Login -the operator screen should be in view when you first sit down at the spectrometer console:

Similar documents
Chemistry Department

NMR Predictor. Introduction

Determining C-H Connectivity: ghmqc and ghmbc (VnmrJ-2.2D Version: For use with the new Software)

How to perform 2D NMR Experiments on the Varian/Agilent VNMRS 500 when using the Chempack interface

Operation of the Bruker 400 JB Stothers NMR Facility Department of Chemistry Western University

NMR Data workup using NUTS

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Jasco V-670 absorption spectrometer

2: SIMPLE HARMONIC MOTION

Chem 1 Kinetics. Objectives. Concepts

North Carolina State University Department of Chemistry Varian NMR Training Manual

HMQC HSQC and HMBC. Gradient HMQC, HMBC on the Bruker400 and 500

Exercises for Windows

2: SIMPLE HARMONIC MOTION

General Chemistry Lab Molecular Modeling

CHARTING THE HEAVENS USING A VIRTUAL PLANETARIUM

Band-Selective Homonuclear 2D Correlation Experiments

Zeeman Effect Physics 481

BCMB/CHEM 8190 Lab Exercise Using Maple for NMR Data Processing and Pulse Sequence Design March 2012

Kinetics of Crystal Violet Bleaching

ISIS/Draw "Quick Start"

Atomic Spectra HISTORY AND THEORY

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Experiment 4: Equilibrium Thermodynamics of a Keto-Enol Tautomerism Reaction

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #5: NMR Spectroscopy

Experiment 10. Zeeman Effect. Introduction. Zeeman Effect Physics 244

Example: Identification

H-C one-bond correlations: HSQC Preliminaries.

Simulation of Second Order Spectra Using SpinWorks. CHEM/BCMB 8190 Biomolecular NMR UGA, Spring, 2005

Chem 310, Organic Chemistry Lab Molecular Modeling Using Macromodel

ON SITE SYSTEMS Chemical Safety Assistant

Computational Chemistry Lab Module: Conformational Analysis of Alkanes

Preparing a PDB File

LAB 2 - ONE DIMENSIONAL MOTION

H-C one-bond correlations: HSQC Preliminaries.

Carbon and Heteronuclear NMR on the Bruker

Calculating Bond Enthalpies of the Hydrides

How to Make or Plot a Graph or Chart in Excel

BASIC NMR HANDBOOK Written by M. A. Eastman Copyright 1997, 2001, 2013, 2015, 2018

Mnova Software for Analyzing Reaction Monitoring NMR Spectra

Lewis Structures and Molecular Shapes

Wikipedia - Stellar classification:

Chemistry 14CL. Worksheet for the Molecular Modeling Workshop. (Revised FULL Version 2012 J.W. Pang) (Modified A. A. Russell)

Introduction to Astronomy Laboratory Exercise #1. Intro to the Sky

X-Nucleus NMR: 31 P and 19 F

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Pulsar. Delivering NMR to your benchtop

APPENDIX 1 Version of 8/24/05 11:01 AM Simulation of H-NMR without a structure*:

Experiment P14: Collision Impulse & Momentum (Force Sensor, Motion Sensor)

Comparing whole genomes

Figure 2.1 The Inclined Plane

You w i ll f ol l ow these st eps : Before opening files, the S c e n e panel is active.

Chapter 1: NMR Coupling Constants

Description of the ED library Basic Atoms

Collecting the data. A.- F. Miller 2012 DQF- COSY Demo 1

Electric Fields and Equipotentials

Project 3: Molecular Orbital Calculations of Diatomic Molecules. This project is worth 30 points and is due on Wednesday, May 2, 2018.

mylab: Chemical Safety Module Last Updated: January 19, 2018

Introduction to Hartree-Fock calculations in Spartan

POC via CHEMnetBASE for Identifying Unknowns

3 Charged Particle Motion in a Magnetic Field

LAB 4: FORCE AND MOTION

IncuCyte ZOOM NeuroTrack Fluorescent Processing

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

SkyGlobe Planetarium

How many states. Record high temperature

Assignment #0 Using Stellarium

Purdue-UAB Botanicals Center for Age- Related Disease

Pendulum Swing. Student Investigation Part 1. Introduction. Equipment. Collecting the data

Molecular Modeling and Conformational Analysis with PC Spartan

How to Create a Substance Answer Set

SeeSAR 7.1 Beginners Guide. June 2017

The Bohr Atom. PHYS 1301 F98 Prof. T.E. Coan Last edit: 6 Aug 98. Introduction

1H 1D-NOE Difference Spectra and Spin-Saturation Transfer Experiments on the GN500

