Proposal: criteria for positive identification in LC-MS analysis

Similar documents
WADA Technical Document TD2003IDCR

WADA Technical Document TD2015IDCR

Multi-residue analysis of pesticides by GC-HRMS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

FUTURE CONFIRMATORY CRITERIA

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

DRD Trends in Portugal: Updates From Forensic Toxicology Services

MassHunter TOF/QTOF Users Meeting

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Automated and accurate component detection using reference mass spectra

GUIDELINES ON PERFORMANCE CRITERIA FOR METHODS OF ANALYSIS FOR THE DETERMINATION OF PESTICIDE RESIDUES IN FOOD AND FEED CXG Adopted in 2017.

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Choosing Fit-For-Purpose Food Safety Methods

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Signal, Noise, and Detection Limits in Mass Spectrometry

Theory and Practical Consequences.

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Application Note. Authors. Abstract. Introduction. Environmental

Agilent All Ions MS/MS

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

TUTORIAL EXERCISES WITH ANSWERS

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Glyphosate in all its forms

This document is a preview generated by EVS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

MassHunter Software Overview

The Theory of HPLC. Quantitative and Qualitative HPLC

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

To control the consistency and quality

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Highly Sensitive and Rugged GC/MS/MS Tool

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

How to screen and identify unexpected and unwanted compounds in food

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

3.1.1 The method can detect, identify, and potentially measure the amount of (quantify) an analyte(s):

Introduction to E&Ls 1

The new Water Screening PCDL

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Official Journal of the European Union REGULATIONS

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

VALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

VOTING DRAFT STANDARD

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Making the Transition From a Quantitation Lab to a QuantInformation Lab

Trends Trends in Analytical Chemistry, Vol. 24, No. 7, 2005

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Agilent ESI and APCI sources: for polar to non-polar compounds

LC-HRMS: Challenges for Routine Implementation

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Cerno Application Note Extending the Limits of Mass Spectrometry

José Benito Quintana, PhD University of Santiago de Compostela Castellón Training Course

Development and application of methodology for designer drugs

Link to article, DOI: /j.chemosphere Publication date: Document Version Peer reviewed version. Link back to DTU Orbit

Validation Report 18

Die Nadel im Heuhaufen

Making Sense of Differences in LCMS Data: Integrated Tools

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

IDENTIFICATION AND QUANTIFICATION OF TRANSFORMATION PRODUCTS IN THE AQUATIC ENVIRONMENT BY HIGH RESOLUTION MASS SPECTROMETRY

CHEMISTRY Topic #3: Using Spectroscopy to Identify Molecules: Radicals and Mass Spectrometry (MS) Spring 2018 Dr.

Information Dependent Acquisition (IDA) 1

Regulatory and Alternative Analytical Procedures are defined as follows 2 :

Mass Spectrometry (MS)

Compounding insights Thermo Scientific Compound Discoverer Software

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Estimation of LOQ for the Analysis of Persistent Organic Pollutants, in particular PCDD/Fs and PCBs

High-Field Orbitrap Creating new possibilities

Transcription:

Proposal: criteria for positive identification in LC-MS analysis Lubertus Bijlsma, Maria Bronze, Emma Gracia Lor, Susana Simoes Any analytical methodology should comply with several quality requirements, in order to generate reliable data for accurate quantification and safe identification. Method validation is obviously required, and the application of realistic criteria based on the acquisition of several MS/MS transitions considering their specificity, or criteria based on mass measurement accuracy is also necessary. Thus, the accomplishment of retention time and ion intensity ratios when compared with the reference standard is mandatory for reliable identification of the compound. Quality procedures applied by researchers in other fields of investigation i.e. food safety, are used to set up the following proposal. Quantification. An analytical methodology needs to be fully validated to ensure the quality of the results. The performance of the methods should be validated in terms of linearity, LOQ, LOD, accuracy and precision. Validation should be performed prior to the analysis of samples at analyte concentrations close to the expected concentrations in real samples, since matrix effects may depend on the concentration of the analyte [1]. Confirmation of the identity. Confirmation of analyte identity is necessary to avoid reporting false positives and/or false negatives. Analytical chemists have to develop reliable methods that allow not only accurate quantification of targeted analytes but also, and even more importantly, their unequivocal identification. Ideally, confirmation of the identity should be objective and safe, not depending on the subjective interpretation of the analyst, so predefined, efficient confirmation rules are necessary. Low resolution (LR) MS/MS systems typically operate under SRM mode, where a precursor ion is selected in the first quadrupole, fragmented in the collision cell, and a specific product ion is selected using the second quadrupole. The selection of a specific SRM transition, avoiding the use of common losses (e.g. 1/6

