Mason Technology Ltd

Similar documents
Mason Technology Ltd

Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

Saolta University Health Care Group Galway University Hospital

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Document No: TR 12 Issue No: 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation to ISO/IEC 17025:2005

R SANAS Page 1 of 7

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Forensic Science Ireland

The Fundamentals of Moisture Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

g/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

CALIBRATION CERTIFICATE # 503

Test Report EN (2008)

Certificate of Accreditation

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

Certificate of Accreditation

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

CERTIFICATE OF ACCREDITATION

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Part 5: Total stations

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

Accuracy Calibration Certificate

ESTA governance Quality Assurance System for Seed Treatment and Treated Seed

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Certificate of Accreditation

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

CERTIFICATE OF CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

ISO INTERNATIONAL STANDARD. Surface chemical analysis X-ray photoelectron spectroscopy Repeatability and constancy of intensity scale

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration, traceability, uncertainty and comparing measurement results. Workshop 16 March 2015 VSL, Delft The Netherlands

CERTIFICATE OF ACCREDITATION

IMPORTANT FEATURES OF ESTIMATION & INTERPRETATION OF MEASUREMENT UNCERTAINTY. B. Bhattacharya, K. Ramani, P.H. Bhave

Certificate of Accreditation

Withdrawn at December 31, Guideline DKD-R 5-7. Calibration of Climatic Chambers DEUTSCHER KALIBRIERDIENST

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

Demonstrate knowledge of a track warrant control (TWC) system

Manual stack emissions monitoring Performance Standard for laboratories carrying out analysis of samples

SAMPLE. Accuracy Calibration Certificate. Mettler Toledo 1900 Polaris Parkway Contact: Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC WI v.1.

REQUEST FOR QUOTATION (RFQ) FOR PROCUREMENT OF THERMO HYGROMETER -UNDP GLOBAL FUND

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Method Validation and Accreditation

Certificate of Accreditation

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

CERTIFICATE OF CALIBRATION

Certificate of Accreditation

This document is a preview generated by EVS

Chilled Mirror Hygrometry

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

Annex I to Resolution 6.2/2 (Cg-XVI) Approved Text to replace Chapter B.4 of WMO Technical Regulations (WMO-No. 49), Vol. I

Calibration Traceability Guidelines

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Calibration of Temperature Block Calibrators

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

ANALYSIS CERTIFICATE OF

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Loadcell Calibration - Evaluation of Uncertainties

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

ISO Water quality Measurement of polonium 210 activity concentration in water by alpha spectrometry

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

Chapter X: Radiation Safety Audit Program

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

QUALITY ASSURANCE AND QUALITY CONTROL IN CHEMICAL AND PHYSICAL ANALYSIS

OIML R 141 RECOMMENDATION. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

SECTION H CHEMICAL WEAPONS DESTRUCTION FACILITIES REQUIRED UNDER PARTS IV(A) OF THE VERIFICATION ANNEX OF THE CONVENTION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Transcription:

Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule bearing the Registration Number detailed above, in compliance with the International Standard ISO/IEC 17025:2005 2 nd Edition General Requirements for the Competence of Testing and Calibration Laboratories (This Certificate should only be read in conjunction with the annexed Schedule of ) Date of award of accreditation: 09:05:2002 Date of last renewal of accreditation: 28:11:2016 Expiry date of this certificate of accreditation: 28:11:2021 This shall remain in force until further notice subject to continuing compliance with INAB accreditation criteria, ISO/IEC 17025 and any further requirements specified by the Irish National Board. Manager: Dr Adrienne Duff Chairperson: Ms Ita Kinahan Issued on 28 November 2016 Organisations are subject to annual surveillance and are re-assessed every five years. The renewal date on this Certificate confirms the latest date of renewal of accreditation. To confirm the validity of this Certificate, please contact the Irish National Board. INAB is a signatory of the European co-operation for (EA) Testing Multilateral Agreement (MLA) and the International Laboratory Cooperation (ILAC) Mutual Recognition Arrangement. Edition 30, 23/02/2017 043C Page 1 of 10

Schedule of (Annex to Certificate) MASON TECHNOLOGY LTD. Balance, Temperature and Speed Measuring Devices Calibration Laboratory Initial Date : 26-July-1994 Postal Address: 228 South Circular Road, Dublin 8 Acorn Business Campus, Mahon Industrial Estate, Co. Cork (Site-office) Telephone: +353 (0)1 4534422 Fax: +353 (0)1 4154492 E-mail: mnolan@masontec.ie Contact Name: Ms Mandy Nolan Facilities: Public calibration service Edition 30, 23/02/2017 043C Page 2 of 10

