Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

Similar documents
RESIDUAL DISPLACEMENT PREDICTION OF R/C BUILDING STRUCTURES USING EARTHQUAKE RESPONSE SPECTRA

OUTLINE OF DAMAGE SURVEYS Surveyed areas Damage surveys were made in Tohoku area (from Hachinohe city in Aomori Prefecture to Soma city in Fukushima P

Field Investigation and Dynamic Analysis of Damaged Structure on Pile Foundation during the 2011 off the Pacific Coast of Tohoku Earthquake

Tsunami Load Evaluation Based on Field Investigations of the 2011 Great East Japan Earthquake

TSUNAMI LOAD EVALUATION BASED ON DAMAGE OBSERVATION AFTER THE 2011 GREAT EAST JAPAN EARTHQUAKE

Estimation Method of Seismic Response Based on Momentary Input Energy Considering Hysteresis Shapes of a Building Structure

Title. Author(s)T. MIZUTANI; Y. NARAZAKI; Y. FUJINO. Issue Date Doc URL. Type. Note. File Information

EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE

STUDY ON DRIFT BEHAVIOR OF CONTAINER ON APRON DUE TO TSUNAMI-INDUCED INCOMING AND RETURN FLOW

APPLICATON OF SEAMLESS SIMULATION OF SEISMIC RESPONSE ANALYSIS AND HIGH RESOLUTION TSUNAMI SIMULATION TO COASTAL AREA OF SENDAI

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS

FAILURE MECHANISM OF CONCRETE SABO DAM BY ROCK IMPACT

REPORT ON THE TOHOKU AREA PASIFIC OFFSHORE EARTHQUAKE


A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

Blank line 10 pt Keywords: Response Characteristics, Skyscraper, Tohoku-Oki earthquake, Natural operiod

Prevention Tsunami wall 10m high (breached by the tsunami due to land level falling by 3m)

Safety Margin Ratio-Based Design of Isolation Gap Size for Base-isolated Structures

ANALYSIS OF EVACUATION BEHAVIORS IN DIFFERENT AREAS BEFORE AND AFTER THE GREAT EAST JAPAN EARTHQUAKE

Forces in Earth s Crust

THE 2011 TOHOKU EARTHQUAKE IN JAPAN. VSU Lyuben Karavelov, Sofia, Bulgaria. Key words: Tohoku earthquake, strong ground motion, damage

RESPONSE OF STRUCTURES AGAINST TSUNAMI FORCES UNDER DIFFERENT SOIL CONDITIONS

Evaluation of tsunami force on concrete girder by experiment simulating steady flow

RESIDUAL STORY-DRIFT OF WEAK-BEAM PORTAL FRAME WITH SLIP-TYPE RESTORING FORCE CHARACTERISTICS OF COLUMN-BASE SUBJECTED TO GROUND MOTION

SEISMIC PERFORMANCE EVALUATION METHOD FOR A BUILDING WITH CENTER CORE REINFORCED CONCRETE WALLS AND EXTERIOR STEEL FLAME

KNOWLEDGE NOTE 5-1. Risk Assessment and Hazard Mapping. CLUSTER 5: Hazard and Risk Information and Decision Making. Public Disclosure Authorized

The impact of the 2011 off the Pacific coast of Tohoku Earthquake on Tsukuba 32-m station

New Tsunami Disaster Mitigation System considering Local Conditions of Indian Ocean Rim Regions

Development of Spherical Sliding Bearing

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

Piles for RC/Steel-frame buildings pulled up by tsunami at Onagawa Town, in the March 11 th 2011 East Japan Earthquake

Tsukuba, Japan International Institute of Seismology and Earthquake Engineering Building Research Institute STUDY TRIP TO ITAKO CITY

Special edition paper

Tsunami Waveform Inversion based on Oceanographic Radar Data

4-3-1 Earthquake and Tsunami Countermeasures of Tokyo s

Preliminary report of the 2011 off the Pacific coast of Tohoku Earthquake *

On The Ultimate Strength of RC Shear Wall under Multi-Axes Seismic Loading Condition

