Calculating standard captured spectra of formation elements

Similar documents
DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Neutron Detection. n interactions with matter n detection High/low energy n detectors

MC simulation of a PGNAA system for on-line cement analysis

Neutron Log. Introduction

Neutron Shielding Properties Of Concrete With Boron And Boron Containing Mineral

Monte Carlo modelling of a NaI(Tl) scintillator detectors using MCNP simulation code

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

A MONTE-CARLO STUDY OF LANDMINES DETECTION BY NEUTRON BACKSCATTERING METHOD

Key Laboratory of Geo-detection (China University of Geosciences, Beijing), Ministry of Education, Beijing , China

Compton suppression spectrometry

Chapter 2 Methods Based on the Absorption of Gamma-Ray Beams by Matter

THE USE OF THE MCNP CODE FOR THE QUANTITATIVE ANALYSIS OF ELEMENTS IN GEOLOGICAL FORMATIONS

Monte-Carlo Simulation of Response Functions for Natural Gamma-Rays in LaBr 3 Detector System with Complex Borehole Configurations

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

SCIENCE CHINA Physics, Mechanics & Astronomy

CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

Basics of Geophysical Well Logs_Porosity

MCNP TRANSPORT CODE SYSTEM & DETECTOR DESIGN

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Study well-shaped germanium detectors for lowbackground

6 Neutrons and Neutron Interactions

Neutron collimator design of neutron radiography based on the BNCT facility arxiv: v1 [physics.ins-det] 3 May 2013

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

CRaTER Science Requirements

THE COMPTON EFFECT Last Revised: January 5, 2007

Sample Spectroscopy System Hardware

Gamma ray coincidence and angular correlation

Gamma-ray emission by proton beam interaction with injected Boron atoms for medical imaging. Giada Petringa - Laboratori Nazionali del Sud -

Quality Assurance. Purity control. Polycrystalline Ingots

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

The sensitivity of the array resistivity log to mud. inversion for improved oil water recognition

FORMATION EVALUATION PETE 321

Experimental Studies on the Self-Shielding Effect in Fissile Fuel Breeding Measurement in Thorium Oxide Pellets Irradiated with 14 MeV Neutrons

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

GAMMA RAY SPECTROSCOPY

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

6th International Conference on Information Engineering for Mechanics and Materials (ICIMM 2016)

The effective pressure law for permeability of clay-rich sandstones

Detection and measurement of gamma-radiation by gammaspectroscopy

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

ARTICLE IN PRESS. Applied Radiation and Isotopes

MUDLOGGING, CORING AND CASED HOLE LOGGING BASICS COPYRIGHT. Cased Hole Logging. By the end of this lesson, you will be able to:

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Calculation of Irreducible Water Saturation (S wirr ) from NMR Logs in Tight Gas Sands

Fundamentals of Radionuclide Metrology

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

GEOLOGICAL LOG INTERPRETATION TUTORIAL

Exploring for oil with nuclear physics

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

Neutron and gamma ray measurements. for fusion experiments and spallation sources

SUPER-ABSORPTION CORRELATION BETWEEN DEUTERIUM FLUX AND EXCESS HEAT

The Ones That Got Away: Neutron Leakage Spectra

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Experimental Activities in China

Formation Evaluation: Logs and cores

Measurements of the gamma-quanta angular distributions emitted from neutron inelastic scattering on 28 Si

Simple Experimental Design for Calculation of Neutron Removal Cross Sections K. Groves 1 1) McMaster University, 1280 Main St. W, Hamilton, Canada.

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

Slides by: Prof. Abeer Alharbi

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Calibration of EJ-301, a Liquid Scintillator

Characterization and Monte Carlo simulations for a CLYC detector

INTRODUCTION TO WELL LOGS And BAYES THEOREM

Gamma Spectroscopy. References: Objectives:

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

MCNP analysis and optimization of a double crystal phoswich detector

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Mossbauer Effect and Spectroscopy. Kishan Sinha Xu Group Department of Physics and Astronomy University of Nebraska-Lincoln

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

New Scintillators for the Border Monitoring Equipment

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Open Access Study on Reservoir-caprock Assemblage by Dual Logging Parameter Method

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Copyright 2008, University of Chicago, Department of Physics. Gamma Cross-sections. NaI crystal (~2" dia) mounted on photo-multiplier tube

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Log Interpretation Parameters Determined from Chemistry, Mineralogy and Nuclear Forward Modeling

Detector Sensitivity

Contrabands detection with a low energy electron linac driven photoneutron source

Nuclear Decays. Alpha Decay

ECS Elemental Capture Spectroscopy Sonde. Fast, accurate lithology evaluation

Spectroscopy on Mars!

