UPLC Method Development and Validation

Similar documents
A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Reversed Phase Solvents

Successfully Scaling and Transferring HPLC and UPLC Methods

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

LC and LC/MS Column Selection Flow Chart

Basic Principles for Purification Using Supercritical Fluid Chromatography

LC Technical Information

Developing Analytical Chromatographic Methods for Pharmaceutical Stability Investigations

penta-hilic UHPLC COLUMNS

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Validation of ACQUITY UPLC Methods

penta-hilic UHPLC COLUMNS

Routine MS Detection for USP Chromatographic Methods

ANALYSIS OF BASIC COMPOUNDS

Dilution(*) Chromatography

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

8. Methods in Developing Mobile Phase Condition for C18 Column

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Acclaim Mixed-Mode WCX-1

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Part 2. Overview of HPLC Media

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

for Acclaim Mixed-Mode WCX-1

Implementation of Methods Translation between Liquid Chromatography Instrumentation

Too Polar for Reversed Phase What Do You Do?

Packings for HPLC. Packings for HPLC

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

for Acclaim Mixed-Mode HILIC-1 Column

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

How proteins separate on reverse-phase HPLC

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Validated HPLC Methods

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Technical Guide Thermo Scientific Syncronis HPLC Columns

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Hypersil BDS Columns TG 01-05

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Comparison of different aqueous mobile phase HPLC techniques

LIQUID CHROMATOGRAPHY

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

1.7 m Fortis UHPLC Columns

Reversed Phase Chromatography: Mobile phase Considerations

UPLC for Synthetic Peptides: A User`s Perspective

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

LC-MS compatible Separation of the Fungicide Spiroxamine

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

2007 Waters Corporation. Application of UPLC to Peptide Mapping

Kromasil Eternity Designed for long life

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Epic Aromatic Selectivity

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Use of Ultra-High Performance LC-MS for Challenging Assays. David Browne, Laboratory Manager (LC-MS-MS), Covance Laboratories, Harrogate

Small Molecule Selectivity Sampler

Shodex TM ODP2 HP series columns

InertSustainSwift C8

Inertsil Technical Library

Method Development Kits

2010 Waters Corporation

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Optimisil HPLC & UPLC Column catalogue

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Liquid Chromatography

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

[ a ppl ic at ion no t e ]

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Transcription:

UPLC Method Development and Validation Rev. 2 2008 Waters Corporation

Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy across organization Method development is costly and time-consuming Desire to streamline processes to bring products to market faster Faster chromatographic methods will improve profitability 2008 Waters Corporation 2

UPLC Technology Can Streamline Method Development UPLC Technology enables faster method development Methods can be developed in a single work day! Systematic scouting protocol involving ph, organic and column chemistry High-resolution sub-2 µm column technology enables high resolution separations, faster Automated column and mobile phase selection 2008 Waters Corporation 3

Outline Approaches Towards Method Development Selectivity and Retention Tools Stationary Phase and Particle Substrate Solvent ph Method Development Strategy Applications Conclusions 2008 Waters Corporation 4

Approaches Towards Method Development Literature search, colleague, speculation? Stepwise iterative procedure Next step experimental design based on results from previous experiment Systematic scouting Evaluate ph, organic solvent and stationary phase Select best combination of those three Fine tuning/optimization (temperature, gradient slope) 2008 Waters Corporation 5

Desirable Information for Method Development Sample solubility Number of analytes How many peaks of interest are you trying to separate? Chemical structure(s) Functional groups; how the analytes differ Ionizable species? How will ph influence chromatography? Detection Type of detection that is required or possible? Concentration range and quantitative requirements Sample matrix effects 2008 Waters Corporation 6

Outline Approaches Towards Method Development Selectivity and Retention Tools Stationary Phase and Particle Substrate Solvent ph Method Development Strategy Applications Conclusions 2008 Waters Corporation 7

Selectivity Tools Solvent ph α Selectivity Column Chemistry -Ligand -Base particle 2008 Waters Corporation 8

Improving Resolution with Complementary Selectivities Physical Chemical 2008 Waters Corporation 9

Different Ligands: Different Selectivity Changes in hydrophobicity Longer alkyl chain will provide greater retention Changes in silanol activity Affect peak asymmetry and influences secondary interactions Changes in hydrolytic stability Longer column lifetimes with greater number of ligand attachment points to the particle surface Changes in ligand density Influences sample loadability 2008 Waters Corporation 10

