EXPERIMENTAL AND SIMULATION TEMPERATURE EVALUATION WHICH DETERMINE THERMAL COMFORT

Similar documents
Environmental Engineering

Principles and Applications of Building Science Dr. E Rajasekar Department of Civil Engineering Indian Institute of Technology, Roorkee

NUMERICAL MODELLING OF TEMPERATURE AND AIR FLOW DISTRIBUTION IN ENCLOSED ROOM

CZECH TECHNICAL UNIVERSITY IN PRAGUE FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF ENVIRONMENTAL ENGINEERING

Thermal behavior and Energetic Dispersals of the Human Body under Various Indoor Air Temperatures at 50% Relative Humidity

OPERATIVE TEMPERATURE SIMULATION OF ENCLOSED SPACE WITH INFRARED RADIATION SOURCE AS A SECONDARY HEATER

Project 2. Introduction: 10/23/2016. Josh Rodriguez and Becca Behrens

CAE 331/513 Building Science Fall 2017

Institut national des sciences appliquées de Strasbourg GENIE CLIMATIQUE ET ENERGETIQUE APPENDICES

Solar Radiation Protections on Façades: A Case Study in a Hot Semi-Humid Climate

Computer Evaluation of Results by Room Thermal Stability Testing

An Investigation on the Human Thermal Comfort from a Glass Window

Thermal Comfort; Operative Temperature in the Sun

ARCH 348 BUILDING AND ENVIRONMENTAL SYSTEMS

A Simulation Tool for Radiative Heat Exchangers

Prediction of Thermal Comfort and Ventilation Efficiency for Small and Large Enclosures by Combined Simulations

Modelling and Experimental Validation Possibilities of Heat Transfer Room Model

Modeling Human Thermoregulation and Comfort. CES Seminar

EXPERIMENTAL ANALYSIS OF AIR-CONDITIONING IN HOSPITAL ROOMS BY MEANS OF LIGHT RADIANT CEILINGS

Effects of Air Temperature, Mean Radiant Temperature, and Air Velocity on the Globe and Operative Temperatures

EVALUATION OF THERMAL ENVIRONMENT AROUND THE BLIND ON NON-UNIFOM RADIANT FIELDS A CFD SIMULATION OF HEAT TRANSFER DISTRIBUTION NEAR THE BLINDS

Field evaluation of the performance of a radiant heating/cooling ceiling panel system

NUMERICAL ANALYSIS OF THERMAL COMFORT PARAMETERS IN LIVING QUARTERS

TREES Training for Renovated Energy Efficient Social housing

THERMAL COMFORT IN HIGHLY GLAZED BUILDINGS DETERMINED FOR WEATHER YEARS ON ACCOUNT OF SOLAR RADIATION. Dominika Knera 1 and Dariusz Heim 1

Air Diffusion Designing for Comfort

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

AMBIENT WELL-BEING PARAMETERS IN THE INDOOR SPACES OF OFFICE BUILDINGS. CASE STUDY

L ESSON P LAN:DETERMINING THE E FFECT OF D ISTANCE (PART 1) AND I NCLINATION (PART 2)

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Computational Modelling of the Impact of Solar Irradiance on Chemical Degradation of Painted Wall Hangings in an Historic Interior

EFFECT OF INTERNAL LONG WAVE RADIATION AND CONVECTION ON FENESTRATION SIMULATION

DEVELOPMENT OF COOLING LOAD TEMPERATURE DIFFERENTIAL VALUES FOR BUILDING ENVELOPES IN THAILAND

ISO 7730 INTERNATIONAL STANDARD

Environmental Engineering. Family of heating appliances

Study on Thermal Load Calculation for Ceiling Radiant Cooling Panel System

Energy and Insolation Review 2

The energy performance of an airflow window

Daylighting Buildings Nexus November 12, 2009

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

MDSRC Proceedings, December, 2017 Wah/Pakistan. Cooling load analysis by CLTD and RLF. Sher ali nawaz 1 Muzammil shahbaz 2

MODELLING THERMAL COMFORT FOR TROPICS USING FUZZY LOGIC

Numerical Analysis of Comfort and Energy Performance of Radiant Heat Emission Systems

Define umbra and penumbra. Then label the umbra and the penumbra on the diagram below. Umbra: Penumbra: Light source

Unit C REVIEW Heat and Temperature

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

FUNDAMENTALS OF HVAC

PAUL RUDOLPH Oriental Masonic Gardens

Topic 5 Practice Test

Coupled CFD/Building Envelope Model for the Purdue Living Lab

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

PASSIVE SOLAR HEATING

Conduction is the transfer of heat by the direct contact of particles of matter.

