FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

Similar documents
Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

International Journal of Advanced Engineering Technology E-ISSN

International Journal of Engineering Research and General Science Volume 3, Issue 6, November-December, 2015 ISSN

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS

FLUID FLOW AND HEAT TRANSFER INVESTIGATION OF PERFORATED HEAT SINK UNDER MIXED CONVECTION 1 Mr. Shardul R Kulkarni, 2 Prof.S.Y.

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Ali S. Sharbuddin, International Journal of Advance Research, Ideas and Innovations in Technology.

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Forced Convection Heat Transfer Augmentation from Ribbed Surface

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct

International Engineering Research Journal Experimental investigation of Forced convective heat transfer coefficient from W shaped ribbed surface

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

ENHANCEMENT OF HEAT TRANSFER FOR AIR FLOW THROUGH A DUCT WITH VARIOUS RIBS

Heat Transfer Enhancement and Thermal Performance of Extended Fins

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

CFD analysis of solar air heater having absorber plate roughened with compound turbulators

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Experimental Analysis of Heat Transfer Enhancement through Pipe using Baffles

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA

CFD AND CONJUGATE HEAT TRANSFER ANALYSIS OF HEAT SINKS WITH DIFFERENT FIN GEOMETRIES SUBJECTED TO FORCED CONVECTION USED IN ELECTRONICS COOLING

CFD study for cross flow heat exchanger with integral finned tube

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Empirical assessment of heat transmission and pressure loss in turbojet blades

3D Numerical Study on Laminar Forced Convection in V-Baffled Square Channel

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Empirical study of heat transfer at input area of turbojet blades

EXPERIMENTAL STUDY OF HEAT TRANSFER AND PRESSURE LOSS IN CHANNELS WITH MINIATURE V RIB-DIMPLE HYBRID STRUCTURE

TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

An experimental study on heat transfer for a tilted semi-cylindrical cavity with inclined ribs

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS

EVALUATION OF THERMAL PERFORMANCE OF CONE SHAPED HELICAL COIL HEAT EXCHANGER BY USING CFD ANALYSIS

TABLE OF CONTENTS CHAPTER TITLE PAGE

Numerical Analysis of Fe 3 O 4 Nanofluid Flow in a Double Pipe U-Bend Heat Exchanger

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Experimental Investigation of Heat Transfer Analysis of Ribbed Duct for Thermal Performance Enhancement

COMPUTATIONAL ANALYSIS OF LAMINAR FORCED CONVECTION IN RECTANGULAR ENCLOSURES OF DIFFERENT ASPECT RATIOS

Experimental Analysis for Natural Convection Heat Transfer through Vertical Cylinder

NUMERICAL SIMULATION OF FLOW THROUGH TURBINE BLADE INTERNAL COOLING CHANNEL USING COMSOL MULTIPHYSICS

The Effect of Solid and Perforated Pin Fin on the Heat Transfer Performance of Finned Tube Heat Exchanger

Experimentation and Performance Evaluation of Heat Exchanger Using Z-Ribs

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

Estimation of Heat Transfer in Internally Micro Finned Tube

Heat Transfer Analysis of a Helical Coil Heat Exchanger by using CFD Analysis

E ects of Corrugation Pro le on the Heat Transfer Rate of Fins

COMPUTATIONAL FLUID DYNAMICS ON DIFFERENT PASSAGES OVER A PLATE COIL EVAPORATOR FOR 40 LITER STORAGE TYPE WATER COOLER

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

Chapter 3. CFD Analysis of Radiator

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

Modelling and Parametric fluid flow Analysis (CFD) of convergent nozzle used in pelton turbine

LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM AN ISOTHERMAL VERTICAL RIBBED PLATE

Simulation of Free Convection with Conjugate Heat Transfer

THE HEAT TRANSFER ENHANCEMENT TECHNIQUES A REVIEW

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate

Numerical Investigation of Multijet Air Impingement on Pin Fin Heat Sink with Effusion Slots

Performance of Elliptical Pin Fin Heat Exchanger with Three Elliptical Perforations

PERFORMANCE ANALYSIS OF CORRUGATED PLATE HEAT EXCHANGER WITH WATER AS WORKING FLUID

FLOW SIMULATION AND HEAT TRANSFER ANALYSIS USING COMPUTATIONAL FLUID DYNAMICS (CFD)

