Preliminary Evaluation of Molecularly Imprinted Polymer Synthesized with Dopamine Hydrochloride as a Template

Similar documents
Electronic Supplementary Information. The selective response of templated polymer for the cationic drug

Dual Use of a Chemical Auxiliary: Molecularly Imprinted Polymers for the Selective Recovery of Products from Biocatalytic Reaction Mixtures

Recognition and Absorption of the Water-soluble X-ray Contrast Medium Iodixanol using Molecularly Imprinted Polymers for Biomedical Applications

Molecularly imprinted polymers

Int. Res J Pharm. App Sci., 2013; 3(5):19-25 ISSN:

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Clickable molecularly imprinted nanoparticles

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Hongyuan Yan and Kyung Ho Row *

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

[ Care and Use Manual ]

Evaluation of New Selective Molecularly Imprinted Polymers for the Extraction of Resveratrol from Polygonum Cuspidatum

Liquid Chromatography

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

637. Thiamethoxam. HPLC method

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Solid-Phase Extraction of Catechin Compounds From Green Tea by Catechin Molecular Imprinted Polymers

MOLECULARLY IMPRINTED SOLID PHASE EXTRACTION FOR TRACE ANALYSIS OF DIAZINON IN DRINKING WATER

Synthesis and Study of Guest-Rebinding of MIP Based on MAA Prepared using Theophylline Template

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

Open Column Chromatography, GC, TLC, and HPLC

Flow injection chemiluminescence determination of epinephrine using epinephrine-imprinted polymer as recognition material

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Selection of Imprinted Nanoparticles by Affinity Chromatography

Defense Technical Information Center Compilation Part Notice

Defense Technical Information Center Compilation Part Notice

Determination of trace anions in concentrated hydrofluoric acid

Mara Soares da Silva, Raquel Viveiros, Vasco Bonifácio, Ana Aguiar-Ricardo, Teresa Casimiro*

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

Chapter content. Reference

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Chromatography. Gas Chromatography

High Performance Liquid Chromatography

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Ondansetron Hydrochloride Tablets

Methanolysis of Poly(ethylene terephthalate) in Supercritical Phase

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

High Performance Liquid Chromatography

Column Liquid Chromatography Experiment Adapted for Use in Secondary Schools

A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil Hydrochloride by Validated HPLC Method

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Computational and experimental studies on oxalic acid imprinted polymer

Shodex TM ODP2 HP series columns

Instrumental Chemical Analysis

The importance of functional monomer dimerization in molecular imprinting process

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Supporting Information for:

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

LUMEFANTRINUM LUMEFANTRINE

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

LC Technical Information

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Deep eutectic solvents as novel extraction media for phenolic. compounds from model oil

EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

Acclaim Mixed-Mode WCX-1

Yujuan Zhou, Kecheng Jie and Feihe Huang*

Journal of Chromatography A, 1117 (2006) Junjie Ou, Liang Kong, Chensong Pan, Xingye Su, Xiaoyuan Lei, Hanfa Zou

Experiment 1: Thin Layer Chromatography

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

Does Hydrophilic Polydopamine Coating Enhance Membrane Rejection of

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Determination of Caffeine by HPLC

Hints for Strong Ion Exchange Resins

Grafting of molecularly imprinted polymer on multiwalled carbon nanotube for highly selective and sensitive determination of Thymine

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Preparation and application of a molecularly imprinted polymer for determination of glibenclamide residues

High Pressure/Performance Liquid Chromatography (HPLC)

Validated HPLC Methods

Solid Phase Extraction Method Development Tips and Tricks

Macroporous molecularly imprinted monolithic polymer columns for protein recognition by liquid chromatography

A project report on SYNTHESIS AND CHARACTERISATION OF COPPER NANOPARTICLE-GRAPHENE COMPOSITE. Submitted by Arun Kumar Yelshetty Roll no 410 CY 5066

Biochemistry. Biochemical Techniques HPLC

Grafting Amino-acid Molecular Imprinted Polymer on Carbon Nanotube for Sensing

H 3 CO H 3 CO S CH 3

for Acclaim Mixed-Mode WCX-1


LIQUID CHROMATOGRAPHY

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Journal of Chromatography A, 1114 (2006)

ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY

Transcription:

Preliminary Evaluation of Molecularly Imprinted Polymer Synthesized with Dopamine Hydrochloride as a Template Piotr Luliński a, Dorota Maciejewska a, Magdalena Bamburowicz- Klimkowska b and Mirosław Szutowski b a Department of Organic Chemistry, Faculty of Pharmacy, Medical University of Warsaw, Banacha 1 Str., 02-097 Warsaw, Poland. Tel./Fax: +(4822) 5720643. E-mail: lulinski93@yahoo.com b Department of Toxicology, Faculty of Pharmacy, Medical University of Warsaw, Banacha 1 Str., 02-097 Warsaw, Poland. Tel./Fax: +(4822) 5720730. Abstract: A new easy approach to separation of dopamine hydrochloride is reported. The molecularly imprinted polymer (MIP) was used as the adsorbent material. The MIP was prepared employing dopamine hydrochloride as a template and methacrylic acid (MAA) with ethylene glycol dimethacrylate (EDMA) in co-polymerization process. Non-covalent prearrangement between dopamine hydrochloride and methacrylic acid in organic porogen prior to bulk polymerization was utilized. Preliminary chromatographic results showed that dopamine hydrochloride could be retained by the polymer and then eluted using optimized elution protocol. The interactions between template and monomers were proposed of the basis of semiempirical PM3 theoretical calculation. Keywords: Molecularly imprinted polymers, Dopamine hydrochloride, Solid Phase Extraction Introduction In our investigation related to selective enrichment and clean-up of the analytes containing catecholamines we found a new easy approach to separation of dopamine hydrochloride using molecularly imprinted polymer (MIP) as the adsorbent material. Molecular imprinting is a method for preparing polymers with desired and predetermined selectivity [1, 2]. First, the molecule for which selectivity is desired, called template or target molecule, is allowed to prearrange prior to polymerization in presence of monomer(s) with different functional group(s) that can interact with template. After polymerization the target molecules are removed, leaving well-defined three-dimentional cavities with spatially oriented functional groups in the highly cross-linked polymer network.

2 Covalent and/or non-covalent interactions can be employed in prepolymerization prearrangement between template and functional monomer. Covalent bonds are enough strong, but non-covalent interactions require use of functional monomers which form stable self-assembled complexes. In the later approach different interactions are involved to give prepolymerization complexes, such as hydrogen bonding, electrostatic and hydrophobic interactions. Traditionally, free radical bulk polymerization is utilized to prepare rigid monolith following grinding and sieving. Simplicity and availability are the major advantages of this method. Unfortunately, particles obtained during grinding and sieving process are heterogenous due to size, shape and internal morphology. Recently, several other methods were established to give more homogenous products like nanobeads or thin imprinted films, but they have some disadvantages, i.e. use of large amount of template [3]. Molecularly imprinted polymers are synthetic materials that have some important advantages over biomolecules i.e. thermal and chemical stability, sample load capacity, reproducibility, and low cost of preparation [4, 5]. MIPs have been applied in wide range of analytical techniques as adsorbents for solid phase extraction (SPE) [6, 7], chiral separation [8], artificial antibodies [9], biosensor components [10], and they are use as synthetic mediators [11]. The possibility of employing molecularly imprinted polymers for solid phase extraction has been evaluated in many papers. Increasing interest is observed in the application of molecularly imprinted solid phase extraction (MISPE) in pharmaceutical science, and lot of drugs was separated, e. g. local anesthetics [12], β 2 -antagonists [13], antibiotics [14]. We have found up to now only few reports concerned to separation of dopamine. Dopamine is an important neurotransmitter. Decrease of dopamine concentration in human brain leads to many serious diseases. Makote and Collinson [15] prepared dopamine templated nanoporous silica gel films. Results showed that obtained material is not selective and have an affinity for other catecholamines. Due to our best knowledge no one used noncovalent approach to prepared molecularly imprinted polymer capable to separation of dopamine hydrochloride. Experimental Materials and Instruments Dopamine hydrochloride, methacrylic acid, ethylene glycol dimethacrylate, and 2,2 - azobis(izobutyronitryl) were purchase from Fluka (Germany). Ammonium formate was

