Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7

Similar documents
DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Measurement of sound absorption coefficient for Fraster felt SpaceCover

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Measurement of Acoustic Properties of light weight concrete SL-Deck

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Testing Procedure: AS ISO

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

REPORT N CR

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

A L I O N Technical Center. Test Report

Paseo Recoletos, nº Madrid TEST REPORT

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Report. Laboratory for Acoustics

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Curtain fabric type Ace Manufacturer Kvadrat A/S

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Fabric REFLECTACOUSTIC

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Renolit stretch ceilings

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Report. Laboratory for Acoustics

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

ISO INTERNATIONAL STANDARD

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Roller blind fabric PRIMACOUSTIC R

RIVERBANK ACOUSTICAL LABORATORIES

Consultancy Report Ref: 9383-R01

TFI Report Sound Absorption Impact Sound Insulation

Calcul des coefficients d'absorption alpha sabine

Air distribution systems. Adjustable induction outlet IN-V...

RIVERBANK ACOUSTICAL LABORATORIES

Report. Draft. Laboratory for Acoustics

ISO INTERNATIONAL STANDARD

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

Laboratory for Acoustics

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

CIRCO. Sound-attenuating transfer unit QUICK FACTS

Development of a small-scale reverberation room

ISO 3741 INTERNATIONAL STANDARD

EFFECT OF MEMBRANE SURFACE TENSION AND BACKED-AIR GAP DISTANCE ON SOUND ABSORPTION CHARACTERISTICS

1 Client The request to draft this report was made by DELTA Light & Optics, Venlighedsvej 4, DK-2970 Hørsholm, Denmark.

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

DIFFUSIVITY AND ITS SIGNIFICANCE TO EFFECTIVE SEAT ABSORPTION IN CONCERT HALLS

Method of estimating the reverberant sound absorption coefficient of the absorbing structure composed of different plane porous materials

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

Room acoustic modelling techniques: A comparison of a scale model and a computer model for a new opera theatre

Evaluation of standards for transmission loss tests

ESTIMATION OF SOUND ABSORPTION COEFFICIENTS OF POROUS MATERIALS. Marianna Mirowska, Kazimierz CzyŜewski

TFI Report Sound Absorption Impact Sound Insulation

Laboratory for Acoustics

45º CONGRESO ESPAÑOL DE ACÚSTICA 8º CONGRESO IBÉRICO DE ACÚSTICA EUROPEAN SYMPOSIUM ON SMART CITIES AND ENVIRONMENTAL ACOUSTICS

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Holistic Acoustic Absorber Design: from modelling and simulation to laboratory testing and practical realization. Toulson, R. and Cirstea, S.

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room

Random incidence transmission loss of a metamaterial barrier system

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

Micro-perforated sound absorbers in stretched materials

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box

GTH. Rectangular double deflection grille QUICK FACTS

The frequency and angular dependence of the absorption coefficient of common types of living plants

ISO INTERNATIONAL STANDARD

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Technical Brief 003 Report on the Measurement of Sound Absorption of Planex Linea Storage Units

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Transcription:

Technical Note Measurement of Sound Absorption for Flex AqTube Performed for Flex Project no.: T202611 Page 1 of 7 19 December 2012 Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72 19 40 01 www.delta.dk VAT No. 12275110

Page 2 of 7 Title Measurement of Sound Absorption for Flex AqTube Journal no. Project no. Our ref. T202611 DH/HSO/ilk Client Flex Diplomvej, Building 377 2800 Kgs. Lyngby Denmark Client ref. Niels Werner Adelman-Larsen, 19 December 2012 Dan Hoffmeyer

