Nexera UC Unified Chromatography

Similar documents
Chromatography. Gas Chromatography

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Liquid Chromatography

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Basic Principles for Purification Using Supercritical Fluid Chromatography

Chiral Separation Using SFC and HPLC

COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

Supercritical Fluid Chromatography

for Acclaim Mixed-Mode HILIC-1 Column

High Performance Liquid Chromatography

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Open Column Chromatography, GC, TLC, and HPLC

penta-hilic UHPLC COLUMNS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

LIQUID CHROMATOGRAPHY

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

LC Technical Information

LC and LC/MS Column Selection Flow Chart

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

High Pressure/Performance Liquid Chromatography (HPLC)

Chapter content. Reference

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

High Performance Liquid Chromatography

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Chapter 29 Supercritical Fluid Chromatography and Extraction 29A Properties of supercritical fluids

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Shodex TM ODP2 HP series columns

penta-hilic UHPLC COLUMNS

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Characterization of Carbon SPE for the Extraction of Polar Analytes


Application Note. Authors. Abstract. Pharmaceuticals

Screening of pesticides in water using SPE on line

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

How proteins separate on reverse-phase HPLC

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Instrumental Chemical Analysis

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

8. Methods in Developing Mobile Phase Condition for C18 Column

Optical Isomer Separation Columns and Packing Materials

Principles of Gas- Chromatography (GC)

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

HPLC Background Chem 250 F 2008 Page 1 of 24

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Luminescence transitions. Fluorescence spectroscopy

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

CHEM 429 / 529 Chemical Separation Techniques

Introduction to Capillary GC

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Chromatographic Separation

Packings for HPLC. Packings for HPLC

Analytical Chemistry

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Gas Chromatography (GC)

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Dilution(*) Chromatography

UPLC Method Development and Validation

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

Cation Exchange HPLC Columns

FAQ's. 1 - Which column would be the most appropriate for my application?

Introduction to Capillary GC

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Chapter 31 Gas Chromatography. Carrier Gas System

Fast methods for the determination of ibuprofen in drug products

Determination of Volatile Substances Proof of Food Adulteration


Introduction to Chromatographic Separations

Reversed Phase Solvents

Volume 6, Issue 2, January February 2011; Article-015

Volatile organic compounds (VOCs):

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

GC Instruments. GC Instruments - Columns

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Transcription:

Nexera UC Unified Chromatography The latest addition to the chromatography toolbox Dr. Gesa J. Schad Shimadzu Europa GmbH

A brief history of SFC ϒ Late 1800 s: it was found that heavy, non-volatile organic compounds were surprisingly soluble in some inorganic gases above their critical point ( super -critical). 1957: first ideas to use such gases as a chromatographic mobile phase Acting as a solvent is a critical characteristic that differentiates the compressible mobile phase used in supercritical fluid chromatography (SFC) from gas chromatography (GC), where the mobile phase is considered to be an inert carrier Early 1990 s: - concentration of polar modifiers was shown to be the primary retention control variable when added to the CO 2 - pressure/density became a secondary control variable - use of additives allowed highly efficient elution of polar solutes, such as primary aliphatic amines modern SFC was born

Pressure [bar] What is SFC and how does it work Supercritical CO 2 is a fluid state of carbon dioxide where it is held at or above its critical temperature (31.1 C) and critical pressure (73.8 bar) 150 Supercritical CO 2 100 Liquid CO 2 Critical Point 50 Gaseous CO 2 10 20 30 40 Temperature [ C] Rule-of-thumb: any molecule that dissolves in methanol (or less polar solvents) is compatible with SFC CO 2 at its critical point is non-polar, solvent strength is increased by using a polar co-solvent When a co-solvent is introduced, the mobile phase is not truly supercritical, the terminology is used regardless

SFC vs. LC Equipment: HPLC / UHPLC SFC LC pump LC pump Controller Controller PDA detector BPR PDA detector CO 2 pump Autosampler direct injection Fixed loop injection (option) LC pump Autosampler Column oven Fixed loop injection Column oven

SFC vs. HPLC Similarities: RP-SFC, NP-SFC, IP-SFC and HILIC-SFC possible by changing polarity of stationary and mobile phase Organic modifiers and ionic additives can be used to adjust selectivity Packed column SFC is the most common methodology Silica based porous particles with various type of bonded phases are used for SFC separations Separations can be achieved isocratically or by using a solvent gradient