Characterizations and Diagnostics of Compton Light Source

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Radioactivity and Radioactive Decay

Submitted to Chinese Physics C

High precision neutron inelastic cross section measurements

Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations

Transcription:

1007/s12182-012-0231-8 463 Calculating standard captured spectra of formation elements Wu Wensheng, Xiao Lizhi, Zhang Lijuan and Niu Wei State Key Laboratory of Petroleum Resource and Prospecting, China University of Petroleum, Beijing 102249, China China University of Petroleum (Beijing) and Springer-Verlag Berlin Heidelberg 2012 Abstract: Multi-element gamma-ray spectrum logging requires standard spectra of individual elements for its interpretation. Since the standard element spectra are usually derived using Monte Carlo simulation be observed using a NaI(Tl) detector) of elements H, Si, Ca and Fe from each element and its oxide. To compare the standard spectra from the elements and oxides, we operated three simulations of sandstone, limestone and mixed formation of sandstone and limestone each with ten different porosities, and used the two kinds of standard spectra to analyze the mixed spectra modeled from sandstone and limestone formations. The results show that the standard element spectra from oxides have more prominent energy peaks than the standard spectra from pure elements. The calculated formation element contents are close to the theoretical values when the standard element spectra from oxides are used to analyze the formation mixed spectra. Therefore, the formation element standard spectra should be calculated from oxide models in the analysis of neutron captured spectra by logging tools. Key words: Standard spectrum, spectrum analysis, neutron captured spectrum, formation element 1 Introduction Multi-element spectrum logging can effectively identify lithology and mineralogy in formations, and plays an important role in exploring complex reservoirs (Hertzog et al, 1989; Chapman et al, 1987; Grau and Schweitzer, 1989; Grau et al, 1990). Accurate and effective full spectrum analysis logging, and the spectrum analysis method requires simulated There are two ways to acquire standard element spectra, one is instrument measurement in a standard calibration model, and the other is numerical simulation (Nguyen et al, 1996; Al-Ghorabie, 2006; Shi et al, 2002; Xiang and Guo, 2006). As numerical simulation can not completely take the real tool and well conditions into account, it is better to obtain the standard spectra with a spectrum tool in a model well. Owing to a variety of reasons, almost all publications do not describe elements or compounds used to synthesize standard element spectra in the model well. Generally, either a pure element or its oxide can be used to obtain standard element spectra by Monte Carlo modeling. With the Monte Carlo numerical simulation program MCNP(5C) (Pei and Zhang, 1980), we studied the differences of spectrum analysis using standard spectra calculated either from pure elements or their oxides. 2 Numerical simulation model The calculation model is a cylinder with a height of 1 m and a radius of 70 cm, as shown in Fig. 1. The diameter of the logging tool with a pulsed neutron source is 45 mm. The source emits 14 MeV neutrons into the formation with a pulse detector 40 cm away from the source and the detector is 10 cm in length and 4 cm in diameter. The tool is pressed closely up against one side of the borehole. The space between the detector responses are considered in the calculation. Detector Source Borehole Formation *Corresponding author. email: wwsheng@yahoo.com.cn Received January 5, 2012 Fig. 1 The calculation model

