DESIGN OF A WIEN FILTER AND MEASUREMENT OF LONGITUDINAL POLARIZATION OF BETA PARTICLES BY S. S. ABHYANKAR AND M. R. BHIDAY

Similar documents
V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

Detection and measurement of gamma-radiation by gammaspectroscopy

THE COMPTON EFFECT Last Revised: January 5, 2007

Beta Spectrum. T β,max = kev kev 2.5 ms. Eγ = kev

UNIQUE SCIENCE ACADEMY

Quality Assurance. Purity control. Polycrystalline Ingots

2. Determine the excess charge on the outer surface of the outer sphere (a distance c from the center of the system).

Atomic and Nuclear Physics

Energy loss of alpha particles - Prelab questions

EXAMINATION QUESTIONS (6)

v = E B FXA 2008 UNIT G485 Module Magnetic Fields BQv = EQ THE MASS SPECTROMETER

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

2. A proton is traveling with velocity v, to the right, through a magnetic field pointing into the page as indicated in the figure below.

Radioactivity. Lecture 6 Detectors and Instrumentation

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Attenuation of Radiation in Matter. Attenuation of gamma particles

DOUBLE MOTT SCATTERING OF ELECTRONS SOVIET PHYSICS JETP VOLUME 17, NUMBER 4 OCTOBER, 1963

tip conducting surface

Alpha-Energies of different sources with Multi Channel Analyzer

object objective lens eyepiece lens

5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Received October 7, 1963

Bi β + Po Bismuth-214 is radioactive. It has a half-life of 20 minutes. (a) The nuclide notation for bismuth-214 is Bi.

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Physics. Student Materials Advanced Higher. Tutorial Problems Electrical Phenomena HIGHER STILL. Spring 2000

Radioactivity and Ionizing Radiation

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Introduction Polarimeters at MAMI Analysis Future Conclusion. Polarimetry at MAMI. V. Tyukin, Inst. of Nuclear Physics, Mainz, Germany

General Physics (PHY 2140)

General Physics (PHY 2140)

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Precision neutron flux measurement with a neutron beam monitor

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Particle Physics. Question Paper 1. Save My Exams! The Home of Revision. International A Level. Exam Board Particle & Nuclear Physics

Radiation Detection and Measurement

Secondary ion mass spectrometry (SIMS)

*GPH22* *28GPH2201* Science: Physics. Unit 2 Higher Tier [GPH22] FRIDAY 24 JUNE, MORNING *GPH22* TIME 1 hour 45 minutes.

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

Determination of e/m, mc 2, and the Relations Among Momentum, Velocity, and Energy of Relativistic Electrons

Determination of the timing properties of a pulsed positron lifetime beam by the application of an electron gun and a fast microchannel plate

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

(b) Which of these particles has the largest mass? (1) (c) The maximum range of a beta particle in air is about (1)

PHYSICS ASSIGNMENT ES/CE/MAG. Class XII

RADIOACTIVITY Q32 P1 A radioactive carbon 14 decay to Nitrogen by beta emission as below 14 x 0

100 Physics Facts. 1. The standard international unit (SI unit) for mass (m) is. kg (kilograms) s (seconds)

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Radiation Detection. 15 th Annual OSC Readiness Training Program.

The Mössbauer Effect

EEE4106Z Radiation Interactions & Detection

The Compact Muon Beam Line

Physics 202 Final (Monday, December 12) Fall 2016 (Saslow) White Version

MTV - S1183 Beam Time Summary. Performance test of MTV new detector : CDC. Yumi Totsuka. Department of Physics, Rikkyo University, Tokyo, Japan

Relativistic Dynamics: Testing Relativity and. Determining Properties of the Electron

Chapter 4 Scintillation Detectors

Information about the T9 beam line and experimental facilities

Princeton University, Physics 311/312 Beta Decay, Page 1 BETA DECAY

Assembly and test runs of decay detector for ISGMR study. J. Button, R. Polis, C. Canahui, Krishichayan, Y. -W. Lui, and D. H.

