RAYTECH USA, Inc. 90C Randall Avenue, Woodlyn, PA USA Tel Fax Instruction Manual

Similar documents
Oberebenestrasse Bremgarten Switzerland Tel Fax

VIBRATION METER. Instruction Manual.

Field Pro Operation and Installation Manual

WeatherHub2 Quick Start Guide

SkyScan EWS-PRO - Manual -

Lamp and Control Panel (Lamp Panel)

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Acceleration/Velocity/Displacement VIBRATION METER

566/568. Infrared Thermometers. Getting Started

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Small Absolute Pressure Sensor

QUANTUM CONCEPT. Swimming User s Manual

Operating Instructions for Digital Manometer. Model: MAN-SD

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

O P E R A T I N G M A N U A L

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Small Gage Pressure Sensor

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Drive electronics pq12

Small, Gauge Pressure Sensor

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Instruction Manual HI Refractometer for Invert Sugar Measurements

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Mini Environmental Quality Meter

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

INSTRUCTION MANUAL FOR MM10 Relay

PiCUS Calliper Version 3

User Manual VX4750 Function Generator Module

473 Dew Point Hygrometer

OEM Silicon Pressure Die

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Dual laser + type K thermometer INFRARED THERMOMETER

Watercooled RF Power Pot Capacitors External Cooling System

SPECIFICATION SHEET : FHS2-UNV-36L

HEAVY DUTY SWING-OUT VALVE

LDR Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

Integrated Suppression Module

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

Microcare LCD Solar MPPT User Documentation

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

HEAVY DUTY SWING-OUT VALVE

CR10TCR THERMOCOUPLE REFERENCE

INSTRUCTION MANUAL DTH Fax: (503)

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

Installation guide 862 MIT / MIR

product manual H-3220A Benkelman Beam

CR10XTCR THERMOCOUPLE REFERENCE

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Circular Motion and Centripetal Force

Training Guide. Coastal Environmental Systems, Inc.

DRIFTER PLOW-IN-A-BOX

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Rotary Motion Sensor

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

SM98A Harsh Media Backside Absolute Pressure Series

/2" Heavy Duty Swing-Out

Medium Pressure Sensor Analog Output

IR/Thermistor Pen. Instruction Manual

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

Commercial Generator Parts Catalog. PROTEC Series

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

473 Dew Point Hygrometer

Avery Dennison LV-0700 Series Retroreflective Validation Decal Film Issued: July 2013

FIELD GUIDE FOR HORUS SCOPES

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

CR10XTCR THERMOCOUPLE REFERENCE

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

WEATHERPAK TRx Training Guide

MODEL H3022 MAGNETIC BASE / DIAL INDICATOR / CALIPER COMBO OWNER'S MANUAL

ZOOM STEREO MICROSCOPE

Instruction Manual SEFRAM Thermal Camera

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

OWNER S MANUAL. Daniels Wing Plow. Operating Instructions Illustrated Parts List

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

Transcription:

RAYTECH USA, Inc. 90C Randall Avenue, Woodlyn, PA 19094 USA Tel. 610 833 3016 Fax. 610 833 3018 Instruction Manual 50 Amp / 3 Channel Winding Resistance Meter Model: WR50-13 Preliminary Instruction Manual Ver. 1.02

RAYTECH USA, Inc. T A B L E O F C O N T E N T S Section Page(s) Table of Contents 2 Safety Precautions 1 0 3 Uncrating Procedure 2 0 4 Technical Specifications 3 0 5 Introduction 4 0 6 Advantages & Features 6 System Details 5 0 7 Limitations of Testing 7 Discharging Transformer Windings 7 Demagnitization 7 Front Panel Description 6 0 8 Power, USB Ports, Serial Port, Safety Switch 8 Printer, Temperature inputs, External, Warning lights 9 Test connection inputs, ground terminal, vents 10 Operation 7 0 11 Getting started 7 1 12 Range Tab 13 Mode Tab 14 Temp. Corr. Tab 15 During Test / Demagnitization 16 General Menu 8 0 17 Service Mode, About 18 Update Firmware 19 Setting the Clock 20 Length Correction 20 Alternative Caption 21 Temperature measurements (Option TP-01) 9 0 22 Archive / Stored Results 10 0 23 Basic Instructions 11 0 24 Quick Test 11 1 24 Trouble Shooting 12 0 25 Error Messages 12 1 26 Warranty 13 0 27 Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 2

