Identification of Novel Hydrogen-Substituted Polyfluoroalkyl Ether. Sulfonates in Environmental Matrices near Metal-Plating Facilities

Similar documents
Supporting Information

8 Laboratory of Environmental Pollution Control and Remediation Technology, Sun

Determination of Polyfluoroalkyl Substances (PFAS) in Food Products

Trends of Perfluorinated Alkyl Substances in Herring Gull Eggs from Two Coastal. Colonies in Northern Norway:

A comparison between HRAM Orbitrap technology and MS/MS for the analysis of polyfluoroalkyl substances by EPA Method 537

Supporting Information

Supporting Information. Mass Balance of Perfluorinated Alkyl Acids in a Pristine Boreal Catchment

Per and Polyfluoroalkyl Substances (PFAS) in AFFF Formulations and Groundwater

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Supporting Information

CASE STUDY 3: Quantitative and Qualitative Analysis of Perfluoroalkyl Substances (PFASs) in Wildlife Samples Using the Xevo G2-XS Q-Tof GOAL

Conc n of A OAs present (um) Conc n of B OAs present (um)

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Novel fluoroalkylated surfactants in soils following firefighting foam deployment during the Lac-Mégantic railway accident

Supporting Information. Treatment of Aqueous Film-Forming Foam by Heat-Activated. Persulfate Under Conditions Representative of

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

A Technique for Determining Total Oxidizable Precursors (TOP) of Perfluoroalkyl Compounds

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Characterization of Two Passive Air Samplers for Per and Polyfluoroalkyl Substances

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Ondansetron Hydrochloride Tablets

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Water-to-air transfer of perfluorinated carboxylates and sulfonates in a sea spray simulator

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

A Fully Validated LC-MS/MS Method for Analysis of Trace Fluorotelomer Alcohols from Water

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

16 Malachite green 17 Leucomalachite green

Features or compounds? A data reduction strategy for untargeted metabolomics to generate meaningful data

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Methods for proteome analysis of obesity (Adipose tissue)

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

This method describes the identification of the following prohibited colorants in cosmetic products:

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

LC-MS/MS Analysis of Phytocannabinoids and their

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

Egualen Sodium Granules

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Environmental Mass Spectrometry DR. RALPH N. MEAD

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Determination of trace anions in concentrated hydrofluoric acid

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

SUPPORTING INFORMATION

Mass Spectrometry. Ionizer Mass Analyzer Detector

TOMAHAQ Method Construction

Novel fluorescent cationic benzothiazole dye response to G-quadruplex aptamer as a novel K + sensor

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

MassHunter TOF/QTOF Users Meeting

Accurate Mass Analysis of Hydraulic Fracturing Waters

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Supporting Information

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Amphiphilic diselenide-containing supramolecular polymers

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

WADA Technical Document TD2003IDCR

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

SUPPLEMENTARY INFORMATION

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Supporting information Online HPLC-ESI-HRMS Method for the Analysis and Comparison of Different Dissolved Organic Matter Samples

Mark Strynar, Rebecca McMahen, Shuang Liang, Sonia Dagnino, Andrew Lindstrom, Erik Andersen, Larry McMillan, Michael Thurman, Imma Ferrer, Carol Ball

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Chapter 5. Irbesartan. Page no. 64 to 80

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Transcription:

Supporting Information Identification of Novel Hydrogen-Substituted Polyfluoroalkyl Ether Sulfonates in Environmental Matrices near Metal-Plating Facilities Yongfeng Lin 1,2, Ting Ruan 1,2 *, Aifeng Liu 1,3, Guibin Jiang 1,2 1 State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China 2 University of Chinese Academy of Sciences, Beijing 100049, China 3 CAS Key Laboratory of Biobased Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101, China *Corresponding author Dr. Ting Ruan Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences Tel: 8610-6284-9334 Fax: 8610-6284-9179 E-mail: tingruan@rcees.ac.cn Number of pages: 44 Number of Tables: 9 Number of Figures: 15 S1

Contents Preparation of super-reduced CCA assay...s5 Non-target screening workflow...s6 Laboratory purification of the 1H-6:2 PFESA and 1H-8:2 PFESA standards...s7 Spike recovery experiments in river water and sediment samples...s8 References...S10 Table S1. Detailed information on the 26 features generated in the non-target screening workflow with VIP threshold > 1...S11 Table S2. Homodimers of Cl-6:2 PFESA and 1H-6:2 PFESA in the 2-fold diluted supernatants in the super-reduced CCA assay...s13 Table S3. Detailed information (acronyms, chemical names, molecular structures, theoretical monoisotopic masses, retention behaviors and characteristic fragmentation ions) of per- and polyfluoroalkyl substances in the suspect screening procedure...s14 Table S4. Instrumental parameters on chromatographic separation and mass spectrometry...s16 Table S5. Method quantification limits (MQL) of all target analytes in river water and sediment samples...s19 Table S6. Spike recoveries of target analytes in river water and sediment samples..s20 Table S7. Recoveries of surrogate standards and matrix effects of injection standards in river water and sediment samples...s21 Table S8. Descriptive statistics of identified per- and polyfluoroalkyl substances in the sampling regions...s22 Table S9. Spearman's correlation analysis of quantified PFAS concentrations in river water samples from the Fenghuajuang River... S23 Figure S1. Negligible changes of Cl-6:2 PFESA and 1H-6:2 PFESA amount in an additional incubation period of up to 40 min when 3.6 ml of methanol was added in the super-reduced CCA incubation tubes at appointed incubation time, showing transformation reaction effectively retarded...s24 Figure S2. The sampling map showing spatial distribution of Cl-6:2 PFESA, 1H-6:2 PFESA, Cl-8:2 PFESA and 1H-8:2 PFESA in river water and sediment samples in Pan S2

