 4 MAINTENANCE & CARE Extreme temperatures, vibrations, and shock should be avoided to prevent damage to the units. Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents they may mark and damage the displays and casings. Do not submerge in water. Immediately remove all low powered batteries to avoid leakage and damage. Replace with new batteries only, and of recommended size. Opening the casings invalidates the warranty. Do not try to repair the units. Contact La Crosse Technology for Repairs. 11

TROUBLESHOOTING Problem: The LCD is faint. Solution: 1) Replace batteries. Problem: OFL appears in LCD. Solution: 1) Follow Reset directions. (Total rainfall accumulation has exceeded 999.99in.) Problem: --- Appears in LCD (rain monitor has lost signal from gauge) Solution: 1) Follow reset directions. 2) Distance the Rain Monitor or Rainfall Transmitter at least 6 feet (2m) away from interfering sources on a 433 MHz signal (computers, TV sets, headphones, speakers, etc.). 3) Move receiver away from metal window frames. 4) Neighbors using 433 MHz devices can interfere also. Problem: Need to reset the bar graph (EEPROM Rain Monitor memory) Solution: 1) Remove batteries, and follow instructions in section III, under Features & Operations. Problem: Rainfall amount is not correct. Solution: 1) Manually change the rain multiplicator number to 105, following instructions in section II, under Features & Operations. Note: For any questions not answered, contact La Crosse Technology with the contact information found at the end of this instructional manual. 12

SPECIFICATIONS Recommended operating temperature: Rain Monitor: 32 F to 122 F (0 C to 50 C) Rainfall Transmitter: 32 F to 122 F (0 C to 50 C) Rainfall Totals: For the previous 6 days, 6 weeks, 6 months, plus current day, week, or month Data Check Intervals: Receiver checking interval: Every 5 minutes Rainfall Transmitter checking interval: Every minute if no rain, immediately when rain begins Transmission frequency: 433.92 MHz Maximum transmission range: 80 feet (25m) Power supplies (Alkaline battery recommended): Rain monitor: 2 x AAA, IEC LR3, 1.5V batteries Rainfall Transmitter: 2 x AA, IEC LR6, 1.5V batteries Dimensions (L x W x H): Rain monitor (without stand): 3.54 x 0.86 x 4.13in (90 x 22 x 105mm) Rainfall Transmitter: 5.19in diameter x 7.20in high (132mm diameter x 183mm high) 13

WARRANTY INFORMATION La Crosse Technology provides a 1-year warranty on this weather station. Contact La Crosse Technology immediately upon discovery of any defects covered by this warranty. Before sending the Weather Station in for repairs, contact La Crosse Technology. The Weather Station will be repaired or replaced with the same or similar model. This warranty does not cover any defects resulting from improper use, unauthorized repairs, faulty batteries, or the Weather Stations inability to receive a signal due to any source of interference. LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS WEATHER STATION. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDRE S REACH. This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you. For warranty work, technical support, or information contact La Crosse Technology 700 East Main Street Spring Grove, MN 55974 Phone: 507.895.7095 Fax: 507.895.8000 e-mail: support@lacrossetechnology.com (warranty work) sales@lacrossetechnology.com (information on other products) web: www.lacrossetechnology.com All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher. This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences. All trademarks and patents are acknowledged. 14