SAFETY PRECAUTIONS! 1 0 The following safety precautions must be observed during all phases of operation, service, and repair of this instrument. By purchasing this equipment the purchaser assumes all liability for the operation and use of this equipment. The intended use of the instrument, its design and manufacture, is to be conducted within the precautions or other specific warnings located within this manual. Failure to comply with these precautions and other specific warnings violates safety standards of design, manufacture, and intended use. Raytech Switzerland assumes no liability for the operation and use of this equipment. SAFE OPERATION Only qualified knowledgeable persons should be permitted or attempt to operate this test equipment. All test personnel should fully familiarize themselves with the correct application and operation of this and all test equipment prior to operation. Persons directly and indirectly engaged in the operation of this test equipment should keep clear of all high voltage apparatus while conducting tests and measurements. BEFORE APPLYING POWER Read this manual carefully before operating the system. The WR50-13 is line operated. The system operates from a wide range power input from 90 to 264 Vac 50/60Hz. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes. KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove instrument covers. Component replacement and internal repairs must be made by qualified service personnel. Do not replace components with power cable connected. To avoid injuries, always disconnect power, discharge circuits, and remove external voltage sources before touching components. DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to the Raytech USA service department for service to ensure proper operation and that safety features are maintained. Instruments which appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. TEST WARNING * DO NOT USE ON LIVE CIRCUITS * Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 3

UNCRATING PROCEDURE: 2 0 Unpack your new WR50-13 and check to see that you have the following standard items: WR50-13 Current Jumper Jumper Leads Lead #1 Lead #2 Cable Carry Case Channel 1 Channel 2 Channel 3 Ground with shoulder strap Leads Leads Leads Lead Manual Power Stylus Ext. Extra Cord USB Paper Key If any of the above items are missing or damaged contact your local representative or Raytech USA immediately. Custom test lead sets, other than shown, may be purchased with the WR50-13. * Note: The WR50-13 Field case is a waterproof design that incorporates an automatic pressure relief valve that will adjust to various atmospheric changes; i.e... Airplane Travel, High altitudes, etc... The valve is designed to be water resistant. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 4

