Molecular Luminescence Spectroscopy

Similar documents
Classification of spectroscopic methods

Chapter 15 Molecular Luminescence Spectrometry

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Chapter 17: Fundamentals of Spectrophotometry

Chapter 17: Fundamentals of Spectrophotometry

Molecular Luminescence. Absorption Instrumentation. UV absorption spectrum. lg ε. A = εbc. monochromator. light source. Rotating mirror (beam chopper)

Reflection = EM strikes a boundary between two media differing in η and bounces back

Spectroscopy Problem Set February 22, 2018

PRINCIPLE OF ICP- AES

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Singlet. Fluorescence Spectroscopy * LUMO

A Fluorometric Analysis of Quinine in Tonic Water

Chapter 6 Photoluminescence Spectroscopy

27-1 (a) Resonance fluorescence is observed when excited atoms emit radiation of the same

C101-E145 TALK LETTER. Vol. 17

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chemistry Instrumental Analysis Lecture 3. Chem 4631

Introduction ENERGY. Heat Electricity Electromagnetic irradiation (light)

Ultraviolet-Visible and Infrared Spectrophotometry

MOLECULAR ABSORPTION METHODS

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

Chemistry 2. Molecular Photophysics

Wavelength λ Velocity v. Electric Field Strength Amplitude A. Time t or Distance x time for 1 λ to pass fixed point. # of λ passing per s ν= 1 p

LABORATORY OF ELEMENTARY BIOPHYSICS

Fluorescence Polarization Anisotropy FPA

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

PRINCIPLES OF AAS atomization flame furnace atomization absorption

Electromagnetic Radiation (EMR)

Introduction to Spectroscopic methods

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Ultraviolet-Visible and Infrared Spectrophotometry

What the Einstein Relations Tell Us

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

NPTEL/IITM. Molecular Spectroscopy Lectures 1 & 2. Prof.K. Mangala Sunder Page 1 of 15. Topics. Part I : Introductory concepts Topics

高等食品分析 (Advanced Food Analysis) I. SPECTROSCOPIC METHODS *Instrumental methods: 1. Spectroscopic methods (spectroscopy): a) Electromagnetic radiation

Analytical Spectroscopy Review

Lecture- 08 Emission and absorption spectra

Lecture 3: Light absorbance

Luminescence Spectroscopy Excitation is very rapid (10-15 s). Vibrational relaxation is a non-radiational process. It involves vibrational levels of

two slits and 5 slits

24 Introduction to Spectrochemical Methods

Skoog Chapter 7 Components of Optical Instruments

Skoog Chapter 6 Introduction to Spectrometric Methods

A Fluorometric Analysis of Quinine in Tonic Water

General Considerations 1

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Atomic Absorption Spectroscopy

Ch 313 FINAL EXAM OUTLINE Spring 2010

CHAPTER 13 Molecular Spectroscopy 2: Electronic Transitions

Department of Chemistry Physical Chemistry Göteborg University

Electronic Spectra of Complexes

Atomization. In Flame Emission

IR Spectrography - Absorption. Raman Spectrography - Scattering. n 0 n M - Raman n 0 - Rayleigh

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

Generation of light Light sources

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Chapter 4 Ultraviolet and visible spectroscopy Molecular Spectrophotometry

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Chem 321 Lecture 18 - Spectrophotometry 10/31/13

Fluorescence Excitation and Emission Fundamentals

Chap. 12 Photochemistry

Lecture 0. NC State University

Introduction to Fluorescence Spectroscopies I. Theory

Reference. What is spectroscopy? What is Light? / EMR 11/15/2015. Principles of Spectroscopy. Processes in Spectroscopy

2101 Atomic Spectroscopy

Excited State Processes

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Overview of Spectroscopy

25 Instruments for Optical Spectrometry

Chem Homework Set Answers

UV-VIS Spectroscopy and Fluorescence Spectroscopy (Part 2 of 2)

PART VI : MOLECULAR LUMINESCENCE SPECTROSCOPY (Recommendations 1985)

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Instrumental Chemical Analysis

Instrumental Chemical Analysis

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Photochemical principles

Assumed knowledge. Chemistry 2. Learning outcomes. Electronic spectroscopy of polyatomic molecules. Franck-Condon Principle (reprise)

Absorption spectrometry summary

Infrared Spectroscopy: Identification of Unknown Substances

Electronic Excitation by UV/Vis Spectroscopy :

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

PHOTOCHEMISTRY NOTES - 1 -

Spectroscopy and Chromatography

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006

Cork Institute of Technology. Summer 2005 Instrumental Analysis (Time: 3 Hours) Section A