BEH Chemistries of UPLC Technology BEH C 18 Trifunctionally Bonded C 18 First UPLC column choice Superior peak shape & efficiencies BEH C 8 Trifunctionally Bonded C 8 Wide ph range BEH Shield RP18 Monofunctionally bonded Embedded carbamate group Alternate selectivities BEH Phenyl Trifunctionally Bonded C 6 (Hexyl) Phenyl Unique combination of chemistry & particle Wide ph range BEH HILIC Unbonded, rugged BEH particle HILIC for very polar bases 1.7 µm 2.5, 3.5, 5, 10 µm Ease of Migration from HPLC to UPLC Simplified Purification and Isolation 2008 Waters Corporation 11

HSS Chemistries of UPLC Technology HSS T3 T3: Polar compound retention Aqueous-compatible C 18 chemistry Designed for maximum retentivity HSS C 18 High coverage, trifunctionally bonded C 18 chemistry Universal, high performance C 18 chemistry Proprietary endcapping for superior peak shape Silica particle performance HSS C 18 SB SB: Selectivity for Bases Non-endcapped: optimum silanophilic selectivities 2008 Waters Corporation 12

Challenges of Developing and Manufacturing UPLC Particles Developing UPLC particles requires: R&D scientists capable of synthesizing, sizing and evaluating prototype sub-2 µm chromatographic media Cutting-edge synthesis facilities capable of reliably and reproducibly producing commercial quantities of bulk materials UPLC particle requirements: Pressure tolerance Proper morphology High efficiency/mass transfer Advanced bonding and endcapping processes Additional requirements as compared to HPLC particles 2008 Waters Corporation 13

Two Rugged, Efficient UPLC Particles: van Deemter Curves (<500 MW) HETP (µm) 30 25 20 15 10 5 µm SunFire C18 3.5 µm SunFire C18 1.8 µm ACQUITY UPLC HSS T3 1.7 µm ACQUITY UPLC BEH C18 5 0 Flow rate (ml/min) 0 1 2 3 4 5 6 7 8 9 10 11 12 Linear Velocity [mm/s] 1.0 mm ID 0.04 0.07 0.11 0.14 0.18 0.21 0.25 0.28 0.32 0.35 0.39 0.42 2.1 mm ID 0.15 0.30 0.45 0.60 0.75 0.90 1.05 1.20 1.35 1.50 1.65 1.80 4.6 mm ID 0.70 1.40 2.10 2.80 3.50 4.20 4.90 5.60 6.30 7.00 7.70 8.40 2008 Waters Corporation 14

UPLC Particles and Chemistries Summary Launch Date Mar 2004 Mar 2005 Mar 2005 Mar 2005 Dec 2005 Sep 2006 Jun 2007 Jan 2008 - Used in following method development protocol 2008 Waters Corporation 15

ACQUITY UPLC Column Selection: Method Development Approach BEH C 18 Widest ph range for maximum selectivity BEH Shield RP18 Embedded polar group offers complementary selectivity vs. alkyl C 18 chemistries BEH Phenyl C 6 (Hexyl) Phenyl chemistry offers complementary selectivity to C 18 and Shield RP18 chemistries, especially for analytes with aromatic rings HSS T3 Polar compound retention and aqueous mobile phase compatibility 2008 Waters Corporation 16

Selectivity Scouting Protocol 2.1 x 50 mm, <2 µm ph 3, ACN ph 3, MeOH ph 10, ACN ph 10, MeOH ACQUITY UPLC BEH C 18 ACQUITY UPLC BEH Shield RP 18 ACQUITY UPLC BEH Phenyl ACQUITY UPLC HSS T3 Optimization 2008 Waters Corporation 17

Selectivity Tools Solvent ph α Selectivity Column Chemistry 2008 Waters Corporation 18

Selectivity Observations: Chemical Structures N O H 3 C N N CH 3 O CH 3 CH 3 Amitriptyline (B) m.w. 277.40 Imipramine (B) m.w. 280.40 Flavone (N) m.w. 222.24 Octanophenone (N) m.w. 204.31 O - OH CH 3 Cl O N + CH 3 O - O Na + HN Cl O - N + O 1-Pyrenesulfonic acid (A) m.w. 304.3 diclofenac (WA) m.w. 318.13 Dinoseb (A) m.w. 240.21 2008 Waters Corporation 19

