Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Similar documents
DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

InfraRed Thermometer with Laser Pointer

Manual Dew point scanner PCE-DPT 1

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

MICROLIFE THERMO+ Infrared Thermometer. For safe, touch-free temperature measurement. Instruction Manual

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

Dual laser + type K thermometer INFRARED THERMOMETER

Instruction Manual HI Refractometer for Sodium Chloride Measurements

INSTRUCTION MANUAL Fax: (503)

Today s Weather 24 Hour Forecaster

IR/Thermistor Pen. Instruction Manual

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

566/568. Infrared Thermometers. Getting Started

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Wireless Weather Station. Instruction Manual

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

OPERATING INSTRUCTIONS

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

INFRARED THERMOMETER TM0819

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

The only NO CONTACT technology for Pandemic Situations that projects the temperature on the forehead Advantages of VISIOFOCUS Pro

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

ea980r Digital Anemometer User Manual

Infrared Thermometer Model: and

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Instruction Manual HI Refractometer for Invert Sugar Measurements

The only NON CONTACT thermometer that projects the temperature on the forehead

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Noncontact Thermometer

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

TABLE OF CONTENTS TABLE OF CONTENTS. summit/altitech 2. english. 2english

Rapid RH Portable ph Meter. User's Manual

TG646 WEATHER STATION

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

INFRARED THERMOMETER Model : TM-959

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

WS-9018U Wireless Weather Station. Instruction Manual

2 ACCESSING VARIOUS MODES

Instructions for use: Pushtronex System for Repatha (ri-path-a) (evolocumab) Single-Use On-Body Infusor and Prefilled Cartridge.

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Portable ph/orp/ion Meter D-73 Instruction Manual CODE:GZ A

Mini Environmental Quality Meter

Instruction Manual SEFRAM Thermal Camera

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

WeatherHub2 Quick Start Guide

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

63/66/68. Infrared Thermometers. Users Manual

Honors Chemistry 2016 Summer Assignment

HI Propylene Glycol Refractometer

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Infrared Thermometer Model CA879

INSTRUCTION MANUAL DTH Fax: (503)

Introduction Cautions

Bante210 Benchtop ph Meter Instruction Manual

Bright Advance Corporation

Anemometer Thermometer Hygrometer

ThermoScan Ear thermometer

RADIATION-METER TM-91/TM-92

O P E R A T I N G M A N U A L

What is the maximum distance I can have the remote sensors from the display?

MAGMA NOTE! 21+ USER MANUAL

Red and Green Dot Sight FF26002 USER MANUAL

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Congratulations on purchasing this WS1516IT Professional Weather Station.

06MAR THU 12: User Manual

B Left-hand case side (x1) F

Digital Controller Operation

TEMPERATURE AND THERMAL EXPANSION

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

CONTENTS. La Crosse Technology, Ltd. Page 1

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

The Kestrel Handheld Weather Tracker. 1) If the unit is configured to log data and it is turned off, will it continue to log temperature data?

THERMOFOCUS, a technological innovation

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

PROFESSIONAL WEATHER CENTER WS-1611 PROFESSIONAL WEATHER CENTER. This product offers: Table of Contents. Operation Manual FEATURES: Instruction Manual

alterra/aerial 2 english english

Eppendorf SmartBlock. Instructions for use

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

SkyScan EWS-PRO - Manual -

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

IR-712 IR-720 IR-730

3B SCIENTIFIC PHYSICS

Transcription:

Non - Contact Forehead Infrared Thermometer Care Q7 USER MANUAL - 1 -

Contents: 1. Introduction... 1 2. Safety precautions... 1 3. Features... 2 4. Product description... 2 5. Display description... 3 6. Main technical specifications... 3 7. Accuracy of body temperature readings... 4 8. Normal body temperature ranges by measurement method... 5 9. Normal body temperature ranges by age... 5 10. Thermometer settings... 6 11. Setting for variations in body temperature readings... 6 12. How to take accurate readings... 7 13. Replacing the battery... 8 14. Troubleshooting... 8 15. Key to Symbols... 9-2 -