Compton suppression spectrometry

Scintillation Detector

Particles and Waves Final Revision Exam Questions Part 1

Relativistic Electrons

Simulation Studies for a Polarimeter at the International Linear Collider (ILC)

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Neutrino Helicity Measurement

Final Exam, Physics 122-Summer 2003, Fri. 8/22/2003

CfE Higher Physics. Particles and Waves

1 P a g e h t t p s : / / w w w. c i e n o t e s. c o m / Physics (A-level)

Spin-resolved photoelectron spectroscopy

A Brief Introduction to Medical Imaging. Outline

SiPM & Plastic Scintillator

igcse Physics Specification Questions 2. State the equation linking average speed, distance moved and time.

FXA Candidates should be able to :

LAAPD Performance Measurements in Liquid Xenon

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Addendum to the ISOLDE and Neutron Time-of-Flight Committee

13.2 NUCLEAR PHYSICS HW/Study Packet

Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS

Homework 2: Forces on Charged Particles

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

Modern Optical Spectroscopy

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

Trap assisted decay spectroscopy setup at ISOLTRAP

Determination of the boron content in polyethylene samples using the reactor Orphée

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

COMPTON SCATTERING OF GAMMA RAYS

Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

Transcription:

DESIGN OF A WIEN FILTER AND MEASUREMENT OF LONGITUDINAL POLARIZATION OF BETA PARTICLES BY S. S. ABHYANKAR AND M. R. BHIDAY (Department of Physics, University of Poona, Poona-7, India) Received January 18, 1971 (Communicated by Prof. B. V. Thosar, F.A.SC.) ABSTRACT Measurement of longitudinal polarization of beta particles is carried out for a pure beta source Th 204 -- ß --> Pb 204 (2 -#0 unique first forbidden) for v/c = 0.6 using a Wien-filter for transformation of polarization and Mott-scattering for the analysis of transverse polarization. The Wienfilter is most versatile for measurements to study the dependance of polarization with (1) the atomic No. Z, and (2) E the incident energy. The resolution of the Wien-filter arrangement reported here is about 10% with sufficient transmission. The value of polarization is P t (1.09 ± 0.083) vlc which is in agreement with the theoretical value predicted for this transition. INTRODUCTION THE theory of beta decay predicts that the degree of polarization should be proportional to v/c. An accurate knowledge of the energy dependance in continuation with the spectrum shape allows the relative magnitude of several matrix elements to be fixed. The values of these matrix elements are expected to show the effects of a possible violation of time reversal invariance in beta decay. Deviations from full polarization have been reported by several authors. 1-4 Sosnowski et al.5 have also reported such deviations of polarization with Z value of the source. Since definite information on the Z dependance of polarization was lacking it was thought necessary to study this aspect of helicity in greater detail. This paper describes mainly the design and performance of the Wien-filter constructed for this study. Al 53

S 4 S. S. ABHYANKAR AND M. R. BHIDAY EXPERIMENTAL For the measurement of longitudinal polarization of beta particles Mott-scattering method has been used. This method of measurement requires a transformation of polarization of beta particles, from longitudinal to the transverse form. Out of the several available methods for polarization transformation Wien-filter arrangement has been selected. Such a system was found to be the most advantageous because (a) it also acts as a velocity selector, (b) any degree of transformation of polarization for different energies is possible, (c) such a system is axially symmetric and (d) the instrumental asymmetry effects as well as the efficiency of the counters can be tested by suitable reversal of either the electric field E or the magnetic field B. A Wien-filter consists of a crossed electric and magnetic field arrangement (Fig. 1). A beta particle with velocity v travels undeflected through the crossed electric and magnetic fields if JEJv = ß jbj c (1) FiG. 1. Schematic diagram of the experimental set up. whereas, the polarization vector is turned through an angles eg BL 2mcvy 6 (2) where L is the length of the cross-field and g is the gyro magnetic ratio (for electrons g = 2). Hence such a system acts as a polarization transformer besides being a velocity selector. The required values of B (magnetic field) for various selected ß-values and for different degrees of transformation of polarization 4 Q rh) are shown in Table I.