River in Shandong Province. (Pink pentacle, metal-plating manufactory; black tetragon, sampling sites for river water and sediment samples)...s25 Figure S3. Non-target screening workflow for generation, filtering, ranking and structure confirmation of potential metabolites in Cl-6:2 PFESA reductive transformation process...s26 Figure S4. Results of principal component analysis (PCA, p < 0.05) show a clear separation of the metabolite-transformation and dosed-control dataset groups, which were illuminated by the red and blue dots, respectively. A. Kruskal s non-metric multidimensional scaling presents distinct distribution of samples in metabolite transformation group in association with incubation time; B. Score plots of PCA analysis; C. R 2 and Q 2 represent goodness of fit and prediction of the three primary factors in the statistical analysis procedures...s27 Figure S5. Results of orthogonal partial least-squares-discriminant analysis (OPLS-DA, p < 0.05) show a clear separation of the metabolite-transformation and dosed-control dataset groups, which were illuminated by the red and blue dots, respectively. A. R 2 (cum) and Q 2 (cum) represent goodness of fit and prediction in the statistical analysis procedures; B. Score Scatter Plot represents distinct distribution of samples in metabolite-transformation group in association with incubation time; C. Twenty-six features were identified with VIP values > 1; D. Distribution of the identified 26 features in the III and I quadrants of the S-Plot, illustrating the Cl-6:2 PFESA and potential metabolite candidates in elimination (DOWN) and generation (UP) trends with high constituent abundances, respectively...s29 Figure S6. MS 2 fragmentation patterns of the Cl-PFESA and H-PFESA standards (A. Cl-6:2 PFESA; B. 1H-6:2 PFESA; C. Cl-8:2 PFESA; D. 1H-8:2 PFESA). Solid-line arrows represent characteristic neutral loss of HF, C2F4SO3 and CF2O in the HCD fragmentation process...s31 Figure S7. Reconstructed total ion chromatography of deprotonated molecular ions of the dosed Cl-6:2 PFESA and proposed transformation products in both standard solution (10 ng/ml in methanol) and supernatant in the super-reduced CCA assay. Mass windows were set as theoretical monoisotopic mass ± 5 ppm. Instrumental responses (IRs) in the supernatant represented metabolite contents in samples at incubation time of 50s...S32 Figure S8. MS 2 fragmentation patterns of 2H-6:2 PFESA (A. HCF2(C5HF9)OC2F4SO3 - ) and 1H-6:2 PFUESA (B. HCF2(C5F8)OC2F4SO3 - ) in the HCD mode in the super- S3

reduced CCA assay at incubation time of 50s. Solid-line arrows represent characteristic neutral loss of HF, C2F4SO3 and CF2O in the HCD fragmentation process...s33 Figure S9. MS 3 fragmentation pattern of [C6HF12O] - generated from MS 2 of 1H-6:2 PFESA, and MS 2 spectra for homodimers of Cl-6:2 PFESA and 1H-6:2 PFESA in HCD mode. (A. [C6HF12O] - ; B. [2M-2H+Na] - homodimer of 1H-6:2 PFESA; C. [2M- 2H+NH4] - homodimer of Cl-6:2 PFESA) in the super-reduced CCA assay at incubation time of 50s. Solid-line arrows represent characteristic neutral loss of HF and CF2O in the HCD fragmentation process...s34 Figure S10. Tentative molecular structures of 2H-6:2 PFESA (CL: Level 2b) and 1H- 6:2 PFUESA (Cl: Level 3)...S35 Figure S11. Retention time of 1H-6:2 PFESA and 1H-8:2 PFESA in the LC column of Autopurification HPLC-MS system...s36 Figure S12. 1 H-NMR and 19 F-NMR spectrum of laboratory-purified 1H-6:2 PFESA and 1H-8:2 PFESA standards. (A. 1 H-NMR of 1H-6:2 PFESA; B. 19 F-NMR of 1H-6:2 PFESA; C. 1 H-NMR of 1H-8:2 PFESA; D. 19 F-NMR of 1H-8:2 PFESA)...S37 Figure S13. Detailed information on the purity of the 1H-6:2 PFESA and 1H-8:2 PFESA standards based on the LC-ELSD method. (A. 1H-6:2 PFESA; B. 1H-8:2 PFESA)...S41 Figure S14. Extraction efficiency of target analytes spiked in blank sediment samples. Each sample was extracted for three times and each extract was analyzed individually. Only about 2% of the target analytes were recovered in the third extraction, indicating duplicate extraction as performed in our experiment could reach sufficient extraction for all analytes....s43 Figure S15. Retention behaviors of 1H-6:2 PFESA, linear-pfos and Cl-6:2 PFESA on reversed C18 HPLC column. MS channels were generated by injection of standard solution (10 ng/ml in methanol)...s44 S4