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

An Experimental Study on Heat Transfer Enhancement of Flat Plates Using Dimples

ENGR Heat Transfer II

Transcription:

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER 1 Navanath.G.Ghodake, 2 Prof.MRC. Rao, 3 Dr. R. R. Arakerimath 1 ME heat power student, 2 professor, 3 Professor & Dean 1,2,3 Mechanical Engineering Department 1, 2,3 G.H Raisoni college of engineering & Management, Wagholi, Pune, India. Abstract Heat transfer enhancement techniques are used in heat exchanger systems in order to enhance heat transfer and improve the thermal performance. Several methods are applied in order to improve thermal performance of heat transfer device such as treated surface, rough surface and incorporation of inserts. My work focuses on use of various Ribs to enhance heat transfer. The bed wall destabilized the flow. The separations and reattachments over the bed wall increase fluid mixing, create flow unsteadiness, interrupt the development of the thermal boundary layer and enhance the heat transfer. In this paper CFD analysis of different shape s such as V-s, (simple and broken v-s), triangular and rectangular s placed in rectangular duct has been performed. The work carried out in two stages: 1. Modeling of s for different shapes. It has been done in CATIA. 2. Analysis of flow and predict the best suited Rib among the various s considered. Analysis has been done in ANSYS CFD. Index Terms heat transfer enhancement, Ribs, V and Broken v s, CFD analysis of s... I. INTRODUCTION (HEADING 1) Ribs are used on heat exchange surfaces to promote turbulence and enhance convective heat transfer. Roughness elements such as s are mounted on walls have been widely used in engineering applications to enhance heat transfer, for example, heat exchangers and mixing chambers, turbine blade cooling. Computational fluid dynamics (CFD) is the science of predicting the fluid flow, heat and mass transfer, chemical reactions, and related phenomenon. To predict these phenomena CFD solves equation for conservation of mass, momentum, energy etc. with a numerical manner on a computer. Computer is used to perform the calculation required to simulate the interaction of liquids and gases with surface defined by boundary condition. In this paper CFD analysis of flow through rectangular duct on surfaces of different shapes such as rectangular, triangular, v- with 45 degree, v with 60 degree, broken v s, semicircular v s. Has been performed. The work carried out in two stages: 1. Modeling of different shaped s mentioned above. It has been done in CATIA. 2. Analysis of flow and predict the best suited among the s considered. Analysis has been done in ANSYS CFD. The objectives of this study is, 1. To predict the flow behavior of various s. 2. To investigate the best suited Rib that gives high heat transfer rate. 3. To investigate the best suited that gives high thermal performance. Recently some researcher works on CFD analysis for heat transfer enhancement devices are [1] Sandip jaiswal and Dr K.R.Aharwal They work on three dimensional CFD simulations to investigate heat transfer and fluid flow characteristics of artificially roughened duct, And they conclude that Heat transfer performance decreases with an increment of Reynolds number for both the roughness pattern, and reasonable difference is found between the heat transfer simulation data for different roughness configurations, and the Ansys-Fluent software has been sufficient for simulating the flow field in rectangular duct. [2] Miss. Ashwini Vasant Thakare, Dr. J. A. Hole-They work on an experimental investigation for heat transfer enhancement with the help of three shapes of for heat exchanger application. They conclude that the heat transfer in rectangular duct with different - shaped s is found to be more as compared to without s. [3] Shital B. Salunkhe, Dr.Rachayya R.Arakerimath- They work on the experimental and CFD analysis of different fins. They concluded that CFD and experimental result shows that copper material having high heat transfer coefficient. [4] Suman Saurav, V.N.Bartaria -This paper presents The study of heat transfer in a rectangular duct of a Solar air heater having triangular roughness on the Absorber plate by using Computational Fluid Dynamics (CFD). It has been found that the nusselt number increases with increase in Reynolds number. [5] Ravi Teja, Pathan F Z, Mandar Vahadne- Simulation study has been conducted on the response of turbulent flow in a rectangular duct in order to evaluate the heat transfer rate along rectangular. A result shows that the correlation between flow structure and heat transfer is found to be strong. It is found that the onset of flow oscillations is important as it dramatically enhances heat transfer. [6] Bhattacharyya et al. Presented experimental friction factor and Nusselt number data for laminar flow through a circular duct having integral transverse s and fitted with center-cleared twisted-tape have been presented. Predictive friction factor and Nusselt number correlations have also been presented. The thermo hydraulic performance has been evaluated. The major findings of this experimental investigation are that the center-cleared twisted tapes in combination with transverse s perform significantly better than the individual enhancement technique acting alone for laminar flow through a circular duct up to a certain amount of center-clearance. This result is useful for the design of solar thermal heaters and heat exchangers JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 42