Indoor Environment Quality. Study the world Capture the elements Environmental testing made easy. MI 6201 Multinorm. MI 6401 Poly.

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM

Testing the performance of a green wall system on an experimental building in the summer

Response function method

ROOM AVERAGE VELOCITY EQUATION A TOOL TO IMPROVE DESIGN OF THERMAL COMFORT CONDITIONS

CAE 331/513 Building Science Fall 2016

Validation of IDA Indoor Climate and Energy

The influence of solar radiation on the distribution of temperatures in historic masonry

Section 1: Overhang. Sizing an Overhang

NUMERICAL ANALYSIS OF HEAT STORAGE AND HEAT CONDUCTIVITY IN THE CONCRETE HOLLOW CORE DECK ELEMENT

Transient Analysis of the Buoyancy Driven Flow in a Passive Solar System for Indoor Heating

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

CFD as a Tool for Thermal Comfort Assessment

Winter Night. Thermos 6mm Outdoors # #

MATHEMATICAL MODELING OF A COMBINED HOT-WATER HEATING SYSTEM BY MEANS OF THE FINITE ELEMENT METHOD

STUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION

5. AN INTRODUCTION TO BUILDING PHYSICS

Solar Control in Traditional Architecture, Potentials for Passive Design in Hot and Arid Climate

Analysis of Split Air Conditioner Noise using Sound Intensity Mapping

Building heat system sizing

Design strategy for Low e windows with effective insulation

Heat Transfer. Energy from the Sun. Introduction

ASSESSING THE ACCURACY OF GLOBE THERMOMETER METHOD IN PREDICTING OUTDOOR MEAN RADIANT TEMPERATURE UNDER MALAYSIA TROPICAL MICROCLIMATE

Exercises Conduction (pages ) 1. Define conduction. 2. What is a conductor?

SIMULATION OF FRAME CAVITY HEAT TRANSFER USING BISCO v10w

If there is convective heat transfer from outer surface to fluid maintained at T W.

Natural Causes of Climate. 3B Day 2

Temperature Changes OBJECTIVES PREPARATION SCHEDULE MATERIALS. The students. For each student. For each team of two. For the class

Patterns of Change on Earth

Outdoor Thermal Comfort and Local Climate Change: Exploring Connections

THERMAL INERTIA OF HOLLOW WALL BLOCKS: ACTUAL BEHAVIOR AND MYTHS

Infrared Experiments of Thermal Energy and Heat Transfer

Chapter Seven. Solar Energy

Topic 6: Transferring Energy

125 TIE Theory of Indoor Environment THERMAL COMFORT

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

Cooling Load Calculation and Thermal Modeling for Vehicle by MATLAB

Effect Of Orientation On Indoor Temperature Case Study: Yekape Penjaringansari Housing in Surabaya

PROPAGATION, NOISE CRITERIA

1. The type of energy described by Energy C is which type of energy?

Earth Science Summer Assignment. I. hypothesized that more people go to the grocery store on Saturday night than on any other night of the week

Neural computing thermal comfort index for HVAC systems

Group Research Projects

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

Solar Matters II Teacher Page

Transcription:

EXPERIMENTAL AND SIMULATION TEMPERATURE EVALUATION WHICH DETERMINE THERMAL COMFORT ubomír Hargaš, František Drkal, Vladimír Zmrhal Department of Environmental Engineering, Faculty of Mechanical Engineering, Czech Technical University, Technická 2, 166 27 Prague 6, Czech Republic Lubomir.Hargas@fs.cvut.cz ABSTRACT The paper deals with the evaluation of operative temperature and indoor air temperature by computer simulation method and their comparison with measured temperatures in real air-conditioned room. Also calculation of the extreme thermal states in winter and summer time by the program created in Excel software is shown. Difference between operative temperature and indoor air temperature is given by mean radiant temperature in the room, which is affected by indoor and outdoor radiant sources. INTRODUCTION Thermal comfort in the spaces with human occupancy in hygienic requirements is determine by operative temperature t o ( C), or globe temperature t g ( C). But designers of the air-conditioning and heating systems, are not able to count those two temperatures with common design methods using. This is because operative temperature t o and globe temperature t g depends on the surface temperatures of the walls. Surface temperature of the wall is possible to calculate by simulation methods. Czech legislative act [1] defines operative temperature t o ( C) and globe temperature t g ( C) as a criteria for microclimate definition. Temperature t o is quite easy to solve on the basis of measurement of the indoor air temperature t a ( C), globe temperature t g ( C) and air velocity w (m/s). Air-conditioning and heating design calculation methods mostly determine heat load and heat loss by convective heat transfer from the wall surface. For this kind of calculation the indoor air temperature determines the indoor environment. When designers use common calculation methods, they don t know wall surface temperatures (mean radiant temperature) and they are not able to determine operative temperature in the space as well. In the hygienic regulations from 1978 was listed equation, which express relationship between indoor air temperature t a and globe temperature t g for winter and summer time ta tg B = + (1) where coefficient B is defined for summer (if the shading is used properly) B = 0 (2) and for winter (if the heating system compensate influence of the negative radiation by the windows) 1/ 2 4. 720w 1. 710 B =. q 1/ 2 m. 44. 500w + 122. 965w where ( 0 913 19 14) (3) w (m/s) is air velocity (at intervals from 0 to 0.5 m/s) q m (W/m 2 ) is specific heat production of the human body Equations mentioned above is evidence, that also in the past was ambition to give background to the designers, which would respect influence of the radiation and air velocity for thermal comfort. The assumed (required) operative temperature t o in the space is possible to define with using present calculation methods (dynamic simulation of the building energetic balances and environmental engineering systems). Matter of those methods is calculation of the mean radiant temperature t r ( C) under stationary or dynamic conditions. Important thing is that operative temperature is changing in every point of the space. Also in case when we assume air temperature to be constant. Changes of operative temperature are affected by mean radiant temperature, which depends on location in the space. Operative temperature changes are useful in the room to follow in horizontal direction and vertical direction as well. There is influence of the window surfaces (summer and winter) in horizontal direction and influence of the cooling or heating ceilings (summer and winter) in vertical direction. Operative temperature analysis in vertical direction is also important for consideration of the conditions given in [1] for height 0.1 m (height of ankles), 1.1 m (height of head of the sitting person) and 1.7 m (height of head of the standing person).