Preparation of super-reduced CCA assay Preparation of super-reduced cyanocobalamin (CCA, Vitamin B12) assay was similar to procedures reported in previous literature with minor modifications. 1,2 In brief, all incubation solutions were produced under nitrogen gas condition in a Lab 2000 anaerobic chamber (Etelux Inc., Beijing, China). Water and oxygen contents were less than 0.1 and 274 part-per-million in volume (ppm, v/v), respectively. Solution of reductive agent titanium (III) citrate was firstly prepared by mixing 10 ml of 0.4 M sodium citrate and 3 ml of 20% w/v titanium chloride in 2 N HCl in a 50 ml polypropylene centrifugation tube (Corning Inc., Corning, NY), with ph value subsequently adjusted to 7.0 by adding 5.1 ml of 2 M sodium carbonate and 21.9 ml of ultrapure water. Approximately 1.0 mg of cyanocobalamin was added into the centrifugation tube, and super-reduced working solution (18.4 μm in case of CCA) was obtained with detectable endpoint of color change into dark black. Transformation process was performed by mixing 400 μl of Cl-6:2 PFESA methanol solution and 1 ml of super-reduced CCA solution in 15 ml polypropylene centrifugation tubes at room temperature (25 ± 2 C). Control samples containing the same amounts of dosed analytes, solvent and agents except for CCA (CCA-lacking assay) were also applied. An additional test was performed by adding 2 ng of Cl-6:2 PFESA and 1H-6:2 PFESA standards in CCA-lacking assay. Measured recoveries by external calibration curves (0.1 50 ng/ml methanolic solution) were 95 ± 4% (n = 6) and 95 ± 4% (n = 6), respectively. The data were consistent with quantified results (98%, 97%, 94% and 97% for M3PFHxS, MPFOS, M8PFOS and M2-6:2 FTSA, respectively) of isotope-labeled injection standards, indicating negligible matrix effects of the PFESA compounds in the assay. S5

Non-target screening workflow A non-target screening workflow using multivariate statistic tools for mass detection and filtering was described in Figure S3. Raw data of MS 1 spectrum in both metabolitetransformation and dosed-control groups was introduced in the XCMS processing package, which resulted in recognition of 3389 features. A clear separation of the two dataset groups was observed by principal component analysis (PCA, Figure S4), in which the first two primary factors contributed to 60% of variations. Additionally, distinct distribution of samples in metabolite-transformation group was observed in association with incubation time, further indicating representativeness of the identified features for the transformation process. All information was subjected to an additional check by the 80% Rule, 3 and 610 features with missing values were further ruled out. CF2 Normalized AKMD plot was successfully applied to identify several novel fluorinated chemicals in water by visualizing instrumental signals in the form of homologue series. 4,5 Considering the normal AKMD of PFASs was generally ranged 0.8 1.1, CF2 normalized AKMD was then calculated and applied to exclude irrelevant mass information with 1412 features remained for further analysis. Furthermore, baseline noise of 1 10 5 was set as instrumental response (IR) threshold, with another 103 features removed in the workflow. The remaining 1309 features were considered as the most informative masses, in which 679 features were found to be significantly different in relative abundance between both dataset groups (averaged IR change > 1.5 fold, p < 0.05, student s t-test). Moreover, orthogonal partial least-squares-discriminant analysis (OPLS-DA) was carried out to locate potential metabolites in the remaining features that contributed S6

primarily to the changes of chemical profiles. As shown in Figure S5, distinct distribution of samples (R 2 (cum) = 0.981, Q 2 (cum) = 0.963, p < 0.05) in association with incubation time was quite similar with that in the PCA analysis, in which 77% of variation represented differences between the metabolite-transformation and dosedcontrol groups. Twenty-six features with variable importance in the project (VIP) value > 1 (Table S1) were discerned in the III and I quadrants, illustrating Cl-6:2 PFESA and potential metabolite candidates in elimination (DOWN) and generation (UP) trends with high constituent abundances, respectively. Laboratory purification of the 1H-6:2 PFESA and 1H-8:2 PFESA standards Approximately 1.0 g of F-53B (solved in 10 ml methanol) was added into 40 ml of prepared super-reduced CCA solutions under anaerobic conditions. After an incubation time of 24 h, the solution was vaporized and remaining solid was resolved in 30 ml of ethyl acetate. Further washing was conducted by adding 30 ml of ultrapure water for 3 times to remove inorganic salts. After the ethyl acetate solvent vaporization, remaining solid was resolved in 10 ml of acetonitrile as product solution for further purification. An Waters Autopurification HPLC-MS System (Waters Inc., Milford, MA), including a System Fluids Organizer, a 2545 Binary Gradient Module, a 2767 Sample Manager, a 515 Makeup Pump and an ACQUITY SQD single-quadrupole MS detector, was used to generate the 1H-6:2 PFESA and 1H-8:2 PFESA standards. Analytes separation was achieved by an XBridge C18 column (Waters, 19 mm i.d. 150 mm length, 5 μm), using acetonitrile and ultrapure water (with 0.05% ammonium hydroxide additive) as mobile phases. Flow rate was set at 20 ml/min, and 500 μl of sample was injected in each separation cycle. The initial flow gradient comprised 35% of acetonitrile and then S7

linearly increased to 45% in 2.5 min. Fraction collection time was confirmed by the single-quadrupole MS detector. 1H-6:2 PFESA and 1H-8:2 PFESA were collected with retention time in the range of 1.1 1.45 min and 1.55 1.70 min, respectively (Figure S11). Both the collected fractions were lyophilized and remaining solids were obtained. The molecular structures and purities of collected 1H-6:2 PFESA and 1H-8:2 PFESA standards were validated by a nuclear magnetic resonance spectrometer ( 1 H-NMR and 19 F-NMR, Bruker AVANCE III 500WB, Billerica, MA) and HPLC coupled to evaporative light-scattering detector (Shimadzu LC20A-ELSD II, Kyoto, Japan). The detailed information was shown in Figure S12 and S13. Purities of the 1H-6:2 PFESA and 1H-8:2 PFESA standards were all > 95%. Spike recovery experiments in river water and sediment samples Blank river water samples (n = 3) were used to assess the spike recovery of target PFASs. Briefly, 1 ng of each native standard (C6 C12 PFCAs, C4 C10 PFSAs, 4:2/6:2/8:2 FTSA, Cl-6:2/8:2 PFESA and 1H-6:2/8:2 PFESA) in 20 μl of methanol was spiked in 200 ml of river water samples, reaching a final concentration of 5 ng/l for each analyte. The spiked samples were allowed to equilibrate for 24 h and then pretreated according to the procedure described in sampling and pretreatment procedures section in the Materials and Methods. Blank sediment samples (n = 3) were also used for spike recovery of target PFASs. In brief, 1.0 g of sediment was soaked with 600 μl of methanolic solution containing 1 ng of each native standard (C6 C12 PFCAs, C4 C10 PFSAs, 4:2/6:2/8:2 FTSA, Cl-6:2/8:2 PFESA and 1H-6:2/8:2 PFESA). The soaked sediment samples were homogenized and dried using nitrogen gas. After aging for 72 h in room temperature, an alkaline S8

extraction method was used as described in sampling and pretreatment procedures section in the Materials and Methods. An external calibration curve was applied to calculate the final concentrations of target PFASs in sample extracts. The spike recoveries for target PFASs in river water and sediment samples were summarized in Table S6. S9