[7] Onur yemenici and Habib Umur -works on experimental study of convective heat transfer of flows over concave,convex, and consecutive bed walls in a turbulent boundary layer were studied. Outcome of his work is the measurements indicate that the concave and bed wall effectively enhances the heat transfer performance while convex wall reduced. [8] Giovanni Tanda-works on Heat transfer in rectangular channels with transverse and V-shaped broken s. Results were such that features of the inter- distutions of the heat transfer coefficient are strongly related to shape and Geometry and Transverse broken s, in a staggered arrangement, lead to higher levels of turbulence over the heated surface. [9] J. C. Han and J. S. Park studied Developing heat transfer in rectangular channels with turbulators and Experimental results were compared for various angular positions of. [10] P.R. Chandra a, C.R. Alexander, J.C. Han studied the Heat transfer and friction behaviors in rectangular channels with varying number of bed walls. An experimental study of surface heat transfer and friction characteristics of a fully developed turbulent air flow in a square channel with transverse s on one, two, three, and four walls is reported. The Heat transfer coefficient and friction factor results were enhanced with the increase in the number of bed walls. II. MODELING OF RIBS USING CATIA: There are 10 different types of s used in this project for analyzing the best out of them. These s are as follows: 1. Rectangular. 2. Rectangular with taper. 3. Triangular. 4. Triangular broken. 5. V- (45 degree). 6. Broken V (45 degree). 7. V (60 degree). 8. Broken V (60 degree). 9. V semicircular. 10. Broken V semicircular. These s are modeled by using CATIA as shown below, and there dimensions are: All s having height of 6mm and pitch 50mm so there will be pitch to height ratio,p/e=8.3and broken s having a break of 2mm. 1. Rectangular 2. Rectangular with taper 3. Triangular 4. Triangular broken 5. V (45 degree) 6. Broken V (45 degree). JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 43

7. V (60 degree) 8. Broken V (60 degree) 9. V semicircular (45 degree) 10. Broken V semicircular (45 degree) III. COMPUTATIONAL FLUID DYNAMICS: - Computational Fluid Dynamics (CFD) is the science of predicting fluid flow, heat and mass transfer, chemical reactions, and related phenomena. To predict these phenomena, CFD solves equations for conservation of mass, momentum, energy etc., with a numerical manner on a computer. The CFD analysis provides useful data and information which can be used as basis for making experimentation of our project.it will helps us to understand that how we will get results after doing experimentation of our project. 3.1 Operating parameters: Sr.no Inputs Values 1 Velocity of air 1 m/s 2 Operating temperature 321 k 3 Operating pressure 1.013 bar 4 Air density 1.184 kg/m 3 5 Fluid Air 6 Duct size 2100x200x150mm 7 Plate material Acrylic 8 Rib material Copper 3.2 Steps in CFD Analysis:- 1. Modeling of component using CATIA software. 2. Conversion of CAD model into.igesformat. 3. Import the.iges (Initial graphics exchange specification) format in to ANSYS workbench. 4. To select the process under which we want to analyze the imported model. (In our case fluent analysis). 5. Next we define enclosure, for the model. 6. Meshing of model. 7. Setup the model foranalysis; by applying all the constraints. 8. Run the solver. 9. Generate thermal graphs from results and solution section. JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 44

3.3 Temperature contours for s after analysis:- 1. Rectangular. 6. Broken V (45 degree) 2. Rectangular taper Rib. 7. V (60 degree) 3. Triangular Rib. 8. Broken V (60 degree) 4. Triangular broken 9. V semicircular(45 degree) 5. V (45 degree) 10. Broken V semicircular JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 45

