TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Similar documents
Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Headspace Technology for GC and GC/MS: Features, benefits & applications

Application. Gas Chromatography February Introduction

Determination of Volatile Substances Proof of Food Adulteration

Analysis of BTEX in Natural Water with SPME

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

ChromTech options for PAL systems

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Understanding Gas Chromatography

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Introduction to Capillary GC

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Methanol Extraction of high level soil samples by USEPA Method 8260C

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Tar measurement by the Solid Phase Adsorption (SPA) method

Chemistry Instrumental Analysis Lecture 27. Chem 4631

PAL SPME Arrow The Better SPME

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

PAL SPME Arrow The Better SPME

Solid Phase Microextraction

Selection of a Capillary GC Column

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Selection of a Capillary

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

Determination of 24 PAHs in Drinking Water

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Analytical Trap Comparison for USEPA Method 8260C

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

GAS CHROMATOGRAPHY (GC)

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Extraction and analysis of polycyclic aromatic hydrocarbons (PAHs) by solid phase micro-extraction/supercritical fluid chromatography (SPME/SFC)

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Petrochemical. Transformer Oil Gas Analysis - TOGA

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

AUTOMATED HEADSPACE. Headspace Principles. Graham Broadway. Headspace Gas Chromatography Background to the HS Technique

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

Activity in the FID Detection Port: A Big Problem if Underestimated

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Maximizing Sample Throughput In Purge And Trap Analysis

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Optimizing. Abstract: is standardd. procedures. altered to

Gas Chromatography (GC)

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Chemical Analysis Problem

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

Application Note. Abstract. Authors. Introduction

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

ION CHROMATOGRAPHY SYSTEM S 150

Theory and Instrumentation of GC. Sampling Techniques

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

COMBI. Gaschromatography. GC / GC-MS sample injector grows with your needs

Introduction to Capillary GC

high performance OPTIC 3 and applications a total analytical solution

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal Desorption Coupled with GC MS

Introduction to Gas Chromatography

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Transcription:

ROBOKROM 1 TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview ROBOKROM 2 +8 OPERATIONAL MODES HRGC+HRGC-MS HRGC+HPLC-MS STATIC HEAD SPACE PURGE & TRAP SMPE FRACTION COLLECTOR SAMPLE PREPARATION and THERMAL DESORBTION MAIN FEATURES X-Y-Z Displacements. Symmetrical Horizontal Arm: Microcontroller can be located at either side. Vertical Arm: helds the needles and all syringes. 3 Interchangeable Vial Trays: for 32 Vials of 6, 10 or 20ml, 105 Vials of 2ml and 171 Vials of 1ml. ROBOKROM 3 ROBOKROM 4 MAIN FEATURES HRGC AND HPLC AUTOSAMPLER Optional Tray Temperature Control (TTC): all vials can be heated or cooled from 5ºC to 70ºC in standby mode. Easy Menu Driven Interactive Programming or through KoniKontrol Software via Konikrom 32 Software. Accepts a wide range of syringes from 0,5 to 500µl. Programmable injection volume (from 0,1 to 500µl). Injection with solvent or air plug before and after the sample injection Programmable pluger speed from 1µl/s to 5ml/s depending on the syringe type. Handles wide range of sample viscosity. ROBOKROM 5 ROBOKROM 6

ROBOKROM 7 HRGC AND HPLC AUTOSAMPLER HRGC AND HPLC AUTOSAMPLER Adjustable plunger speed for syringe cleaning and injection. Programmable needle introduction speed for septum protection. Pre and post cleaning with different solvents. Free from carry-over effects. Pre-column derivatization. Internal standard addition. Dual channel/double injection: same or different samples. HPLC: fied loop or programmable from 0.1µl to 500µl. ROBOKROM 8 ROBOKROM AUTOSAMPLER WITH ACCESSORIES STATIC HEAD SPACE Theory Analysis of the vapour in equilibrium in a sample keep in a closed vial at constant temperature. Temperature range: from 40ºC to 190ºC. Solid or liquid samples are introduced in a sealed vial with an inert gas (at controlled pressure) in the head space. ROBOKROM 9 ROBOKROM 10 k = CºI/Cg The system is kept at constant temperature during a fied time until the volatile compounds reach the equilibrium between the matri and the head space. A fied volume of the head space is transferred to the GC injector through the proper heated line. CºI = Cg (Pt/Pºa Ya/Xa + Vg/Vi) Cg = CºI/k where: Cº I : initial concentration C g : product concentration in vapor phase P t : total pressure Pº a : vapor pressure of compound A at working temperature Tl Y a : vapor phase in equilibrium concentration X a : condensed phase in equilibrium concentration V g /V i : volume ratio liquid / vapor phase ROBOKROM 11 ROBOKROM 12