References 1. Melcher, J.; Olbrich, D.; Marsh, G.; Nikiforov, V.; Gaus, C.; Gaul, S.; Vetter, W. Tetra- and tribromophenoxyanisoles in marine samples from Oceania. Environ. Sci. Technol. 2005, 39 (20), 7784-7789; DOI 10.1021/051090g. 2. Ruppe, S.; Neumann, A.; Diekert, G.; Vetter, W. Abiotic transformation of toxaphene by superreduced Vitamin B12 and dicyanocobinamide. Environ. Sci. Technol. 2004, 38 (11), 3063-3067; DOI 10.1021/es034994f. 3. Bijlsma, S.; Bobeldijk, I.; Verheij, E.R.; Ramaker, R.; Kochhar, S.; Macdonald, I.A.; van Ommen, B.; Smilde, A.K. Large-scale human metabolomics studies: A strategy for data (pre-) processing and validation. Anal. Chem. 2006, 78 (2), 567-574; DOI 10.1021/ac051495j. 4. Liu, Y.; Dos Santos Pereira, A.; Martin, J.W. Discovery of C5-C17 poly- and perfluoroalkyl substances in water by in-line SPE-HPLC-Orbitrap with in-source fragmentation flagging. Anal. Chem. 2015, 87 (8), 4260-4268; DOI 10.1021/acs.analchem.5b00039. 5. Myers, A.L.; Jobst, K.J.; Mabury, S.A.; Reiner, E.J. Using mass defect plots as a discovery tool to identify novel fluoropolymer thermal decomposition products. J. Mass Spectrum. 2014, 49 (4), 291-296; DOI 10.1002/jms.3340. S10

Table S1. Detailed information on the 26 features generated in the non-target screening workflow with VIP threshold > 1. Feature ID Fold of change p value Trend Measured RT b Molecular formula Averaged IR c Isotopes MIM a (minutes) ( [M-H] - ) M447T6_3 38.33 1.00 10-5 UP 446.9372 6.84 2.1 10 6 [M] - C7HF14SO4 (1H-5:2 PFESA) M459T6_5 214.32 1.48 10-5 UP 458.9372 6.92 3.2 10 5 [M] - C8HF14SO4 (1H-6:2 PFUESA) M481T7_2 2.61 4.72 10-5 DOWN 480.8983 7.53 d 9.2 10 7 [M] - ClC7F14SO4 (Cl-5:2 PFESA) M483T7_2 2.63 4.36 10-5 DOWN 482.8949 7.53 3.4 10 7 [M+2] - M497T7_1 29.32 7.20 10-6 UP 496.8689 7.79 5.8 10 5 [M] - M497T6 14.10 1.74 10-6 UP 496.9338 7.19 d 5.7 10 9 [M] - C8HF16SO4 (1H-6:2 PFESA) M498T6 14.14 1.80 10-6 UP 497.9365 7.19 5.2 10 8 [M+1] - M499T6_3 13.86 1.98 10-6 UP 498.9293 7.19 2.3 10 8 [M+2] - M500T6_1 14.06 1.84 10-6 UP 499.9326 7.19 2.0 10 7 [M+3] - M531T7_2 2.20 1.29 10-4 DOWN 530.8949 7.85 d 2.9 10 9 [M] - ClC8F16SO4 (Cl-6:2 PFESA) M532T7_2 2.21 1.18 10-4 DOWN 531.8977 7.85 2.6 10 8 [M+1] - M533T7_2 2.19 1.31 10-4 DOWN 532.8916 7.85 1.1 10 9 [M+2] - M534T7 2.21 1.05 10-4 DOWN 533.8947 7.85 9.0 10 7 [M+3] - M535T7_2 2.21 1.01 10-4 DOWN 534.8871 7.85 3.7 10 7 [M+4] - M531T8 2.65 2.03 10-1 DOWN 530.8951 9.03 2.3 10 7 [M] - S11

M597T7 2.56 7.34 10-4 UP 596.9277 7.81 9.1 10 7 [M] - C10HF20SO4 (1H-8:2 PFESA) M191T1_2 1.50 5.96 10-7 DOWN 191.0193 1.25 2.7 10 7 [M] - C6H7O7 (citric acid) M1012T6 84.19 5.08 10-6 UP 1011.9022 7.17 d 2.9 10 8 [M] - C16H6F32S2O8N (NH4 + dimer of 1H-6:2 PFESA) M1013T6 83.93 5.87 10-6 UP 1012.9054 7.17 5.3 10 7 [M+1] - M1014T6 88.72 5.72 10-6 UP 1013.8988 7.17 2.7 10 7 [M+2] - M1017T6 23.92 1.49 10-7 UP 1016.8579 7.17 1.0 10 7 [M] - C16H2F32S2O8Na (Na + dimer of 1H-6:2 PFESA) M1053T6 3.82 3.84 10-11 UP 1052.9287 7.17 1.9 10 7 [M] - M191T1_1 204.39 1.73 10-12 UP 190.9934 1.09 1.1 10 7 [M] - M479T6_4 197.44 6.66 10-6 UP 478.9433 6.96 2.6 10 7 [M] - C8H2F15SO4 (2H-6:2 PFESA) M497T7_3 22.85 1.21 10-3 UP 496.9341 7.95 5.9 10 7 [M] - M499T6_4 12.21 1.37 10-6 UP 498.9382 7.17 3.7 10 7 [M] - a MIM: monoisotopic mass. b RT: retention time. c IR: instrumental response. d Features of the same retention behaviors were isotope clusters ([M] -, [M+1] -, [M+2] -, [M+3] - ) of the same compound. S12