464 A two-step simulation is used in the calculation. First is the simulation for neutrons. When photons are generated, the position where photons are generated is treated as the departure position. The energy and motion direction of the photons are determined by random sampling of the known energy distribution and motion direction distribution, thus the second step simulation begins (Hendriks et al, 2002). The advantages of this two-step simulation are significant whole energy, single escape and double escape peaks, short computation time, and low calculation error generally less than %. 3 The simulation for standard element spectra in formation elements With the above calculation model and calculation techniques, the next most critical step is filling the element in the model for standard spectrum simulation. Since the standard element spectrum is the detector response of the logging tool to a transient nuclear reaction of atomic nuclei in the borehole, pure substances are first considered to be filled in the model to simulate element standard spectra. In computation, the pure element in the model is respectively H, in Fig. 2. The inelastic scattered gamma counts are deducted from the captured spectra counts in Fig. 2. Because the spectra are obtained between two neutron pulses, the spectra gamma rays. interact with the atoms of the materials behind the detector back at the detector, are detected and form the backscattered low-energy peak. As well, backscattered photons produced in shielding materials also contribute to the backscattered peak. The energy of backscattered photons is always around 200 kev, so it is easy to identify the backscattered peak in the spectrum. 3.2 The simulation for the formation filled with element oxide Considering the element in the strata is not a pure element, but an oxide form, for example, element H occurs as H 2 O, and Si occurs as SiO 2 2 O, SiO 2, CaCO 3, and FeO, and the calculated captured spectra are shown in Fig. 3. Relative intensity 100 10 1 0 H 2 O SiO 2 CaCO 3 FeO 2 4 6 8 Energy, MeV Fig. 3 Relative intensity 10 1 1E-3 0 H Ca Fig. 2 Captured spectra of H, Si, Ca and Fe Si Fe 1 2 3 4 5 6 7 8 Energy MeV Fig. 2 shows that there is a characteristic peak of H at 2.23 MeV; two whole energy peaks of Si appear at 3.54 MeV and 4.93 MeV; Ca peaks are at 1.94 MeV and 6.42 MeV; Fe peaks are at 7.46 MeV and 5.92 MeV (Huang, 1985). In the figure, the first peak on the left is the backscattered peak. through the detector crystal without being detected. They then To compare the differences of spectra in Fig. 2 and Fig. 3, the spectra of Si and SiO 2 are taken as an example shown in Fig. 4. Fig. 4 shows that compared with the spectrum of pure element Si, the characteristic peak positions of the SiO 2 spectrum do not change but its peaks are more prominent, especially the characteristic peak at 4.93 MeV. The characteristic peaks in the spectra of other oxides are also more prominent than those in corresponding pure element spectra. Some small peaks in SiO 2 spectrum are due to the presence of element O. The standard captured spectrum of Si can be obtained by doing mathematical algorithm processing to remove the oxygen peaks from the spectrum of SiO 2. 4 Comparison of energy spectrum analysis results 4.1 Sandstone with different porosities In order to compare the spectrum analysis results based on the above two types of element standard spectra, it is assumed that there is a sandstone reservoir with different porosities from 1% to 45% corresponding to ten points, and the pore is

465 1 2005; Pang and Li, 2006): Wt F y / S j j j (2) Normalization count C H and C Si represent the weight percentage of H and Si respectively, and b is formation density. Table 1 Sandstone formation model with different porosities Point C H C Si Porosity % b g/cm 3 1 36.70 1 2.634 2 0.06 36.12 5 2.568 3 2 35.36 10 2.485 4 9 34.54 15 2.403 5 0.26 33.67 20 2.320 6 0.34 32.73 25 2.238 7 0.42 31.71 30 2.155 8 0.51 30.62 35 2.073 9 0.61 29.44 40 1.990 10 0.71 28.15 45 1.908 The program MCNP (5C) is used to simulate the captured analysis, the element standard spectra are isolated from the oxide spectra by mathematical processing, and these element standard spectra are called oxide standard spectra. The standard spectra assuming pure elements are called pure element standard spectra. To conveniently perform mathematical processing, the standard spectra and formation mixed spectra are expressed as 256-dimensional vector P and the components are normalized according to Eq. (1) 256 P 1 1 Energy, MeV Fig. 4 Comparison of Si and SiO 2 spectra SiO 2 0 2 4 6 With oxide standard spectra and pure element standard spectra, a full spectrum least-square method is used to analyze the mixed spectra for the ten points in Table 1 and obtain the relative yields of H and Si. In order to calculate the weight percentage of each element with the oxide model, each point in Table 1 is calibrated to get the normalization factor F and sensitivity factor S, and then the weight percentages of elements at each point are calculated by Eq. (2) (Pang et al, Si (1) Fig. 5 and Fig. 6 show the weight percentages of H and Si acquired respectively with the oxide standard spectrum and pure element standard spectrum. The x-axis indicates the theoretical composition of the element in the formation, the y-axis represents the calculated element content, and the value is equal to the theoretical value. Fig. 5 shows that the H content obtained from a pure element standard spectrum is higher than the corresponding theoretical value. The content of H based on oxide standard spectrum is lower than the corresponding theoretical value for low porosities, and higher than the corresponding theoretical value for high porosities. On the whole, the analysis results using the oxide standard spectrum are closer to the diagonal dashed line than those of the pure element standard spectrum, which demonstrates that spectrum analysis with the standard spectrum calculated from the oxide can provide a more accurate estimate of the hydrogen content. 0.0075 0.0060 0.0045 0.0030 H 0.0015 0.0000 0.0000 0.0015 0.0030 0.0045 0.0060 0.0075 Fig. 5 Weight percentage of H based on sandstone model Fig. 6 shows that the content of Si calculated from the oxide standard spectrum is extremely close to the corresponding theoretical value, and the content derived from the pure element standard spectrum is lower than the corresponding theoretical value. The lower the formation porosity, the higher the deviation degree. Therefore, according to the spectrum analysis results in sandstone formation, the computation accuracy of element content with oxide standard spectrum is better than that with pure element standard spectrum. 4.2 Limestone with different porosities To compare the spectrum analysis results for oxide standard spectrum and pure element standard spectrum, it is assumed that there is a limestone reservoir with the porosity