INFLUENCE OF LOADING RATIO ON QUANTIFIED VISIBLE DAMAGES OF R/C STRUCTURAL MEMBERS

Seismic Resistance Capacity of High-Rise Buildings subjected to Long-Period Ground Motions - E-Defense Shaking Table Test

Displacement ductility demand and strength reduction factors for rocking structures

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Source region of the earthquake

Preliminary Examination in Dynamics

Tsunami Load Determination for On-Shore Structures. Harry Yeh Oregon State University

EFFECT OF SHEAR REINFORCEMENT ON FAILURE MODE OF RC BRIDGE PIERS SUBJECTED TO STRONG EARTHQUAKE MOTIONS

Overflow Pattern and the Formation of Scoured Region by the Tsunami Propagated in River Channels in Great East Japan Earthquake

Risk-based land use and spatial planning

Earthquake Hazards. Tsunami

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

Simulation of Nonlinear Behavior of Wall-Frame Structure during Earthquakes

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

2.3 Notes: Earthquake Damage Can Be Reduced

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

Outline of Guideline for Development and Utilization of Tsunami Disaster Management Map

[Hussain, 4(9): September 2017] ISSN DOI /zenodo Impact Factor

CAPACITY SPECTRUM FOR STRUCTURES ASYMMETRIC IN PLAN

NUMERICAL SIMULATION OF HYDROGEN EXPLOSION TESTS WITH A BARRIER WALL FOR BLAST MITIGATION

Case Study On The Soft-First-Story Buildings Strengthened By Confined Concrete Columns

NUMERICAL ANALYSIS OF DAMAGE OF RIVER EMBANKMENT ON SOFT SOIL DEPOSIT DUE TO EARTHQUAKES WITH LONG DURATION TIME

Case study of Japan: Reference Frames in Practice

NONLINEAR SEISMIC SOIL-STRUCTURE (SSI) ANALYSIS USING AN EFFICIENT COMPLEX FREQUENCY APPROACH

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

COASTAL ENGINEERING 2016 A PREDICTIVE MODEL FOR SCOUR DEPTH OF COASTAL BUILDING FAILURES DUE TO TSUNAMIS

EDEM DISCRETIZATION (Phase II) Normal Direction Structure Idealization Tangential Direction Pore spring Contact spring SPRING TYPES Inner edge Inner d

The 2011 Tohoku Earthquake and Tsunami Sequence. Mitchell May, EPSC 330

Application of Capacity Spectrum Method to timber houses considering shear deformation of horizontal frames

VERIFICATION TEST AND EARTHQUAKE RESPONSE OBSERVATION OF A BASE ISOLATED BUILDING WITH ECCENTRIC ROLLER BEARINGS

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

INFLUENCE OF TSUNAMI INDUCED SCOURING ACTION ON FOUNDATION STABILITY OF COASTAL STRUCTURES

Nonlinear numerical simulation of RC frame-shear wall system

Earthquake Hazards. Tsunami

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

Tohoku Earthquake and Tsunami Japan March 11, 2011 Information updated 4/19/2011

Tsunami Hydrodynamic Force on Various Bridge Sections

Dynamic Stability and Design of Cantilever Bridge Columns

R.SUNDARAVADIVELU Professor IIT Madras,Chennai - 36.

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

Earthquakes. Chapter Test A. Multiple Choice. Write the letter of the correct answer on the line at the left.

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Impact-resistant behavior of shear-failure-type RC beams under falling-weight impact loading

Earthquake Hazards. Tsunami

Available online at ScienceDirect. Procedia Engineering 116 (2015 )

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

IG-WRDRR, UNESCAP, UNESCO-IOC, WMO. Yukio Tamura Chairman, International. Group. Tuesday 10 May, , Room 13. for Disaster. Risk.