Table S2. Homodimers of Cl-6:2 PFESA and 1H-6:2 PFESA in the 2-fold diluted supernatants in the super-reduced CCA assay. Molecular formula Theoretical RT Mass error Adduct type MIM ( [M-H] - ) MIM (min) (ppm) Homodimers of 1H-6:2 PFESA C 16 H 6 F 32 S 2 O 8 N [2M-2H+NH 4 ] - 1011.9022 1011.9029 7.17-0.69 C 16 H 2 F 32 S 2 O 8 Na [2M-2H+Na] - 1016.8579 1016.8583 7.17-0.39 C 16 H 3 F 32 S 2 O 8 [2M-H] - 994.8759 994.8764 7.18-0.50 Homodimers of Cl-6:2 PFESA Cl 2 C 16 H 4 F 32 S 2 O 8 N [2M( 35 Cl)-2H+NH 4 ] - 1079.8235 1079.8250 7.85-1.39 Cl 2 C 16 F 32 S 2 O 8 Na [2M( 35 Cl)-2H+Na] - 1084.7794 1084.7804 7.85-0.92 Cl 2 C 16 HF 32 S 2 O 8 [2M( 35 Cl)-H] - 1062.7980 1062.7984 7.85-0.38 S13

Table S3. Detailed information (acronyms, chemical names, molecular structures, theoretical monoisotopic masses, retention behaviors and characteristic fragmentation ions) of per- and polyfluoroalkyl substances in the suspect screening procedure. Acronym Chemical name Molecular structure Theoretical MIM RT MS 2 fragmentation ions Perfluoroalkyl carboxylates (PFCAs) PFHxA Perfluorohexanoate [F(CF2)5COO] - 312.9728 6.20 [C5F11] -, [C2F5] - PFHpA Perfluoroheptanoate [F(CF2)6COO] - 362.9696 6.84 [C6F13] -, [C3F7] - PFOA Perfluorooctanoate [F(CF2)7COO] - 412.9664 7.31 [C7F15] -, [C3F7] - PFNA Perfluorononanoate [F(CF2)8COO] - 462.9632 7.69 [C8F17] -, [C4F9] - PFDA Perfluorodecanoate [F(CF2)9COO] - 512.9600 8.06 [C9F19] -, [C5F11] - PFUdA Perfluoroundecanoate [F(CF2)10COO] - 562.9568 8.49 [C10F21] -, [C5F11] - PFDoA Perfluorododecanoate [F(CF2)11COO] - 612.9537 9.04 [C11F23] -, [C6F13] - Perfluoroalkyl sulfonates (PFSAs) PFBS Perfluorobutane sulfonate [F(CF2)4SO3] - 298.9430 5.45 [SO3] -, [FSO3] - PFHxS Perfluorohexane sulfonate [F(CF2)6SO3] - 398.9366 6.89 [SO3] -, [FSO3] - PFOS Perfluorooctane sulfonate [F(CF2)8SO3] - 498.9302 7.69 [SO3] -, [FSO3] - PFDS Perfluorodecane sulfonate [F(CF2)10SO3] - 598.9238 8.47 [SO3] -, [FSO3] - Fluorotelomer sulfonates (FTSAs) S14

4:2 FTSA 4:2 Fluorotelomer sulfonate [F(CF2)4(CH2)2SO3] - 326.9743 6.12 [C6F8H3SO3] -, [HSO3] - 6:2 FTSA 6:2 Fluorotelomer sulfonate [F(CF2)6(CH2)2SO3] - 426.9679 7.30 [C8F12H3SO3] -, [HSO3] - 8:2 FTSA 8:2 Fluorotelomer sulfonate [F(CF2)8(CH2)2SO3] - 526.9615 8.07 [C10F16H3SO3] -, [HSO3] - Chlorinated polyfluoroalkyl ether sulfonates (Cl-PFESAs) Cl-5:2 PFESA 5:2 Chlorinated polyfluoroalkyl ether sulfonate [Cl(CF2)5O(CF2)2SO3] - 480.8988 7.52 [C5F10ClO] -, [FSO2] -, [FSO3] - Cl-6:2 PFESA 6:2 Chlorinated polyfluoroalkyl ether sulfonate [Cl(CF2)6O(CF2)2SO3] - 530.8956 7.87 [C6F12ClO] -, [FSO2] -, [FSO3] - Cl-7:2 PFESA 7:2 Chlorinated polyfluoroalkyl ether sulfonate [Cl(CF2)7O(CF2)2SO3] - 580.8924 8.24 [C7F14ClO] -, [FSO2] -, [FSO3] - Cl-8:2 PFESA 8:2 Chlorinated polyfluoroalkyl ether sulfonate [Cl(CF2)8O(CF2)2SO3] - 630.8892 8.70 [C8F16ClO] -, [FSO2] -, [FSO3] - Cl-10:2 PFESA 10:2 Chlorinated polyfluoroalkyl ether sulfonate [Cl(CF2)10O(CF2)2SO3] - 730.8828 9.10 [C10F20ClO] -, [FSO2] -, [FSO3] - Hydrogen-substituted polyfluoroalkyl ether sulfonates (H-PFESAs) 1H-5:2 PFESA 5:2 Hydrogen-substituted polyfluoroalkyl ether sulfonate [H(CF2)5O(CF2)2SO3] - 446.9377 6.84 [C5HF10O] -, [C5F9O] -, [C4F7] -, [FSO2] - 1H-6:2 PFESA 6:2 Hydrogen-substituted polyfluoroalkyl ether sulfonate [H(CF2)6O(CF2)2SO3] - 496.9346 7.20 [C6HF12O] -, [C6F11O] -, [C5F9] -, [FSO2] - 1H-7:2 PFESA 7:2 Hydrogen-substituted polyfluoroalkyl ether [H(CF2)7O(CF2)2SO3] - 546.9314 - - sulfonate 1H-8:2 PFESA 8:2 Hydrogen-substituted polyfluoroalkyl ether sulfonate [H(CF2)8O(CF2)2SO3] - 596.9282 7.81 [C8HF16O] -, [C8F15O] -, [C7F13] -, [FSO2] - S15

