Mass Attenuation Coefficients of Lead Nitrate Dilute Solutions for 13.5 cm Thickness at 1173 and 1333 kev

Similar documents
RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Measurement of linear and mass attenuation coefficient of alcohol soluble compound for gamma rays at energy MeV

International Journal of Scientific & Engineering Research Volume 9, Issue 1, January ISSN

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

International Journal of Scientific Research and Reviews

Scholars Research Library. Gamma Ray Photon Interaction Studies of Cu in the Energy Range 10keV to 1500keV

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

Attenuation Coefficient of Soil Samples by Gamma ray Energy

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Determination of the activity of radionuclides

Journal of Chemical and Pharmaceutical Research

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Research Article Coherent and Incoherent Scattering Cross Sections of Some Lead and Sodium Compounds at Angles below 10 for 241 Am Gamma Rays

DETERMINATION OF X-RAY TOTAL ATTENUATION COEFFICIENT IN Zr, Ag, In FOR ENERGY RANGE BETWEEN kev

Experimental and Theoretical Investigation of Gamma Attenuation of Building Materials

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

Evaluation of gamma shielding parameters of bismuth oxide filled polymer composites

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

JRPR. A Study of Shielding Properties of X-ray and Gamma in Barium Compounds. Original Research. Introduction

Compton suppression spectrometry

CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

Journal of Chemical and Pharmaceutical Research

CHAPTER 2 INTERACTION OF RADIATION WITH MATTER

Journal of Chemical and Pharmaceutical Research

Radhakrishnan B*, Kurup P G G**, Ramakrishnan G***, Chandralingam S****

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

An analytic review of the different methods for evaluating the Z-effective of the series of glass [Li 2 O B 2 O 3 SiO 2 MnO]

Gamma-ray shielding of concretes including magnetite in different rate

PHYS 3650L - Modern Physics Laboratory

Chapter 16 Basic Precautions

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Attenuation of Radiation in Matter. Attenuation of gamma particles

Study of Photon Interaction Parameters for Some Oxide Glasses as Gamma Ray Shielding Materials

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Copyright 2008, University of Chicago, Department of Physics. Gamma Cross-sections. NaI crystal (~2" dia) mounted on photo-multiplier tube

Linear attenuation coefficient calculation for both pure silicon (Si) and silicone supported with lead

Study on Mass Attenuation Coefficients and Optical Properties for Boro-Tellurite Glass doped with Barium

Interaction of charged particles and photons with matter

International Journal of Scientific & Engineering Research, Volume 8, Issue 4, April ISSN

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Radiation Detection and Measurement

Measurement of Specific Activities of Some Biological Samples for Some Iraq Governorates

Detection and measurement of gamma-radiation by gammaspectroscopy

Measurement of Shielding Effectiveness of Building Blocks against 662 KeV Photons

Measurement of atomic number and mass attenuation coefficient in magnesium ferrite

Significance of Absorption Coefficients When Determining In Situ Core Saturations by Linear X-ray Scans

Chapter 4 Scintillation Detectors

A comprehensive study on energy absorption and exposure buildup factors for some Vitamins and Tissue Equivalent Materials

Gamma Ray Spectroscopy

Chapter 2 Methods Based on the Absorption of Gamma-Ray Beams by Matter

SODIUM PERTECHNETATE ( 99m Tc) INJECTION (FISSION): Revised Final text for addition to The International Pharmacopoeia (January September 2009)

Quality Assurance. Purity control. Polycrystalline Ingots

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Sample Spectroscopy System Hardware

Gamma Radiation Absorption Characteristics of Concrete with Components of Different Type Materials

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law.

THE COMPTON EFFECT Last Revised: January 5, 2007

Radioisotopes and PET

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

Determination of the mass attenuation coefficient for the contrast agent Iohexol using 662 kev photons from a Cesium-137 source.

Overview about the Work with Liquid Scintillators

Mohammed Jebur Resen AL-Dhuhaibat. Phys. Dep./Sci. Coll./Wasit Uni./Iraq/Wasit /Kut ABSTRACT

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

SCINTILLATION DETECTORS AND PM TUBES

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

K 40 activity and Detector Efficiency

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Experiment 7: Adsorption Spectroscopy I, Determination of Iron with 1,10 Phenanthroline

COMPTON SCATTERING OF GAMMA RAYS

Radioisotopes in action. Diagnostic application of radioisotopes. Steps of diagnostic procedure. Information from various medical imaging techniques

XRF EXPERIMENTS USING REFRACTION TYPE OF GEOMETRY (2π- GEOMETRY) FOR LOW AND MEDIUM Z ELEMENTS AND COMPOUNDS

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Determination of the boron content in polyethylene samples using the reactor Orphée