SFC vs. HPLC Advantages of SFC: Low viscosity of the mobile phase generates up to 5 times the linear velocity of RP-LC less pressure drop across the column Resolving power is ~ 5 x that of HPLC Superior to LC for chiral separations Complimentary chromatographic selectivity to RP-LC Green technique reduced organic solvent consumption High purity samples with little residual solvent obtained in preparative chromatography

SFE what is it and how does it work spco 2 has the transport capacity of a liquid, as the molecules are pressurized to give a fluid volume It has the mobility and penetrating power of a gas, as the molecules are capable of behaving independently spco2 can get into structures and surround molecules to be extracted using it s gas-like properties and carry those analytes out of the matrix using it s liquid like properties. solid liquid gas supercritical fluid

Nexera UC Features Fully automated online sample preparation and analysis Faster, more efficient analytical work flow Reduced quantitative error Less degradation of labile samples Multi sample extraction by automated vessel changer Max. 48 sample Flexible use as SFC or LC system Improved sensitivity due to low dead volume and low pulsation BPR

Nexera UC System Configuration SFC / LC UV System CO 2 Pump Modifier Pump Autosampler Column Oven UV BPR CO 2 Cylinder Modifier Solvent One Back Pressure Regulator after the detector No make-up pump needed Simple SFC / LC UV hybrid system

Nexera UC System Configuration SFC / LC switching system UV System CO 2 Pump Binary Gradient Pump (LC) Autosampler Column Oven UV BPR Modifier Pump CO 2 Cylinder Modifier Solvent One Back Pressure Regulator after the detector No make-up pump needed Simple SFC / LC UV hybrid system

SFC or LC analysis in one batch SFC 1 SFC LC LC 1 LC SFC SFC 2 SFC LC LC 2 Easy batch file creation for LC/SFC switching using the Method Scouting Software SFC LC switching method LC SFC is automatically inserted

SFC or LC analysis in one batch AU 2.0 1.0 0.0 Propranolol Indapamide Ibuprofen LC Mobile phase A : 0.1% Formic acid in H 2 O Mobile phase B : Acetonitrile Flow rate: 1 ml/min Gradient: 20 %B (0 min) 90 %B (2-3 min) Column: ShimPack XR-ODSⅡ 75 x 3.0 mm, 2.2 µm 0.0 0.5 1.0 1.5 2.0 2.5 min AU 2.0 1.0 Propranolol Indapamide Ibuprofen 0.0 0.0 0.5 1.0 1.5 2.0 2.5 min SFC Mobile phase A: CO 2 Mobile phase B: 0.1 % Ammonium formate in MeOH Flow rate: 1.5 ml/min Gradient: 5%B(0min) 90%B(2-3min) Column: ShimPack UC-RP 150 x 2.1 mm, 3 µm

Nexera UC System Configuration Online SFC PDA Scouting System Autosampler CO 2 Pump Modifier Pump PDA BPR CO 2 Cylinder Modifier Solvent Column Oven One Back Pressure Regulator after the detector Two ovens with column switching valves for fast column screening for method development

Method scouting option

Nexera UC System Configuration Online SFE SFC MS System Autosampler CO 2 Pump SFE Unit BPR Splitless MS CO 2 Cylinder Modifier Pump Modifier Solvent BPR Column Oven Make up Pump Make up solvent for ionization extraction vessel Additional Back Pressure Regulator to optimize SFE conditions Column switching valve for method development Make-up pump for ionization for MS detection

Extraction unit SFE-30A Extraction up to 80 o C Extraction vessels 0.2 ml or 5 ml

Large sample capacity Extraction Vessel Up to 48 samples can be automatically extracted and analysed by using the Rack Changer option

SFE sample preparation Homogenize Add absorbent Mix Fill extraction vessel Patented adsorbent effective for dehydration samples with high water content Spot the sample Cut DBS Put DBS in extraction vessel 0 2.5 5.0 7.5 10.0 12.5 min Extraction and analysis of 1 ppm phospholipid spiked into plasma on DBS