TECHNICAL SPECIFICATIONS 3 0 MODEL: WR50-13 SIZE: L: 521 mm (20.5 ) W: 432 mm (17 ) H: 216 mm (8.5 ) WEIGHT: 18.8 kg (41.5 lbs.) INPUT POWER: 100 to 250 Vac (1.5kW max.), 50/60 Hz, Automatic ranging OUTPUT VOLTAGE: 0 to 50V DC TEST CURRENT: User Selectable: 50. 0.1 Ampere PANEL DISPLAY: Color LCD with back lighting and touch screen FRONT PANEL: Sealed anodized INTERFACE: 9 Pin RS232 Serial / 2 USB 1.1 Type A and B MEMORY STORAGE: Stores up to 10000 complete test results RESISTANCE RANGE: 0.00 µω to 100.0 kω INDUCTANCE RANGE: 0 Henry to 1500 Henry MEASUREMENT PARAMETERS: Current Range Measuring Range Accuracy Resolution 50 30 A 0.00 µω...1.6 Ω ± 0.1% Rdg ± 0.05 µω 5 Digits or 0.05 µω 30 15 A 0.0 µω...3.3 Ω ± 0.1% Rdg ± 0.1 µω 5 Digits or 0.1 µω 15 8 A 0.0000 µω 6.3 Ω ± 0.1% Rdg ± 0.2 µω 5 Digits or 0.2 µω 8 3 A 0.0000 µω..16.7 Ω ± 0.1% Rdg ± 0.5 µω 5 Digits or 0.5 µω 3 1 A 0.000 µω 47.2 Ω ± 0.1% Rdg ± 1 µω 5 Digits or 1 µω 1 0.7 A 0.000 µω.71.4 Ω ± 0.1% Rdg ± 2 µω 5 Digits or 2 µω 0.7 0.3 A 0.000 µω..167 Ω ± 0.1% Rdg ± 5 µω 5 Digits or 5 µω 0.3A 0.1 A 0.00 µω 500 Ω ± 0.1% Rdg ± 10 µω 5 Digits or 10 µω 100 ma 25 ma 0.00 µω...2 kω ± 0.1% Rdg ± 20 µω 5 Digits or 20 µω 25 ma 2 kω...10 kω ± 0.1% Rdg ± 200 µω 5 Digits or 200 µω 25 ma 10 kω...100 kω ± 0.8% Rdg ± 20 Ω 5 Digits or 20 Ω TEMPERATURE : Operating: -10 C to 60 C Storage: -20 C to 70 C CABLE SET / ACCESSORIES Current & Potential lead set - 10 meters, 2 Jumper leads -10 Meters ea, Safety ground lead (10 meters), power cord, Instruction Manual, Stylus, extra paper, external USB drive and cable set carry case. FEATURES: Charges inductive loads up to 1500 Henry Heavy duty protection circuitry Simple touch screen operation Data exchange with an external USB-Key 3 Temperature channels High power DC Supply (50A/50V ) DC Current adjustable for resistance values from 0.0 µω to 100 kω Fastest Discharge unit on market ( more then 10 times faster ) Discharge Indicator visible and audible indicator for discharge status Demagnetizing Circuit Warning Lamp to show Transformer under test Emergency stop push button immediately turns off power and starts discharging Data transfer to internal Printer Data Storage of up to 10000 measurements Mounted in rugged case for field testing 5 Year standard warranty OPTIONS: Part No - 2021N-26001: External temperature probe (TP01) Part No - AHRT 01: Heat Run Test * Specifications are subject to change at anytime. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 5

INTRODUCTION 4 0 Raytech Digital Winding Resistance meter, WR50-13, was designed for high degree of accuracy for the measurement of very low resistance of inductive loads. This technology was then packed into a portable test system for use by apparatus manufacturers, rebuild shops, and electrical maintenance crews. Ease of use: This intelligent system has an easy to use operation screen, which allows quick selection of the current level to be measured. Use the Touchscreen to change or activate an item. Impressive Accuracy: The WR50-13 is a high precision, fully automatic, multi-microprocessor based system. This system is designed for highly accurate readings on-site with laboratory precision. Unique Measuring Technique: This newly designed technique of measurement incorporates a high precision measurement circuit,a unique power source and the fastest discharge unit on market. Extensive filtering and high precision standards are used within the test system. The system is capable of precision measurements to 50 A. Operation: The WR50-13 applies a preset current level, selected by the User. The 50V power source quickly charges the load. The results of the test are then displayed within a few seconds automatically. The results are reported on the easy to read color LC display and can be stored or printed. Compact Design: The WR50-13 is one of the most lightweight systems available that comes complete with its own rugged waterproof Fieldcase. Simple Maintenance: There is No maintenance required. This is due to the utilization of high precision components in the design. Advanced Protection: Upon powering on, the system initializes itself with a self-calibrating, circuit checking sequence. If any problems are detected during this initialization period, or during operation, the operator is immediately notified. The system constantly monitors the condition when turned on. The WR50-13 has extensive protection built in to the circuitry. This is one of the many reasons we can extend our warranty to 5 years. Advantages & Features: Highest accuracy and Precision of any high current test system Automatic measurements of Low Resistance from 0.0µΩ...100kΩ Microprocessor based system with internal storage for over 10000 test results Printing and Storage of test results while the test system is measuring Complete automatic calibration system and system diagnostics Standard USB 2.0 & RS232 (serial) Interface Pure filtered DC Power source for the highest accuracy readings Automatic, high efficiency cooling system to dissipate internal temperatures Automatic shut off for over-temperature condition Automatic Demagnetization circuit built-in Panel mounted Emergency Stop Switch Wide input power source range Lightweight and Portable, less than 19 kg (42 Lbs.) 5 Year standard warranty Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 6

