PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]

Similar documents
Introductory Remarks:

PLANNING EXPERIMENT (SECTION B)

THERMOCOUPLE CHARACTERISTICS TRAINER

INFRARED THERMOMETER Model : TM-959

EXPERIMENTAL SETUP AND PROCEDURE

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

PG-200/PG-208 PRESSURE GAUGES P G G P P

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

Automatic titrators, TitroMatic

Compact ph Measuring Instruments With Pro Engineering

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

INE-PHS-3E ph Meter Operating Manual

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Experiment A. Introduction to the Organic Laboratory and Characterization Techniques

1 Fig. 3.1 shows the variation of the magnetic flux linkage with time t for a small generator. magnetic. flux linkage / Wb-turns 1.

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC


Practical 1 Procedure Iron by Titrimetry

Dual laser + type K thermometer INFRARED THERMOMETER

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

# 12 ph-titration of Strong Acids with Strong Bases

Chemistry Instrumental Analysis Lecture 23. Chem 4631

WHAT ARE THE EFFECTS OF MOVING CHARGES?

Experiment 2 Deflection of Electrons

Jumbo Cross Beam Ionizer

Experiment C-15 Distillation - part 1

PREPARATIVE TASK GRAND PRIX CHIMIQUE PETNICA SCIENCE CENTER, VALJEVO, SERBIA 9 TH -14 TH OCTOBER 2017

Chapter 12 Tex-617, Determining Chloride in Concrete

Measurement and Lab Equipment Basics Guided Notes

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS

Thermal and electrical conductivity of metals

Using Conductivity to Find an Equivalence Point

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Teacher s notes 15 Temperature volume relationship in a gas (Charles law, Gay-Lussac s law)

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18)

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

National 5 Physics. Electricity and Energy. Notes

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

637. Thiamethoxam. HPLC method

THE CONSERVATION OF ENERGY - PENDULUM -

Aarson Scientific Works

CHEMICAL SEPARATION EXPERIMENT 2

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

STUD & TRACK ROLL FORMING MACHINE

Hess' Law: Calorimetry

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Commercial Chip - R3L 16Vdc to 5kVdc

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Measurements & Instrumentation. Module 3: Temperature Sensors

Thermochemistry/Calorimetry LEC Heat capacity of gases. What you need: What you can learn about. Principle and tasks

DIPLOMA IN ENGINEERING I YEAR II SEMESTER

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Medium Pressure Sensor Analog Output

Conductometric Titration & Gravimetric Determination of a Precipitate

FrelTec GmbH. Multilayer Chip Ferrite Bead SMD

Petrochemical. Transformer Oil Gas Analysis - TOGA

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

#13 ph-titration of Weak Acids with Strong Bases

LM35 Precision Centigrade Temperature Sensors

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

Elcometer 116C. Sling Hygrometer. Operating Instructions

5.37 Introduction to Organic Synthesis Laboratory

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

CHEM E7115 Experimental Assignments in Chemical Engineering Internal mass transfer in a heterogeneously catalyzed reaction

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Level 1 Physics, 2016

[Agilent Technologies] [Electrochemistry Products] Quick Reference

Unit 1. The Math of Chemistry

Acceleration/Velocity/Displacement VIBRATION METER

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

TOL-CFcPGKC. Lamp LED. Features. Dimensions. Chip Lens Color. Part Number. TOL-CFcPGKC AlGaInP Pure Green Water clear

CONSTANT PRESSURE CALORIMETRY: A STUDY OF GLYCINE PROTON-TRANSFER ENTHALPIES 1

Electric Fields and Equipotentials

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

Experiment Nine Thin Layer Chromatography

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

Experiment 6: Dehydration of 2-Methylcyclohexanol

Approximate Volatile Acids by Titration

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

FrelTec GmbH. Thick Film Chip Resistor SMD Low Ohm

Is There a Chemist in You?

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

One-hand ph/temperature measuring instrument

TEKS Physics, Beginning with School Year Correlation to CPO Science Link

PMLCAP. Polymer Multi Layer Capacitor Specification Sheet RUBYCON CORPORATION PML DIVISION. PMLCAP ST series RPR Rubycon PART No. Drawing No.

Determination of freezing points of pure substances with Cobra4 TEC

Transcription:

T.K.M. COLLEGE OF ARTS & SCIENCE KOLLAM, Kerala 6900, INDIA www.tkmcas.ac.in Tender No 20/FIST/ ITEMS PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]. Digital Magnetic Stirrer with Hotplate and temp. sensor-2 2. Digital Magnetic Stirrer with Hotplate-2 3. Electronic balance 4 digit- 4. Conductivity meter-2. Ultrasonic Bath- 6. ph meter- 7. Double distillation Unit- 8. Chromatographic Columns-Variable 9. UV lamp- 0. Silica Gel for Chromatographic Columns-. Thin Layer Chromatography kit- 2. UV Cabinet with dual UV Light- 3. Flash Chromatographic Columns-2 Contact Person for Technical Clarification Regarding Lab Equipments for Chemistry,. Dr. S. Anas, Assistant Professor, Department of Chemistry, E-mail: anas.tkmchem@gmail.com, Mobile: 944792664. 2. Dr. Sumalekshmi, Assistant Professor, Department of Chemistry, E-mail: sumees@gmail.com, Mobile: 9400744. To purchase tender form, please contact T.K.M. College of Arts and Science office. The soft copy of TENDER FORMS can be obtained by contacting T.K.M.C.A.S. Office/ Dr. S. Anas. In such cases separate DD for the cost of Tender forms and EMD drawn in favor of The Principal, T.K.M. College of Arts and Science, Kollam payable at SBT Bank Karicode (Branch), Kollam, Kerala should be send along with the Tender Document (The DD cover should be send via. registered post or speed post separately). Cost of Tender Form: Rs 200+ Rs. 48 EMD: Rs. 6,00/- Last Date of Sale of Tender Forms: 26/2/20 02:00 pm Last Date of Submission of Tenders: 26/2/20 04:00 pm Date of Opening Tender: 0/0/206 0:00 am at Conference room, T.K.M. College of Arts & Science, Kollam.

