PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. (Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard: ISO/IEC 17025:2005 This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communiqué dated April 2017): For PJLA: Dimensional, Mechanical, Electrical, Weighing Devices, Thermodynamic and Chemical Calibration (As detailed in the supplement) Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body s duty to observe and comply with the said rules. Initial Accreditation Date: Issue Date: Expiration Date: December 14, 2016 March 26, 2019 March 26, 2021 Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084 Accreditation No.: Certificate No.: 89052 L19-167 The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website: www.pjlabs.com Page 1 of 5
Dimensional Outside Micrometer FO 0.5 mm to 270 mm (1.18 + 5.13 x 10-2 L) µm Gage Blocks Class 0 Calipers FO 0.5 mm to 270 mm (16.85 + 1.58 x 10-2 L) µm UNE-306-80 Height Gage FO 0.5 mm to 270 mm (12 x 1.86 x 10-2 ) µm Block Master Clase 0 JIS B 7517 Micrometers Head FO 0.5 mm to 270 mm (1.18 + 5.13 x 10-2 L) µm Block Set Master Clase 0 UNE 82-306-80 Measuring Tape FO 1 mm to 1 000 mm 1.6 mm Master Rule JIS B 7516 Rules FO 10 mm to 1 000 mm (557.56 + 2.15L) µm Optical Reticle: Mitutoyo JIS B 7516 Digital Indicators FO 0.0005 in to 1 in (1.15 + 1.22 x 10-1 L) µm Mitutoyo udt -2 Dial Gage Tester ASME/ANSI B89.1.10M Mass, Force and Weighing Devices Balance FO Scales FO 1 mg to 200 g (Res.= 0.001 g) 0.01 kg to 100 kg (Res.= 0.01 g) 50 g to 1 000 kg (Res.= 0.05 kg) 500 g to 3 000 kg (Res.= 0.5 kg) (5.8 x 10-4 + 5 x 10-6 Wt) g Weight Set E2, NOM-010-SCFI / NMX-CH-9 (5.8 x 10-1 + 3 x 10-6 Wt) kg Mass Parallelepiped Class M1 NOM-010-SCFI / (2.9 x 10-2 + 6 x 10-6 Wt) kg NMX-CH-9 (2.9 X 10-1 + 4 x 10-6 Wt) kg Mechanical Pressure Gage FO 3 psi to 300 psi 0.34 % of the reading Pressure Calibrator Druck, DPI 610 Vacuum Meters FO -14 psi to 3 psi 0.25 psi ISO 3567 Transducers FO 3 psi to 300 psi 0.34 % of the reading Pressure Transmitter FO 3 psi to 300 psi 0.34 % of the reading Issue: 03/2019 This supplement is in conjunction with certificate # L19-167 Page 2 of 5
Thermodynamic Oven FO 20 ºC to 1 000 C 0.8 ºC Thermocouple Type S Muffles FO 20 ºC to 1 000 C 0.8 ºC and Multimeter Fluke 753 Hot Rooms FO 20 ºC to 100 C 0.8 ºC RTD Pt 100 and Cold Rooms FO -20 ºC to 20 ºC 0.8 ºC Multimeter Fluke 753 Bimetallic Thermometers FO 30 C to 600 C 1.2 ºC Oven: Fluke 9144B Glass Thermometers FO 30 C to 300 C 1.4 ºC ASTM E1 Pyrometers FO 100 ºC to 600 C 1.5 ºC Oven Fluke 9144 b Blackbody Comparison ASTM E 1256 Thermocouple Type J FO 0 C to 850 C 0.82 ºC RTD Pt100: EIM, Mod. Pt100 Thermocouple Type K FO 0 C to 850 C 0.82 ºC and Multimeter Fluke 753 Electrical Thermocouple Type B FO Thermocouple Type C FO Thermocouple Type E FO 600 C to 800 C 1.8 ºC Electrical Simulation of 800 C to 1 000 C 1.8 ºC Thermocouple Output Fluke 753 1 000 C to 1 550 C 3.6 ºC ANSI-C39.1 1 550 C to 1 820 C 3.6 ºC ASTM E230 0 C to 150 C 0.8 ºC 150 C to 650 C 1.8 ºC 650 C to 1 000 C 1.8 ºC 1 000 C to 1 800 C 3.6 ºC 1 800 C to 2 316 C 3.6 ºC -250 C to -100 C 0.8 ºC -100 C to -25 C 1.8 ºC -25 C to 350 C 1.8 ºC 350 C to 650 C 3.6 ºC 650 C to 1 000 C 3.6 ºC Issue: 03/2019 This supplement is in conjunction with certificate #L19-167 Page 3 of 5