Measurement of Longitudinal Polarization of Beta Particles 55 TABLE I A 0 ß= (v/c) Corresponding B in Gauss E in K.E. of kv/cm electrons (KeV) ir/2=90 0.5 79 56 8.4 Full transformation 0.6 127 78 14.4 0-7 204 115 24.1 0.8 340 186 44.6 0.9 661 398 107-46 A0_vr/3=60 0-5 79 37 5.5 0-6 127 52 9-36 0-7 204 76 16.0 0-8 340 124 29 8 0.9 661 266 72.0 In the present design of the Wien-filter, the length L of the crossed field region was limited to 32 cm, as determined by the size of the magnetic field. The necessary magnetic field was obtained in between the pole-pieces (diameter 32 cm) of a ß-ray spectrometer. The field can be varied uniformly and is stable to within 1%. However, the field structure was not uniform over the full diameter, and showed a slight gradient near the circumference. To counteract the fringing field of the magnet, the plates of the electric condenser were tapered at the ends, producing the same gradient in the electric field as that of the fringing magnetic field. High voltages upto 30 K.V. derived from a Cockroft-Walton voltage doubler circuit could be applied to the plates and measured to an accuracy of 1% by a 300 M Q resistance voltmeter. The magnetic field of the order of 100 gauss could be maintained constant and measured to an accuracy of about 1%. This measurement was standardised with 624 KeV conversion electrons from C+S137

56 S. S. ABHYANKAR AND M. R. BHIDAY The Wien-filter was coupled to the scattering chamber through a second collimating slit. The electrons scattered at 90 0 by the gold foils were detected by two plastic scintillator counters placed symmetrically about the beam axis. The two detectors consisted of identical NE102A plastic scintillators of 5 cm. diameter and of 4 mm. thickness wrapped in aluminium foil (0.00025") and optically coupled to E M I 9714 photomultipliers. 0,000 1 18004 16.00 4 RO% 1200, BOO 244 4'I _ CENT/H6TR6-^ FiG. 2. Horizontal beam profile. The foil was fixed in a perspex foil holder inserted from the top of the scattering chamber. The foil could be rotated about a vertical axis and also could be raised or lowered without breaking the vacuum. The whole of the scattering chamber containing the scintillation counters and the foil could be rotated about the beam axis so that the L-R asymmetry could be detected in any azimuthal plane. Therefore, this arrangement affords a direct measurement of instrumental or geometrical asymmetry,

Measurement of Longitudinal Polarization of Beta Particles 57 The beta-ray sources Th 204 and Cs 137, prepared on thin mylar by evaporation over a spot of diameter 1 cm had a thickness of 3 mg/sq. cm. PERFORMANCE The selected beam was studied for its horizontal spread by a scanning arrangement, which consists of a rectangular scintillator coupled to a photomultiplier, which could be moved transversely to the beam in steps of 1 mm A typical horizontal scan is shown in Fig. 2 which indicates that the beam was symmetrical about the axis and of nearly 2 cm width. Resolution of the system was studied by scanning the Cs137 conversion speak. Figure 3 gives the pulse height spectrum of the conversion electrons. The resolution is about 10% which is quite comparable with that reported by the previous workers.' 2, 5, 7 _ 30 34 38 42 46 CHANNEL NUMBER. FIG. 3. Pulse height spectrum of Cs 337 Figures 4 and 5 show the complete spectra of Th 204 and Cs 137 as seen by this instrument. The linearity of the system was tested as follows. The position of Cs 137 conversion peak was obtained by varying the electric field E for a fixed value of the magnetic field B. The magnetic field was then

58 S. S. ABHYANKAR AND M. R. BHIDAY 24 48 96 120 144 168 FiG. 4. Beta ray spectrum of Cs 1 12 3.6 6.0 84-0.8 13.2 FiG 5. Beta spectrum of TI 204 by wicn-filter.

Measurement of Longitudinal Polarization of.eta Particles 5 altered by a suitable step and the corresponding position of the conversion peak was again determined. The ratio of the two field values in both the cases was found to be the same within the experimental error as shown in Fig. 6. Before proceeding to carry out the left-right scattering asymmetry measurements, the two detecting systems were made identical in t heir performance within 0.8 volts.!lgcrponsj 24 48 72 96 ^20 144 FIG. 6. 624 Key conversion-line spectrum for two values of magnetic field showing the linearity of wien filter. The pulse height spectrum of Th 204 for the selected energy 128 KeV (ß v/c = 0.6) was obtained for incident and scattered electrons. The scattered pulse height peak was found to be displaced by about 2 volts towards the low energy channel. The two detectors were then provided with the appropriate bias to exclude the possibility of recording inelastically scattered electrons (Moller e-e scattering). RESULTS AND DDISCUSSION The value of longitudinal polarization PI is calculated from the relations Pl = (v/c) S (B) ; and L^ = IL -^- Ix where p is the observed asymmetry and S (0) is the asymmetry function.