EQUIPMENTS TO BE PURCHASED UNDER FIST GRANT Sl.No Equipment Specification Digital Magnetic Stirrer with Hotplate and temp. sensor-2 No. O Heating temperature range 0-00 C Stirring quantity max. (H 2O) 0 Litres Heat control accuracy 0 ±K Fixed safety circuit 0 C Heat control LED Motor rating input W Motor rating output. W Speed range 00-00 rpm Stirring bar length max. 80 mm Heating rate ( l H 2O in H) K/min Set-up plate dimensions 80 x 80 mm Dimensions (W x H x D) 220 x 0 x 330 mm Voltage 230 / 20 / 00 V Frequency 0/60 Hz Power input 020 W 2 Digital Magnetic Stirrer with Hotplate-2 No. 3 Double distillation Unit & Accessories- Stirring quantity max. (H 2O)- Litres Motor rating input W Motor rating output. W Speed range 00-00 rpm Heat output 20 W Heating rate ( l H 2O in H) 2. K/min Heating temperature range 0-00 C Heat control LED Heat control accuracy 0 ±K Fixed safety circuit 0 C Set-up plate material ceramic Set-up plate dimensions 00 x 00 mm Dimensions (Wx H x D) 0 x 0 x 260 mm Permissible ambient temperature - 40 C Permissible relative humidity 80 % Voltage 230 / 20 / 00 V Frequency 0/60 Hz Power input 270 W Distillation unit should be made up of borosil glass. Borosilicate boiler with water leveler & Condenser Quartz Heater Horizontal or vertical Type tubes Dist. Water output Capacity :4Lt/hr. Electrical Requirements : 230 20 volts ph 6.9-7 Conductivity S/cm < x 0-6

Distillation Apparatus Power Supply should be automatic, the water level should not falls below the coil. The sensor rods are adjusted above heater levels. It should give buzzer sound alert or any other type indication in low water level. 4 6 Conductivity meter-2 Electronic balance 4 digit P H meter with electrode (Digital) 7 Ultrasonic Bath- Micro Controller based Conductivity-TDS Meter with cells (.0CC & 0.CC) and Temp. Probe Selectable Ranges(for Conductivity): 0-20 micro /Mhos,200 micro/mhos, 2 milli/mhos & 200 milli/mhos Measuring Accuracy: ±% of F.S in all ranges ± count LED display Conductivity cells : Cell Constant 0. &.0 Power requirement : 230V ± 0%, 0Hz single phase Standard Accessories including Conductivity cells, temperature probe, Stand and Clamp. Capacity : 220g Readability : 0.000g (0.mg) Tare Range : 220g Repeatability : < ± 0.000g Linearity : ± 0.0002g Pan Diameter : 90mm Dimensions : 340mm x 22mm x 340mm Minimum Sample Weight : 0mg LED display ph range 0 to 4.00 ph Repeatability ± 0.0 ph ± digit for ph 3 point calibration Resolution 0.00 ph, mv in mv mode Standardization range ± ph Millivolt range 0 to ±999 mv Temperature compensation -Auto Display : 3 /2- digit red LCD seven segment with automatic polarity and decimal point Polarization current :0 µa Recorder output : ± 0 mv/ ph in ph mode ± 0 mv/00 mv in mv mode Accessories: Combined electrode, Stand and clamp Tank Capacity : 2- Ltrs Ultrasonic Freq : 33 ± 7 KHz Ultrasonic Power effective: 30W, 60W Timer : Count down with digital display Input Supply : 230 V Cleaning tank made of cavitation-resistant material

Heater : With digital temperature controller. Tank Size: Approximate dimensions- 8" 4" 4". Tank internal dimensions -W / D / H (mm) 90 / 80 / 60 (minimum). Accessories: lid, basket and other items. No Chromatographic Columns-Variable Std pack size 2 3 300mm 00mm 00mm 4 Grey body / Grey collect and plunger 220 V Flask Chromatography Sprayers With Rubber Bulb No UV lamp Quantity Long wave (UV-A) and short wave (UV-C) complete with 2-watt white light bulb and ENF-280C lamp featuring 8-watt LW tube, 8-watt SW tube and filter assembly Dimension:.4L x 44.W x 24.8 cm H No Silica gel Quantity Silica gel 00-200 mesh for column, chromatography

Thin Layer Chromatography kit. Consists Of Applicator, Constructed To Draw Thin Uniform Layer Variable Form 0 To 2 MM. 2. Minimum Thickness Attainable 0. MM. Accurate Design Of The Applicator Gives No Trouble In Coating Number Of Plates At A Time. 3.It Is Made Of Aluminium In Proper Shape Of Feeler Gauge 4. Are Supplied To Facilitate The Setting Of Applicator Supplied With Drawing Board, Drying Rack, Spotting Guide, Developing Chamber, Capillary, Silica Gel, Glass Plates. No Cabinet with dual UV Light Quantity Specifications: Cabinet Should be made of mild steel sheet with powder coating. Viewing TLC plate under UV light should be possible. No Flash-chromatography Quantity Repl. column for flash-chromatography 2 Flash. chromatography replacement column For any clarification regarding tendering process kindly contact, Dr. S. Anas Assistant Professor in Chemistry Convener DST FIST Project T.K.M. College of Arts & Science Karicode 6900, Kollam Kerala, India Email anas.tkm@gmail.com Mobile: 944792664.