3 purchase from POCh Gliwice (Poland). Acetonitryle was from Riedel-de-Haën (The Netherlands), methanol and chloroform were from Chempur (Czech Rep.), aceton and glacial acetic acid were purchase from POCh Gliwice (Poland). All reagents were analytical grade or equivalent, and were used without further purification. Solid phase extraction was carried out on Bakerbond SPE glass column, 1 ml (J. T. Baker, The Netherlands). Chromatografic studies were performed using a Shimazu liquid chromatograph system with pump (LC-10 AT, Japan), spectrofluorimetric detector (RF 551, Japan), and 20 μl injector (Rheodyne 7725, Japan). Separation was carried out on a stainless steel column: 150 mm x 4,6 mm i. d., 5 μm (Discovery HS F5, Supelco, Bellefonte, PA, USA). The column was run at a flow rate: 1.0 ml/min (temp. 40 o C) using 0.05 M ammonium formate methanol (3:1 v/v) as a mobile phase, and the detector was set at λ EX = 280 nm and λ EM = 315. Preparation of Molecularly Imprinted Polymer Dopamine hydrochloride (0.095 g, 0.5 mmol), methacrylic acid (0.344 g, 4 mmol), ethylene glycol dimethacrylate (5.95 g, 30 mmol) and 2,2 -azobis(izobutyronitryle) (65 mg) were mixed in 12.5 ml of chloroform and the mixture was purged with nitrogen for polymerization at 60 o C for 24 h. The resulting monolith was ground with mortal and pestle and put into Soxhlet apparatus to extract template (6 cycles, methanol acetic acid, 1:1 v/v) followed by continuous wash to remove remains of unreactants and/or byproducts (6 cycles, acetonitrile). Then the polymer was wet-sieved into particles below 45 μm diameter (Retsch, Germany). Fine particles were removed by repeated decantation in acetone (10 x 5 min). The remain particles were put into column and washed with ammonium formate methanol till no template was found in the washing solution. Finally particles were dried under vacuum and used for following studies. The control polymer was synthesized and treated in the same way as corresponding imprinting polymer except that no target molecule was added and no extraction of template was performed. Molecularly Imprinted Solid Phase Extraction Protocol The polymer particles, 56.2 mg were dry packed into SPE columns. During the solid phase extraction protocol we prewashed the particles with 1 ml of water followed by conditioning with 2 ml of phosphorate buffered saline, ph 8. The column was loaded with 2 ml of 1 μg/ml solution of dopamine hydrochloride and washed with 1 ml of water. Elution

4 stages were performed using 0.5 ml of 0.05 M ammonium formate (3:1 v/v) in the ph range from 6 to 3. Results and Discussion Preparation of dopamine imprinted polymer was not easy task. Dopamine and its solution are unstable even in room temperature and when exposed to the light. Compound is available only as a stable hydrochloride salt. We have decided to prepare MIP in a single step by bulk polymerization at 60 o C with dopamine hydrochloride as a template. The several systems were tested, including different ratios between template and monomers (unpublished results). Here, we present results of most appropriate system for separation of dopamine hydrochloride containing methacrylic acid (MAA), ethylene glycol dimethacrylate (EDMA), and chloroform as a porogenic solvent. We also synthesized a control polymer following the same procedure but without dopamine hydrochloride. Methacrylic acid was extensively studied as a functional monomer and is widely used for various target molecules [16, 17]. It is well-known that this functional monomer shows strong non-specific interactions with templates [18]. On the basis of the PM3 calculation we evaluated the ability of dopamine cation and methacrylic acid to form two types of complexes, one with three molecules of monomer, named A (Fig. 1) and second one with six molecules, named B (Fig. 2). Fig. 1. Theoretical complex of A.