ROBOKROM 13 Vapor phase concentration will be higher when: When Pºa is higher: temperature proportional. When the volume ratio Vg/Vi is lower. When total pressure is lower. In aqueous samples: increasing the ionic strength of water (by addition of inorganic salt) In non-aqueous samples by water-miscible: adding water to transfer the organic compounds from aqueous matri to vapor phase. Concentration vs. Desorbtion Time: ROBOKROM 14 ROBOKROM IN STATIC HEAD SPACE MODE WHEN DO WE USE HEAD SPACE? When direct injection is not possible. When results are better than direct injection (depends on compound/matri). Samples that need a previous etraction (alcohol in blood, water pollutants, etc.). When analyzing only volatile compounds (food, beverages, perfumes, ). ROBOKROM 15 ROBOKROM 16 WHEN DO WE USE HEAD SPACE? Advantage The non volatile compounds are not introduced in the GC System. Better sensitivity. Sample preparation is not needed. Disadvantage Quantification is done only in the vapor phase. Quantification problems (internal standard). Special equipment. ROBOKROM : HS MODE Temperature Control in 3 different blocks: tray, pre desorption and desorption (up to 300ºC) 32 vials of 6, 10 or 20ml Different Injection Volumes: Programmable Injection Time All temperatures and times programmable Magnetic Vial Movement ROBOKROM 17 ROBOKROM 18

ROBOKROM 19 ROBOKROM _ HS MODE HS WORKING CYCLES Electronic Pressure Control (EPC) for vial pressurization Optional Sample Stirring Maimum Productivity with working cycle optimization Optional fied loop sampling 1. INITIAL 2. DESORPTION INITIAL TEMP. DESORP. TEMP. ROBOKROM 20 HS WORKING CYCLES TRIHALOMETANES IN WATER INJECTION TIME 3. INJECTION 4. CLEANING TEMP. SAMPLE 0.5 ppm THMs GC Column: J&W- DB-624, 30m, 0.53mm, 3µm (ref.: 125-1334) Carrier: He; constant Flow 8 ml/min Injector: 250ºC, inj. mode: conventional injector Oven: 35ºC (1min); 18ºC/min; 70ºC (0min); 5ºC/min; 150ºC (1min) Detector: ECD 300ºC; detector gases: N2 at at N2 60ml/min 32vials of of 10ml; ambient temperature HeadSpace: Tray: 80ºC T desorb: T line: 160ºC T valve: 160ºC t desorb: 10min t inj: 20s Cleaning He 8psi gas: ROBOKROM 21 ROBOKROM 22 DYNAMIC HEAD SPACE (PURGE AND TRAP) _ THEORY Determination of volatile compounds in liquid samples. A sample volume is inserted into a sealed vial and a gas flow is bubbled through it. The outlet gas is trapped in the adsorbent (trap). The trap is desorbed transferring the compounds by means of the carrier gas through the GC system. DYNAMIC HEAD SPACE (PURGE AND TRAP) _ THEORY Any compound has its vapor pressure Compounds migrate out of the solution to reach the equilibrium As the compound in the vapor phase are constantly get out due to the gas flow, the equilibrium is never reached (dynamic equilibrium) ROBOKROM 23 ROBOKROM 24

ROBOKROM 25 DYNAMIC HEAD SPACE (P&T) DYNAMIC HEAD SPACE AUTOSAMPLER 32 vials of 6, 10 or 20 ml. Optional Tray Temperature Control 32 vials of 6, 10 or 20ml Optional Tray Temperature Control (5ºC-70ºC) All parameters are user programmable: purge time, pre-injection time, desorption time,... All Temperatures programmables: transfer line, valve, initial trap, desorp. trap, baked trap,... Electronic Flow Control (EPC) for purge volume measurement Trap Temperature: from 190ºC (cryogenic option) up to 400ºC All traps available: tena, silica gel, charcoal, mitures,... ROBOKROM 26 PURGE & TRAP AUTOSAMPLER PURGE & TRAP WORKING CYCLES 1. INITIAL 2. PURGE 3. DESORBTION & VENTILATION 4. CLEANING TRAP (INITIAL TEMP) PURGE TIME TRAP (PURGE TEMP) DESORB. TIME TRAP (DESORB. TEMP) BAKE TIME TRAP (BAKE TEMP) PURGE FLOW SAMPLE BAKE FLOW BAKE FLOW ROBOKROM 27 ROBOKROM 28 BTEX IN WATER SPME AUTOSAMPLER Rt (min) RSD Rt RSD Area MDL (n=10) (n=10) (ppt) BENZENE 5.123 0.39 2.7 60 TOLUENE 7.803 0.32 3.3 8 ETHYLBENZENE 9.953 0.26 6.5 30 p,m- XYLENE 10.129 0.26 6.5 20 o- XYLENE 10.690 0.24 5.9 30 SAMPLE 6ppb 6ppb BTEX (n=10) GC GC Column: J&W- DB-624, 30m, 30m, 0.53mm, 3µm 3µm (ref.: (ref.: 125-1334) Carrier: He; He; constant Flow Flow 8ml/min Injector: 250ºC, inj. inj. mode: conventional injector Oven: 35ºC 35ºC (min); 10ml/min; 200ºC (1min) Detector: 250ºC; detector gases: H2 at H2 at 38ml/min; Air Air at at 220ml/min Purge Tray: Tray: 32vials of of 20ml; 20ml; ambient temperature & Trap: Trap: Trap: Trap: BTEX Trap Trap from from Supelco 25ºC 25ºC T trap trap initial: T purge: 25ºC 25ºC // 20min Purge Flow: Flow: 40 40 ml/min 180ºC T predesorb: T desorb: 200ºC T line: line: 200ºC T valve: 200ºC t t desorb: 1min 1min Cleaning Temp: 220ºC // 10min Cleaning gas: gas: He He 40ml/min Easy and reliable etraction concentration method. Solvent saving. Allows sample concentration: liquid, solid and gas samples. High selectivity depending on etracting fiber. Temperature control (purge and desorption). Wide range of fibers. Optional sample stirring. ROBOKROM 29 ROBOKROM 30

