Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Similar documents
ANALYSIS CERTIFICATE OF

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3165 Lot Number: EDTA NIST SRM 928 Lot Number: 928

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3122 Lot Number:

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3103a Lot Number:

Single Analyte Custom Grade Solution. 999 ± 3 µg/ml g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number:

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number:

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number: Cr3

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Mass Spec Solution ± 0.60 µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ICP/MS Multi-Element Standards

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Certificate of Analysis

Certified Reference Material - Certificate of Analysis

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Background Statement for SEMI Draft Document #5329 NEW STANDARD: GUIDE FOR TRIS(DIMETHYLAMINO) SILANE (3DMAS)

Hiroshi Sawai TKG Laboratory Center International Standardisation Office

Single-Element Standards for AAS

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Rapid Sample Assessment and Simplified Method Development with IntelliQuant

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Examples of Method Validation Studies Conducted in Different Economies

Certified Reference Material - Certificate of Analysis

Certificate of Analysis

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

Analytical Quality Control ensure the safety of the results of your samples

Graphite Furnace Tubes

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

DETERMINATION OF TRACE ELEMENTS IN DRINKING WATER BY AXIALLY VIEWED INDUCTIVELY COUPLED PLASMA - ATOMIC EMISSION SPECTROMETRY. Revision 4.

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Entry Guide for "DIC RAW MATERIAL SURVEY" for Form Version 4.1

Background Statement for SEMI Draft Document 5324 NEW STANDARD: GUIDE FOR CYCLOPENTANONE

Metolachlor ESA Sodium Salt Standard

Gamma and X-Ray Standards

METHOD 6010A INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY

Chapter 2 Atoms and the Periodic Table

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Bulk Silica Gels. SiliaFlash Irregular Silica Gels SiliaSphere PC Spherical Silica Gels

Samples compliant with the WATER

Full file at

In addition to the information at the end of the exam, you will be given a periodic table.

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Note that the protons and neutrons are each almost 2,000 times more massive than an electron; What is the approximate diameter of an atom?

Certificate of analysis Certified reference material code: CRM-00-NEO

Technical Procedure for General Laboratory Equipment

CONTACT INFORMATION EQUIPMENT SAMPLE INFORMATION

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Certificate of Analysis

Writing Chemical formula with polyatomic groups

NPL, India activity related to water as per the need of the country

ICP-OES Application Note Number 35

Method 0060 or Method 29. Method for Determining Metals and Mercury Emissions in Stack Gas

SPECTRASCAN ELEMENTAL STANDARDS FOR ATOMIC SPECTROSCOPY

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

Electron Configurations

Unit 3 Atomic Structure

APPENDIX C TO PART 136 INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC METHOD FOR TRACE ELEMENT ANALYSIS OF WATER AND WASTES METHOD

Certificate of Analysis

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use.

Sodium Chloride - Analytical Standard

Homework Chapter 03 Chemistry 51 Los Angeles Mission College Answer the following questions: a. What electron sublevel starts to fill after

CERTIFIED REFERENCE MATERIAL RRM Au014

Form A. Exam 1, Ch 1-4 September 23, Points

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

8. Relax and do well.

Dear PAP Chemistry Students,

CertiPUR. A class of its own. Merck s ICP Laboratory now with ISO accreditation

Chapter 1 -- Introduction to Qualitative Analysis. NAME: Lab Section: Date: Sign-Off:

Background Statement for SEMI Draft Document 4498A REVISION OF SEMI C , SPECIFICATION FOR ACETONE

Certificate of Analysis

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

The Uncertainty of Reference Standards

Inspection Documents for Type 2.1 Coverage:

The following table of work functions for metals may be helpful for some of the problems in this homework:

Tri-n-propyltin Chloride Mixture

ELEMENTS AND COMPOUNDS

CALIBRATION CERTIFICATE # 503

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

METALS IN WATER BATCH: MATERIAL. Description. Cu, Ni and. Quantity 5% (V/V). Use. the mark in. such a way. water. The are given in QC METAL HL2

Transcription:

1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for the Competence of Testing and Calibration Laboratories". Inorganic Ventures is also an ISO 9001 registered manufacturer (SAI Global File Number 010105). 2.0 PRODUCT DESCRIPTION Testing Laboratory Certificate 883.01 Reference Material Producer Certificate 883.02 Product Code: Catalog Number: Lot Number: Matrix: Value / Analyte(s): Multi Analyte Custom Grade Solution IV-STOCK-50 K2-MEB622036 5% (v/v) HNO3 tr. HF 1 000 µg/ml ea: Calcium, Iron, Potassium, Magnesium, 10 µg/ml ea: Sodium, Silver, Aluminum, Arsenic, Barium, Beryllium, Cadmium, Cobalt, Chromium+3, Copper, Manganese, Molybdenum, Nickel, Lead, Antimony, Selenium, Thorium, Thallium, Uranium, Vanadium, Zinc 3.0 CERTIFIED VALUES AND UNCERTAINTIES Page 1 of 6

ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE Aluminum, Al 10.00 ± 0.06 µg/ml Antimony, Sb 10.00 ± 0.07 µg/ml Arsenic, As 10.00 ± 0.08 µg/ml Barium, Ba 10.00 ± 0.06 µg/ml Beryllium, Be 10.00 ± 0.06 µg/ml Cadmium, Cd 10.00 ± 0.06 µg/ml Calcium, Ca 1 000 ± 4 µg/ml Chromium+3, Cr3 10.00 ± 0.05 µg/ml Cobalt, Co 10.00 ± 0.05 µg/ml Copper, Cu 10.00 ± 0.05 µg/ml Iron, Fe 1 000 ± 4 µg/ml Lead, Pb 10.00 ± 0.05 µg/ml Magnesium, Mg 1 000 ± 4 µg/ml Manganese, Mn 10.00 ± 0.05 µg/ml Molybdenum, Mo 10.00 ± 0.05 µg/ml Nickel, Ni 10.00 ± 0.05 µg/ml Potassium, K 1 000 ± 4 µg/ml Selenium, Se 10.00 ± 0.06 µg/ml Silver, Ag 10.00 ± 0.06 µg/ml Sodium, Na 1 000 ± 4 µg/ml Thallium, Tl 10.00 ± 0.07 µg/ml Thorium, Th 10.00 ± 0.05 µg/ml Uranium, U 10.00 ± 0.05 µg/ml Vanadium, V 10.00 ± 0.05 µg/ml Zinc, Zn 10.00 ± 0.05 µg/ml Certified Density: 1.039 g/ml (measured at 20 ± 1 ºC) Assay Information: Page 2 of 6

ANALYTE Ag Ag Al Al As As Ba Ba Be Be Ca Ca Cd Cd Co Co Cr3 Cr3 Cu Cu Fe Fe K K Mg Mg Mn Mn Mo Na Na Ni Ni Pb Pb Sb Se Se Th Th Tl U U V V Zn Zn METHOD NIST SRM# SRM LOT# ICP Assay 3151 992212 Volhard 999b 999b ICP Assay 3101a 060502 ICP Assay 3103a 100818 ICP Assay 3104a 070222 Gravimetric See Sec. 4.2 ICP Assay 3105a 090514 ICP Assay 3109a 050825 ICP Assay 3108 060531 ICP Assay 3113 ICP Assay 3112a 000630 Co 030730Cr3 ICP Assay 3114 011017 ICP Assay 3126a 140812 ICP Assay 3141a 051220 Gravimetric See Sec. 4.2 ICP Assay 3131a 050302 ICP Assay 3132 050429 ICP Assay 3134 130418 ICP Assay 3152a 120715 Gravimetric See Sec. 4.2 ICP Assay 3136 120619 ICP Assay 3128 101026 ICP Assay 3102A 061229 ICP Assay 3149 100901 ICP Assay Traceable to SRM 3159 992912 ICP Assay 3158 993012 ICP Assay 3164 080521 ICP Assay 3165 992706 ICP Assay 3168a 120629 Page 3 of 6

