Density of an Unknown

Similar documents
Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

CHEM 334 Quantitative Analysis Laboratory

Experimental Procedure. Lab 406

College Chem I 2045C Specific Heat of a Metal-SL. Objective: In this lab, you will use calorimetry to determine the specific heat of a metal.

Experiment 8 Introduction to Volumetric Techniques I. Objectives

EXPERIMENT 14 SPECIFIC HEAT OF WATER. q = m s T

Part II. Cu(OH)2(s) CuO(s)

Experiment: Titration

Experiment 20: Analysis of Vinegar. Materials:

Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

Density of Aqueous Sodium Chloride Solutions

Reaction of Magnesium with Hydrochloric Acid

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Read the lab thoroughly. Answer the pre-lab questions that appear at the end of this lab exercise.

Chemistry 212 MOLAR MASS OF A VOLATILE LIQUID USING THE IDEAL GAS LAW

The Synthesis and Analysis of Aspirin

The Molecular Weight of Carbon Dioxide

Experiment 1. Determination of the Density of Water and an Unknown Solid Sample

Experiment 7A ANALYSIS OF BRASS

Chesapeake Campus Chemistry 111 Laboratory

EXPERIMENT 7: THE LIMITING REACTANT

Minneapolis Community and Technical College. Separation of Components of a Mixture

Determination of Orthophosphate Ion

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Chesapeake Campus Chemistry 111 Laboratory

Density of Aqueous Sodium Chloride Solutions

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

EXPERIMENT 9 SALTWATER CONDUCTANCE: The Effect of Concentration

Acid-Base Titration. M M V a

ph Titration Curves You will need about 10 ml of ~6M NaOH solution and about 40 ml of each acid solution and about 1.5 grams of KHP.

PART I: MEASURING MASS

Experiment 20-Acid-Base Titration: Standardization of KOH and Determination of the Molarity and/or Percent Composition of an Acid Solution

HHPS WHMIS. Rules MSDS Hazard Codes Systems. Biology based. Chemistry based. Safety Symbols. Safety in the Lab. Lab Equipment

You must bring 1-2 empty pop cans to lab this week.

The Determination of an Equilibrium Constant

Determination of Orthophosphate Ion

Conductometric Titration & Gravimetric Determination of a Precipitate

Chemistry 143 Dr. Caddell Laboratory Experiment 1

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

Ascorbic Acid Titration of Vitamin C Tablets

Introduction. Objectives

Unit 1. The Math of Chemistry

Chemistry Calibration of a Pipet and Acid Titration

(b) Write the chemical equation for the dissolution of NaOH in water.

NOTE: YOU WILL BE USING THIS SOLUTION IN BOTH, THIS EXPERIMENT AND EXP 12B. IF YOU WASTE THE SOLUTION YOU MAY RUN OUT BEFORE YOU HAVE FINISHED EXP 12B

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Lab Activity 3: Factors Affecting Reaction Rate

Working in the Chemistry Laboratory

TITRATION OF AN ACID WITH A BASE

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

To become acquainted with simple laboratory measurements and calculations using common laboratory equipment.

Chemical Reactions: The Copper Cycle

Determination of the K a Value and Molar Mass of an Unknown Weak Acid

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment #7. Titration of Vinegar

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

Experiment 12 Determination of an Enthalpy of Reaction, Using Hess s Law

TRATION: ANALYSIS OF VINE

In this lab you are asked to make a series of volume and temperature measurements and record the number of significant figures in each measurement.

Using Conductivity to Find an Equivalence Point

In this laboratory exercise we will determine the percentage Acetic Acid (CH 3 CO 2 H) in Vinegar.