Cerno Application Note Extending the Limits of Mass Spectrometry

Instruction to search natural compounds on CH-NMR-NP

2D NMR: HMBC Assignments and Publishing NMR Data Using MNova

H-NMR Interpretation 83 Chem 355 Jasperse 1H-NMR

NMR Assignments using NMRView II: Sequential Assignments

Space Objects. Section. When you finish this section, you should understand the following:

Experiment 0 ~ Introduction to Statistics and Excel Tutorial. Introduction to Statistics, Error and Measurement

Kinematics Lab. 1 Introduction. 2 Equipment. 3 Procedures

Assignment 1: Molecular Mechanics (PART 1 25 points)

DP Physics Torque Simulation

Lab 1 Uniform Motion - Graphing and Analyzing Motion

I. Introduction. II. An Introduction to Starry Night NAME: ORBITAL MOTION

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

EXPERIMENT : Work and Energy. Topics of investigation: The relation between force and acceleration

Structural Analysis of an Unknown Compound and Determination of its pk a by NMR Spectroscopy

iworx Sample Lab Experiment GB-2: Membrane Permeability

NMR PRAKTIKUM. Data processing Data acquisition... 17

Non Uniform Sampling in Routine 2D Correlation Experiments

Nuclear Magnetic Resonance

DETERMINATION OF THE DECOMPOSITION PRODUCTS OF CALCIUM OXALATE USING THERMAL GRAVIMETRY AND INFRARED SPECTROMETRY

Determining Chemical Structures with NMR Spectroscopy the ADEQUATEAD Experiment

Gravity: How fast do objects fall? Student Advanced Version

Hour Examination # 4

The fastest compact NMR spectrometer. spectrometer has superb sensitivity and the performance to provide useful results immediately.

Instructions for Using Spartan 14

Nuclear Magnetic Resonance (NMR) Spectroscopy Introduction:

Transcription:

Lab #2 1D 1 H Double Resonance (Selective Decoupling) operation of the 400 MHz instrument using automated sample insertion (robot) and automated locking and shimming collection of 1D 1 H spectra retrieving data, peak picking, peak integration, plotting selective decoupling and spectral analysis Login -the operator screen should be in view when you first sit down at the spectrometer console: chem6190 -from the list of operators (pull-down menu), select chem6190 -there is no password for this account -click OK 1D 1 H double-resonance lab CHEM 4190/6190/8189 1

Sample slot selection -if the tray panel is not present, click the O located above and to the left of the black spectral display window to display the tray panel 1D 1 H double-resonance lab CHEM 4190/6190/8189 2

-the tray panel represents the sample tray located on top of the white platform next to the magnet -the X in the upper left of the sample tray will toggle the display back to the black spectral display window -the numbered circles on the tray panel correspond to sample slots in the sample tray -sample slots that appear in color on the tray panel are NOT available for use -also, sample slot 50 is never available for use (this slot is reserved for a standard sample) -sample slots that appear gray on the tray panel may be available for use, but this must be confirmed (see below) -you also can click on this arrow which will pop up a small window that tells you what sample currently is in the magnet 1D 1 H double-resonance lab CHEM 4190/6190/8189 3

-click the switch to #50 button at the top of the screen -if nothing happens, this means that any of the gray slots can be used -if there is a sample in the magnet already, the robot will take it out and replace it with sample 50. At this point, all gray slots are now available for use (the robot is slow, so be patient) -choose one of the available (gray) slots. You must confirm that this slot is empty by checking the sample tray 1D 1 H double-resonance lab CHEM 4190/6190/8189 4

Sample placement -hold the sample tube near the middle of the tube and in a vertical position -push the tube through the hole on the large end of a sample spinner turbine -NEVER push on the top of the tube -the bottom of the tube should be pushed slightly through the bottom (small) end of the spinner turbine -set the tube/spinner assembly in the black sample depth gauge in the sample tray -push the tube (by its sides, NOT from the top) down until it stops -the tube is now properly positioned in the spinner turbine -now you can place your tube/spinner assembly in one of the open slots (on the sample tray, the slot number is to the right of the slot/hole) Experiment selection -you can select from among the experiment tabs the one corresponding to the experiment that you will be acquiring -in our case, we will select std 1D -click Proton -this will load the appropriate parameters for collecting a simple 1D 1 H experiment 1D 1 H double-resonance lab CHEM 4190/6190/8189 5