SYSTEM DETAILS: 5 0 System Check: The instrument is Line operated. The system is designed to be used with voltage power sources (mains power) between 90-264 Vac 50/60Hz. The system performs a self check each time it is powered on. The User should always visually inspect all connectors, cables and devices to be measured to avoid any safety issues. Limitations of Winding Resistance Testing: In general,there are no limitations on testing low or high inductive windings of transformers. The test system is specially designed to test all transformer windings. Low Resistance Testing: The WR50-13 utilizes the 4 wire measuring technique. The points where the potential leads are connected determine the resistance reading. The test set employs a very simple principle of Ohm s law: R=V/I R = Resistance, V = Voltage, I = Current Discharging Transformer Windings: The WR50-13, as well as all of the WR50 series, are specialized systems designed to measure transformer windings. These systems are equipped with heavy duty discharge circuits that are very unique in the market! The internal discharge circuit dissipates the stored energy in the transformer windings with Constant Power Discharge Circuit which is unique to all transformer winding test systems. That is the reason why Raytech systems can discharge transformers more then 10 times faster then any other system on the market. If a cable happens to fall off during test, the system will STILL discharge the test object safely with the automatic Constant Power Discharge Circuit The Potential Test Leads are part of the safety circuit and have the ability to discharge a transformer in the case where a current lead may become detached. DO NOT USE A SMALLER GAUGE POTENTIAL (VOLTAGE) CABLES THEN ORIGINAL CABLES SUPPLIED! Demagnetization: Upon completion of a transformer winding resistance test the core material may become magnetized due to the Direct Current that had been applied to the Windings. This magnetization of the core must be removed prior to energizing the transformer for use. The WR50-13 incorporates a demagnetization circuit which will automatically evaluate the magnitude of the magnetization of the core and reduce it to a safe level. This process is performed quickly and safely. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 7

FRONT PANEL DESCRIPTION: 6 0 Power Emergency OFF Power cord connection On/Off switch Accepts 90...264 Vac 50/60 Hz Press to stop Turn Clockwise to release Interfaces: USB 2.0 Port: 1 Host and 1 Device Serial Port: RS232 Bi-directional, Female 9 pin connector Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 8

FRONT PANEL DESCRIPTION: (cont.) 6 0 Panel Mount Printer: * The printer uses thermal heat transfer technology. Therefore, there are no ink cartridges required or printer heads. Special thermal paper is required for printer to operate properly. * This panel mount printer allows the user to print out stored results. * The single button on the printer is for Form-Feed. * To tear paper, pull paper towards the front of the instrument against the serrated cutting edge. Temperature Probe connection: External Flashing light: Three 2 pin Connections for optional external temperature probes ( TP01 ) Connection for an external Flashing Light or Beeper to indicate a Dangerous condition. Working contact (230Vac 2A) between Pin 3 + 4 Danger / Safe Condition Display: Shows that Current is flowing. Shows that you bought Shows that test Object is Do not remove any Cable! the right Instrument. in a Safe condition. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 9

FRONT PANEL DESCRIPTION: (cont.) 6 0 Test Connections: Ground Terminal The ground connection is located towards the back panel of the raised portion of the faceplate. It is spring loaded and threaded. Use the supplied ground wire to snap the spade under the ground terminal. Do so by un-threading the green part. Or you may use a 4mm banana plug into the top of this connector. Vents These vents pull in the air. This is the exhaust vent. *Please make sure there are no obstructions blocking these vents. Damage to the system may occur. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 10