Electrical Thermocouple Type J FO Thermocouple Type K FO Thermocouple Type L FO Thermocouple Type N FO Thermocouple Type R FO Thermocouple Type S FO Thermocouple Type T FO Thermocouple Type U FO -210 C to -100 C 0.8 ºC Electrical Simulation of -100 C to -30 C 1.8 ºC Thermocouple Output Fluke 753-30 C to 150 C 1.8 ºC ASTM E220 150 C to 760 C 3.6 ºC 760 C to 1 200 C 3.6 ºC -200 C to -100 C 0.8 ºC -100 C to -25 C 1.8 ºC -25 C to 120 C 1.8 ºC 120 C to 1 000 C 3.6 ºC 1 000 C to 1 372 C 3.6 ºC -200 C to -100 C 0.8 ºC -100 C to 800 C 1.8 ºC 800 C to 900 C 1.8 ºC -200 C to -100 C 0.8 ºC -100 C to -25 C 1.8 ºC -25 C to 120 C 1.8 ºC 120 C to 410 C 1.8 ºC 0 C to 250 C 0.8 ºC 250 C to 400 C 1.8 ºC 400 C to 1 000 C 1.8 ºC 1 000 C to 1 767 C 1.8 ºC 0 C to 250 C 0.8 ºC 250 C to 1 000 C 1.8 ºC 1 000 C to 1 400 C 1.8 ºC 1 400 C to 1 767 C 1.8 ºC -250 C to -150 C 0.8 ºC -150 C to 0 C 1.8 ºC 0 C to 120 C 1.8 ºC 120 C to 400 C 1.8 ºC -200 C to 0 C 0.8 ºC 0 C to 600 C 1.8 ºC Issue: 03/2019 This supplement is in conjunction with certificate #L19-167 Page 4 of 5
Chemical ph Meter F 4 ph 0.08 ph Reference Material 7 ph 0.08 ph NMX-CH-068 10 ph 0.08 ph 1. The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual measurement uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the CMC for the same calibration since capability and performance of the device being calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to some degree. 2. The laboratories range of calibration capability for all disciplines for which they are accredited is the interval from the smallest calibrated standard to the largest calibrated standard used in performing the calibration. The low end of this range must be an attainable value for which the laboratory has or has access to the standard referenced. Verification of an indicated value of zero in the absence of a standard is common practice in the procedure for many calibrations but by its definition it does not constitute calibration of zero capacity. 3. The presence of a superscript F means that the laboratory performs calibration of the indicated parameter at its fixed location. Example: Outside Micrometer F would mean that the laboratory performs this calibration at its fixed location. 4. The presence of a superscript FO means that the laboratory performs calibration of the indicated parameter both at its fixed location and onsite at customer locations. Example: Outside Micrometer FO would mean that the laboratory performs this calibration at its fixed location and onsite at customer locations. 5. Measurement uncertainties obtained for calibrations performed at customer sites can be expected to be larger than the measurement uncertainties obtained at the laboratories fixed location for similar calibrations. This is due to the effects of transportation of the standards and equipment and upon environmental conditions at the customer site which are typically not controlled as closely as at the laboratories fixed location. 6. The term L represents length in inches or millimeters as appropriate to the uncertainty statement. 7. The term Wt represents weight in pounds or grams (including SI multiple and submultiple units) appropriate to the uncertainty statement. Issue: 03/2019 This supplement is in conjunction with certificate #L19-167 Page 5 of 5