1. Introduction Congratulations on purchasing the TrueLife Care Q7 professional non-contact thermometer. Using infrared technology, the thermometer produces an instant and highly accurate result. Simply place the thermometer at a distance of 5-8 cm from the subject, press the button and within a second the measurement is displayed. Infrared technology is a useful and versatile aid, not only in the field of family health but also whenever it is important to know the temperature of an object used, e.g. the temperature of food, milk in a baby bottle or room temperature. 2. Safety Precautions a. Read this manual before using the thermometer. b. Only use this thermometer in places where the temperature is 10 40 C. c. Do not place the thermometer close to objects that generate magnetic fields or static electricity. d. Do not expose the thermometer to direct sunlight. e. Do not drop or cause other mechanical damage. f. Store the thermometer in an ambient temperature of 0 50 C. g. Do not use in an environment where the humidity is higher than 85%. h. Measuring body temperature may be affected by sweat, cosmetics, hair or other obstructions. If the measurements show abnormal variations, remove sweat or other potential obstructions or perform the measurement from behind the ear. i. Take measurements at a distance of 5 8 cm from the subject. j. If there are sudden changes in the ambient temperature, or the thermometer has been moved to a place under different environmental conditions, wait 15 to 20 minutes before taking a reading. k. The infrared sensor is fragile. Keep clean and take care when using it. l. If necessary, clean the thermometer with a damp cloth or a cotton bud dipped in alcohol. - 1 -

3. Features a. Temperature measurement uses infrared technology and requires no contact. b. Highly accurate measurements to +/-0.2 C. c. Temperature displayed in Celsius or Fahrenheit. d. Measures not only body temperature, but also air temperature and surface temperature. e. Beeper can be set to alert you to an increase in temperature. f. Automatically stores the last 32 readings. g. Backlit, clear LCD display is easy to read in the dark. h. Automatic off prolongs the battery life. i. 2 modes available body temperature or surface temperature. 4. Product description Parts of the thermometer: 1. Infrared sensor 2. LCD display 3. MODE / SET button 4. UP button 5. DOWN button 6. BACKLIGHT 7. SCAN button 8. Battery cover 2 4 6 3 5 7 8 1-2 -

5. Display description Display data: 1. Surface mode (surface temperature measurement) 2. Body temp mode (body temperature measurement) 3. Temperature reading 4. Memory number of the reading 5. Beeper 6. Temperature scale C / F 7. Low battery warning 8. Summary of stored readings 1 2 Surface Body temp 3 6 7 4 LOG 6. Main technical specifications Units of measurement 0.1 oc (0.1 F) Operating conditions ambient temp. 10 40 C (50 104 F) Storage conditions ambient temp. 0 50 C (32 122 F) Operating conditions humidity 85% Storage conditions humidity 90% Power source 9V DC (a 6F22 battery) Dimensions 150 x 75 x 40 mm -3-5 C F 8

Weight 172 g Measurement range body temp mode 32.0 42.5 C Measurement range surface temp mode 0 100 C Max. reading variation body temp +/- 0.3 C Max. reading variation surface temp +/- 1.0 C Distance from sensor to object 5 8 cm Measurement speed 0.8 seconds Automatic off 7 seconds 7. Accuracy of body temperature readings 32.0 35.9 C (93.2 96.6 F) +/- 0.3 C (0.5 F) 36.0 39.0 C (96.8 102.2 F) +/- 0.2 C (0.4 F) 39.0 42.5 C (102.2 108.5 F) +/- 0.3 C (0.5 F) - 4 -