Stationary Phase Selectivity: Basic and Neutral Compounds ACQUITY UPLC BEH C18 B1 B2 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 N1 ACQUITY UPLC BEH Shield RP18 B1 B2 N1 ACQUITY UPLC BEH Phenyl B1 B2 N1 ACQUITY UPLC HSS T3 B1 B2 N1 N2 N2 N2 N2 Acetonitrile ph 3.0 Test Probes: B1 imipramine B2 amitriptyline N1 flavone N2 octanophenone Small differences in stationary phase selectivity with acetonitrile, low ph 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 20

Stationary Phase Selectivity: Acidic Compounds ACQUITY UPLC BEH C18 A1 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Shield RP18 A1 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Phenyl A1 A2 A2 A3 A2 A3 A3 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Acetonitrile ph 3.0 Test Probes: A1 1-pyrenesulfonic acid A2 diclofenac A3 dinoseb Small differences in stationary phase selectivity with acetonitrile, low ph ACQUITY UPLC HSS T3 A1 A2 A3 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 21

Selectivity Tools Solvent ph α Selectivity Column Chemistry 2008 Waters Corporation 22

Solvent Properties Methanol Weaker eluent H-bonding solvent Acetonitrile Aprotic solvent Stronger eluent Lower viscosity 2008 Waters Corporation 23

Solvent Selectivity: Basic and Neutral Compounds Acetonitrile 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes Methanol N1 ACQUITY UPLC BEH Phenyl B1 B2 N2 N1 N2 B1 B2 Test Probes: B1 imipramine B2 amitriptyline N1 flavone N2 octanophenone Methanol is weaker elution solvent, resulting in greater retention for all analytes Greater retention of bases respective to neutral probes 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 24

Solvent Selectivity: Acidic Compounds Acetonitrile A1 ACQUITY UPLC BEH C18 A2 A3 Test Probes: A1 1-pyrenesulfonic acid A2 diclofenac A3 dinoseb 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes Methanol A1 A2 A3 Methanol is weaker elution solvent resulting in greater retention for all analytes Elution order change 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 25

Selectivity Tools Solvent ph α Selectivity Column Chemistry 2008 Waters Corporation 26

Effect of Mobile Phase ph Affects only analytes with ionizable functional groups Amines Carboxylic acids Phenols Some compounds contain one or more ionizable function Strongest selectivity effects can be caused by ph changes 2008 Waters Corporation 27

Reversed-Phase Retention Map: The Importance of Mobile Phase ph Retention Factor (k) 40 35 30 25 20 15 10 Acid Note: Retention of neutral analytes not affected by ph Increased acid retention Neutral Increased base retention 5 Base 0 0 2 4 6 8 10 12 ph HSS Silica ph Range BEH Hybrid Particle ph Range Neue et. al. American Laboratory 1999 (22) 36-39. 2008 Waters Corporation 28

ph Selectivity: Basic and Neutral Compounds ph 3.0 acetonitrile B1 ACQUITY UPLC BEH Phenyl N2 B2 N1 Test Probes: B1 imipramine B2 amitriptyline N1 flavone N2 octanophenone Neutrals unaffected by ph 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes ph 10.0 acetonitrile N1 B2 B1 N2 At alkaline ph, bases are in their un-ionized form, resulting in greater retention 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 29

ph Selectivity: Acidic Compounds ph 3.0 acetonitrile 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes ph 10.0 acetonitrile A1 A2 A3 A1 ACQUITY UPLC BEH C18 A2 A3 Test Probes: A1 1-pyrenesulfonic acid A2 diclofenac A3 dinoseb At acidic ph, acids are in their un-ionized form resulting in greater retention Same elution order Dramatic change in selectivity 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 30

Selectivity Tools: Combining Chemical Factors Solvent ph α Selectivity Column Chemistry 2008 Waters Corporation 31