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

MS20 Laboratory Seawater Salinity and Density

Preparation of an Ester Acetylsalicylic Acid (Aspirin)

Titration of an Unknown Acid

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

CHM111 Lab Titration of Vinegar Grading Rubric

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide:

Lab Equipment and Safety

Titration of Acetic Acid in Vinegar Minneapolis Community and Technical College v.9.17

MEASUREMENT: PART II

# 12 ph-titration of Strong Acids with Strong Bases

GRIGNARD REACTION Synthesis of Benzoic Acid

Acid-Base Titration. Evaluation copy

Acid-Base Titration. Sample

Chemistry 143 Acid Base Titration Dr. Caddell. Titrating Acid

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

Chemical Reactions of Copper and Percent Recovery

#09 Investigating the Relationship between the Mass of a Liquid and its Volume Ken Lyle, St. John s School, Houston, TX

HYSICAL AND CHEMICAL PROPERTIES AND PHYSIC AND CHEMICAL CHANGES

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

The Thermodynamics of the Solubility of Borax

PURPOSE: 1. To illustrate an oxidation-reduction titration with potassium permanganate 2. To determine the percent mass of iron in an unknown.

EXPERIMENT 6 Empirical Formula of a Compound

EXPERIMENT #9 PRELAB EXERCISES. Redox Titration (Molarity Version) Name Section. 1. Balance the following redox reaction under acidic conditions.

Conductimetric Titration and Gravimetric Determination of a Precipitate

Acid-Base Titrations

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Experiment 8 - Chemical Changes

STOICHIOMETRY AND THE CHEMICAL REACTION

O H 3 O 1 1 A. O 1 1 OH (K w

Lab Activity 3: Gravimetric Stoichiometry 2

Thermodynamics and the Solubility of Sodium Tetraborate Decahydrate

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Periodicity of Properties of Oxides

Transcription:

Experiment 3 Density of an Unknown Pre-Lab Assignment Before coming to lab: Read the lab thoroughly. Answer the pre-lab questions that appear at the end of this lab exercise. Purpose The density of an unknown seed will be determined using the displacement of water. A thermometer and volumetric pipette will be calibrated and be used to experimentally determine the density of liquid water, which will be compared to the literature value with appropriate error analysis. Background Density is a physical characteristic unique to each pure substance. As a result, its value can be used to identify unknowns. The density of an object is defined in Eqn. 1. density = mass volume Eqn. 1 Knowing the density of an object also provides a conversion between an object s mass and its volume, or vice versa. In the laboratory it is often easier to measure a substance s mass instead of its volume, or volume instead of mass. 3-1

Example Problem: Calculating the Density of an Unknown Solid A 50.00 ml volumetric flask weighs 26.7500 g. The entirety of an unknown solid is added to the flask and reweighed at 30.1150 g. Deionized water is added to the calibration mark and the flask, sample, and water is reweighed at 74.9950 g. Calculate the density of the unknown solid, assuming the density of water is 0.998203 g/ml. Step 1: Find the mass of the unknown 30.1150 g 26.7500 g = 3.3650 g unknown Step 2: Find the mass of water added 74.9950 g 30.1150 g = 44.8800 g water Step 3: Find the volume of water added 44.8800 g 1 ml 0.998203 g = 44.9608 ml Step 4: Find the volume of the unknown 50.00 ml 44.961 ml = 5.04 ml Step 5: Find the density of the unknown 3.3650 g = 0.668 g/ml 5.04 ml Density is also dependent on temperature. In the lab, the most common devices used to measure temperature are the glass thermometers and the electronic Vernier temperature probes. Instruments contain some amount of uncertainty and error that must be determined by calibration and finding a correction factor, as seen in Eqn. 2. Much like density, the freezing and boiling point are also unique to a substance. The freezing and boiling point of water will be used to calibrate the glass thermometer as their values are tabulated and well-known. The boiling point of water is dependent on the surrounding atmospheric pressure, so that will need to be measured on the day of the experiment with the classroom barometer. T C = "0 -T s(freezing point)%+ (T A (boiling point)- T S (boiling point)) 2 Eqn. 2 Here, the correction factor (T C) is the error of the electronic temperature sensor. T s is the temperature recorded by the sensor and T A is the actual tabulated boiling point at that day s atmospheric pressure. Any temperature recorded by the temperature sensor should be corrected by adding the T C. 3-2