OPERATION: 7 0 WARNINGS! BEFORE OPERATING THIS OR ANY OTHER TEST EQUIPMENT READ ALL SAFETY WARNINGS AND UNDERSTAND THEM FULLY. OPERATION: This section describes a typical, step by step, operation of the WR50-13. Open the protection lid of the case and attach the test leads, power cord, and safety ground to the test set. The Two (2) connections on the Front plate; +Current & -Current are the current leads. The six (6) connections on the Front plate; +Channel 1 & -Channel 1, +Channel 2 & -Channel 2, +Channel 3 & -Channel 3 are the Potential or Voltage leads. These connectors are color coded. Blue for Channel 1, Green for Channel 2, Brown for channel 3. By connecting a test specimen to the Current leads and applying the potential leads across the specimen, the resistance readings will be determined. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 11

GETTING STARTED: 7 1 Turn on the Power switch, located at the power input connector, to the I position. The Initial screen will appear. The Instrument will also make the initial calibration. After a few seconds the main screen will appear (or similar):: * For a quick Go To a certain tab/feature, perform the following: - To access the General tab, touch the display next to the ohm (Ω) symbol. - To access the Mode tab, touch the display next to the Mode title, beneath the Status bar. - To access the Range tab, touch the display next to the Range title, beneath the Status bar. - To access the Temp. Corr. tab, touch the display marked Temp. Correction. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 12

GETTING STARTED: (cont.) 7 1 Range Tab The WR50-13 incorporates a touch-screen display for all input parameters. All Parameters are initiated from the Set up screen: General, Mode, Range, Temp. Corr., and Colors. First, select the Current Range level to be used for the measurement by touching Set up and then Range. The following screen (or similar) appears: Select the Current level required by tapping on that range ( For example: 10A ). Immediately after selection of the required current range, the system will revert to the test screen. Start the measurement by just touching the Start Button. At the start of a test an single audible beep will be heard as a reminder that the test system is about to charge the inductive windings. Operators should be careful not to remove any cables while the test system is measuring. * You may also customize the current output range by pressing Set on the bottom right hand side of the screen. The following screen (or similar) appears: Press the left or right arrows to adjust the current range. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 13

GETTING STARTED: (cont.) 7 1 Mode Tab: When the Setup button is pressed from the test screen, area includes the test settings, such as single, continuous, and interval. The Quality Assistant is used for adjusting the instrument s readings for when the current flow is stable. You may select Auto Print Results if you desire to print the results after each test. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 14

GETTING STARTED: (cont.) 7 1 Temp. Corr. Tab: The WR50-13 can correct the measured values regarding the temperature. To activate this feature, press Setup and then Temp. Corr. Tab. The following screen will appear: In this example, the measured object is copper and will be corrected to 25 Degrees Celsius based on the temperature on Temperature channel 1. If you do not have a Raytech Temperature probe (TP-01), activate the Ext box and fill in the temperature you measure with your other temperature probe or measuring device. The correction follows the formula: Rs = Rm[(Ts+Tk)/(Tm+Tk)] where Rs is resistance at desired temperature, Ts Rm is measured resistance Ts is desired reference temperature Tm is the temperature at which resistance was/is measured Tk is 234.5 for copper, 225 for aluminum (aluminum may be as high as 240) If you are used to a correction with alpha25 you can calculate the Tk by the formula: Tk=(1/alpha25)-25 If you are using another Tk then the standards for cooper or aluminum, activate the box User defined and input the Tk in the box below. When Temperature correction feature is activated, the main screen appears as follows: The T in the box at each measuring channel shows that the displayed resistance value is corrected (in this example to 25 Degrees using Tk of cooper and referring to Temperature probe 1). * In case the T in the box is red, there is no temperature probe connected. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 15