Maximizing Selectivity Differences: Basic and Neutral Compounds ACQUITY UPLC BEH C18 N2 N1 B1 B2 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Shield RP18 N2 B1 B2 N1 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Phenyl N2 B1 B2 N1 Acetonitrile, ph 10.0 Test Probes: B1 imipramine B2 amitriptyline N1 flavone N2 octanophenone Small differences in stationary phase selectivity occur with un-ionized analytes and acetonitrile as organic modifier 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 CM, ESG 2008 Waters Corporation 32

Maximizing Selectivity Differences: Basic and Neutral Compounds ACQUITY UPLC BEH C18 N2 Methanol, ph 10.0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Shield RP18 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Phenyl N1 N1 N1 B1 B2 B1 N2 B2 N2 B1 B2 Test Probes: B1 imipramine B2 amitriptyline N1 flavone N2 octanophenone Large differences in stationary phase selectivity with un-ionized analytes and methanol as organic modifier 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 CM, ESG 2008 Waters Corporation 33

Maximizing Selectivity Differences: Acidic Compounds ACQUITY UPLC BEH C18 A1 A2 A3 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Shield RP18 A1 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Phenyl A1 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC HSS T3 A1 A2 A2 A3 A2 A3 A3 Acetonitrile, ph 3.0 Test Probes: A1 1-pyrenesulfonic acid A2 diclofenac A3 dinoseb Small differences in stationary phase selectivity with un-ionized analytes and acetonitrile as organic modifier 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 34

Maximizing Selectivity Differences: Acidic Compounds ACQUITY UPLC BEH C18 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes ACQUITY UPLC BEH Shield RP18 A1 A1 A2 A3 A3 A2 Methanol, ph 3.0 Test Probes: A1 1-pyrenesulfonic acid A2 diclofenac A3 dinoseb 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC BEH Phenyl 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 ACQUITY UPLC HSS T3 A3 A2 A1 A3 A1 A2 Large differences in stationary phase selectivity with un-ionized analytes and methanol as organic modifier 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Minutes CM, ESG 2008 Waters Corporation 35

Selectivity Observations Analytes in their un-ionized forms yield greater retention Methanol increases retention of all components compared to acetonitrile Large differences in selectivity are observed when change in ph alters charge state These four bonded phases yield similar results employing acetonitrile Largest selectivity differences between bonded phases occured with methanol as organic modifier and analytes in their un-ionized state 2008 Waters Corporation 36

Selectivity Summary Manipulation of parameters for method development remain the same, HPLC or UPLC separations Acetonitrile and methanol ph 3 and ph 10 BEH particle technology enables the exploration of ph extremes in method development Stability from ph 1-12 Under the conditions and analytes of this study, large selectivity differences occurred between bonded phases with Methanol as organic modifier Analytes in their un-ionized state Evaluation of data from the complete screening matrix was essential to fully understand the analytes chromatographic behavior Why UPLC technology for method development? 2008 Waters Corporation 37

Same Resolution and Selectivity with Increased Speed - Constant L/dp AU AU AU 0.20 0.10 0.00 0.00 2.00 4.00 6.00 8.00 Minutes 0.20 0.10 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 Minutes 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Minutes 4.00 5 µm 150 mm F = 200 µl/min Injection = 5.0 µl Rs (2,3) = 2.28 10.00 2.00 3.5 µm 100 mm F = 300 µl/min Injection = 3.3 µl Rs (2,3) = 2.32 2.5 µm 75 mm F = 500 µl/min Injection = 2.5 µl Rs (2,3) = 2.34 AU 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.80 1.00 Minutes 1.10 1.7 µm 50 mm F = 600 µl/min Injection = 1.7 µl Rs (2,3) = 2.29 2008 Waters Corporation 38

Develop Methods Faster with UPLC Technology: : Time Savings UPLC Gradient Conditions: Column Dimensions: 2.1 x 50 mm, 1.7 µm Flow Rate: 0.5 ml/min Gradient: Time Profile Curve (min) %A %B 0.0 95 5 6 5.0 10 90 6 Peak Capacity (P c ) = 150 Equivalent HPLC Gradient Conditions: Column Dimensions: 4.6 x 100 mm, 3.5 µm Flow Rate: 1.4 ml/min Gradient: Time Profile Curve (min) %A %B 0.0 95 5 6 15.0 10 90 6 Peak Capacity (P c ) = 150 P = 1 c + t g w 2008 Waters Corporation 39