Schedule of THE IRISH NATIONAL ACCREDITATION BOARD (INAB) is the Irish body for the accreditation of organisations including laboratories. Laboratory accreditation is available to testing and calibration facilities operated by manufacturing organisations, government departments, educational institutions and commercial testing/calibration services. Indeed, any organisation involved in testing, measurement or calibration in any area of technology can seek accreditation for the work it is undertaking. Each accredited laboratory has been assessed by skilled specialist assessors and found to meet criteria which are in compliance with ISO/IEC 17025 or ISO/IEC 15189 (medical laboratories). Frequent audits, together with periodic inter-laboratory test programmes, ensure that these standards of operation are maintained. Calibration Categories: Category A: Permanent calibration laboratory where the laboratory is erected on a fixed location for a period expected to be greater than three years. Category B: Category C: Category D: Site calibration that is performed by staff sent out on site by a permanent laboratory that is accredited by the Irish National Board. Site calibration that is performed in a site/mobile laboratory or by staff sent out by such a laboratory, the operation of which is the responsibility of a permanent laboratory accredited by the Irish National Board. Site calibration that is performed on site by individuals and organisations that do not have a permanent calibration laboratory. Calibration may be performed using (a) (b) (c) (d) portable test equipment a site laboratory a mobile laboratory or equipment from a mobile or site laboratory Standard Specification or Calibration Procedure Used: The standard specification or calibration procedure that is accredited is the issue that is current on the date of the most recent visit, unless otherwise stated. Glossary of Terms Facilities: Public calibration service: Conditionally available for public calibration: Normally not available for public calibration: Commercial operations which actively seek work from others. Established for another primary purpose but, more commonly than not, is available for outside work. Unavailable for public calibration more often than not. Laboratory users wishing to obtain assurance that calibration results are reliable and carried out to the Irish National Board criteria should insist on receiving an accredited calibration certificate. Users should contact the laboratory directly to ensure that this schedule of accreditation is current. INAB will on request verify the status and scope. Edition 30, 23/02/2017 043C Page 3 of 10

Permanent Laboratory: Category A Mass Calibration Laboratory (Nominal temperature for calibration work: 20±2 C for F class weights) (Nominal temperature for calibration work : 22.5±3.5 C for M Class weights) measurement capability expressed as an uncertainty * 120 Masses Range-Nominal value Documented in-house (mg) methods:.01 Industrial mass 25000g ± 25.0 SOP MS1/ MS2/ MS3/MS4 standards 20000g ± 20.0 10000g ± 10.0 M Class weights 5000g ± 8.3 1mg to 25kg 2000g ± 2.0 1000g ±1.0 F Class weights 500g ±0.50 1mg to 20kg 200g ±0.20 100g ±0.12 50g ±0.06 20g ±0.050 10g ±0.040 5g ±0.030 2g ±0.024 1g ±0.020 0.5g ±0.016 0.2g ±0.012 * Notes: 1. Intermediate values can be calibrated with an uncertainty interpolated from the next higher and lower values in the table above. 2. Calibration can be given in other units as required. 3. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 4. measurement capability expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 30, 23/02/2017 043C Page 4 of 10

Permanent Laboratory: Category A Mass Calibration Laboratory (Nominal temperature for calibration work: 20±2 C for F class weights) (Nominal temperature for calibration work : 22.5 ±3.5 C for M Class weights) measurement capability expressed as an uncertainty * 120 Masses Documented in-house Range-Nominal value (mg) methods:.01 Industrial mass SOP MS1/MS2/MS3/MS4 standards 0.1g ±0.010 M Class weights 0.05g ±0.008 1mg to 25kg 0.02g ±0.006 0.01g ±0.005 F Class weights 0.005g ±0.004 1mg to 20kg 0.002g ±0.004 0.001g ±0.0048 * Notes: 1. Intermediate values can be calibrated with an uncertainty interpolated from the next higher and lower values in the table above. 2. Calibration can be given in other units as required. 3. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 4. measurement capability expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 30, 23/02/2017 043C Page 5 of 10