GETTING STARTED: (cont.) 7 1 After the system parameters are set and the safety ground cable and test leads are connected a resistance test can be run. The system is very easy operate. Simply: Select (Touch) Start to start a test. When results are displayed and are stable press Store. To end the test press Stop. then wait for Safe Status display. During the measurement you may see the following (or similar): The operator may press Store at anytime to store a measurement. Multiple measurements can be made while the instrument is running. These data will be stored as a complete record. The current continues to flow and the system will measure until the Measurement is halted by touching Stop. Demagnetization: After completion of the winding resistance test, the operator may initiate the Automatic Demagnetization Circuit. No removal or changing of the test leads are necessary or required. The system is designed to operate the demagnetization circuit with the cables attached to the transformer exactly as they were attached when performing the winding resistance test. Simply press the Demag button on the test screen. Select the correct current and press start. To select approproiate current, choose a current range above the test current. If testing at 30A, select 40A, etc. The test system will then automatically detect the magnitude of stored energy (if any) and demagnetize the transformer core. Note: Maximum demagnetization can be achieved by demagnetizing the transformer from the High side winding. For example from H1 to H2 winding. DO NOT TOUCH, MOVE OR MANIPULATE THE MEASURING CABLES BEFORE YOU HEAR TWO BEEPS AND THE DISPLAY AND LAMPS SHOW A SAFE CONDITION! Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 16

GENERAL MENU 8 0 To access the Setup Menu, select (touch) Setup and then General. The above image is for reference only and may differ from the actual display. * License Manager Shows status of system license and allows user to add the heat run software code. * Firmware Update To update or change the built in Firmware, see page 19. * Language Allows user to select proper language; Deutsch, English, French, or Turkish. * Clock Settings Setting the clock. See Page 20. * About Check the version of the installed Firmware. See page 18. * USB Printer Allows user to assign an external printer to one of the USB Type A Ports. * Service Mode Not for public use. See page 18. * Length Correction For use when testing long lengths of cable. See page 20 for more details. * Alternative Caption Allows the user to change the name of Channel 1 or Channel 2 or Channel 3. See page 21 for more details. * Show Mouse Cursor Show or hide the Mouse Cursor. Useful when using an external mouse via one of the USB ports. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 17

GENERAL MENU: (cont.) 8 0 SERVICE MODE In the Setup Menu is a Service Mode. This Mode is for internal service use only and not accessible. A login code is required. Touch # to Exit. ABOUT You can easily check the Firmware Version installed on your WR50-13, as well as the serial number. In the general tab, touch Setup and then the About key. The above image is for reference only and may differ from the actual display. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 18

GENERAL MENU: (cont.) 8 0 UPDATE THE FIRMWARE You can easily check the Firmware Version installed on your WR50-13. In the Main Display touch Setup - and then the About key The above image is for reference only and may differ from the actual display. A newer Version may be available and can be found at this link: www.raytechusa.com Follow these simple steps to update the system s firmware: 1. Download this new version and store it to the external USB Key provided with the system. 2. Switch the WR50-13 on and plug the USB Key into the USB Port of the Instrument. 3. Select Firmware Update under the General tab in the Setup menu. Follow the on screen instructions. Below are examples of how the display might look: Select the Version you want to install and then press Install. Please wait until the system reboots or follow the on-screen instructions. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 19

GENERAL MENU: (cont.) 8 0 SETTING THE CLOCK To set the clock, go to the general tab and select (touch) the Setup and then the Clock Set the desired values by touching the Left, Right, or down arrows next to the related locations. By selecting (Touching) Set the Clock will be activated and set. *The above image is for reference only and may differ from the actual display. LENGTH CORRECTION OPTION This feature allows the user to set the length of cable that is under test. Along with the R (resistance) correction for a particular length of cable. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 20

GENERAL MENU: (cont.) 8 0 ALTERNATIVE CAPTION The user may change or re-name the titles for channel 1, 2, or 3. Using the provided Stylus or the tip of your finger, double tap the caption, such as R1 or Channel 1 located in the white box. The following screen will appear allowing the user to modify the name of a particular channel. When a desired name is set, press close. Repeat the above steps for changing the name or title of the remaining channels. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 21