Example Problem: Finding TC A temperature sensor was used to record the freezing point of water as 0.112 C and the boiling point as 100.102 C. The actual boiling point of water on that day was tabulated at 99.982 C. The same sensor was then used to record the temperature of another substance at 72.355 C. Find the actual temperature of the second substance. Step 1: Find Tc T C = ( 0-0.112 ) +(99.982-100.102 ) 2 = -0.232 2 = -0.116 Step 2: Add TS + TC to find TA 72.355 C 0.116 C = 72.239 C Plotting the thermometer reading (T R) versus the actual temperature after correction (T A) for a set of temperatures will yield a linear equation that relates the two. This equation can continue to be used throughout the lab to convert any temperature taken by the thermometer to its actual, accurate temperature. Refer to Exercise 1 in this lab manual for instructions for graphing. Example Problem: Finding TA A graph of thermometer reading versus actual temperature had a linear trendline equation of y = 1.0382x 0.6525. The same thermometer was used to record a temperature of a sample as 20.4 C. Find the actual temperature of the sample. Step 1: Use the trendline to find the actual temperature (y). y = 1.0382(20.4) 0.6525 = 21.2 0.6525 = 20.5 C In the lab volume is typically measured either with a graduated cylinder or with volumetric glassware, such as a volumetric flask or pipette. Volumetric glassware has been previously calibrated for high precision and accuracy which can be tested by calibrating it with water as well. Recall that measurements in lab can be accurate, precise, both, or neither. These can be analyzed by determining percent error, standard deviation, and other error analysis on the numbers taken. Review Exercise 1 in this lab manual for more information. 3-3

Procedure Part I: Density of a Solid Unknown 1. Obtain a 50.00 ml volumetric flask from your instructor. Ensure that it is clean and dry and then weigh it empty. Record this weight in your data sheet. 2. Obtain a solid unknown from your instructor. Add the entire unknown to the volumetric flask and reweigh. Record this weight in your data sheet. 3. Fill the volumetric flask approximately halfway with deionized water with your wash bottle. Ensure that there are no solid pieces stuck in the neck of the flask. 4. Swirl and tap the flask and contents to remove any large air bubbles that may be trapped between the solid pieces. Tiny bubbles on the surface of the unknown may not be able to be removed. 5. With your wash bottle, add deionized water to reach the neck of the flask. Switch to a dropper and carefully add deionized water drop by drop until just below the flask s calibration m ark. 6. Use a piece of rolled paper towel to remove any drops from the neck of the flask that are above the calibration mark. 7. Use your dropper to very carefully add deionized water until the bottom of the meniscus is touching the calibration mark. Do not allow any water drops to remain in the neck of the flask above the calibration mark. 8. Weigh the volumetric flask, sample, and water. Record the weight in your data sheet. 9. Empty the flask s contents in the appropriate container (not the sink). Rinse the flask three times with deionized water and then leave on the assigned rack. 10. Use a glass thermometer and record the temperature of the deionized water in your wash bottle. 11. Calculate the density of your unknown. Assume that the density of water is 0.998203 g/ml. Part II: Thermometer Calibration 1. With a partner, obtain a Vernier GoDirect temperature probe and either a lab computer or a LabQuest 2 interface. If using a lab computer, make sure that the Graphical Analysis 4 program is already open. Connect the sensor to computer or interface using the USB cord. The current temperature of the probe in degrees C will be shown on the screen automatically (Fig. 1). Fig. 1: Temperature Sensor with LabQuest 2 3-4