Structures Group Report

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

Earthquakes and Tsunamis

UGRC 144 Science and Technology in Our Lives/Geohazards

Basic Analysis on Building Damages by Tsunami due to The 2011 Great East Japan Earthquake Disaster Using GIS

Chord rotation demand for Effective Catenary Action under Monotonic. Loadings


Dynamic Analysis Using Response Spectrum Seismic Loading

SMR/ May Simulation Analyses of Tsunami caused by Chilean and Nihon-Kai Chubu Earthquakes at Nuclear Power Plant Sites in Japan

Damage of Sewage Plant by Tsunami

UNDERSTANDING TSUNAMI RISK TO STRUCTURES: A CANADIAN PERSPECTIVE

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

at IHO IRCC7 Mexico City, Mexico, June 2015

Ömer AYDAN. Ismail FEBRIN. Fumihiko IMAMURA KOGAMI (Tsunami Alert Community-NPO)

PEER/SSC Tall Building Design. Case study #2

Lecture 4 Dynamic Analysis of Buildings

Transcription:

Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects Ho CHOI 1, Kazuto MATSUKAWA 2 and Yoshiaki NAKANO 3 1 Research Associate, Institute of Industrial Science, The University of Tokyo, Japan choiho@iis.u-tokyo.ac.jp 2 Research Associate, Institute of Industrial Science, The University of Tokyo, Japan 3 Professor, Institute of Industrial Science, The University of Tokyo, Japan ABSTRACT After the 2011 Great East Japan Earthquake, the quantitative evaluation method of tsunami load and the design guideline for tsunami evacuation buildings were established in Japan. However, the impulsive force of drifting objects such as vessels and containers etc. due to tsunami is not taken into consideration in the guideline. Therefore, it is necessary to establish the quantitative evaluation method of the impulsive force and to investigate whether the force should be taken into account to the current design guideline for tsunami evacuation buildings. In this paper, the response characteristics of R/C buildings considering the impulsive force of tsunami drifting objects are analytically and experimentally investigated. For this purpose, nonlinear analyses are conducted to evaluate the dynamic response of a six story R/C tsunami evacuation building, and collision experiments using 1/100 scale specimens are carried out to verify the validity of analytical results. Keywords: the 2011 Great East Japan Earthquake, tsunami evacuation building, impulsive force, drifting object, response characteristics 1. INTRODUCTION The 2011 Great East Japan Earthquake that occurred at 14:46 local time on March 11, 2011, had magnitude of 9.0 on the Richter Scale with the epicenter approximately 70 km east of the Oshika Peninsula in Miyagi Prefecture (38.322 N, 142.369 E, Depth: 32km). This earthquake triggered terrible tsunami waves which hit the coast of Japan and propagated around the Pacific Ocean, and this tsunami caused extensive and severe building damage such as pancake collapse, overturning, movement, tilting, sliding, and debris collision. Authors conducted tsunami damage investigations in Tohoku area (from Hachinohe city in Aomori Prefecture to Soma city in Fukushima Prefecture) from the beginning of April through the end of June, 2011.

0ctober 2013, Hanoi, Vietnam After the 2011 Great East Japan Earthquake, the quantitative evaluation method of tsunami load and the design guideline for tsunami evacuation buildings were established in Japan. However, the impulsive force of drifting objects such as vessels and containers etc. due to tsunami as shown in Photo 1 is not taken into consideration in the guideline. Therefore, it is necessary to establish the quantitative evaluation method of the impulsive force and to investigate whether the force should be taken into account to the current design guideline for tsunami evacuation buildings. In this paper, the response characteristics of R/C buildings considering the impulsive force of tsunami drifting objects are analytically and experimentally investigated. For this purpose, nonlinear analyses are conducted to evaluate the dynamic response of a six story R/C tsunami evacuation building, and collision experiments using 1/100 scale specimens are carried out to verify the validity of analytical results. (a) Collapsed building due to collision (b) Large vessel drifted by tsunami Photo 1: Building damage due to collision of tsunami drifting object 2. BUILDING RESPONSE EVALUATION BY NONLINEAR ANALYSIS 2.1 Reference building and modeling for nonlinear response analysis In this study, a six story apartment R/C building, which is a tsunami evacuation building designed as tsunami inundation depth h=10m and water depth coefficient a=2.0 (NILIM, 2012) as shown in Figure 1, is selected to analytically evaluate the response characteristics due to both of the tsunami load and the impulsive force of a tsunami drifting object. The assumptions on nonlinear response analyses are as follows. (1) The reference building is replaced as six degree of freedom model with single degree of freedom per one story as shown in Figure 2. (2) The base shear coefficient C of this building is 1.15. New Technologies for Urban Safety of Mega Cities in Asia