TEMPERATURE MEASUREMENTS 9 0 The system allows up to three (3) temperature probes to be used with the system for the purpose of recording temperatures. Optional Part Number: TP-01, can be purchased for this purpose. Recording the temperature of the device under test is highly recommended due to the characteristics of the increase of resistance of a metallic object as its temperature increases. There are temperature compensation tables for Copper and Aluminum available to calculate the conversion factor to a known reference temperature. The WR50-13 is a very accurate and precise test system. To take full advantage of this high accuracy, the temperature of the device under test should be recorded. The TP-01 temperature probe is mounted to a flexible extension cable that plugs into the front panel of the WR50-13. This option enables the User to record the ambient temperature and/or the actual temperature of the device under test. The WR50-13 will automatically sense when the optional temperature probes, TP-01, are connected to it. The temperature will be displayed on the instrument screen during a test and will appear when a printed report is requested. The temperature, as well as the test results, can be saved into memory. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 22

ARCHIVE: 10 0 To access the Archive (Memory locations), touch Results. The next screen will show the stored records. The options at the top of this screen allow the user to Print the stored results, Delete all or one of the stored results, Open the header or details page, Export all or one of the results to an external USB drive, and perform a Heat Run Test (HRT). Double-Touch the Test record to proceed to the Details page. This page shows the details of the test, such as Test Time, Resistance readings of channel 1, 2, 3, Temperature (when using external temperature probe, and the actual Current. By touching the arrows on the bottom left or right, you will see all the stored results of that selected measurement. An empty field (ie.. T2) indicates that no temperature probe was connected. Pressing Header at the bottom of the screen will give you the following screen: This screen shows the actual settings that were preset for a particular result. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 23

BASIC INSTRUCTION: 11 0 WARNINGS! BEFORE OPERATING THIS OR ANY OTHER TEST EQUIPMENT READ ALL SAFETY WARNINGS AND UNDERSTAND THEM FULLY. WARNINGS! BEFORE USING THE BASIC OPERATING INSTRUCTIONS THE OPERATOR SHOULD BE COMPLETELY FAMILIAR WITH THE TEST SYSTEM AND THIS TYPE OF TESTING. QUICK TEST: 11 1 This section outlines the basic measurement instruction, step by step, for the WR50-13. These are basic instructions, simplified, for the trained and qualified operator. 1. Connect the test leads (2 Current and 2 or 4 or 6 Potential) to an un-energized device to be measured. 2. Connect the Safety Ground on the back panel to known good Earth Ground. 3. Turn on the Test system. 4. Select the Current Range. 5. Select (Touch) Start to start the test. 6. When results are displayed and are stable press Store. 7. To end the test press Stop. 8. Wait for Safe Status display. Notes: Store: The operator may press Store at anytime to store a measurement. Multiple measurements can be made while the instrument is running. These data will be stored as a complete record. The current continues to flow and the system will measure until the Measurement is halted by touching Stop. Demagnetization: After completion of the winding resistance test, the operator may initiate the Demagnetization process. No removal or changing of the test leads are necessary or required. The system is designed to operate the demagnetization circuit with the cables attached to the transformer exactly as they were attached when performing the winding resistance test. Simply press the Demag button on the test screen. Select the correct current and press start. To select appropriate current, choose a current range above the test current. If testing at 100A, select 100A, etc. The test system will then automatically detect the magnitude of stored energy (if any) and demagnetize the transformer core. DO NOT TOUCH, MOVE OR MANIPULATE THE MEASURING CABLES BEFORE YOU HEAR TWO BEEPS AND THE DISPLAY AND LAMPS SHOW A SAFE CONDITION! Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 24