Figure 1. Decay Scheme for 60Co

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

III. Energy Deposition in the Detector and Spectrum Formation

Liquid Waste Analysis

Neutron Shielding Properties Of Concrete With Boron And Boron Containing Mineral

GAMMA RAY SPECTROSCOPY

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Interaction of particles with matter - 2. Silvia Masciocchi, GSI and University of Heidelberg SS2017, Heidelberg May 3, 2017

Research Article Study of Gamma Ray Exposure Buildup Factor for Some Ceramics with Photon Energy, Penetration Depth and Chemical Composition

Scintillation Detector

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

THALES Project No. 65/1205

Journal of Applicable Chemistry

Bed Expansion in Upflow Moving Catalytic Packed/Expanded Bed Hydrotreating Reactor using Gamma-Ray Densitometry

Gamma dosimetric parameters in some skeletal muscle relaxants

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Calculating standard captured spectra of formation elements

Gamma and X-Ray Detection

Transcription:

Mass Attenuation Coefficients of Lead Nitrate Dilute Solutions for 13.5 cm Thickness at 1173 and 1333 kev Madhuri Dumpala 1, A.S.Nageswara Rao 2 Assistant Professor, Department of Physics, OsmaniaUniversity College for Women, koti, Hyderabad, Telangana State, India 1. Professor, Department of Physics, Kakatiya University, Warangal, Telangana State, India 2. ABSTRACT: The total mass attenuation coefficients determined in deionized water and different concentration lead nitrate dilute solutions at photon energies 1173and1333 kev by using good geometry setup. Gamma ray photons are emitted from source of 60 Co.The measurements has been performed using a gamma spectrometer which contain 2 " 2 " NaI (Tl) detector connected to 8K Multi-Channel Analyser(MCA). The results are in good agreement with the theoretical calculations of X.COM. KEYWORDS: Mass attenuation coefficients, deionized water, Lead nitrate dilute solutions, photon energies, Good- Geometry setup, gamma ray spectrometer. I. INTRODUCTION Increasing usage of radioactive sources in several fields such as medicine, industry and agriculture etc., the study of gamma ray attenuation measurements in elements, compounds has become important. Accurate data on narrow beam attenuation coefficients for gamma rays are required in many fields, such as tomography, X ray fluorescence studies and radiation biophysics. Most of the previous measurements of attenuation coefficients have been performed on the materials in their solid and crystalline forms using various techniques. These observations have been compared with the theoretical values calculated from the mixture rule and various tables [1]. II. BACK GROUND OF RELATED WORK Many measurements of mass attenuation coefficients have been reported for instance Bradley et, al., [2]; Cunningham and John [3]; Hubbell [1 and 4]; Hubbell and Seltzer [5]; Singh et,al.,[6]; Teliet, et al.,[7-13] have used the mixture rule for multi elemental media in order to provide gamma ray attenuation for materials which are generally in liquid form or soluble in solvent, such as water. The observations were compared with the values;those are derived from application of mixture rule by using tabulated values for each element [4]. Gerward [14] has developed the theory of X- ray and gamma ray attenuation in solutions and has elaborated the rule of mixtures of linear and mass attenuation coefficients in the general case, as well as, in the limit of extreme dilution. Kulwant Singh et.al., [15] have measured attenuation coefficients of some dilute solutions at 662 kev. So it is important to study attenuation measurements of deionized water and different dilute solutions. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8266

III. PRESENTATION OF THE MAIN CONTRIBUTION OF THE PAPER In the present work, mass attenuation measurements of different concentration lead nitrate dilute solutions (mixed in deionized water) and deionizedwater have been measured in the energies 1173 and 1333keV for 13.5 cm thickness. IV. PROPOSED METHODOLOGY AND DISCUSSION The mass attenuation coefficients were determined by performing transmission experiments in narrow beam geometry as shown in Fig.1. A reasonable amount of lead shielding was used around the source and detector to prevent detection of scattered radiation from surrounding objects. For the low energy measurements the probability of coherent scattering interactions is relatively high and so very good collimation is required to reduce the contribution of Rayleigh scattered photons reaching the detector. Tight collimation reduces the absolute detection efficiency so that high activity sources must be employed that is around 10 mci strength. At higher energies the probability of elastic scattering becomes much smaller and so scattered radiation is less important which reduces the need for such close collimation. Therefore, source strengths in the range 10-20 µci were found to be adequate for the higher energy measurements. The radioactive sources of strength around 10µCi were procured from BRIT, Mumbai, India and details of the source are given in Table.1. Table.1: Table showing the source, energy and half-life period of the radioactive isotope used in the present work. Source Energy [kev] Half-Life [Years] 60 Co 1173 &1333 5.3 Fig. 1 Schematic diagram of the experimental setup. A 2 " 2 " NaI(Tl) crystal detector with the energy resolution 8% at 662 kev and 8K Multi-Channel Analyzer(MCA) plug-in-card were used with associated electronics to record the pulse-height spectra s of γ-radiations emitted by radioactive sources. h 1, h 2 and h 3 concentration solutions are prepared. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8267