H2O, CO2 and HCl), is important in order to prevent the reporting of false positives or false negatives. However, even with this approach, there are some probabilities that other compounds, not related to the analyte, can share the same transition. Therefore, a second SRM transition is often monitored and the presence of a compound is only considered to be confirmed if both transitions produce chromatographic peaks with retention times corresponding to that of the investigated analyte in pure standard. In addition, the ratio of the intensities of the two recorded SRM transitions must be similar to that obtained for the reference standard. Thus, in order to correctly identify a compound the relative ion intensities between both recorded transitions (q/q ratio) need to comply. Slightly different tolerances are proposed for the analysis of wastewater and biological samples as we selected the criteria usually applied in each research field. For wastewater analysis, the ion ratio should coincide with the ion ratio obtained from the reference standard, with maximum permitted tolerance between 20 and 50% (Table 1) [1, 2]. These criteria were proposed by SCORE (Sewage Analysis CORe group Europe) [3, 4]. Table 1: Maximum permitted tolerances for relative ion intensities (wastewater analysis). Relative Abundance (% of base peak) q/q ratio value Tolerance (%) > 50% 0.5-1 20 > 20 to 50% 0.5-0.2 25 > 10 to 20% 0.2-0.1 30 10% < 0.1 50 2/6

For biological samples, the relative intensities of any of the ions shall not differ by more than the amount in Table 2 from the relative intensities of the same ions acquired from the reference material analyzed contemporaneously. These criteria are proposed by the WADA (World Anti-Doping Agencia) [5]. Table 2 - Maximum tolerance windows for relative ion intensities to ensure appropriate confidence in identification (biological samples). Relative Abundance Maximum Tolerance Window (% of base peak) > 50% ±10% (absolute) 25% to 50% ± 20% (relative) 5% to <25% ±5% (absolute) <5% ± 50% (relative) In addition, the maximal accepted deviation in retention time is two percent or ± 0.1 min between the compound in sample and the reference standard. Alternatively, the laboratory may choose to use relative retention time (RRT) as an acceptance criterion, where the retention time of the peak of interest is measured relative to a chromatographic reference compound (internal standard). The RRT shall not differ by more than ±1% from that of the reference material analyzed contemporaneously. The signal-to-noise of the least intense diagnostic ion shall be greater than three-to-one (3:1). Identification criteria according to the recommendations of the International Standard for Laboratories - technical document - TD2010IDCR from the international organization WADA [5]. One of the issues that still remains without broad consensus is the criteria applied for confident identification/confirmation when using high resolution MS. Accurate-mass measurements give more confidence for a reliable identification than nominal mass data, and this factor is recognized in several guidelines, which, for example, give more identification points to HRMS ions than LRMS ions [1]. It is widely accepted that at least two accurate-mass ions are required for a confident identification with HRMS. However, two main issues need to be considered: 1) what is the acceptable mass error? 2) what is the maximum deviation acceptable in the ion ratio? Moreover, another parameter helpful in the process is 3/6