In this paper theoretical and experimental results are presented, which deals with specification of the mean radiant temperature, globe temperature and operative temperature: a) mean radiant temperature calculation in general point of the room software Excel (VBA) b) operative temperature calculation in the room for stationary thermal balance software Excel c) mean radiant temperature and operative temperature calculation for dynamic thermal balance ESP-r simulation program d) experimental determination of the mean radiant temperature and operative temperature in the airconditioned room in summer time MEAN RADIANT TEMPERATURE CALCULATION IN GENERAL POINT OF THE ROOM SOFTWARE EXCEL Mean radiant temperature calculation mentioned in [1], consist of determination of the view factors in random point on the basis of the geometric position ratio between radiant and irradiated surface (person). In the fact mean radiant temperature should be detached to the human body surface (S t = 1.8 m 2 ), but such a calculation is not very easy. For simplification, the mean radiant temperature is detached to the globe surface; let us say to the point, which is located in the human centre of gravity. The view factor for radiant point defined according to figure 1 can be calculated as ϕ 2 2 2 1 1 c a + b + c 1 2 = arctg (4) 8 4π ab On the basis of the mentioned calculation method the program for monitoring of mean radiant temperature distribution in the space MRT Analysis was created. By using of this program it is possible to evaluate mean radiant temperature in the isomap form in Figure 1 Parameters for view factor calculation random plane of the space. Program allows calculation in the simply rectangle enclosure with perpendicular walls. It is possible to insert additional surface to the each wall (e.g. window, ceiling) with corresponding surface temperature. It is possible to evaluate mean radiant temperature t r or operative temperature t o as well. Graphical example of the evaluation is visible in the figure 3. Example represents the room with a cooled ceiling (18 C) and warmed surface of the window (35 C). Mean radiant temperature calculation was carried out with mesh 50 x 32 points in the vertical plane located in the middle of the room. From the figure it is visible, that mean radiant temperature is not identical in the space. Influence of thermal boundary conditions and space geometry is present. Program is able to evaluate operative temperature (for defined air velocity) in random vertical and horizontal planes, i.e. also in the vertical points mentioned in [1] and [8]. OPERATIVE TEMPERATURE CALCULATION IN THE ROOM FOR STATIONARY THERMAL BALANCE SOFTWARE EXCEL Calculation target was to determine the difference between indoor air temperature t a and operative temperature t o in the extreme climatic conditions under which the air-conditioned unit was designed. Calculation was carried out separately for summer and for winter [3], [4]. Basis of calculation were heat load calculation (summer) according to SN 730548 [5] and heat loss calculation (winter) according to SN 060210 [6]. For set indoor air temperature, climatic conditions, thermal conditions in surrounding rooms, heat transfer coefficient, overall heat transfer coefficient and position of the mean radiant temperature the program calculate surface temperatures of the walls and windows t pi. Next calculation allows to determine mean radiant temperature t r in random point of the space. According to set value of indoor air temperature t a and air velocity w it is possible to define operative temperature t o in chosen point. The model of the room with dimensions 7.3 x 4.6 x 3.1 m (l x w x h) was analysed. Building in which is room located, is made of iron-concrete skeleton (ceiling and floor is made of concrete with thermal insulation), indoor walls are made from hollow bricks, outdoor walls are also made from hollow bricks with thermal insulation. For this model the whole outdoor wall was made from glass U = 1.5 W/m 2 K.

Monitoring cases: Winter - Room is heated by ceiling radiant heating system with surface temperature 40 C and 50 C, indoor air temperature 20 C. Summer (shading coefficient of the blinds is 0.6) - Air-conditioned room, indoor air temperature 25 C. Room is heated by ceiling radiant heating system with surface temperature 40 C, 50 C, indoor air temperature 20 C Mean radiant temperature t r and operative temperature t o was calculated in the middle of the room along its height (indoor air temperature t a = 20 C is assumed homogenous in the whole space). MEAN RADIANT TEMPERATURE AND OPERATIVE TEMPERATURE CALCULATION FOR DYNAMIC THERMAL BALANCE ESP-R SIMULATION PROGRAM Dynamic simulation model was created by ESP-r simulation program. For computation room described in previous article was chosen; outside wall was simulated like in a real room in which experiments described in next article was carried out (3 windows in outside wall at size of 2,2 x 2,0 m). Model of the room is in the figure 2. Results are visible in figure 4. According to [1] the microclimate was evaluated in three elevations: 0.1 m; 1.1 m; 1.7 m above the floor. Results of calculation for those elevations are visible in the table 1. Table 1 Operative temperature t o in vertical direction Elevations above the floor (m) 0.1 m (ankles) 1.1 m (the head of the sitting person) 1.7 m (head of the standing person) Operative temperature t o ( C) Ceiling temperature t p = 40 C 21.3 22.,0 22.7 Ceiling temperature t p = 50 C 22.3 23.4 24.4 Air-conditioned room, indoor air temperature 25 C Surface temperature of the inside blinds was defined on the basis of experiment [3] under extreme summer conditions at south-east side of the room and was set to 46 C. Operative temperature was defined along vertical line to the outside glass wall, in the middle of the room in the height of 1.1 m above the floor. Results are visible in the figure 5. Figure 2 Model of the room in the ESP-r In ESP-r software it is possible to calculate the operative temperature in random point by MRT sensor (Mean Radiant Temperature). Sensor represents standing person has a block shape with dimensions of 0,3 x 0,3 x 1,1 m (l x w x h), located 0,7 m above the floor. Simulation was carried out using climatic database measured in Department of Environmental Engineering, Faculty of Mechanical Engineering, CTU in Praque. Results of the simulation are visible in the figure 6 and 7. In both pictures there are also thermal comfort measured values. Simulation and measurement was carried out under the same climatic conditions. Graph in the figure 6 shows quite good agreement of operative temperature t a gained by simulation and by measurement as well. It is necessary to mention that set indoor air temperature (22.5 C) was in the simulation evaluated (in term of thermal comfort in the summer) as a low value. In the figure 6 it is visible high percentage of dissatisfied people in the space (PPD) up to 24 %. When operative temperature is higher (23.5 C) PPD index decreases to 5 %. Graph in the figure 7 shows simulating values of the indoor air temperature. At noon (extreme heat load) indoor air temperature is changing from maintained value of 22.5 C to 23.5 C. This happened because of the low cooling output