60 S. S. ABHYANKAR AND M. R. BHIDAY The left-right scattered intensities were recorded in 90 0-270 position 0 over a long interval of time to provide a good statistics. A number of runs were taken with two thin gold foils. The foils were prepared by vacuum deposition of 99.9% pure gold at N.C.L., Poona. The foils were kept inclined at 60 to the beam axis to minimise multiple and plural scattering. 0 The reflection, transmission effects and instrumental asymmetry effects (0-180 ) were ascertained. 0 The left-right scattered intensities were studied over different aximuthal planes and the maximum asymmetry plane (90 0-270 0 ) was found out. The observed IL-IR intensities were corrected for instrumental asymmetry effects and for background. Several scattering runs were taken and a typical one is reported in Table 1I. The observed values of asymmetry A = 0.18 (from Table II) TABLE II L-R Asymmetry measurements for Th 204 electrons of v/c = 0.6 for transition Th 204. ß Pb204 --* (2 p- 0) (unique first forbidden) E = 14.4 Key/cm B = 76 oersteds Source thickness T = 3 mg/sq. cm. ist Foil t = 0.5 mg/sq. cm. 0 180 900 270 Ik-Counts 1.-Counts I,; Counts Is-Counts 1900 1825 2800 1900 Reflection 2820 1850 Transmission 2810 1875 Mean (After subtracting the geometrical asymmetry) D= I= IR =0.18% L IR II Foil t = 1 mg/sq. cm. 0 180 90 270 I, -Counts IR Counts In-Counts IR Counts 1850 1925 1800 2750 Reflection 1900 2850 Transmission 1850 2800 Mean (After subtracting the geometrical asymmetry) Í=0.5% 18 p= Í R L R

Measurement of Longitudinal Polarization of $eta Particles 61 The value of S (0) for gold for ß = 0.6 and for scattering angle 90 0 from data provided by Nelson and Pidds 9 which also takes screening into consideration is S(0) = 0.27 ± 0.008. The calculated values of the longitudinal polarization Pl for Th 204 -* ß - Pó 204 (2._0, unique first forbidden) is Pl = (1 9 + 0.083)v/c, which is in close agreement with theoretical value predicted for this transition. The whole system, made of 'Alkathene' and plexiglass which is advantageous as being of low Z, reduces the back-scattering from the walls. The source used was a pure beta source; hence the gamma background effects and secondary electron effects were negligible. The thickness of the source and the scattering foils were small enough to limit the errors due to multiple and plural scattering within experimental limits. The accuracy of these measurements can be further improved by increasing signal to noise ratio and one can then carry out such measurements under identical conditions for a greater number of pure ß emitting isotopes of widely varying values of Z and for different energies in greater detail. REFERENCES 1. Spivak,, P. E., Nuclear Phys., 1961, 23, 169. Mikaelyan, L. A. et al.; 2. Avakyan, R. O., Soviet Phy. JETP, 1962, 14, 491. Pushkin, V. E., et al. 3. Ladage, A. 4. Kulkarni, V. G. Panat, C. V. and Thosar, B. V. 5. Sosnowski, R. and Wilhelmi, Z. 6. Bargman, V. Michel, L. and Telegdi, V. L. 7. Cavanag, P. E., Turner, J. F. et al. 8. Tolhoek, H. A. and De Groot, R. S. 9. Nelson, D. F. and Pidd, R. W... Dissertation, University of Hamburg, 1961. Phys. Letters, 1963, 7, 52. Nuclear Phys., 1961, 26, 280. Phys. Rev. Letter, 1959, 2, 435. Phil. Mag., 1957, 2 (8), 1105. Physica, 1951, 17, 17; Rev. Modern Phy., 1956, 28, 277. Phys. Rev., 1959, 114, 728.