Chem 434 -Instrumental Analysis Hour Exam 1

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

1. Photoreduction of Benzophenone in 2-Propanol

A Determination of DNA-DAPI Binding using Fluorescence Spectroscopy

Atomic Absorption Spectroscopy (AAS)

INSTRUCTOR S MANUAL MOLECULAR AND ATOMIC SPECTROSCOPY

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

Molecular spectroscopy

3 - Atomic Absorption Spectroscopy

Transcription:

Molecular Luminescence Spectroscopy In Molecular Luminescence Spectrometry ( MLS ), molecules of the analyte in solution are excited to give a species whose emission spectrum provides information for qualitative or quantitative analysis. There are three types of MLS : Fluorescence: excitation by absorption of photon, short-lived excited state (singlet), emission of photon. Phosphorescence: excitation by absorption of photon, long-lived. excited state (triplet), emission of photon. These two types are called photoluminescence where molecules are excited by absorption of electromagnetic radiation Chemiluminescence: no excitation source chemical reaction energy to excite molecule which emit radiation. These three methods will be the subject of this unit..

Fluorescence is important due to its inherent sensitivity which can be several orders of magnitude more sensitive than absorption methods. Another reason which adds to its importance is the specificity of fluorescence methods since, relatively, small margin of molecules fluoresce. When radiation of an appropriate wavelength is used to irradiate molecules in a sample, certain electronic transitions take place. As excited molecules return to the ground state they emit radiation of longer wavelength. The emitted radiation is referred to as fluorescence. The following Figure shows a description of absorption and emission phenomena and energy levels associated with these electronic transitions.

Electrons in the ground state (So) absorb energy from incident radiation and are excited to S1 or S2 excited states. Vibrational relaxation results in the return of the electron to lower vibrational level. Vibrational relaxation is a nonradiative deactivation process where excess energy is consumed as kinetic energy or heat. A second collisional deactivation process can take place and the electron returns to the ground state by a nonradiative deactivation process to So. The other possibility involves direct transition of the electron from the S1 excited state to So ground state and excess energy is emitted as photons at specific wavelengths called fluorescence. Electrons in the excited state can follow a third approach by changing their spin and transferring to the triplet state through a process known as intersystem crossing.

The path of the excited electron depends on several factors which will be mentioned shortly. An electron in the triplet state will surely exhibit a vibrational relaxation to the main triplet energy level. A second flip in spin is necessary for such an electron to transfer to the ground state by one of two mechanisms. The first involves emitting a photon at a specific wavelength (phosphorescence) or non-radiative deactivation. Some molecules show a different behavior where an electron in the triplet state can experience a flip in spin and return to the first excited singlet state followed by vibrational relaxation then either non-radiative deactivation or fluorescence.

Fluorescence of this type can be observed after some time and is referred to as delayed fluorescence. It should be noticed that the life time of an electron in the excited state is about 10-9 second which is the time needed to observe fluorescence. Phosphorescence or delayed fluorescence can be observed after some time, usually exceeding 10-4 second. As all processes of deactivation and phosphorescence are possible, precautions should be considered in order to inforce circumstances that prefer fluorescence route.

Molecular Fluorescence Spectroscopy Molecular Fluorescence is a photoluminescence process in which molecules in solution are excited by absorption of electromagnetic radiation. The excited molecules then relax to the ground state, giving up their excess energy as photons,typically, but not necessarily in, visible radiation. One of the most attractive features of molecular fluorescence is its inherent sensitivity ( F, 0 ) which is often one to three orders of magnitude better than absorption spectroscopy ( P, P 0 ). Another advantage is the large linear concentration range of fluorescence methods, which is significantly greater than those encountered in absorption spectroscopy.

Most compounds absorb UV, little absorb visible, few fluoresce and very few phosphoresce so the order of the selectivity is : Phosphorescence > fluorescence > absorption. Fluorescence methods are, however, much less widely applicable than absorption methods because of the relatively limited number of chemical compounds that show appreciable fluorescence. This can be advantage due to minimizing interferences. Molecular fluorescence is measured by exciting the sample at the absorption wavelength, also called excitation wavelength, and measuring the emission at a longer wavelength called the emission or fluorescence wavelength. Usually, fluorescence emission is measured at right angles to the incident beam so as to avoid measuring the transmitted radiation. As we mentioned, the short-lived emission that occurs is called fluorescence, whereas luminescence that is much longer lasting is called phosphorescence.