(3) The hysteretic characteristic of each story is employed Takeda model (Takeda, T. et al., 1970) having yielding drift angle of 1/200 rad. and stiffness degradation factor of 0.4 after yielding point. (4) The well-known Newmark method is employed for numerical integration. (5) The predominant period of this building is set as 0.26 second, and the weight per unit floor area is assumed as 14 N/mm 2. 13,500 (a) Floor plan of first floor (b) Elevation of sea side Figure 1: Reference building 2.2 Estimation of tsunami load and impulsive force As shown in Figure 2, overall tsunami load acting on the reference building is assumed a triangular shape with the height reaching the water depth coefficient a times of the design tsunami inundation depth h based on the Japanese guideline (NILIM, 2012), and the tsunami load acting on each floor is calculated by halves of story height of up-and-down story. The debris collision force shown in Figure 2 is calculated by Mizutani equation shown in equation (1) (Mizutani, N. et al., 2007), and then the impulsive force can be computed by the product of the collision force F m and the collision time d t. F m WV 2 x 2 BcVx (1) gdt a 2F r (2) F r V gh (3) Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

0ctober 2013, Hanoi, Vietnam where, F m : Debris collision force (kn) : Mass per unit volume of water (1.0 t/m 3 ) : Tsunami run-up height (m, assumed as tsunami inundation height h (=9m) herein) B c : Width of tsunami drifting object (m) V x : Collision velocity (6.6 m/s, assumed as a half of tsunami flow velocity V (13.2 m/s) mentioned later) W : Weight of tsunami drifting object (kn) g : Gravity acceleration (9.8 m/s 2 ) d t : Collision time (s, assumed 10ms to 50ms (Mizutani, N. et al., 2007)) a : Water depth coefficient (=2.0 herein) F r : Froude number V : Tsunami flow velocity (13.2 m/s, calculated by equation (2) and (3)) Figure 2: Schematic illustrations of tsunami load and impulsive force 2.3 Analysis parameters Table 1 shows the parameters of this analysis. As shown in the Table, main parameter of Case 1 is the debris mass, and that of Case 2 is the collision time, respectively. Table 1: Parameters of this analysis Debris mass (t) Collision time (s) Collision velocity (m/s) 100 Case 1 200 300 400 30 6.6 10 Case 2 200 30 6.6 50 New Technologies for Urban Safety of Mega Cities in Asia