Whereh 1 concentration : 210 g of lead nitrate diluted in 300ml of water. h 2 concentration : 105 g of lead nitrate diluted in 300ml of water. h 3 concentration : 52.5 g of lead nitrate diluted in 300ml of water. 13.5cm thickness glass container is prepared with general method which is used in aquarium shops. This container is used for taking readings with water and dilutes solutions. Thickness of the glass container is measured with vernier calipers. The sample thickness measured in such a way the internal distance of the glass container. Thickness (t) is measured for different areas of thickness of the each container, then the average t value was taken and that is 13.5cm. The Table.2 shows the average density and thickness of the different concentration of lead nitrate dilute solutions.interpolations from tabulated theoretical values of the mass attenuation coefficients for deionized water and different dilute solutions were obtained using X.COM [16].For this we calculated the percentage of lead nitrate and water. Example For h 1 concentration : 210 g of lead nitrate diluted in 300ml of water. Weight of the compound (W c ) =210g. Weight of the solution (W s ) =508.9g. Percentage of lead nitrate (W c / W s )=0.413 Percentage of water=0.587 Simultaneouslyh 2 andh 3 concentrations: For h 2 concentration Percentage of lead nitrate=0.254 Percentage of water=0.746 For h 3 concentrations Percentage of lead nitrate=0.149 Percentage of water=0.851 Density of the sample is measured by using common principle, that is Density (ρ) =Mass (M) /Volume (V) V=M/ρ V water =V mixture ρ mixture =M mixture [ ρ water/ M water] M water = weight of the volumetric flask with water weight of the empty volumetric flask. M mixture = weight of the volumetric flask with mixture weight of the empty volumetric flask. Table.2Average density and thickness of lead nitrate dilute solutions and deionized water Thickness Density Type of sample [cm] [g/cm 3 ] Deionized Water 13.5 13.5±0.27 h 1 concentration of lead nitrate solution h 2 concentration of lead nitrate solution h 3 concentration of lead nitrate solution 13.5 20.032±0.401 13.5 16.606±0.332 13.5 15.529±0.311 For each sample, counts were taken in the following sequence, back ground, no sample, sample, sample, no sample, and so on [17]. Different parts of the sample are exposed to the beam. The counting sequence was continued in most cases until counting statistics contributed less than 0.5% error. The mass attenuation coefficients [cm 2 /g] are obtained from the Beer-Lambert Law: Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8268

μ ρ = 1 tρ ln Io I Where t is the thickness of the sample (cm), and ρ is material density (g/cm 3 ), I o and I are the net counts under the photo peak, without sample and with sample, respectively. I o and I were obtained for same counting time and experimental conditions. The errors in the present investigations are due to [i] counting statistics, [ii] non uniformity of the sample, [iii] density measurements and [iv] scattered radiation reaching the detector within the accepted maximum angle of scattering. In the present investigation this angle was around 3º and the error due to this factor was about 0.3%. The counting statistics were such that the error was less than 0.5%. The fractional error arising due to non-uniformity of the sample was estimated to be in the order of 0.2%. The error in the density measurement is less than 1%. Therefore, the overall error was estimated to be less than 2.25%. V. RESULTS AND DISCUSSION The experimentally measured and calculated values [16] for the mass attenuation coefficients for different concentration of lead nitrate solutions and deionized water sample in the energies 1173 and 1333keV as shown in Table.3. Comparing the experimental and calculated(theoretical) values for the mass attenuation coefficient of deionized water and h 1, h 2 and h 3 concentration lead nitrate dilute solutions for 13.5cm, at energies 1173 and 1333keV.There is no deference between theoretical and measured mass attenuation coefficients of deionized water and different concentration of lead nitrate dilute solutions as shown in Fig.2 and Fig.3 and from these Figures mass attenuation coefficients of deionized water and differentconcentraton dilute solutions nearly equal. 0.07 Experimental Theoretical Mass attenuation coefficient(cm 2 /g) 0.06 0.05 0.04 0.03 0.02 0.01 0.00 Deionized water h1 concentration h2 concentration h3 concentration Type of Sample Fig. 2 Variation in Mass attenuation coefficients of lead nitrate different concentration dilute solutions and deionized water at 1173 kev for 13.5 cm thickness in cm 2 /g. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8269