Relative rates of relaxation depends on the molecule, the solvent, temperature, pressure, etc. Energy of Phosphorescence is less than the energy of fluorescence. Phosphorescence occurs at a longer wavelengths than fluorescence. Lifetime of Fluorescence (10-8 to 10-4 s) is very short compared to phosphorescence (10-4 to 10 2 s) because T S is forbidden and involves change of spin. Following absorption of radiation, the molecule can lose the absorbed energy by several pathways : 1- Vibrational relaxation which involves transfer of energy to neighboring molecules in solution. This termed external conversion. 2- non-radiative transitions from higher vibrational excited level to lower vibrational excited level, this called internal conversion.

3- The molecule after losing some of it s energy in non radiative transitions can return to the singlet ground state and emit radiation with wavelength longer than the absorption wavelength. This is termed fluorescence. 4- The molecule can return from the highest excited singlet state to the ground singlet state and emits radiation with wavelength equal to the wavelength of the absorption radiation. This is termed resonance fluorescence. 5- The molecule can undergo intersystem crossing which involves transfer and electron spin flip from the excited singlet state into a triplet state. Following this the molecule may return to the singlet ground state emitting radiation called phosphorescence with wavelength longer than fluorescence.

Notes : Two Possible Transitions in Excited State Single state electron spins opposed Triplet state electron spins are parallel In general, triplet state has lower energy than singlet state. Singlet to Triplet transition has a very low probability Singlet to Singlet Transition are more probable

Excitation Spectra and Fluorescence Spectra Because the energy differences between vibrational states is about the same for both ground and excited states, the absorption, or excitation spectrum, and the fluorescence spectrum for a compound often appear as approximate mirror images of one another. When measuring fluorescence spectra, the wavelength of the excitation ( absorption ) is kept constant, preferably at a wavelength of high absorption ʎ max, and the emission monochromator scans the spectrum. For measuring excitation spectra, the wavelength passing through the emission monochromator ( fluorescenc wavelength ) is kept constant preferably at ʎ max and the excitation monochromator is scanning. The excitation spectrum generally is identical to the absorption spectrum as the fluorescence intensity is proportional to the absorption.

Concentration and Fluorescence Intensity The radiant power of fluorescence F is proportional to the radiant power of the excitation beam absorbed: F = k(p 0 P) where, P 0 is the radiant power of the beam incident on the sample and P is the radiant power after it traverses a path length b of the sample solution. At low concentrations where fluorescence is most often employed F = K P 0 C where, c is the concentration of the fluorescent species ( analyte ) and K is a new proportionality constant. F is directly proportional to analyte concentration. Thus, a plot of the fluorescent radiant power versus the concentration of the emitting species should be, and ordinarily is, linear at low concentrations.

When c becomes great enough that the absorbance is larger than about 0.05 M, linearity is lost and F begins to reach a plateau with concentration. c 1 For a concentration above C 1 the calibration is no longer linear.

The constant K depends on several factors : 1- The intensity of the incident radiation P 0, K α P 0. So to increase F you increase P 0 by choosing the suitable source. 2- Quantum effeciency of fluorescence ɸ Quantum efficiency intensity of fluorescence F TH which is equal to intensity of absorption (P 0 P) int ensity of fluorescence int ensity of absorption ɸ = F/ ( P 0 P ) Because not all the absorbed radiation is emitted as fluorescence F as mentioned before, K α ɸ ɸ 1 3- Absorptivity a of the analyte as in Beer s law : K α a. 4- Cell bath length b, K α b

Factors affecting fluorescence intensity Quenching excited molecule returns to the ground state by nonradiative transitions as a result of a collision with other molecules in solution. Also other molecules may absorb the fluorescence from the analyte. Temperature : Decreasing temperature will decrease collisions and non-radiative transitions, and as a result will increase fluorescence. So some methods performed in cold medium. ph :The fluorescence of many analytes depends on the ph of the solution.some of these analytes are used as acid base indicators. Conjugation : molecules must have conjugation ( π electrons ) so that UV-Vis radiation can be absorbed and preferably have an aromatic rings.

Nature of substitution groups : Electron donating like NH 2, OH enhance fluorescence. Electron withdrawing like NO 2, COOH reduce fluorescence. More rigid the structure of the molecule more the intensity the fluorescence. Presence of O 2 and some metals decreases the fluorescence because both increase intersystem crossing so deaerate solution. Solvent : Decreased of viscosity of solvent leads to decreased fluorescnce due to increased collisions and thus increased external conversition processes. The most important transition that contribute to good fluorescence characteristics is the π π* transition since Ɛ for this transition is the largest. The n π* transition is damaging to fluorescence because it facilitate and increase the possibility of intersystem crossing.