2.4 Analysis results 2.4.1 Results of Case 1 Figure 3 shows the distribution of the ductility factor of each story according to increasing the mass of tsunami drifting objects. When only tsunami load is considered, the ductility factors of all stories are less than 1.0 of ductility factor. However, as the debris mass increases, the ductility factors of each story also increase, and yielding point is exceeded in more than 200t of the debris mass. This result means that it is occasionally necessary to take into account the influence of the collision of tsunami drifting objects at the time of the structural design of a tsunami evacuation building. Story 6 Only tsunami load 5 Debris mass (100t) Debris mass (200t) 4 Debris mass (300t) Debris mass (400t) 3 Collision point 2 Cracking 1 point Yielding point 0 0.0 0.5 1.0 1.5 2.0 2.5 Ductility factor Figure 3: Ductility factor of each story according to increasing of debris mass 2.4.2 Results of Case 2 Figure 4 shows the distribution of the ductility factor of each story in accordance with changing the collision time. As shown in the figure, even if the collision time is changed, maximum ductility factors are almost the same. This result is caused by equation (1) employed in this analysis. Since the equation governs the second term, it can be briefly rewritten as equation (4). If the products of the debris mass m and the collision velocity V x (i.e., the momentum) are the same as this case, the Story 6 5 4 3 Only tsunami load Collision time (10ms) Collision time (30ms) Collision time (50ms) Collision point 2 Cracking 1 point Yielding point 0 0.0 0.5 1.0 1.5 Ductility factor Figure 4: Ductility factor of each story according to changing collision time Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

0ctober 2013, Hanoi, Vietnam collision time d t and the collision force F m serve as reciprocal relations as shown in equation (4). Therefore, the impulsive forces calculated by the product of the collision force and the collision time become the same, and eventually maximum ductility factors also become the same. F d mv (4) m t x 3. COLLISION EXPERIMENT USING SCALED MODEL 3.1 Outline of experiment and measurement system In this study, 1/100-scale specimens which are model building designed by the reference building shown in Figure 1 and model tsunami drifting objects supposing vessels of 100 to 300 ton class are fabricated, and the collision tests are carried out to investigate the collision force and the collision time between model building and model tsunami drifting object. Figure 5 shows the schematic illustration of this experiment system. As shown in the figure, the model building fixed to linear slider run onto the model tsunami drifting object in this test. Figure 5: Schematic illustration of this experiment system The maximum collision force F m and the collision time d t are calculated from the wave pattern obtained by the load cell installed the model building as shown in Figure 5. The relative lateral displacement of the model building is measured by the laser displacement sensor. 3.2 Experiment parameters Table 2 shows the parameters of this experiment. As shown in the Table, main parameter of Case 1 is the debris mass, and that of Case 2 is the same momentum which is calculated by the product of the collision velocity and the debris mass, respectively. New Technologies for Urban Safety of Mega Cities in Asia

Table 2: Experiment parameters Collision velocity(mm/s) Debris mass (g) Plate thickness (mm) 100 Case 1 200 200 300 0.5 300 100 Case 2 150 200 0.5 100 300 3.3 Experiment results 3.3.1 Results of Case 1 Figures 6(a) and 6(b) show the relationships between the collision force and the collision time, and the maximum collision displacement and the impulse force due to different mass of tsunami drifting object, respectively. As can be found in Collision force (N) 50 40 30 20 10 0 [Case 1] [Mass of tsunami drifting object] 100g 200g 300g 0.995 1.000 1.005 1.010 Time (sec.) (a) Relation of collision force and collision time due to mass of drifting object Max. collision displacement (mm) 0.05 0.04 0.03 0.02 [Case 1] 0.01 [Mass of tsunami drifting object] 100g 200g 300g 0.00 0.00 0.05 0.10 0.15 Impulsive force (N*s) (b) Relation of collision displacement and impulsive force due to mass of drifting object Figure 6: Results of Case 1 Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

0ctober 2013, Hanoi, Vietnam Figure 6(a), both of the collision force and the collision time quantitatively increase as the debris mass increases. Furthermore, the maximum collision displacement and impulsive force increase linearly together with increasing debris masses as shown in figure 6(b). 3.3.2 Results of Case 2 Figures 7(a) and 7(b) show the relations of the collision force and the collision time, and the maximum collision displacement and the impulsive force under same momentum, respectively. As the debris mass increases and the collision velocity decreases, the collision time increases and the collision force decreases as shown in Figure 7(a). However, the impulsive force and the collision displacement are almost the same under same momentum as shown in Figure 7(b). Collision force (N) 40 30 20 10 0 [Case 2] [Same momentum] 100g 300mm/s 200g 150mm/s 300g 100mm/s 0.995 1.000 1.005 1.010 Time (sec.) (a) Relation of collision force and collision time under same momentum Max. collision displacement (mm) 0.05 0.04 0.03 [Case 2] 0.02 [Same momentum] 0.01 100g 300mm/s 200g 150mm/s 300g 100mm/s 0.00 0.00 0.05 0.10 0.15 Impulsive force (N*s) (b) Relation of collision displacement and impulsive force under same momentum Figure 7: Results of Case 2 3.3.3 Relationship between impulsive force and momentum In this section, the relationship between the momentum of the model tsunami drifting object and the impulsive force imposed the model building is investigated. New Technologies for Urban Safety of Mega Cities in Asia