Develop Methods Faster with UPLC: Time Savings versus 3.5 µm HPLC Column UPLC Method Development Protocol 2.1 x 50 mm, 1.7 µm, 0.5 ml/min ph 3/ acetonitrile Time Flow ramp 5 min Column conditioning (2 blank gradients) 11 min Sample injection (2 replicates) 11 min ph 3/ methanol Flow ramp 5 min Column conditioning (2 blank gradients) 11 min Sample injection (2 replicates) 11 min Column purge 6 min ph 10/ acetonitrile Flow ramp 5 min Column conditioning (2 blank gradients) 11 min Sample injection (2 replicates) 12 min ph 10/ methanol Flow ramp 5 min Column conditioning (2 blank gradients) 11 min Sample injection (2 replicates) Column purge 11 min 6 min 120 min SCOUTING TIME 2 Hours/ Hybrid column x 3 columns EQUIVALENT HPLC Method Development Protocol, 3.5 µm 4.6 x 100 mm, 3.5 µm, 1.4 ml/min ph 3/ acetonitrile Time Flow ramp 5 min Column conditioning (2 blank gradients) 37.7 min Sample injection (2 replicates) 37.7 min ph 3/ methanol Flow ramp 5 min Column conditioning (2 blank gradients) 37.7 min Sample injection (2 replicates) 37.7 min Column purge 20.56 min ph 10/ acetonitrile Flow ramp 5 min Column conditioning (2 blank gradients) 37.7 min Sample injection (2 replicates) 37.7 min ph 10/ methanol Flow ramp 5 min Column conditioning (2 blank gradients) 37.7 min Sample injection (2 replicates) 37.7 min Column purge 20.56 min 362.72 min SCOUTING TIME 6 Hours/ Hybrid column x 3 columns 1 Hour/ Silica column x 1 column TOTAL SCOUTING TIME 7 HOURS 3 Hours/ Silica column x 1 column TOTAL SCOUTING TIME 21 HOURS UPLC scouting 3X faster than 3.5 µm HPLC 2008 Waters Corporation 40

Outline Approaches Towards Method Development Selectivity and Retention Tools Stationary Phase Solvent ph Method Development Strategy Applications Conclusions 2008 Waters Corporation 41

Automated Method Development and Validation Automated Method Development ACQUITY UPLC Column Manager, 4-column selection device o Utilize 2.1 x 50 mm columns ACQUITY UPLC Binary Solvent Manager, solvent select valves o Utilize ph 3 and ph 10 buffers o Utilize methanol and acetonitrile Fast 5-minute gradient 5 90% B, Flow = 0.5 ml/min Automated Method Validation Empower 2 Method Validation Manager, streamlines method validation process 2008 Waters Corporation 42

Selectivity Scouting Protocol 2.1 x 50 mm, <2 µm ph 3, ACN ph 3, MeOH ph 10, ACN ph 10, MeOH ACQUITY UPLC BEH C 18 ACQUITY UPLC BEH Shield RP 18 ACQUITY UPLC BEH Phenyl ACQUITY UPLC HSS T3 Optimization 2008 Waters Corporation 43

Outline Approaches Towards Method Development Selectivity and Retention Tools Stationary Phase Solvent ph Method Development Strategy Applications Method Optimization Conclusions 2008 Waters Corporation 44

Illustrating the Method Development Approach As we go through the data for each separation, we should have some questions in mind to help select the best ph, organic solvent and column Do I need resolution of every peak or simply my main component? How much resolution do I need? How much retention do I need and what is the retention profile? What are the tailing factors? Do I want a gradient or isocratic method? Step 1: Review data and select ph Step 2: Review data and select organic solvent and column Step 3: Optimize/fine-tune separation 2008 Waters Corporation 45

Automated Method Development and Validation of Paroxetine and Related Compounds Method Development Use systematic screening protocol Paroxetine (API) concentration: 0.2 mg/ml in 50:50 MeOH:H 2 O Related compounds at 10% concentration of API for easy identification during scouting Method Optimization Related compounds at 0.1% concentration of API o Related compounds B, D, F and G Method Validation Empower 2 Method Validation Manager Paroxetine m.w. 374.8 2008 Waters Corporation 46