Table S4. Instrumental parameters on chromatographic separation and mass spectrometry. Instrument Analytical Column Ultimate 3000 ultrahigh performance liquid chromatography tandem Orbitrap Fusion mass spectrometer (Thermo Fisher Scientific Inc., Waltham, MA) equipped with a heated electrospray source. The mass spectrometer was operated in negative mode. ACQUITY BEH UPLC C18 (2.1 mm i.d. 100 mm length, 1.7 um, Waters) Column Temperature 35 C Mobile Phases A: 1mM NH4Ac in H2O B: 1mM NH4Ac in methanol Gradient Profile Time (min) Flow rate (ml/min) Percentage A (%) Percentage B (%) 0 0.3 75 25 1 0.3 75 25 6 0.3 20 80 7 0.3 20 80 10 0.3 0 100 15 0.3 0 100 15.1 0.3 75 25 20 0.3 75 25 Injection Volume 5μL S16

Orbitrap HRMS Parameters General instrumental parameters: Spray Voltage: -2500 V Ion Transfer Tube Temperature: 350 C Vaporizer Temperature: 200 C Sheath Gas: 35 Arb Aux Gas: 10 Arb Sweep Gas: 1 Arb Instrumental parameters for MS 1 scanning: Orbitrap Resolution: 120000 Mass Range: Normal Scan Range (m/z): 150 1500 RF Lens (%): 60 Automatic gain control (AGC) Target: 2.0 10 5 Maximum Injection Time (ms): 100 Instrumental parameters for MS 2 scanning: Isolation Mode: Quadrupole Isolation Window (m/z): 1 Activation Type: HCD HCD Collision Energy (%): 20 60 Detector Type: Orbitrap Orbitrap Resolution: 60000 Mass Range: Normal Scan Range: 50 1500 RF Lens (%): 60 AGC Target: 5.0 10 4 Maximum Injection Time (ms): 100 Instrumental parameters for MS 3 scanning: MS Isolation Mode: Quadrupole MS Isolation Window (m/z): 2 S17

MS Activation Type: HCD MS HCD Collision Energy (%): 30 MS 2 Isolation Window (m/z): 2 MS 2 Activation Type: HCD MS 2 HCD Collision Energy (%): 30 Detector Type: Orbitrap Orbitrap Resolution: 60000 Mass Range: Normal Scan Range: 50 500 RF Lens (%): 60 AGC Target: 5.0 10 4 Maximum Injection Time (ms): 100 S18

Table S5. Method quantification limits (MQL) of all target analytes in river water and sediment samples. Analyte River water (pg/l) Sediment (pg/g) Surrogate standard PFHxA 218 16 MPFHxA PFHpA 58 14 M4PFHpA PFOA 213 13 MPFOA PFNA 68 12 MPFNA PFDA 18 11 MPFDA PFUdA 15 10 MPFUdA PFDoA N.D. a 15 MPFDoA PFBS 175 20 MPFHxS PFHxS 112 32 MPFHxS PFOS 172 37 MPFOS PFDS N.D. N.D. MPFOS 4:2 FTSA N.D. N.D. M2-6:2 FTSA 6:2 FTSA 40 10 M2-6:2 FTSA 8:2 FTSA 35 14 M2-6:2 FTSA Cl-6:2 PFESA 20 16 MPFOS Cl-8:2 PFESA 16 13 MPFOS 1H-6:2 PFESA 15 10 MPFOS 1H-8:2 PFESA 14 9 MPFOS a N.D.: not detected S19

Table S6. Spike recoveries of target analytes in river water and sediment samples. River water (mean ± SD a, %, n = 3) Sediment (mean ± SD a, %, n = 3) PFHxA 72 ± 2 77 ± 17 PFHpA 74 ± 5 71 ± 4 PFOA 86 ± 17 84 ± 5 PFNA 86 ± 5 91 ± 6 PFDA 80 ± 12 89 ± 6 PFUdA 72 ± 10 88 ± 9 PFDoA 67 ± 4 79 ± 11 PFBS 70 ± 5 82 ± 6 PFHxS 78 ± 3 73 ± 2 PFOS 69 ± 8 71 ± 2 PFDS 69 ± 10 58 ± 8 4:2 FTSA 95 ± 7 137 ± 13 6:2 FTSA 95 ± 12 172 ± 10 8:2 FTSA 105 ± 10 137 ± 13 Cl-6:2 PFESA 68 ± 9 82 ± 1 Cl-8:2 PFESA 65 ± 6 57 ± 10 1H-6:2 PFESA 72 ± 5 70 ± 5 1H-8:2 PFESA 69 ± 10 63 ± 5 a SD: standard deviation. S20