Experimental Theoretical 0.06 Mass attenuation coefficient (cm 2 /g) 0.05 0.04 0.03 0.02 0.01 0.00 Deionized water h1 concentration h2 concentration h3 concentration Type of sample Fig. 3 Variation in Mass attenuation coefficients of lead nitrate different concentration dilute solutions and deionized water at 1333 kev for 13.5 cm thickness in cm 2 /g. S. No. Type of Sample/Energy 1173keV 1333keV 1 Deionized water a 0.066 b 0.065 0.062 0.061 2 210g of Lead nitrate in 300ml water h 1 Concentration 0.065 0.065 0.061 0.060 3 105g of Lead nitrate in 300ml water h 2 Concentration 0.064 0.064 4 52.5g of Lead nitrate in 300ml water h 3 Concentration 0.064 0.063 Table.3Mass attenuation coefficients of different concentration dilute solutions of lead nitrate for13.5cm thickness in cm 2 /g [error 2.25%] a = Experimental mass attenuation coefficient b= Theoretical mass attenuation coefficient [16] Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8270

VI. CONCLUSIONS The change in mass attenuation coefficients is negligible as concentrations of lead nitrate dilute solution increasing for energies 1173 and 1333keV. Mass attenuation coefficients of deionized water is nearly equal to the mass attenuation coefficients of different dilute solutions of lead nitrate that means there is no deviation between deionized water and different dilute solutions of lead nitrate. REFERENCES [1]. J.H.Hubbell, Photon mass attenuation and energy absorption coefficients from 1keV to 20MeV, Int.J.Appl.Radiat.Isot. 33, 1269, 1982. [2]. D.A.Bradley, C.S.Chang, A.Shukri, A.A.TajuddinandA.M.Ghose, A new method for the direct measurements of energy absorption coefficients of gamma rays, Nucl.Instrum.Meth.Phys.Res.A, 280 392, 1989. [3]. G.A.Cunningham and H.E.John, Calculation of the average energy absorbed in photon interactions, Med.Phys. 7, 51, 1980. [4]. J.H.Hubbell, Photon cross sections, attenuation coefficients and energy absorption coefficients from 10keV to 100MeV, NSRDS NBS, 29, 1969. [5]. H.A.Jahagirdar, B.Hanumaiah and S.R.Thontadaya, Determination of narrow beam attenuation coefficients from a broad beam geometrical configration for 320keV photon, Appl.Radiat.Isot. 43, 1511, 1992. [6]. K.Singh, H.K.Bal, I.K.Sohal and S.P.Sud, Measurement of energy absorption coefficients at 662keV in soil samples, Appl.Radiat.Isot. 42, 1239, 1991. [7]. M.T.Teli, S.S.Malode and L.M.Chaudhari, Study of absorption of 123keV gamma radiation by dilute solutions of zinc sulphate, J.Pure Appl.Phys. 32, 410, 1994a. [8]. M.T.Teli, L.M.Chaudhari and S.S.Malode, Study of absorption of 123keV gamma radiation by dilute solutions of magnesium chloride, Nucl.Instrum.Meth.Phys.Res.A, 346, 220, 1994b. [9]. M.T.Teli, L.M.Chaudhariand S.S.Malode, Study of absorption of 123keV gamma radiation by dilute solutions of sodium chloride, Appl.Radiat.Isot. 45, 987, 1994c. [10]. M.T.Teli, andl.m.chaudhari, Attenuation coefficients for 662keV gamma radiation, measured in dilute solutions, Appl.Radiat.Isot.46, 369, 1995a. [11]. M.T.Teli, and L.M.Chaudhari, Attenuation coefficients of 123keV gamma radiation by dilute solutions of ferrous sulphate, J.Pure.Appl.Phys. 33, 395, 1995b. [12]. M.T.Teli, and L.M.Chaudhari, The attenuation coefficient of ammonium chloride for 662keV gamma radiation, measured for dilute solutions, J.Radiat.Phys.Chem. [1995c]. [13]. M.T.Teli, and L.M.Chaudhari, J.Radiat.Phys.Chem. 47[1996] 365. [14]. L.Gerward, On the attenuation of X- rays and gamma rays in dilute solutions, Radiat. Phys.Chem. 48, 697, 1996. [15]. K.Singh, G.Kaur, V.Kumar, A.K.Dhami and B.S.Lark, Measure ments of some dilute solutions at 662keV, Radiat. Phys.Chem. 53, 123, 1998. [16]. M.J.Berger and J.H.Hubbell Photon cross sections on a personal computer, NBSIR, 87, 1987. [17]. Conner, A.L., Atwater, H.F., Plassmann, E.H., and McCrary, J.H., Gamma ray attenuation coefficient measurements, Phys. Rev A1, 539,1970. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0505179 8271