Instrumentation Two general types of instruments exist: fluorometer use filters spectrofluorometr use diffraction grating to isolate the incident light and fluorescent light. Both types use the following scheme: The light from an excitation source passes through a filter or monochromator, and strikes the sample. A proportion of the incident light is absorbed by the sample, and some of the molecules in the sample fluoresce. The fluorescent light is emitted in all directions. Some of this fluorescent light passes through a second filter or monochromator and reaches a detector, which is usually placed at 90 to the incident light beam to minimize the risk of transmitted or reflected incident light reaching the detector

Spectrofluorometer components 1) Instrument

Various light sources may be used as excitation sources. Commonly a xenon lamp which has a continuous emission spectrum with nearly constant intensity in the range from 300-800 nm is used.. Two monochromators are used, emission and excitation.the most common type of monochromator utilizes a diffraction grating As mentioned before. The detector can either be single-channel or multichannel. The singlechannel detector can only detect the intensity of one wavelength at a time, while the multichannel detects the intensity of all wavelengths simultaneously, making the emission monochromator unnecessary. Sample Cell : cylindrical and rectangular cell fabricated of glass or silica are employed for fluorescence measurements.

Methods of fluorescence determination Direct methods - natural fluorescence of the fluorecent sample is measured. Indirect (derivatisation) methods - the nonfluorescent compound is converted into a fluorescent derivative by specific reaction or marked with fluorescent dye by attaching dye to the studied substance. Quenching methods - The reduction in the intensity of some fluorescent dye due to the quenching action of the measured analyte e.g. metal ions.

Applications Luminescence methods are amongst some of the most sensitive and selective methods of analysis available. Detection limits are in the ppm levels for absorption spectrophotometry and in the ppb levels for luminescence methods. Fluorescence spectroscopy is used in, biochemical, medical, food products, pharmaceuticals, natural products and chemical research fields for analyzing organic compounds. In analytical chemistry, fluorescence detectors are used with HPLC. Fluorescence is most commonly observed in compounds containing aromatic functional groups.quantum efficiency increases with the number of rings.

Molecular Phosphorescence Spectroscopy Phosphorescence is a photoluminescence phenomenon that is quite similar to fluorescence. Understanding the difference between these two phenomena requires understanding of electron spins and the difference between a singlet state and a triplet state. Ordinary molecules exist in the ground state with their electron spins paired. A molecular electronic state in which all electron spins are paired is said to be a singlet state.

When one of a pair of electrons in a molecule is excited to a higher-energy level, a singlet or a triplet state can be produced. In the excited singlet state the spin of the promoted electron is still opposite that of the remaining electron. In the triplet state, however, the spins of the two electrons become unpaired and are thus parallel. The excited triplet state is less energetic than the corresponding excited singlet state. One of the disadvantages of phosphorimetry is that it requires liquid nitrogen to cool the sample in order to minimize the unradiative transitions,

Chemiluminescence Methods Chemiluminescence is produced when a chemical reaction ( mostly exothermic oxidation ) yields an excited molecule, which emits light as it returns to the ground state. One attractive feature of chemiluminescence for analytical uses, is the very simple instrumentation. Since no external source of radiation is needed for excitation, the instrument may consist of only a reaction vessel and a photomultiplier tube. Generally, no wavelength selection device is needed because the only source of radiant is the chemical reaction. Chemiluminescence differs from fluorescence or phosphorescence in that the electronic excited state is the product of an exothermic chemical reaction rather than of the absorption of radiation. A standard example of chemiluminescence in the laboratory setting is the luminol test. Here, blood is indicated by luminescence upon contact with iron in hemoglobin.

Advantages of chemiluminesence : 1- High sensitivity. 2- Inexpensive. 3- Chemiluminescence has been used as a detector in many flowinjection analysis methods and in HPLC,,,, etc.

Applications : Many analytes could be directly or indirectly quantified by chemiluminescence. The indirect methods can be performed either by a chemical reaction producing product that emit luminescent or by measuring the compounds quenching effect. Analysis of nitrogen oxides in the atmosphere : NO + O 3 NO 2 * + O 2 NO 2 * NO 2 + light Luminol + H 2 O 2 peroxidase 3-aminoftalate + light Luminol and peroxidase before adding H 2 O 2 Chemiluminisc ence after addition H 2 O 2

على الراغبين في االستماع الى محاضرة عن موضوع هذه الوحدة باللغة العربية الضغط على كل من الروابط التالية : part 18 : Molecular luminescence spectrometry part 19 : Molecular luminescence spectrometry part 20 : Molecular luminescence spectrometry part 21: Molecular luminescence spectrometry