Stationary Phase Selectivity: Paroxetine AU AU AU AU 0.40 0.30 0.20 0.10 ACQUITY UPLC BEH C18 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 0.40 0.30 0.20 0.10 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 0.40 0.30 0.20 0.10 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 0.40 0.30 0.20 0.10 ACQUITY UPLC BEH Shield RP18 ACQUITY UPLC BEH Phenyl ACQUITY UPLC HSS T3 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 B D Paroxetine D B G B D Paroxetine G Paroxetine F F B GD F Paroxetine G F Methanol ph 3.0 Observation: Poor resolution of paroxetine and related compounds (RC) Action: Investigate high ph CM, ESG 2008 Waters Corporation 47

ph Selectivity: Paroxetine AU 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 Paroxetine B D G F ph 3.0 Methanol Observation: Better retention and resolution of API from RC due to neutral charge state of analytes at alkaline ph 0.40 0.35 0.30 0.25 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 Paroxetine ph 10 Methanol Actions: Select ph 10 due to better separation AU 0.20 0.15 0.10 0.05 B D G F Compare stationary phase selectivity with ph 10 buffer 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 CM, ESG 2008 Waters Corporation 48

Stationary Phase Selectivity: Paroxetine AU AU AU 0.40 0.30 0.20 0.10 0.00 0.40 0.30 0.20 0.10 0.00 0.40 0.30 0.20 0.10 0.00 ACQUITY UPLC BEH C18 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 ACQUITY UPLC BEH Shield RP18 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 ACQUITY UPLC BEH Phenyl B D G F 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 Paroxetine Paroxetine B D G F Paroxetine B D G F Methanol ph 10.0 Observation: Any column may provide successful separation Actions: Select ACQUITY UPLC BEH C18 Compare selectivity between organic modifiers CM, ESG 2008 Waters Corporation 49

Solvent Selectivity: Paroxetine AU AU 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0.40 0.35 0.30 0.25 0.20 0.15 Acetonitrile ph 10.0 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 Methanol ph 10.0 Paroxetine B D G F Paroxetine Observations: Methanol is weaker elution solvent resulting in greater retention Better resolution exhibited with acetonitrile as organic modifier Actions: Select acetonitrile as organic modifier 0.10 0.05 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 Minutes B D G F Optimize separation using appropriate concentration of RC CM, ESG 2008 Waters Corporation 50

Related Compounds at 0.1% Concentration of Paroxetine AU 0.10 0.08 0.06 0.04 B Paroxetine Related Compounds at 10% G F D 0.02 0.00 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes Observation: Inadequate resolution among paroxetine and related compounds B and D due to disparate levels of concentration 0.005 0.004 0.003 0.002 B Paroxetine Related Compounds at 0.1% Action: Optimize Separation AU 0.001 0.000-0.001 D G F -0.002-0.003 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes 2008 Waters Corporation 51

Factors that Control Retentivity and Selectivity: Optimization Tools Once the ph, mobile phase, and column are selected, the method can be fine-tuned and optimized Parameters for optimization Gradient slope Temperature 2008 Waters Corporation 52

Method Optimization: Gradient Slope Shallower gradient slope may improve resolution Decreasing gradient slope will decrease sensitivity Steeper gradient slope may compress the peaks and often reduce the resolution Increasing gradient slope will increase sensitivity Changing gradient slope is a balance between peak heights relative to resolution Changes in retentivity and selectivity 2008 Waters Corporation 53

AU AU Method Optimization: Gradient Slope 0.005 0.004 0.003 0.002 0.001 0.000-0.001-0.002-0.003 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes 0.008 0.007 0.006 0.005 0.004 0.003 B Paroxetine D B Paroxetine G ACQUITY UPLC BEH C18 D F 5 Minute Gradient 5%-90% 5 Minute Gradient 20%-90% 0.002 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes G F Acetonitrile ph 10.0 30 C Observations: Marginal improvement in separation of RC from parent compound with shallow gradient slope Action: Alter gradient endpoint to produce shallower slope CM, ESG 2008 Waters Corporation 54