As shown in Figure 8, the impulsive forces calculated by the product of the collision force F m and the collision time d t shown in equation (4) are about 2 times of the momentums obtained by the product of the debris mass m and the collision velocity V x. This result is different from the analysis result that the impulsive force is almost equal to the momentum as shown in equation (4) and Figure 4 in section 2.4.2. This can be explained from equation (7) obtained by equations (5) and (6) based on the law of conservation of momentum and the law of conservation of energy, respectively. As shown in equation (7), the velocity v x of tsunami drifting object after the collision is 2 times of the velocity V x of building before the collision when the value of is close to zero (M»m), while v x is almost equal to V x when is 1.0 (M=m). In this test, since the mass of the building is quite larger than that of tsunami drifting object, the impulsive force became twice the momentum as mentioned above. Impulsive force by experiment (kg*m/s) 0.14 0.12 0.10 0.08 0.06 0.04 2.0 1.0 0.02 Case1 Case2 0.00 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 Momentum by experiment (kg*m/s) Figure 8: Relation of impulse force and momentum by experiment ' x ' x MVx mvx MV mv (5) 1 2 1 2 1 ' 2 1 ' MV 2 x mvx M Vx m vx (6) 2 2 2 2 ' 2 m v x V x (7) 1 M where, M, m : Mass of building and tsunami drifting object, respectively : Velocity of building and tsunami drifting object before collision, V x, v x respectively (v is zero in this test) V x, v x : Velocity of building and tsunami drifting object after collision, respectively : Ratio of mass of tsunami drifting object to mass of building Response characteristics of R/C buildings considering impulsive force of tsunami drifting objects

0ctober 2013, Hanoi, Vietnam 4. CONCLUSIONS In order to investigate the response characteristics of R/C buildings due to collision force of tsunami drifting objects, nonlinear response analyses and simple collision tests are carried out. The major findings can be summarized as follows. (1) As increasing of the mass of tsunami drifting object, both of the impulsive force and the maximum displacement of the building increased in both of the analyses and the tests. (2) When the amount of the momentum is constant, the impulsive force and the maximum displacement of the building are constant in both of the analyses and the tests. (3) When the mass of the building is quite larger than that of tsunami drifting object, the impulsive force became twice the momentum. In future research, the collision tests for the value of which is the ratio between masses of building and tsunami drifting object will be carried out to establish the design procedure of a tsunami evacuation building considering the collision force. REFERENCES National Institute for Land and Infrastructure Management (NILIM), 2012. Practical Guide on Requirement for Structural Design of Tsunami Evacuation Buildings. Technical note of NILIM, No.673. (in Japanese) Takeda, T., Sozen, A., and Nielsen, N.M., 1970. Reinforced Concrete Response to Simulated Earthquakes. Journal of Structural Division, ASCE, Vol.96:No.ST12, 2557-2573. Yeom, G.S., Muzutani, N., Shiraishi, K., Usami, A., Miyajima, S., and Tomita, T., 2007. Study on Behavior of Drifting Containers due to Tsunami and Collision Forces. Journal of Japan Society of Civil Engineers, Ser.B2 (Costal Engineering), JSCE, Vol.54, 851-855. New Technologies for Urban Safety of Mega Cities in Asia