466 0.375 Si 0.360 0.03 H 0.345 0.02 0.330 0.315 0.300 0.285 0.00 0.270 0.270 0.285 0.300 0.315 0.330 0.345 0.360 0.375 Fig. 6 Weight percentage of Si based on sandstone model 0.00 0.02 0.03 Fig. 7 Weight percentage of H based on limestone model from 1% to 45% corresponding to ten points, and the pores Table 2, C H and C Ca stand for the weight percentages of H and Ca respectively. Table 2 Limestone formation model with different porosities Point C H C Ca Porosity % b g/cm 3 1 0.04 31.70 1 2.693 2 0.21 31.21 5 2.625 value, it is still close to it. The content of Ca from a pure element standard spectrum is significantly higher than the corresponding theoretical one. Therefore, from the spectrum analysis results in the limestone formation, the accuracy of the element content calculated from the oxide standard spectrum is better than that from the pure element standard spectrum. 0.32 Ca 3 0.44 30.57 10 2.539 4 0.68 29.87 15 2.454 5 0.94 29.13 20 2.368 6 1.22 28.33 25 2.283 7 1.52 27.47 30 2.197 8 1.84 26.54 35 2.112 9 2.19 25.54 40 2.026 0.30 0.28 0.26 10 2.58 24.44 45 1.941 The analysis results with an oxide standard spectrum and pure element standard spectrum for the mixed spectra at ten points in Table 2 are shown in Fig. 7 and Fig. 8. Fig. 7 shows that the intersections of calculated content of H using an oxide standard spectrum and the theoretical content are almost all located on the diagonal line, which means the calculated value is almost the same as the theoretical one. The content of H obtained from the pure element standard spectrum is much lower than the theoretical one, and the higher the formation porosity, the larger the difference between the calculated value and the theoretical value. These show that the accuracy of H content calculated from the oxide standard spectrum is relatively high. In Fig. 8, although the content of Ca obtained from an oxide standard spectrum is slightly higher than the theoretical 0.24 0.24 0.26 0.28 0.30 0.32 Fig. 8 Weight percentage content of Ca based on limestone model 4.3 Mixed formation of sandstone and limestone with different porosities To further compare the spectrum analysis results in complex formations with the above two types of standard spectra, we suppose that there is a reservoir with the lithology of limestone and sandstone with porosity from 2% to 10% corresponding to nine points, and the formation pores are C H, C Si and C Ca in Table 3 represent the weight percentages of H, Si and Ca respectively.