Table S7. Recoveries of surrogate standards and matrix effects of injection standards in river water and sediment samples. Recoveries (mean ± SD a, %, n = 30) Matrix effects (mean ± SD, %, n = 30) River water Sediment River water Sediment MPFHxA 71 ± 8 78 ± 8 M5PFHxA 93 ± 5 90 ± 5 MPFOA 82 ± 5 79 ± 7 M6PFDA 86 ± 8 84 ± 8 MPFNA 76 ± 6 70 ± 9 M3PFHxS 93 ± 2 90 ± 7 MPFDA 83 ± 6 75 ± 9 M8PFOS 95 ± 2 88 ± 9 MPFUdA 72 ± 5 70 ± 8 MPFDoA 74 ± 9 73 ± 13 MPFHxS 78 ± 3 74 ± 10 MPFOS 108 ± 4 77 ± 6 M2-6:2 FTSA 100 ± 5 86 ± 10 a SD: standard deviation. S21

Analyte Table S8. Descriptive statistics of identified per- and polyfluoroalkyl substances in the sampling regions. Range (pg/l) River water GM a (pg/l) Fenghuajiang River (n = 34) Pan River (n = 26) Sediment Range (ng/g, d.w. b ) GM (pg/g, d.w.) DF c (%) AC d (%) Range (pg/l) River water Sediment GM (pg/l) Range (pg/g, d.w.) GM (pg/g, d.w.) Perfluoroalkyl carboxylates (PFCAs) PFHxA (3.24 5.09) 10 3 4.00 10 3 N.D. 877 49.2 68 5 < MQL e 2.40 10 3 1.14 10 3 N.D. < MQL N.D. 54 3 PFHpA 935 3.23 10 3 2.29 10 3 N.D. N.D. 50 1 236 1.03 10 3 683 N.D. N.D. 50 2 PFOA (13.7 148) 10 3 6.36 10 4 N.D. 928 177 85 30 (1.89 21.3) 10 3 5.87 10 3 26.4 141 55.3 100 22 PFNA N.D. 1.24 10 3 509 N.D. N.D. 41 0 152 773 327 N.D. 51.4 9.75 58 1 PFDA N.D. 354 38.0 N.D. N.D. 18 0 N.D. 500 180 N.D. 95.6 17.1 77 2 PFUdA N.D. N.D. N.D. N.D. 0 0 N.D. 259 34.0 N.D. 61.4 11.6 46 1 PFDoA N.D. N.D. N.D. N.D. 0 0 N.D. N.D. N.D. 23.4 11.3 12 0 Perfluoroalkyl sulfonates (PFSAs) PFBS (4.23 9.94) 10 3 7.56 10 3 N.D. 480 26.1 59 4 N.D. 2.77 10 3 634 N.D. N.D. 35 2 PFHxS (3.11 113) 10 3 3.05 10 4 N.D. 278 137 91 14 528 9.32 10 3 1.52 10 3 N.D. 73.8 51.1 58 5 PFOS 663 1.08 10 4 3.38 10 3 < MQL 609 165 100 4 (1.52 17.5) 10 3 3.85 10 3 87.6 630 254 100 34 PFDS N.D. N.D. N.D. N.D. 0 0 N.D. N.D. N.D. N.D. 0 0 Fluorotelomer sulfonates (FTSAs) 4:2 FTSA N.D. N.D. N.D. N.D. 0 0 N.D. N.D. N.D. N.D. 0 0 6:2 FTSA N.D. 2.09 10 3 649 N.D. N.D. 47 0 176 9.87 10 3 807 13.8 40.2 23.2 100 6 8:2 FTSA N.D. N.D. N.D. N.D. 0 0 N.D. 198 35.0 N.D. 33.2 11.1 23 0 Chlorinated polyfluoroalkyl ether sulfonates (Cl-PFESAs) Cl-6:2 PFESA (4.37 77.0) 10 3 1.93 10 4 320 7.24 10 3 1.77 10 3 100 33 590 5.66 10 3 1.64 10 3 46.1 738 149 100 18 Cl-8:2 PFESA N.D. N.D. N.D. 3.45 10 3 379 47 8 N.D. 290 33.3 N.D. 80.0 37.2 69 2 Hydrogen-substituted polyfluoroalkyl ether sulfonates (H-PFESAs) 1H-6:2 PFESA N.D. 3.31 10 3 799 N.D. 503 12.0 53 1 97.3 1.25 10 3 352 19.2 146 10.0 92 3 1H-8:2 PFESA N.D. N.D. N.D. 165 7.71 3 0 N.D. 66.0 12.5 N.D. 21.6 7.66 54 0 a GM: geometric mean concentration. b D.W.: dry weight. c DF: detection frequency. d AC: average composition. e MQL: method quantification limit DF (%) AC (%) S22

Table S9. Spearman s correlation analysis of quantified PFAS concentrations in river water samples from the Fenghuajiang River. PFHpA a PFOA PFNA PFBS PFHxS PFHpS PFOS 6:2 FTSA Cl-6:2 PFESA 1H-6:2 PFESA PFHxA -0.471-0.289-0.327-0.341-0.299-0.343-0.363-0.255-0.370-0.363 PFHpA 0.790 ** 0.636 ** 0.662 ** 0.771 ** 0.781 ** 0.670 ** 0.497 * 0.673 ** 0.746 ** PFOA 0.644 ** 0.833 ** 0.968 ** 0.978 ** 0.887 ** 0.784 ** 0.902 ** 0.979 ** PFNA 0.706 ** 0.543 * 0.589 * 0.818 ** 0.563 * 0.794 ** 0.630 ** PFBS 0.811 ** 0.802 ** 0.863 ** 0.814 ** 0.875 ** 0.820 ** PFHxS 0.965 ** 0.799 ** 0.728 ** 0.828 ** 0.934 ** PFHpS 0.848 ** 0.751 ** 0.867 ** 0.952 ** PFOS 0.809 ** 0.995 ** 0.899 ** 6:2 FTSA 0.801 ** 0.749 ** Cl-6:2 PFESA 0.914 ** a Analytes with detection frequency less than 70% in the river water samples were not included. * and ** Significant correlations at 0.05 and 0.01 levels, respectively. S23