5 Fig. 2. Theoretical complex of B. The starting geometries of these complexes were generated by replacing optimized components in the same file. The energies of complexes A and B are smaller by -43.1 and -66.6 kcal/mol, respectively. Energies were calculated as: ΔE = ΔH complex nδh MAA ΔH dopamine cation. Apparently, both complexes represent favourable structures in solution. Both polymers, imprinted and blank, were employed for solid phase extraction of dopamine hydrochloride and then were evaluated by HPLC for their imprinting effects. Experiments were performed in duplicate. The polymers were tested using water as a washing solvent and ammonium formate methanol (3:1 v/v) as an eluent. It was also necessary to introduce gradient ph elution to improve recovery of dopamine hydrochloride. Table. Recovery of dopamine hydrochloride using ammonium formate methanol (3:1 v/v) as an eluent, eluted in gradient ph. Recovery (%) Fractions Control polymer Imprinted polymer Load (2 ml) 9.6 0 Water wash (1 ml) 2.2 0 Ammonium formate methanol (3:1) ph 6 elution (0.5 ml) 3.6 34.1 Ammonium formate methanol (3:1) ph 5 elution (0.5 ml) 5.3 26.5 Ammonium formate methanol (3:1) ph 4 elution (0.5 ml) 2.9 7.1 Ammonium formate methanol (3:1) ph 3 elution (0.5 ml) 2.3 13.1 Total recovery 25.9 80.8

6 Results show (Table) that dopamine hydrochloride was retained by the imprinted polymer through the load and washing steps. Total recovery from imprinted polymer was high compared to blank polymer. This result is probably related with high non-specific binding of methacrylic acid. It will be the aim of our further investigations. Conclusions These preliminary results show that appropriate MIP adsorbent was synthesized and optimal SPE protocol was performed. Further investigations are under way. Acknowledgement The authors would like to express their sincere thanks to Dr hab. Wojciech Fabianowski at Technical University of Warsaw (Poland) for valuable discussions and providing some necessary chemicals. References and Notes 1. Wulff, G., Sarhan, A., Angew. Chem. Int. Ed. Eng., 1972, 11, 341. 2. Wulff, G., Angew. Chem. Int. Ed. Eng., 1995, 34, 1812-1832. 3. Haupt, K., Analyst, 2001, 126, 747-756. 4. Svenson, J., Nicholls, I. A., Anal. Chim. Acta, 2001, 435, 19-24. 5. Xie, J., Chen, L., Li, C., Xu, X., J. Chrom. B, 2003, 788, 233-242. 6. Stevenson, D., Trends Anal. Chem., 1999, 18, 154-158. 7. Hennion, M.-C., J. Chrom. A, 1999, 856, 3-54. 8. Kempe, M., Mosbach, K., J. Chrom. A, 1995, 694, 3-13. 9. Ramström, O., Ye, L., Mosbach, K., Chem. Biol., 1996, 3, 471-477. 10. Yano, K., Isao, K., Trends Anal. Chem., 1999, 18, 199-204. 11. Alexander, C., Tetrahedron, 2003, 59, 2025-2057. 12. Andersson, L. I., Hardenborg, E., Sandberg-Ställ, M., Möller, K., Henriksson, J., Bramsby-Sjöström, I., Olson, L.-I., Abdel-Rehim, M., Anal. Chim. Acta, 2004, 526, 147-154.

7 13. Blomgren, A., Berggren, C., Holmberg, A., Larsson, F., Sellergren, B., Ensing, K., J. Chrom. A, 2002, 975, 157-164. 14. Lai, E. P. C., Wu, S. G., Anal. Chim. Acta, 2003, 481, 165-174. 15. Makote, R., Collinson, M. M., Chem. Commun., 1998, 425-426. 16. Wang, D., Hong, S., P., Row, K., H., Korean J. Chem. Eng., 2004, 21, 853-857. 17. Dong, X., Wang, W., Ma, S., Sun, H., Li, Y., Guo, J., J. Chrom. A, 2005, 1070, 125-130. 18. Meng, Z., Wang, J., Zhou, L., Wang, Q., Zhu, D., Anal. Sci., 1999, 15, 141-144.