Method Optimization: Gradient Slope AU AU 0.008 0.007 0.006 0.005 0.004 0.003 0.002 0.001 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes 0.008 0.007 0.006 0.005 0.004 0.003 0.002 B Paroxetine D G B F Paroxetine D 5 Minute Gradient 20%-90% 5 Minute Gradient 20%-65% G F Acetonitrile ph 10.0 30 C Observations: Resolution remains inadequate with shallow gradient slope Action: Investigate column temperature 0.001 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes CM, ESG 2008 Waters Corporation 55

Method Optimization: Influence of Temperature Reduced mobile phase viscosity Lower backpressure If flow rate is held constant Improve analyte diffusivity Higher optimal linear velocity Changes in retention and selectivity 2008 Waters Corporation 56

AU AU AU Method Optimization: Column Temperature 0.008 0.006 0.004 0.002 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 0.008 Minutes 0.006 0.004 0.002 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 0.008 Minutes 0.006 0.004 0.002 B B Paroxetine B Paroxetine D Paroxetine D G F D G F 30 C 45 C 60 C 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes G F Acetonitrile ph 10.0 Observations: Higher temperature improves separation of RC from paroxetine Peak shape improves as temperature increases Action: Select 60 o C for best resolution and peak shape CM, ESG 2008 Waters Corporation 57

Final Method: Paroxetine and Related Compounds at 0.1% 0.010 0.009 0.008 0.007 0.006 Paroxetine AU 0.50 0.40 0.30 0.20 0.10 0.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00 Minutes AU 0.005 B D G F 0.004 0.003 0.002 0.001 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 Minutes Compound USP Rs Related compound B Paroxetine 1.95 Related compound D 3.07 Related compound G 13.00 Related compound F 6.74 ACQUITY UPLC BEH C18 2.1 x 50 mm, 1.7 µm 20 mm ammonium bicarbonate, ph 10 60 o C 5 Min Gradient, 20%-65% acetonitrile F = 0.5 ml/min Inj. Vol. 4 µl UV @ 295 nm 2008 Waters Corporation 58

Analytical Method Validation 2008 Waters Corporation 59

Analytical Method Validation with Empower 2 Method Validation Manager 2008 Waters Corporation 60

Automated Method Validation Manager: Paroxetine Validation Results Parameter Acceptance Criteria Reported Value Pass/Fail Linearity R 2 > 0.995 Residuals < 2.0% RSD 0.9999 1.74% RSD Accuracy 80 120 % 97 102 % pass Intermediate Precision Variance Component < 10 %RSD Peak Area (Analyst, Instrument, Column) Analyst 1.33% RSD Instrument 7.72% RSD Column 0.00% RSD pass pass pass pass pass LOD of impurities Impurities 0.1% of active at 0.2 mg/ml 0.05% of active at 0.2 mg/ml (s/n 2.2 6.23) pass Method Robustness Peak Area Method Robustness Retention Time Variance Component < 2 %RSD Peak Area (Buffer strength, Additive Conc., Column Temperature) Variance Component < 5 %RSD Retention Time (Buffer strength, Additive Conc., Column Temperature, Flow Rate, Injection Volume) 0.06 1.64% RSD pass 0.00 2.57% RSD pass 2008 Waters Corporation 61

Method Development and Validation Timeline: Instrument Time UPLC Method Development and Validation Timeline 2.1 x 50 mm, 1.7 µm, 0.5 ml/min Screening Time 4 Columns, 2 Organics, 2 phs 7.0 hours Optimization Gradient Slope and Temperature Validation Accuracy, linearity, repeatability, Reproducibility, LOD/LOQ, Intermediate precision, robustness 1.7 hours 21.1 hours TOTAL TIME 29.8 HOURS 2008 Waters Corporation 62

Conclusions Achieve more resolution, faster by utilizing sub-2 µm UPLC columns Principles of method development remain the same Broad range of column selectivity to successfully develop methods efficiently BEH C 18, BEH Shield RP18, BEH Phenyl and HSS T3 UPLC Technology allows for efficient method development Systematic scouting protocol Automated column selection High resolution sub 2 µm column technology UPLC Technology and Empower 2 software can significantly improve laboratory productivity and compliance 2008 Waters Corporation 63

Acknowledgements Erin Chambers Diane Diehl Eric Grumbach Jeff Mazzeo Doug McCabe Pat McDonald Christopher Messina Damian Morrison Tom Wheat 2008 Waters Corporation 64

2008 Waters Corporation