Figure S1. Negligible changes of Cl-6:2 PFESA and 1H-6:2 PFESA amount in an additional incubation period of up to 40 min when 3.6 ml of methanol was added in the super-reduced CCA incubation tubes at appointed incubation time, showing transformation reaction effectively retarded. S24

Figure S2. The sampling map showing spatial distribution of Cl-6:2 PFESA, 1H-6:2 PFESA, Cl-8:2 PFESA and 1H-8:2 PFESA in river water and sediment samples in Pan River in Shandong Province. (Pink pentacle, metal-plating manufactory; black tetragon, sampling sites for river water and sediment samples). S25

Figure S3. Non-target screening workflow for generation, filtering, ranking and structure confirmation of potential metabolites in Cl-6:2 PFESA reductive transformation process. S26

(A) (B) S27

(C) Figure S4. Results of principal component analysis (PCA, p < 0.05) show a clear separation of the metabolite-transformation and dosed-control dataset groups, which were illuminated by the red and blue dots, respectively. A. Kruskal s non-metric multidimensional scaling presents distinct distribution of samples in metabolite transformation group in association with incubation time; B. Score plots of PCA analysis; C. R 2 and Q 2 represent goodness of fit and prediction of the three primary factors in the statistical analysis procedures. S28

(A) (B) S29

(C) (D) Figure S5. Results of orthogonal partial least-squares-discriminant analysis (OPLS-DA, p < 0.05) show a clear separation of the metabolite-transformation and dosed-control dataset groups, which were illuminated by the red and blue dots, respectively. A. R 2 (cum) and Q 2 (cum) represent goodness of fit and prediction in the statistical analysis procedures; B. Score Scatter Plot represents distinct distribution of samples in metabolite-transformation group in association with incubation time; C. Twenty-six features were identified with VIP values > 1; D. Distribution of the identified 26 features in the III and I quadrants of the S-Plot, illustrating the Cl-6:2 PFESA and potential metabolite candidates in elimination (DOWN) and generation (UP) trends with high constituent abundances, respectively. S30

Figure S6. MS 2 fragmentation patterns of the Cl-PFESA and H-PFESA standards (A. Cl-6:2 PFESA; B. 1H-6:2 PFESA; C. Cl-8:2 PFESA; D. 1H-8:2 PFESA). Solid-line arrows represent characteristic neutral loss of HF, C2F4SO3 and CF2O in the HCD fragmentation process. S31

Figure S7. Reconstructed total ion chromatography of deprotonated molecular ions of the dosed Cl-6:2 PFESA and proposed transformation products in both standard solution (10 ng/ml in methanol) and supernatant in the super-reduced CCA assay. Mass windows were set as theoretical monoisotopic mass ± 5 ppm. Instrumental responses (IRs) in the supernatant represented metabolite contents in samples with incubation time of 50s. S32

Figure S8. MS 2 fragmentation patterns of 2H-6:2 PFESA (A. HCF2(C5HF9)OC2F4SO3 - ) and 1H-6:2 PFUESA (B. HCF2(C5F8)OC2F4SO3 - ) in the HCD mode in the superreduced CCA assay with sample incubation time of 50s. Solid-line arrows represent characteristic neutral loss of HF, C2F4SO3 and CF2O in the HCD fragmentation process. S33

Figure S9. MS 3 fragmentation pattern of [C6HF12O] - generated from MS 2 of 1H-6:2 PFESA, and MS 2 spectra for homodimers of Cl-6:2 PFESA and 1H-6:2 PFESA in HCD mode. (A. [C6HF12O] - ; B. [2M-2H+Na] - homodimer of 1H-6:2 PFESA; C. [2M- 2H+NH4] - homodimer of Cl-6:2 PFESA) in the super-reduced CCA assay with sample incubation time of 50s. Solid-line arrows represent characteristic neutral loss of HF and CF2O in the HCD fragmentation process. S34

Figure S10. Tentative molecular structures of 2H-6:2 PFESA (CL: Level 2b) and 1H- 6:2 PFUESA (CL: Level 3). S35

Figure S11. Retention time of 1H-6:2 PFESA and 1H-8:2 PFESA in the LC column of Autopurification HPLC-MS system. S36

S37

S38

S39

Figure S12. 1 H-NMR and 19 F-NMR spectrum of laboratory-purified 1H-6:2 PFESA and 1H-8:2 PFESA standards. (A. 1 H-NMR of 1H-6:2 PFESA; B. 19 F-NMR of 1H-6:2 PFESA; C. 1 H-NMR of 1H-8:2 PFESA; D. 19 F-NMR of 1H-8:2 PFESA) S40

S41

Figure S13. Detailed information on the purity of the 1H-6:2 PFESA and 1H-8:2 PFESA standards based on the LC-ELSD method. (A. 1H-6:2 PFESA; B. 1H-8:2 PFESA) S42

Figure S14. Extraction efficiency of target analytes spiked in blank sediment samples. Each sample was extracted for three times and each extract was analyzed individually. Only about 2% of the target analytes were recovered in the third extraction, indicating duplicate extraction as performed in our experiment could reach sufficient extraction for all analytes. S43

Figure S15. Retention behaviors of 1H-6:2 PFESA, linear-pfos and Cl-6:2 PFESA on reversed C18 HPLC column. MS channels were generated by injection of standard solution (10 ng/ml in methanol). S44