The following equations are used in the calculation of the certified value and the uncertainty. Reported uncertainties represent expanded uncertainties expressed at approximately the 95% confidence level using a coverage factor of k = 2. Characterization of CRM by two independent methods Characterization of CRM by one method Certified Abundance: IV's Certified Abundance Isotope Atom % Uranium 238U 99.6 ± 0.1 Uranium 235U 0.37 ± 0.05 4.0 TRACEABILITY TO NIST - This product is traceable to NIST via an unbroken chain of comparisons. The uncertainties for each certified value are reported, taking into account the SRM/RM uncertainty error and the measurement, weighing and volume dilution errors. In rare cases where no NIST SRM/RM are available, the term 'in-house std.' is specified. 4.1 Thermometer Calibration - All thermometers are NIST traceable through thermometers that are calibrated by an accredited calibration laboratory. 4.2 Balance Calibration - All analytical balances are calibrated by an accredited calibration laboratory and procedure. The weights used for testing are annually compared to master weights and are traceable to NIST. 4.3 Glassware Calibration 5.0 6.0 7.0 - An in-house procedure is used to calibrate all Class A glassware used in the manufacturing and quality control of CRM/RMs. TRACE METALLIC IMPURITIES (TMI ) DETERMINED BY ICP-MS AND ICP-OES (µg/ml) N/A INTENDED USE - For the calibration of analytical instruments and validation of analytical methods as appropriate. INSTRUCTIONS FOR THE CORRECT USE OF THIS REFERENCE MATERIAL 7.1 Storage and Handling Recommendations - Keep cap tightly sealed when not in use. Store and use at 20 ± 4 C. Do not pipette from the container. Do not return removed aliquots to container. HF Note: This standard should not be prepared or stored in glass. Low Silver Note: This solution contains LOW levels of Silver. Please store this entire bottle inside a sealed glass jar. Uranium Note: If uranium is present in this standard, it is natural abundance unless specified in Section 3.0 Page 4 of 6

8.0 9.0 HAZARDOUS INFORMATION - Please refer to the Safety Data Sheet for information regarding this CRM/RM. HOMOGENEITY - This solution was mixed according to an in-house procedure and is guaranteed to be homogeneous. Homogeneity data indicate that the end user should take a minimum sample size of 0.2 ml to assure homogeneity. 10.0 QUALITY STANDARD DOCUMENTATION 10.1 10CFR50 Appendix B - Nuclear Regulatory Commission - Domestic Licensing of Production and Utilization Facilities 10.2 10CFR21 - Nuclear Regulatory Commission - Reporting defects and Non-Compliance 10.3 ISO 9001 Quality Management System Registration - SAI Global File Number 010105 10.4 ISO/IEC Guide 17025 "General Requirements for the Competence of Testing and Calibration Laboratories" - Chemical Testing - Accredited / A2LA Certificate Number 883.01 10.5 ISO Guide 34 "General Requirements for the Competence of Reference Material Producers" - Reference Material Producer - Accredited / A2LA Certificate Number 883.02 Inorganic Ventures, 300 Technology Drive, Christiansburg, Va. 24073, USA; Telephone: 800.669.6799; 540.585.3030, Fax: 540.585.3012; inorganicventures.com; info@inorganicventures.com 11.0 CERTIFICATION, EXPIRATION AND PERIOD OF VALIDITY 11.1 Certification Issue Date March 04, 2016 11.2 Expiration Date 11.3 Period of Validity - The certification is valid within the measurement uncertainty specified provided the CRM/RM is handled and stored in accordance with instructions given in Sec 7.0 and used prior to the date given in Sec 11.2. This certification is nullified if the CRM/RM is damaged, contaminated, or otherwise modified. Page 5 of 6

12.0 NAMES AND SIGNATURES OF CERTIFYING OFFICERS Certificate Prepared By: James King Jr Product Documentation Supervisor Certificate Approved By: Michael Booth QC Supervisor Certifying Officer: Paul Gaines PhD., Senior Technical Director Page 6 of 6