the isotopic distribution, especially when abundant isotope ions such as chlorine, sulphur, or bromine are present. Several situations might occur that lead to different degrees of confidence in identification. For example, Schymanski et al. [6] propose up to 5 levels of confidence in a non-target analysis. These levels range from only exact mass to unequivocal molecular formula, and then tentative candidate(s) followed by probable structure to a fully confirmed structure with a reference standard. Figure 1 summarizes the key parameters in the detection and identification of a compound with HRMS. As shown in this figure, different scenarios might occur as a function on the information provided, and on the availability of reference standard. Screening with HRMS, key parameters Retention time (Rt) Accurate masses Mass errors Isotope pattern (Cl, Br ) Standard available Standard unavailable Detection Option 1 One ion (Q) Rt agreement Mass error < 5 ppm Option 2 Two ions (Q and q) Rt agreement Mass error > 5 ppm Identification Two ions (Q and q) Rt agreement Q mass error < 5 ppm q mass error < 5 ppm Isotope pattern Tentative identification Expected ion (Q), mass error < 5 ppm) Compatible isotope pattern (Cl, Br...) One or more fragment ions (q), - in agreement with data reported - compatible with the chemical structure of the candidate (mass error < 5 ppm) Identification required with reference standard Figure 1. Detection and identification criteria in screening of illicit drugs with HRMS [4]. 4/6

When a reference standard is available, compounds can be detected or identified. Detection is considered satisfactory when the most-abundant ion (Q), commonly the (de)protonated molecule, is found at the expected tr (± 0.1 min,) and mass error < 5 ppm [7]. Another likely situation for detection is to find two representative ions (i.e., the most-abundant ion (Q) and a fragment/adduct ions(q) at the expected tr), but with mass errors between 5-20 ppm. The latter situation seems to occur when the signal intensity is low (favored at low analyte concentrations). In that case, an additional effort is recommended to investigate more accuratemass ions and/or repeat sample injection. Identification is based on the presence of at least two representative ions (Q, q) at the expected tr with mass errors < 5 ppm. Additionally, q/q ratios should fit with those for reference standards within tolerance limits [7]. Identification under these conditions is highly reliable and can be considered as the ideal situation. When the reference standard is not available, a tentative identification can be made when an expected ion with mass error < 5 ppm is observed, together with its characteristic isotopic pattern. Subsequently, the fragment ions should be evaluated by comparing the data with, e.g., data reported in the literature or justified by the accurate-mass fragments taking into account the structure of the molecule. However, for structure confirmation, injection of the reference standard is eventually required. 5/6

References: 1. European Commission, E.: Decision 2002/657/EC, implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. (2002). 2. SANCO/12495/2011: Method validation and quality control procedures for pesticide residues analysis in food and feed. (2011). 3. S. Castiglioni, L. Bijlsma, A. Covaci, E. Emke, F. Hernández, M. Reid, C. Ort, K.V. Thomas, A.L.N. van Nuijs, P. de Voogt, E. Zuccato. Evaluation of uncertainties associated with the determination of community drug use through the measurement of sewage biomarkers. Environmental Science and Technology, 47, (2013) 1452-1460 4. F. Hernández, S. Castiglioni, A. Covaci, P. de Voogt, E. Emke, B. Kasprzyk-Hordern, C. Ort, M. Reid, J.V. Sancho, K. V. Thomas, A.L.N. van Nuijs, E. Zuccato, L. Bijlsma. Mass spectrometric strategies for the investigation of biomarkers of illicit drug use in wastewater. Mass Spectrometry Reviews (2016) DOI 10.1002/mas.21525 5. WADA World Anti-Doping Agency. International Standard for Laboratories. Identification criteria for qualitative assays TD2010IDCR 6. E.L. Schymanski, J. Jeon, R. Gulde, K. Fenner, M. Ru, H.P. Singer, J. Hollender. Identifying Small Molecules via High Resolution Mass Spectrometry: Communicating Confidence. Environmental Science and Technology 48, (2014) 2097 2098. 7. SANTE/11945: Guidance document on analytical quality control and method validation procedures for pesticide residues analysis in food and feed. (2015). 6/6