Page 3 of 7 1. Introduction At the request of Flex laboratory measurements of the sound absorption in a reverberation room were carried out for Flex AqTube in different configurations. This technical note only presents the test specimens and the test results summarily. 2. Description of the Test Objects The AqTube absorber is an inflatable membrane shaped as a tube. The absorber was tested in the following configurations. OFF refers to empty tube. ON refers to air-filled tube: 1. AqTube OFF, double tubes mounted in lines in an array in a frame (3.00 m x 3.60 m x 1.20 m), 3 samples, c-c 1.00 m 2. AqTube ON, double tubes mounted in lines in an array in a frame (3.00 m x 3.33 m x 1.00 m), 3 samples, c-c 1.00 m 3. AqTube ON, double tubes mounted in lines in an array in a frame (3.00 m x 3.33 m x 1.00 m), 4 samples, c-c 0.75 m 4. AqTube ON, double tube mounted as a discrete object, one sample, measured in two different positions The size of AqTube ON, double tube is approx. 0.7 m x 3.2 m x 1.0 m. 3. Test Results The measurements were carried out according to the test method of EN ISO 354:2003, - Measurement of Sound Absorption in a Reverberation Room. The sound absorption was calculated from the reverberation times measured with and without the test object. The measurements with tubes in lines were performed with a frame surrounding the tubes (Type J mounting), and the empty room was measured with the frame present. The results are given as the sound absorption coefficient. The measurements with a tube as a discrete object were performed with two different randomly chosen positions, and the results are given as the mean value of the equivalent sound absorption area per object. The measurements were performed in room 005, Building 355 at the Technical University of Denmark. The test results per one-third octave from 50 Hz to 5000 Hz are shown in tabular form and graphically on the following graph sheets. Additionally the calculated values per octave from 63 Hz to 4000 Hz are shown.

Page 4 of 7 Frequency alfa s alfa p Hz 50-0.04 63 0.01 0.00 80-0.03 100-0.03 125 0.02 0.00 160 0.02 200 0.00 250-0.01 0.00 315 0.02 400 0.01 500 0.03 0.00 630 0.02 800 0.02 1000 0.03 0.05 1250 0.03 1600 0.04 2000 0.02 0.05 2500 0.06 3150 0.08 4000 0.08 0.10 5000 0.10 1.20 1.00 0.80 0.60 0.40 0.20 1. AqTube OFF, 3 samples in lines in an array in a frame 0.00 Date of test 27-04-2012 Measurement 1 Sound absorption coefficient for AqTube OFF, double tubes mounted in lines in an array in a frame (3.00 m x 3.60 m x 1.20 m), 3 samples, c-c 1.00 m.

Page 5 of 7 Frequency alfa s alfa p Hz 50 0.26 63 0.31 0.30 80 0.37 100 0.35 125 0.28 0.35 160 0.42 200 0.33 250 0.34 0.35 315 0.44 400 0.54 500 0.56 0.55 630 0.52 800 0.45 1000 0.38 0.40 1250 0.33 1600 0.25 2000 0.17 0.20 2500 0.16 3150 0.14 4000 0.13 0.15 5000 0.11 1.20 1.00 0.80 0.60 0.40 0.20 2. AqTube ON, 3 samples in lines in an array in a frame 0.00 Date of test 27-04-2012 Measurement 2 Sound absorption coefficient for AqTube ON, double tubes mounted in lines in an array in a frame (3.00 m x 3.33 m x 1.00 m), 3 samples, c-c 1.00 m.

Page 6 of 7 Frequency alfa s alfa p Hz 50 0.41 63 0.41 0.40 80 0.43 100 0.44 125 0.43 0.45 160 0.52 200 0.44 250 0.43 0.50 315 0.60 400 0.64 500 0.61 0.60 630 0.62 800 0.54 1000 0.45 0.45 1250 0.39 1600 0.30 2000 0.24 0.25 2500 0.20 3150 0.17 4000 0.15 0.15 5000 0.13 1.20 1.00 0.80 0.60 0.40 0.20 3. AqTube ON, 4 samples in lines in an array in a frame 0.00 Date of test 27-04-2012 Measurement 3 Sound absorption coefficient for AqTube ON, double tubes mounted in lines in an array in a frame (3.00 m x 3.33 m x 1.00 m), 4 samples, c-c 0.75 m.

Page 7 of 7 Frequency A A Hz m2 m2 50 0.04 63 0.43 0.40 80 0.67 100 2.09 125 2.05 2.10 160 2.17 200 2.40 250 1.97 2.25 315 2.43 400 2.55 500 2.62 2.55 630 2.48 800 1.92 1000 1.73 1.65 1250 1.34 1600 0.97 2000 0.70 0.80 2500 0.74 3150 0.55 4000 0.53 0.55 5000 0.63 4. AqTube ON, one sample as a discrete object Equivalent sound absorption area per object [m 2 ] 6 5 4 3 2 1 0 Date of test 20-11-2012 Measurement 4 Equivalent sound absorption area per object for AqTube ON, double tube mounted as a discrete object, one sample, measured in two different positions.