3.4 Result and discussion:- Table 3.4.1- Temperature results. Name of Maximum Minimum temperature(k) temperature( k) Rectangular 321.0604 321.0225 Rectangular taper 321.1028 321.0786 Triangular 321.0472 321.0242 Triangular broken 320.9643 320.9507 V (45 degree) 320.9266 320.9095 Broken v (45 323.411 312.44 degree) V (45 degree) 321.009 320.990 semicircular Broken V (45 321.0 320.9923 degree) semicircular V (60 degree) 320.93 320.8740 Broken V (60 degree) 320.9684 320.9450 Table 3.4.2- Heat flux & heat transfer coefficient Rib Maximum Heat flux Heat transfer coefficient.(w/m2k) (w/m2) Rectangular 28 76 Rectangular taper 29 78 Triangular 27 19 Triangular broken 10 29 V 45 26 28 V 45 break 28 74 V 45 semi 24 19 V 45 semi break 23 20 V 60 25 38 V 60 break 26 41 Discussion:- Analysis is done for different types of s placed in a rectangular duct of cross section 2100x150x200 mm. a heated air of temperature 321K was passed over the s. We will assume that as best geometry of s to enhance the heat transfer rate whose temperature will be highest after heated air is passed over it. From above all temperature contour graphs we understand that temperature is highest for broken v 45 degree i.e.323.411k, rectangular taper having good temperature as 321.1028K and also heat flux values and heat transfer coefficient values we can understand that rectangular taper and V 45 broken having much good analysis resultsamongst all other s. IV. FUTUREWORK: - From above results we are going to manufacture the s and for them we are going to take experimental results by placing it actually in rectangular duct and passing hot air by forced convection over it and taking readings for temperature, heat flux and heat transfer coefficient. 4.1 Experimental set up JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 46

4.1.1 Experimental Methodology 1. Fit the specimen inside the duct which consists of a nine thermocouples inside a Duct to measure the temperature at various points of ducts and specimen. 2. Switching ON the supply and adjust the voltage at 60 V, 120 V and 180 V. 3. Switching ON the blower units and allowing the flow of air. 4. Measure the flow of air through anemometer. 5. After attaining the steady stage note the temperature (T1 to T9) at an interval of 10 minutes and tabulate it 6. Repeat same procedure for other specimens also. 7. Compare the result of three Design and Material specimens analytically and 8. Conduct CFD Analysis of the same. 9. The Results obtained will be Heat Transfer Coefficient, Reynolds number and Nusselt Number. V. CONCLUSIONS 1. The results obtained by CFD analysis shows that we Get the temperature of 321.102K with the maximum heat flux of 29 w/m2 and maximum heat transfer coefficient of 78 w/m2 k for Rectangular taper. 2. The results also shows that broken v (45degree) has highest temperature of 323K,with maximum heat flux of 28 w/m2 and maximum heat transfer coefficient of 76 w/m2. REFERENCES [1] Sandip jaiswal and Dr K.R.Aharwal (2015), Three dimensional cfd analysis of rectangularroughened channel, IJERT, 106-111. [2] Miss. Ashwini Vasant Thakare, Dr. J. A. Hole (2016) Experimental validation of heat transfer enhancement in plate heat exchanger with non conventional shapes of IJSETR,733-739. [3] Shital B. Salunkhe, Dr.Rachayya R.Arakerimath (2015), Cfd and experimental analysis of various extended surfaces for heat transfer enhancement,ijetmas, 192-196. [4] Suman Saurav, V.N.Bartaria, (2013), Cfd analysis of heat transfer through artificially roughened solar duct, IJETT, 3936-3944. [5] Ravi Teja, Pathan F Z, Mandar Vahadne, (2015) optimization of heat transfer through rectangular duct,irjet, 1906-1910. [6] Bhattacharyya et al,(2012),thermohydraulic of laminar flow through a circular tube having integral helical roughness and fitted with center cleared twisted tape, Experimental Thermal And Fluid Science,154-162. [7] Onur yemenici and Habib Umur, (2013),Thermal characteristics of turbulent flows under the effects of, curvature and Reynolds number, IJAET, 1070-1075. [8] Giovanni Tanda, (2004), International Journal Of Heat and Mass Transfer, 229-243. [9] J. C. Han and J. S. Park,(1988),Developing heat transfer in rectangular channels with turbulators, International Journal Of Heat And Mass Transfer,183-195. [10] P.R. Chandra a, C.R. Alexander, J.C. Han,(2003),Heat transfer and friction behaviors in rectangularchannels with varying number of bed walls,international Journal Of Heat And Ma JETIR1607010 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 47