-in window below, new sample and Proton will appear (these will be colored yellow, indicating that the sample has not yet been submitted, and the experiment has not begun) -on the tray panel click on the appropriate slot (an empty one that you have chosen) -it will get a multicolored highlight once selected 1D 1 H double-resonance lab CHEM 4190/6190/8189 6

-click the start tab, and the study option -in the Sample field, enter a descriptive sample name -no capital letters or spaces, no special characters other than dash (-) and underscore (_) -for instance, chem6190-1d1h-090306 -the notebook, page, and comments fields can be left blank 1D 1 H double-resonance lab CHEM 4190/6190/8189 7

Setting parameters and submitting the sample -do not change the Temp (temperature setting), or the Spin setting, or the Lock setting -for solvent, select CDCl3 (deuterated chloroform) -click Submit to Day Queue -wait.the robot is slow -the slot in the tray panel corresponding to your sample will turn yellow -the robot will eventually get your sample and place it in the magnet 1D 1 H double-resonance lab CHEM 4190/6190/8189 8

Locking and shimming -in the automated mode, locking on the solvent and shimming (gradient shimming) are automated -the window at the bottom of the screen keeps you informed on the locking and shimming progress -another window at the bottom tells you that your sample has been submitted to the Day Queue 1D 1 H double-resonance lab CHEM 4190/6190/8189 9

Retrieving the data and displaying the spectrum -at the upper left, click the Home button, then double-click chem6190.. chem6190 1D 1 H double-resonance lab CHEM 4190/6190/8189 10

.then double-click on the filename that you gave to your data -the spectrum should appear (in the window previously occupied by the tray panel) -the two small blue arrow buttons ( ) at the lower left of the spectral window permit this window to be expanded (to fill most of the screen) and contracted 1D 1 H double-resonance lab CHEM 4190/6190/8189 11

Zooming in and out -to zoom in on a particular spectral region or peak of interest, place the arrow cursor at the left edge of this region and click the left mouse button (or drag the red cursor to the left side of the region of interest with the left mouse button), then move the arrow cursor to the right edge and click the right mouse button -then click the magnifying glass icon (on the vertical menu) to toggle between the full display and the selected region 1D 1 H double-resonance lab CHEM 4190/6190/8189 12

Adjusting scale -to adjust the scale/intensity, place the arrow cursor on a peak, hold down the middle mouse button, and move the mouse straight forward or backward (NOT sideways) Quick plotting -click on the Process tab and then the plot option -click Automatic plot page 1D 1 H double-resonance lab CHEM 4190/6190/8189 13

Chemical shift referencing -the 1 H chemical shifts should be referenced relative to TMS at 0.0 ppm -when CDCl 3 is used as the solvent, there is a small amount of residual CHCl 3 in the sample, and the 1 H signal of CHCl 3 resonates at exactly 7.27 ppm relative to TMS -thus, we will reference the spectrum relative to this CHCl 3 peak (we will force the computer to recognize the chemical shift of this peak as 7.27 ppm). -first, zoom in on the small signal at approximately 7.2 ppm -click the Process tab, then select default -set a red cursor (with the left mouse button) on the center of the CHCl 3 signal and click then find nearest line (under the Display options) -in the Set cursor to field, select ppm from the drop down menu, enter 7.27 in the box and hit return 1D 1 H double-resonance lab CHEM 4190/6190/8189 14

Peak picking -peak picking means determining what the chemical shifts are for the peaks in the spectrum -first, zoom in on the peaks in your spectrum (the region from about 0 to about 4 ppm) -first we need to set the intensity threshold (chemical shifts will be returned for all of the peaks with intensities above this threshold) -from the vertical menu at the left of the spectral display window, select the yellow threshold icon and move the yellow line up/down on the spectrum to the desired height -click the Process tab, then the Default option, then click the Find Peaks button (under Peak Picking) -the peak positions will be displayed on the screen -you can remove the displayed yellow lines and peak positions by selecting Process/Display and then clicking on Full under Screen Position 1D 1 H double-resonance lab CHEM 4190/6190/8189 15

-in order to print the peak positions (hardcopy), under Process/Plot, click Plot Spectrum, then Plot Spectrum Scale, then under Plot Peak Frequencies, select On Peaks. Then click Plot Page -if you want to return to a display without the peak positions, select Process/Display, and then click Full under Screen Position. If the ppm scale disappears, click the PPM option under Axis 1D 1 H double-resonance lab CHEM 4190/6190/8189 16