2. Wrap the temperature probe s wire with aluminum foil to prevent damage. Slide a slit stopper onto the temperature probe from the bottom. 3. Set up a Bunsen burner beneath an iron ring and wire gauze. 4. In a 250 ml beaker, place approximately 125 ml of ice and 75 ml of tap water. Put this beaker on top of the wire gauze and use a second iron ring around it to avoid tipping. 5. Lower the temperature sensor into the ice water. If using a two-holed stopper, slide a glass thermometer into the second hole. Otherwise, use more split stoppers to hold each partner s glass thermometer. Clamp the sensor and the thermometers about 1 cm from the bottom of the beaker (not touching). 6. Gently stir the mixture with a glass stirring rod. When the temperature on the computer or LabQuest 2 stabilizes at or near 0 C, read each thermometer (T R) to the nearest 0.1 C and record these and the temperature sensor (T S) reading on your data sheet. 7. Raise the temperature sensor and thermometers. Empty the beaker and add approximately 200 ml of room temperature tap water (about 20 C) to it. 8. If the water is not at 20 C, use the Bunsen burner to heat it. Turn off the burner and return the temperature sensor and thermometers to 1 cm from the bottom of the beaker. Let the temperature stabilize for at least one minute and then read and record the temperature on the sensor and thermometers. Record the temperatures on your data sheet. 9. Repeat Step 8, this time heating the water to approximately 40 C before turning off the burner, letting it stabilize, and recording the temperatures. Repeat Step 8 again to approximately 60 C, 80 C, and then finally when the water reaches a gentle boil. Record the temperatures on both sensor and thermometer each time. 10. Record the atmospheric pressure from the classroom barometer for the day. Use this to look up the tabulated boiling point of water at this pressure. 11. Calculate the correction factor (T c) for the temperature sensor, and then use it to find the actual temperature (T A) at the recorded 20, 40, 60, and 80 C (not ice or boiling). 12. Graph thermometer reading (x-axis) versus actual temperature (y-axis), add a linear trendline, and record the trendline equation. Part III: Pipette Calibration 1. Fill a 250 ml beaker approximately half full with deionized water. Take the temperature of the water with a glass thermometer and record this in your data sheet. 2. Weigh a clean, dry 125 ml Erlenmeyer flask with cork stopper. Record this weight in your data sheet. 3. Fill the 5 ml volumetric pipette completely with deionized water, being sure to not get any liquid into the rubber bulb. Allow the pipette to drain into the sink. It should drain completely, leaving only a drop or two in the very tip of the pipette. If so, move on to Step 5. 3-5

4. If the pipette does not drain completely (droplets are left along the inside of the glass), clean it with a hot soap solution. Heat approximately 50 ml of deionized water to boiling and then add a few drops of dish soap and stir. Using the rubber bulb, pull the soap solution up and down the pipette vigorously for at least a minute. Then use the bulb to fill the pipette with tap water and drain, then deionized water and drain, to rinse. If drops still cling to the inside of the pipette, see your instructor for a replacement. 5. Using the rubber bulb, measure 5.00 ml of deionized water from the beaker you prepared in Step 1 with your volumetric pipette and transfer it to the Erlenmeyer flask in Step 2. 6. Stopper the flask and reweigh, recording the weight in your data sheet. 7. Repeat Steps 5-6 four more times, for a total of five portions of 5.00 ml water added to the Erlenmeyer. Do not empty the flask in between portions; there should be 25.00 ml total inside the Erlenmeyer flask when finished. 8. Find the individual masses of each 5.00 ml portion of water added. 9. Use the trendline equation from Part II to convert the temperature you recorded in Step 1 to the actual temperature. 10. Look up the density of water at this actual temperature in Step 9. 11. Use the density of water found in Step 10 to convert the masses in Step 8 to volume. 12. Calculate the average volume and standard deviation. Part IV: Density of a Solid Unknown Correction 1. With the temperature recorded in Part I Step 10, use the trendline from Part II to convert the temperature to actual temperature. 2. Look up the density of water at this actual temperature in Step 1. 3. Recalculate the density of the unknown, this time using the actual density of water found in Step 2. 4. Calculate the percent error between the density originally found in Part I and the new density in Step 3, using Part I s density as the experimental value and Part IV s as the theoretical. 3-6