Troubleshooting GENERAL 12 0 At power on, the WR50-13 internal calibration and check sequence is performed. Upon completion of the check sequence the test set will proceed to the Main Screen. Should there be any problem with the test set an error message will appear. SYSTEM DOES NOT DISPLAY ANYTHING: 1. Check the display for any Initialization. 2. Check the fuse. The fuse is located in the Power switch / plug connector. SYSTEM POWERS ON BUT THE DISPLAY FADES OUT OR BLINKS: 1. Check the input power line for faults. 2. If an extension cord is being used, check the size and condition of the cord. An extension cord should not exceed 25 feet long and should be at least #12 wire minimum. TEST CURRENT CANNOT BE TURNED ON. 1. Is the Emergency stop switch pushed in? Turn to release it. 2. Is the system connected in an excessive interference area? WARNING Rx TOO HIGH or +++.+ IS DISPLAYED. 1. A warning message, Rx Too High or +++.+ will be displayed if the resistance being measured is too high for the range selected. The +++.+ is displayed when no input is measured on the +P & - P terminals. 2. The current leads total resistance has exceeded the current capability of the instrument. Reduce the current lead length or increase the wire gauge of the current lead used. ERRATIC OR ERRONEOUS READINGS Possible causes 1. Test lead damaged or not connected. 2. Poor test lead connection. 3. Poor supply power. Check extension cords, plugs and cables carefully. 4. Test set attached to a Live load or high interference load. The WR50-13 is designed to be trouble free. If problems or questions do arise, please contact our service support group, 888 4 THE SPY. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 25

ERROR MESSAGES 12 1 The emergency switch is activated In this condition it is impossible to start a measurement. Exiting this message screen by touching OK without releasing the emergency switch, The system will revert to a pretest or main screen similar to the following screen: Because the emergency switch is still depressed, you are not able to start a new measurement. All other features of the system ( storing, printing ) are still active. The above images are for reference only and may differ from the actual display. ------------------------------------------------------------------------------------------------------------------- Attempt to store results to the USB-key without any device key plugged to the WR50-13 Plug the USB-key in and try again. The following will appear: Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 26

WARRANTY 13 0 RAYTECH USA, Inc. warrants to the original purchaser of any new WR50-13, 50 Amp / 3 Channel Winding Resistance Test Set, that it will be free from defects in material and workmanship under normal use and service for a period of 2 years from the original date of shipment. An additional 3 year extended warranty is provided, at no cost to the end user, for the products covered under this warranty if the products are returned on each calendar year from the original date of shipment, prepaid, to Raytech USA, for system evaluation. Failure to do so will void the additional extended warranty. The obligation of RAYTECH USA, Inc. under this warranty is limited, in its exclusive option, to repair, replace, or issue credit for parts or materials which prove to be defective, and is subject to purchaser's compliance with the RAYTECH USA, Inc. warranty claim procedure as set forth within this manual. This warranty covers only those parts and/or material deemed to be defective resulting from manufacturer s workmanship. The liability of RAYTECH USA, Inc. shall be limited to the repair, replacement, or issuance of credit for parts deemed defective within the meaning of this warranty. Costs for labor or other expenses that may have occurred incidental to the inspection, repair, replacement, or issuance of credit for such parts and/or materials shall be the sole responsibility of purchaser. This warranty shall not apply to any accessories, parts, or materials not manufactured or supplied by RAYTECH USA, Inc. Equipment must be returned prepaid with a Return Material Authorization (RMA) to: RAYTECH USA, Inc. or RAYTECH GmbH 90 C Randall Avenue Oberebenstrasse 11 Woodlyn, PA 19094 CH-5620 Bremgarten USA Switzerland Tel. 1 610 833 3016 Tel. + 41 56 640 0670 Fax. 1 610 833 3018 Fax. + 41 56 640 0674 www.raytechusa.com www.raytech.ch LIMITATION OF WARRANTY The foregoing warranty shall not apply to defects resulting from improper and unauthorized modifications or misuse and abuse of the product, negligence, alteration, modification, faulty installation by the customer, customer s agents or employees. Attempted or actual dismantling, disassembling, service or repair by any person, firm, or corporation not specifically authorized in writing by RAYTECH USA, Inc. Defects caused by or due to handling by carrier, or incurred during shipment, trans-shipment, or other move. Inadequate maintenance by the customer, second source supplied software or interfacing, operation outside the environmental limits, or improper site preparation. Exclusive remedies provided herein are the customer s sole and exclusive remedies. RAYTECH USA, Inc. shall not be liable for any damages resulting from the use of this equipment whether direct, indirect, special, incidental, or consequential damages, or whether based on contract, tort, or any other legal theory. NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent. 27