Integration -first, expand the display around the multiplet signal centered at about 3.43 ppm -on the vertical menu at the left is the integral icon/button -as you click on this button you toggle through the 3 modes: first is part integral, second is full integral, and third is no integral -select the part integral mode -when this is selected, two more integral buttons will appear below the first: the integral resets and the integral Lvl/Tlt -under Process/default, click clear integrals (under Integration options) -then click the integral resets button 1D 1 H double-resonance lab CHEM 4190/6190/8189 17

-then, place the cursor just to the left of the peak (at the baseline) and click (left mouse button) Then place the cursor just to the right of the peak and click (again, left mouse button). -you ll see that the green integral display changes to dashes except on the peak that you are integrating (which remains a solid green color) 1D 1 H double-resonance lab CHEM 4190/6190/8189 18

-expand around the next two signals in the spectrum (the two at approximately 2.2 and 2.0 ppm) -click the integral resets button -click on the right and left sides of each of these signals, as you have done for the previous signal -repeat this for the rest of the signals in the spectrum 1D 1 H double-resonance lab CHEM 4190/6190/8189 19

Integral calibration -the integrals of signals are proportional to the number of protons giving rise to the individual signals -it is convenient to normalize the integration values to simplify the analysis (enabling the analysis to be done by inspection) -select a well-resolved signal, and, if possible, one that you suspect results from a single 1 H nucleus -zoom on this peak, put the cursor on the peak, select Process then Cursors/Integration, and in the Normalization value field put 1.0. Then click Set Integal Value. 1D 1 H double-resonance lab CHEM 4190/6190/8189 20

Advanced Plotting -expand around the peaks in your spectrum (0 4 ppm) -under Process/Plot, click Plot Spectrum and Plot Spectrum Scale (both under Plot Setup), Plot Integrals (under Integrals), Plot Scaled (under Integral Values), and then Plot Page -the relative integral values will appear below the signals on the (hardcopy) plot -try the above set of commands again, but in this case include clicking on Plot Text with the Full Parameters button selected -this will print the acquisition parameters on the hardcopy plot. You will note that these parameters are printed on the left side of the spectrum, so it is often a good idea to leave some blank space to the left of the peaks in your spectrum before you plot the parameters (i.e., in our case, zoom in on the region from about 5 ppm to 0 ppm, as above, in which case there is blank space between the left edge of the spectrum and the peak at 3.5 ppm) Logging out -it is best to remove your sample. Simply click the Switch to #50 button -in the extreme upper left of the screen click the Utilities button, and select Change Operator from the menu 1D 1 H double-resonance lab CHEM 4190/6190/8189 21

Selective Homonuclear Decoupling -first, record a 1D 1 H spectrum of your sample (see pages 1-11) -next, turn off the automated shimming routines by selecting the Start tab, then the Study option, and then deselect Find Z 0 and Gradient Shim. Also, give your experiment a new name (Sample) 1D 1 H double-resonance lab CHEM 4190/6190/8189 22

-then, as before, click the Std 1D tab, then the Proton option, and then double click on the yellowhighlighted (1 min) Proton selection 1D 1 H double-resonance lab CHEM 4190/6190/8189 23

-then, click the Acquire tab, and the Channels option -here you will see two Channels: Observe (channel 1), the nucleus to be observed ( 1 H in our case), and Decouple (channel2), the nucleus to be decoupled (also 1 H in our case). The parameters for the observe channel will not change, but we need to adjust those for the decouple channel -under Observe, you ll see the frequency and nucleus set to 1 H, etc -for the Offset option, you ll see 398.2 Hz, or 1.0 ppm -under Decouple, you ll see default parameters for decoupling 13 C we need to change these for 1 H decoupling (next page) 1D 1 H double-resonance lab CHEM 4190/6190/8189 24