Experiment 3 Data Sheet Name: Part I: Density of a Solid Unknown 1. Mass of volumetric flask (g) 2. Mass of flask and sample (g) 3. Mass of flask, sample, and water (g) 4. Water temperature ( C) 5. Mass of sample (g) 6. Mass of water (g) 7. Volume of water added (ml) 8. Volume of sample (ml) 9. Density of sample (g/ml) 3-7

Part II: Thermometer Calibration Thermometer Reading (T R C) Sensor Reading (T S C) Actual Temperature (T A C) 0 C (ice) T A (boiling) = 1. Temperature Correction (T c, C) 2. Trendline equation (from graph) Part III: Pipette Calibration 1. Temperature of water ( C) 2. Mass of flask (g) 3. Mass of flask + first 5.00 ml H 2O (g) 4. Mass of flask + second 5.00 ml H 2O (g) 5. Mass of flask + third 5.00 ml H 2O (g) 6. Mass of flask + fourth 5.00 ml H 2O (g) 3-8

7. Mass of flask + fifth 5.00 ml H 2O (g) 8. Mass of first 5.00 ml H 2O (g) 9. Mass of second 5.00 ml H 2O (g) 10. Mass of third 5.00 ml H 2O (g) 11. Mass of fourth 5.00 ml H 2O (g) 12. Mass of fifth 5.00 ml H 2O (g) 13. Corrected temperature of H 2O ( C) 14. Density of H 2O (g/ml) 15. Volume of first 5.00 ml H 2O (ml) 3-9

16. Volume of second 5.00 ml H 2O (ml) 17. Volume of third 5.00 ml H 2O (ml) 18. Volume of fourth 5.00 ml H 2O (ml) 19. Volume of fifth 5.00 ml H 2O (ml) 20. Average volume pipetted (ml) 21. Standard deviation (s) 22. Result (x( ± s) 3-10

Part IV: Density of a Solid Unknown Correction 1. Corrected temperature from Part I ( C) 2. Corrected density of water (g/ml) 3. Corrected density of unknown (g/ml) 4. Percent Error (%) 3-11

Experiment 3 Post-Lab Assignment 1. A student performed the identical experiment as described in Part I to find the density of an unknown solid. They completed every step perfectly excep they did not remove several large air bubbles trapped in between the solid unknown pieces. What effect (too high, too low, no effect) will this have on the calculated density of their unknown? Explain. You may use diagrams to explain. 2. A student finds their standard deviation in Part III to be very small for the volume of water dispensed by the pipette. Does this mean that the student has a small random or small systematic error? Are the student s results precise? Are they accurate? Explain. 3. In Part I if you fail to remove all the water from the neck of the volumetric flask above the calibration line, how would this affect (too high, too low, no effect) the weight of the mass, flask, sample, and water? How will this affect the calculated density of your unknown? Explain. 3-12

4. Convert the corrected density of your solid unknown from Part IV into the following units. Show all your work. a. pounds/ft 3 b. tons/yard 3 c. kilograms/liter 3-13

Experiment 3 Pre-Lab Assignment Name: For all calculations, show all work and draw a box around the final answers. 1. A 100.00 ml volumetric flask weighs 35.9325 g. When an unknown solid is added to it, the flask and sample weigh 48.8565 g. Deionized water is added to the calibration mark. The flask, sample, and water together weigh 140.8321 g. Calculate the density of the unknown, assuming the density of water is 0.998203 g/ml. 2. What two measuring devices are being calibrated in this experiment? 3. The following volumes were obtained during the calibration of a 10.00 ml pipette: 10.15 ml, 9.95 ml, and 10.02 ml. Calculate the average and the standard deviation. Report your answer as x( ± s. 3-14