Sample preparation

Analysis of pesticides in spinach Online SFE-SFC: Extraction with CO 2 for 4 min (10 MPa, 40 o C) (0 2 min static + 2 4 min dynamic extraction) SFC Conditions: Column: Modifier: Inertsil ODS-EP HP, 4.6 250 mm 5 µm (GL Sciences Co.) Flow Rate: 3 ml/min Gradient: BPR: Detector: Make up: 0.1% w/v (16 mm) NH 4 OOCH in MeOH 0 % (4 min); 11 % (15 min); 30 % (18min); 40 % (18.1 to 21 min) 10 MPa LCMS-8050 operating a MRM method 0.1% w/v (16 mm) NH 4 OOCH in MeOH Flow Rate: 0.1 ml/min Online extraction Spinach (spiked 100ppb pesticides) Analysis 1 2 3 4 5 7 1. Sethoxydim (LC) 2. Chlorpyrifos (GC) 3. Piperonyl butoxide (GC) 4. Aminocarb (LC) 5. Chromafenozide (LC) 6. Captan (GC) 7. Endosulfan sulphate (GC) 6 0.0 20.0

Nexera UC Features High sensitivity detection Improved sensitivity due to low dead volume BPR Splitless injection into the MS without band broadening 300,000 Split injection (Split Ratio: Vent : MS = 8 : 2) 300,000 Splitless injection Reserpine 10 µg/l 200,000 x 5 200,000 100,000 0 Reserpine 10 µg/l 5 µg/l 0.5 µg/l 0.00 0.50 1.00 1.50 min 5 µg/l 100,000 0.5 µg/l 0 0.00 0.50 1.00 1.50 min BPR BPR Splitless MS Column Oven Make up Pump Split MS Column Oven Make up Pump Make up solvent Make up solvent

Nexera UC Features High sensitivity detection Concentrated sample due to evaporation of CO 2 after BPR 6000 5000 LC 6000 5000 SFC 4000 3000 x 6 4000 3000 2000 2000 1000 1000 0.0 0.0 0.0 0.5 1.0 1.5 min LC Conditions Column : FC ODS, 2.1 150 mm, 3um Mobile Phase A : 0.1% W/V Ammmonium Formate in MeOH Mobile Phase B : 0.1% W/V Ammmonium Formate in H 2 O B Conc. : 30% Flow Rate : 0.4 ml/min Detector : LCMS-8040 sample : prostaglandin 100 µg/l 0.0 0.5 1.0 1.5 min SFC Conditions Column : Inertsil Diol, 2.1 150 mm, 3 m Modifier : 0.1 %w/v ammmonium formate in MeOH Conc. : 20 % Flow Rate : 1 ml/min BPR : 10 MPa (50 ) Detector : LCMS-8040 sample : prostaglandin 100 µg/l

Application Analysis of coenzyme Q 10 in supplements Conventional Method: Coenzyme Q 10 is prone to oxidation OH O Solvent extraction: (sonication in EtOH) Oxidized coenzyme Q 10 O O O H O H Supplement Coenzyme Q 10 OH 10 O 10 Standard Coenzyme Q 10 Oxidized coenzyme Q 10 No oxidation with SFE 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 min Extraction with 5 % MeOH in CO 2 for 4 min Gradient: 5 %B (0 min 4 min for SFE) 5 % - 50 %B in 5 min SFE: Supplement Standard Reduced coenzyme Q 10 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 min

Application Extraction of polymer additives Conventional Method: 10 20 h soxhlet extraction SFE: 7 min CO 2 extraction Crushed polymer samples are filled in the extraction vessel After 7 min CO 2 extraction the sample is ready for SFC analysis mau 800 Irganox 1010 in Polypropylene sheet mau 800 Irganox 1010 in Polyethylene film 600 600 400 400 200 200 0 10.0 11.0 12.0 13.0 min 0 10.0 11.0 12.0 13.0 min

Application Cleaning validation Conventional Method: Sampling solvent extraction concentration HPLC analysis SFE-SFC: Sampling Swab is enclosed in the extraction vessel for SFE Spiked sample 200 µg of detergent Detergent (Alkylbenzene sulfonate) Blank 0 2.5 5.0 7.5 min

Application Chiral Method Scouting Dedicated Method Scouting Solution: Selection of up to 12 columns Solvent blending of modifier

Application Separation of indapamide enantiomers by method scouting 400 mau 0.0 5.0 Column: CHIRALPAK AD-H Modifier: Acetonitrile/ Methanol=7/3 Resolution = 2.66 (Rt =2.644)

Thank you for your attention!