467 Point Table 3 Mixed formation model of sandstone and limestone C Si C Ca C H Porosity % matrix g/cm 3 1 0.046 0.320 0.004 10 2.433 0.4 0.3 Ca 2 0.092 0.285 0.004 9 2.454 3 38 0.250 0.003 8 2.475 4 84 0.214 0.003 7 2.496 5 0.231 78 0.002 6 2.517 6 0.278 42 0.002 5 2.539 7 0.326 06 0.002 4 2.560 8 0.374 0.070 0.001 3 2.581 0.2 0.0 9 0.422 0.033 0.001 2 2.602 Fig. 9 and Fig. 10 show the analysis results with oxide standard spectrum and pure element standard spectrum for the mixed spectra at nine points in Table 3. As shown in Fig. 9, when the content of Si is higher than 0.2, the calculated value using pure element standard spectrum is higher than the theoretical one, and the higher the content of Si, the higher the deviation degree from the theoretical value. When the content of Si is less than 0.2, the content of Si obtained from a pure element standard spectrum is lower than the theoretical value, and even negative. However, the intersections of the calculated content of H using oxide standard spectra and the theoretical content are almost all distributed along the diagonal line, which means the calculated value is extremely close to the model composition. Fig. 10 shows information similar to that of Fig. 9. 1.0 0.8 0.6 0.4 0.2 0.0-0.2-0.4 Si -0.4-0.2 0.0 0.2 0.4 0.6 0.8 1.0 Fig. 9 Weight percentage of Si based on mixed formation The same can be seen from the analysis results of mixed formation spectra that the computation accuracy of element content using the oxide standard spectrum is better than that with a pure element standard spectrum. Fig. 10 Weight percentage of Ca based on mixed formation 5 Conclusions The standard spectra of formation elements can be calculated using either pure elements or their oxides. Compared with the standard spectra using a pure element, the standard spectra using the oxide have more prominent characteristic energy peaks. It can be seen from the analysis results of different formation models that the element content calculated with oxide standard spectrum is close to the theoretical value. Therefore, element standard spectra should be calculated from the oxides. Acknowledgements This paper is financially supported by National Natural Science Foundation of China (Grant No. 41074101) and Science Foundation of China University of Petroleum (Beijing) (No. KYJJ2012-05-12). References 0.0 0.2 0.3 0.4 Al- Ghorabie F H H. Development of a computer code using the EGS4 Monte Carlo simulation system to evaluate the response of a NaI(Tl) detector to photons with energies below 300 kev. Applied Radiation and Isotopes. 2006. 64(1): 85-92 Cha pman S, Colson J L, Everett B, et al. The emergence of geochemical well logging. The Technical Review. 1987. 35(2): 27-35 Gra u J A and Schweitzer J S. Elemental concentrations from thermal neutron capture gamma-ray spectra in geological formations. Nuclear Geophysics. 1989. 3(1): 1-9 Gra u J A, Schweitzer J S and Hertzog R C. Statistical uncertainties of elemental concentrations extracted from neutron induced gamma-ray measurements. IEEE Transactions on Nuclear Science. 1990. 37(6): 2175-2178 Hen driks P H G M, Maucec M and De Meijer R J. MCNP modeling Applied Radiation and Isotopes. 2002. 57(3): 449-457 Her tzog R, Colson L, Seeman O, et al. Geochemical logging with spectrometry tools. SPE Formation Evaluation. 1989. 4(2): 153-162 (SPE16792) Hua ng L J. The Principle of Radioactive Logging. Beijing: Petroleum

468 Industry Press. 1985. appendix (in Chinese) Ngu yen H V, Campbell J M, Couchell G P, et al. Programs in C for and unfolding of continuous gamma spectra. Computer Physics Communications. 1996. 93(2-3): 303-321 Pan g J F and Li M. Analytical methods with neutron-gamma ray spectrometry from formation elements. Journal of Isotopes. 2006. 19(2): 70-74 (in Chinese) Pan g J F, Li M and Yan Z G. New analyzing method & software and applications of inelastic spectra from C/O spectrometry logs. Nuclear Physics Review. 2005. 22(1): 67-71 (in Chinese) Pei L C and Zhang X Z. The Monte Carlo Method and Its Application in Particle Transport. Beijing: Science Press. 1980. 5-50 (in Chinese) Shi H X, Chen B X, Li T Z, et al. Precise Monte Carlo simulation of gamma-ray response functions for a NaI(Tl) detector. Applied Radiation and Isotopes. 2002. 57(4): 517-524 Xiang D and Guo L Y. Monte Carlo simulation of gamma spectra. Journal of Mathematical Medicine. 2006. 19(3): 229-231 (in Chinese) (Edited by Hao Jie)