ROBOKROM 31 SOLID PHASE MICROEXTRACTION _ THEORY SOLID PHASE MICROEXTRACTION _ THEORY COLOR CODE CONNECTION SEPTUM SEALING FERRULE FIBER SUPPORT SPRING SEPTUM DRUM NEEDLE Compounds are transferred from sample matri to phase bonded fiber. The etraction is completed when the equilibrium between compounds in sample and fiber is reached. Equilibrium sample preparation method. Direct Etraction - Immersion The fiber is in contact with the sample. The compound moves to the fiber where is adsorbed. The fiber is retracted and leaved to proceed to the desorption. PHASE FIBER SUPELCO CATALOG ROBOKROM 32 SOLID PHASE MICROEXTRACTION _ THEORY HS - SPME The fiber is in contact with the head space vapor. The compound moves to the fiber where is adsorbed. The fiber is retracted and leaved to proceed to the desorption. SPME AUTOSAMPLER 3 Interchangeable vial trays: for 32 Vials of 6, 10 or 20ml, 105 vials of 2ml and 171 Vials of 1ml. Optional Tray Temperature Control (TTC): all vials can be heated or cooled from 5ºC to 70ºC in stand-by mode. Syringe: Special fiber adapter. Fibers: all available fibers (PDMS, PDMS/Carboen, PDMS/DVB, CW/TPR, CW/DVB,...) Working mode: Immersion / HS. Optional (32 vial tray): Sample Stirring and Heating. ROBOKROM 33 ROBOKROM 34 SPmE AUTOSAMPLER FROM SUPELCO CATALOG ROBOKROM 35 ROBOKROM 36

ROBOKROM 37 PAH IN WATER FRACTION COLLECTOR AUTOSAMPLER Voltage [mv] [mv] 600 600 500 500 400 400 300 300 200 200 100 100 Naphtalene Acenaphtylene Acenaphtene Fluorene Anthracene Phenantrene Fluoranthrene Pyrene Benzo(a)anthracene Chrysene SAMPLE GC SPmE Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Column: Carrier: Injector: Oven: Indeno Indeno (1,2,3-d)pyrene Dibenzo(a,h)anthracene Benzo(ghi)perylene 200ppb Water spiked KAP- 1701, 30m, 0.32mm He; constant Flow 2 ml/ min 280ºC, inj. mode: Split/splitless (4 ; 1:20) 60ºC (4min); 10ºC/min; 290ºC (10min); Detector: FID 250ºC Tray: 32vials of of10ml; ambient temperature T Absorp.: 60ºC Fiber 100um polydimethylsiloane t t adsorb 15min, rapid stirring t t desorb: 4 min Automatic and sequential sample collecting by time. 32, 105 or 171 collectors. Optional baseline monitoring (UV-VIS). Automatic waste collection. Vials of 1, 2, 6, 10 or 20 ml. Intelligent volume calculation. 0 0 5 10 10 15 15 20 20 25 25 30 30 Time Time [min.] [min.] ROBOKROM 38 µstation AUTOSAMPLER FOR SAMPLE PREPARATION THERMAL DESORBER Automatic and sequential sample processing. Options: evaporation, concentration by volatilization, drying, concentration adjustment (controlled dosing of reagents, standards and/or solvents),... Utmost reproducibility, linearity, precision and accuracy. User Error free operation Reliable. Free from operator s errors. Purge & Trap with vial movement, heating and cryogenic option The Etraction cartridges are introduced in the 20 ml vials and heated up to 300ºC. The inert gas transfers the desorbed compounds to the cryogenic trap. When the transfer is finished the trap is heated and the compounds are transferred to the HRGC system. ROBOKROM 39 ROBOKROM 40