of the air-conditioned unit, which was not enough for maintain temperature of 22.5 C. Massive drop of the mean radiant temperature in the night and in the morning is affected by overestimating of the long wave radiation cooling in ESP-r. EXPERIMENTAL DETERMINATION OF THE MEAN RADIANT TEMPERATURE AND OPERATIVE TEMPERATURE IN THE AIR-CONDITIONED ROOM IN SUMMER TIME Measurement of the inside environment parameters was carried out from 8/6 to 11/6/ 2004. Thermostat of the air-conditioned unit (split system) was set to 22.5 C. Continuously were measured: indoor air temperature t a, globe temperature t g, surface temperature of selected subjects t pi and outdoor air temperature t e. At the same time the intensity of sun radiation was measured in the department solar laboratory. Indoor air temperature in the room was measured with shaded thermometer in two points, on the window and near the internal wall at the height of 1.7 m above the floor. This height complies with the CSN EN ISO 7726 standard and represents the height of head of standing person. Equal conditions were used for measurement of the globe temperature t g by globe thermometer (diameter of 100 mm). Surface temperature t pi was scanned on selected superficies, i.e. window, floor, cabinet, ceiling. In the figures 6 and 7 it is visible oscillation of the temperatures (about 0.3 C). Oscillation is affected by accuracy of the sensors and accuracy of the measurement central. There is also visible stronger temperature oscillation at noon, which is affected by short-time variability of the sun radiation. REFERENCES [1] Naízení vlády. 523/2002 Sb., kterým se mní naízení vlády. 178/2001 Sb., kterým se stanoví podmínky ochrany zdraví zamstnanc pi práci [2] Smrnice o hygienických požadavcích na pracovní prostedí. Hygienické pedpisy. Ministerstvo zdravotnictví SR, Avicenum Zdravotnické nakladatelství [3] Hargaš, L.: Studie tepelného komfortu. Fakulta strojní VUT v Praze, 2005. Nepublikováno [4] Dvoák, K.: Mikroklima klimatizované místnosti. Diplomová práce. Fakulta strojní VUT v Praze, 2005 [5] SN 730548: Výpoet tepelné zátže klimatizovaných prostor. Úad pro normalizaci a mení, 1985 [6] SN 06 0210: Výpoet tepelných ztrát budov pi ústedním vytápní. NI, 1994 [7] SN EN ISO 7726: 1993 Tepelné prostedí Pístroje a metody mení fyzikálních Veliin. NI, 1993 [8] SN EN ISO 7730: Mírné tepelné prostedí Stanovení ukazatel PMV a PPD. Popis podmínek tepelné pohody. NI, 1997 Measured temperatures were recorded with EfLab central (15 minutes recording interval). Air velocity in the room (measured by heating string) was recorded with programmable central Almemo 3290. During the measurement it was investigated that air velocity was not higher than 0.2 m/s. This simplified interpretation of the operative temperature.

Figure 3 Evaluation of the mean radiant temperature in the izomap form Temperature ( C) 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 Sensor distance from the floor (m) Mean radiant temperature (tps = 40 C) Operative temperature (tps = 40 C) Mean radiant temperature (tps = 50 C) Operative temperature (tps = 50 C) Figure 4 Vertical course of the temperatures for radiant ceiling heating (ceiling temperature 40 C, 50 C) 36 35 34 33 Temperature ( C) 32 31 30 29 28 27 26 25 0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4 4.4 Sensor distance from the internal wall (m) Mean radiant temperature Operative temperature Figure 5 Horizontal course of the temperatures in the midle of the air-conditioned room in height of 1,1 m

Figure 6 Results of measured and simulated values of the operative temperature and PPD Figure 7 Results of measured and simulated values of the indoor air temperature and mean radiant temperature