Permanent Laboratory: Category A, B Balance Calibration Laboratory (Nominal temperature for calibration work: 20±2 C) measurement capability expressed as an uncertainty * 121 Calibration of Weighing Documented in-house Devices method: SOP W1, SOP W2, SOP W3.01 Precision laboratory balances 1 mg - 5 g ±0.02mg OIML Class E2 Weights 5 g - 22 g ±0.026mg.02 Industrial balances 22 g - 100 g ±0.051mg OIML Class F1 Weights 100 g - 600 g ±0.14mg.03 Industrial weighing appliances 600 g - 1000 g 1000 g - 8100 g ±1.0mg ±1.4mg 20 g 600 g ±0.6mg 600 g - 1000 g ±2.5mg 1 kg - 5 kg ±6mg 5 kg - 20 kg ±10mg 20 kg - 60 kg ±65mg * Notes: 1. Intermediate values can be calibrated with an uncertainty interpolated from the next higher and lower values in the table above. 2. Calibration can be given in other units as required. 3. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 4. measurement capability expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 30, 23/02/2017 043C Page 6 of 10

Speed Measuring Device Calibration Laboratory (Nominal temperature for calibration work: 20±15 C) Measurement Capability expressed As an uncertainty (see note) 151 Speed measuring Documented in-house devices method: SOP SMD1, SOP SMD2.99 Other devices 0 to 599.9 rpm ± 2.2 rpm - including centrifuges 599.9 to 9,999.9 rpm ± 2.9 rpm 10,000 to 50,000 rpm ± 13 rpm Elapsed time ± 0.51 seconds 1 second to 1 hour * Notes: 1. Intermediate values can be calibrated with an uncertainty interpolated from the next higher and lower values in the table above. 2. Calibration can be given in other units as required. 3. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 4. measurement capability expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 30, 23/02/2017 043C Page 7 of 10

Temperature Calibration Laboratory (Nominal temperature for calibration work: 20±10 C) measurement capability expressed as an uncertainty (see note) 501 Calibration of temperature measuring equipment.41 Digital temperature indicator system Thermocouples Permanent -86 o C to 0 o C 0.22 o C + Unit Resolution SOP TS1 0 o C to +125 o C 0.21 o C + Unit Resolution +125 o C to +300 o C 0.24 o C + Unit Resolution Site -80 o C to -30 o C 0.59 o C + Unit Resolution -30 o C to +140 o C 0.30 o C + Unit Resolution +140 o C to +250 o C 0.39 o C + Unit Resolution All other probes Permanent -86 o C to 0 o C 0.084 o C + Unit Resolution 0 o C to +125 o C 0.048 o C + Unit Resolution +125 o C to +300 o C 0.115 o C + Unit Resolution Site -80 o C to -30 o C 0.55 o C + Unit Resolution -30 o C to +140 o C 0.22 o C + Unit Resolution +140 o C to +250 o C 0.33 o C + Unit Resolution Edition 30, 23/02/2017 043C Page 8 of 10

Temperature Calibration Laboratory (Nominal temperature for calibration work: 20±15 C) measurement capability expressed as an uncertainty (see note) 510 Temperature control Documented in-house enclosures methods:.01 Ovens, refrigerators, -80 o C to 0 o C (WS) ±0.48 o C SOP T1, SOP T2 freezers and baths 0 o C to + 140 o C (WS) ±0.18 o C +140 o C to +300 o C (WS) ±0.48 o C -80 0 C to +75 0 C (Veriteq) ±0.32 0 C.02 Incubators -10 o C to +100 o C (WS) ±0.18 o C SOP T3-10 0 C to 75 0 C (Veriteq) ±0.32 0 C.03 Autoclaves & sterilising Autoclaves: SOP T6 ovens +80 o C to +140 o C ±0.18 o C Including time interval 5 mins. to 24 hrs. time ± 1.6 sec s per 1 interval hour Sterilising Ovens: SOP T1 +80 o C to + 140 o C ±0.18 o C 5 mins. to 24 hrs. time ± 1.6 sec s per 1 interval hour.04 Industrial Freezers -80 o C to 0 o C (WS) ±0.48 0 C SOP T1-80 0 C to 0 0 C (Veriteq) ±0.32 0 C Edition 30, 23/02/2017 043C Page 9 of 10

Temperature Calibration Laboratory (Nominal temperature for calibration work: 20±15 C) Measurement Capability expressed As an uncertainty (see note) 560 Hygrometry.30 Testing of environmental chambers: Stability Cabinets 10 o C to 60 o C ± 0.32 o C SOP T7 Climatic Cabinets 20% RH to 85% RH ± 3.3% Environment Cabinets * Notes: 1. Intermediate values can be calibrated with an uncertainty interpolated from the next higher and lower values in the table above. 2. Calibration can be given in other units as required. 3. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 4. measurement capability expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 30, 23/02/2017 043C Page 10 of 10