-for the Decouple channel, we ll set Nucleus/Freq. to H1 -Offset (Decouple offset) defines the frequency of the peak that we wish to (selectively) decouple -this is calculated, in ppm as follows: decouple offset = center of peak to be decoupled - center of spectrum + observe offset -for our case, to decouple the peak at 3.4 ppm, this is diagrammed as follows: 6 5 4 3 observe decouple offset offset center of spectrum (6.0 ppm) 1.0 ppm -1.6 ppm center of signal to decouple (3.4 ppm) - the calculation shows that the decouple offset should be set to -1.6 ppm to decouple the peak at 3.4 ppm, assuming the center of the spectrum to be 6.0 ppm -1.6 ppm = 3.4 ppm - 6.0 ppm + 1.0 ppm -ON/OFF/Homo is set to nny and Modulation is set to c or ccc for homonuclear decoupling -we will set the 90 degree pulse width (90 Degree) and power (Pwr) to 300 and 34 respectively. The =dmf parameter will then be set automatically to ~3300. NEVER SET PWR > 38. -the remaining parameters, Waveform and resolution do not need to be adjusted 1D 1 H double-resonance lab CHEM 4190/6190/8189 25

-then, as before, we will select our sample number in the sample tray (31 if our sample was 31) and Submit to Day Queue 1D 1 H double-resonance lab CHEM 4190/6190/8189 26

-retrieve the data as usual. You will notice that the peak at 3.4 ppm is altered dramatically by the rf field applied at its chemical shift (including removal of splitting due to couplings to other protons) -careful analysis of other peaks in the spectrum will reveal loss of couplings (removal of some splittings), indicating coupling to the hydrogen giving rise to the signal at 3.4 ppm Logging out -first, go back to Start/Study and select Find Z 0 and Gradient Shimming -it is best to remove your sample. Simply click the Switch to #50 button -in the extreme upper left of the screen click the Utilities button, and select Change Operator from the menu 1D 1 H double-resonance lab CHEM 4190/6190/8189 27

Goals for Lab #2: 1). Acquire a 1D 1 H spectrum of your sample. Plot (hardcopy) the full spectrum (the region that includes peaks from your molecule) and expansions of individual regions of the spectrum so that the effects of subsequent selective decoupling of individual peaks can be assessed. 2). Selectively decouple the peak at 3.4 ppm. Plot (hardcopy) the full spectrum (the region that includes peaks from your molecule). Plot expansions of the indidual regions so that the effect of this decoupling on all peaks in the spectrum can be assessed. 3). Do the same for the peaks at ~2.25 ppm, ~1.95 ppm, ~1.4 ppm, ~1.1 ppm, and ~0.8 ppm. Exercises and Questions for Lab #2: 1. -Discuss, in general, which signals are good candidates for selective decoupling and which are not. Explain your reasoning. -In menthol, considering the results of your decoupling experiments, which signals, when decoupled, gave valuable information and which did not. Elaborate on each specific case. 2. For lab #1, you created a table with information about the signals in the menthol spectrum including chemical shift, coupling constants, multiplet structure, and assignment. In the table (or in other parts of your report), you justified your assignments based on the information available to you. -Now, revise/update your table. If you made mistakes the first time around, fix them. In addition, revise your assignments based on the new information that you have from the decoupling experiments. Try to assign as many signals as you can. You must thoroughtly justify your assignments. -You will be scored based on all of the information in your table, and in particular your detailed justifications of assignments or revision of assignments based on your new decoupling information. 3. -In your own words, discuss the advantages/disadvantages and usefulness/utility of selective decoupling experiments. 4. For acquiring a simple 1D 1 H spectrum of our compound, we used CDCl 3 as the solvent. Suppose you don t have any CDCl 3, and you decide to use CHCl 3 instead. -What is the concentration of CHCl 3 in 100% CHCl 3 (show your work)? -What challenge will you face in acquiring a 1D 1 H spectrum of menthol (let s assume that the concentration of menthol in our sample is 1 mm) in pure CHCl 3 as the solvent? -How might you overcome these problems (assuming that you can t switch solvents)? 1D 1 H double-resonance lab CHEM 4190/6190/8189 1

SAMPLE: Our sample is ~0.5M menthol in CDCl 3 HO 2 10 4 3 1 5 menthol 9 7 6 8 SIGNAL (LABEL) Chemical Shift (ppm) Integral (normalized values) Multiplicity Coupling constants (Hz) Connectivity / Assignments / Comments a 3.43 1.0 Doublet of triplets 3 J 10,4 =x Hz 3 J 10,9 =y Hz Signal a corresponds to hydrogen 10 in menthol. This signal is a doublet of triplets (split by the two hydrogens at 9 into a triplet and the hydrogen at 4 into a doublet). Because of the inductive effect of the hydroxyl, it is the most downshielded hydrogen in the spectrum. Selective decoupling experiments show b 2.2 Incidentally, and are incorrect. c Etc. 1D 1 H double-resonance lab CHEM 4190/6190/8189 2