8. Normal body temperature ranges by measurement method Measurement method Anally Orally In the armpit In ear Normal temperature 36.6 38.0 C (97.8 100.4 F) 35.5 37.5 C (95.9 99.5 F) 34.7 37.3 C (94.4 99.1 F) 35.8 38.0 C (96.4 100.4 F) 9. Normal body temperature ranges by age Age Normal temperature 0-2 36.4 38.0 C (97.5 100.4 F) 3-10 36.1 37.8 C (97.0 100.0 F) 11-65 35.9 37.6 C (96.6 99.7 F) > 65 35.8 37.5 C (96.4 99.5 F) - 5 -

10. Thermometer settings a. Setting measurement mode: Press MODE to toggle between surface temperature reading (it displays 'surface') and body temperature reading (it displays 'body temp') Press and hold MODE / SET for 2 seconds to access further settings. Press MODE / SET again to scroll through the individual settings. b. Pressing and holding MODE / SET for 2 seconds displays 'F-1'. Press UP or DOWN to set the reading to C or F respectively. c. Pressing MODE / SET again displays 'F-2'. Press UP and DOWN to adjust the temperature threshold for the beeper in increments of 0.1 C. d. Pressing MODE / SET again displays 'F-3'. Press UP and DOWN to set the deviation in body temperature in increments of 0.1 C from -3 to +3 C. e. Pressing MODE / SET again displays 'F-4'. Press UP or DOWN to enable or disable the elevated temperature beeper. '0' means OFF and '1' means ON. f. Pressing MODE / SET again clears the display and the settings are saved. 11. Setting for variations in body temperature readings In surface temperature mode the thermometer measures the precise temperature on the surface of the object. In body temperature mode the thermometer reading is the result of adding or subtracting the difference between the surface temperature of the forehead and the internal body temperature. Therefore the result is not the surface temperature of the forehead but the actual body temperature. To determine the variations follow these steps: a. Measure your body temperature in the standard way under the conditions in which you will perform the noncontact measurement. - 6 -

b. Take a non-contact reading using the TrueLife Care Q7 with the same person and under the same conditions. c. Compare the results and adjust the variation settings so that the standard and non-contact readings match (e.g. if the measurement using the standard method is 37.5 C, and using the non-contact method is 36.8 C then the variation must be set to 0.7 C.) 12. How to take accurate readings Hold the thermometer 5 8 cm from the surface of the object or forehead. Press SCAN to take the reading. The measurement is displayed within 1 second. Important notice: a. If the thermometer has not been used for a long time it will take 2 seconds longer to start up while the thermometer measures the current ambient temperature and calibrates. b. If there is sweat, cosmetics, hair or other obstructions on the forehead the thermometer may show measurement variations. In this case, take the reading from behind the ear, making sure there are no obstructions. c. If the ambient temperature is outside the operating range, it will display the message 'ERR'. This means that any reading may have a greater variation than specified in the manual. d. If the body temperature or object temperature are outside the operating range it will display 'HI' for higher and 'LO' for lower than the operating temperature range. 5-8 cm 5-8 cm Body Body - 7 -

13. Replacing the battery a. The battery icon is on the display. If the battery icon flashes this means that the battery should be replaced. A low battery can cause inaccurate results. Open the battery cover, replace the battery and put the cover back on. Insert the battery, making sure the positive and negative are the right way round. If the battery is inserted the wrong way round it may cause damage to the thermometer. b. Remove the battery when the thermometer will not be in use for a long time. c. The thermometer can take 40,000 readings per battery. d. Dispose of the batteries at a collection point or specially designated place. Do not dispose with household waste, in a fire or in water. 14. Troubleshooting a. The reading is unexpected i. Check the body temperature variation settings. ii. The thermometer should be used under stable conditions. The reading may have been taken under frequently changing ambient conditions or when a very hot and cold object have been scanned in quick succession. iii. Note the correct distance of the scanner from the object. It must be 5 8 cm. b. Nothing happens when the buttons are pressed i. Battery may be dead. Replace the battery. ii. The battery may be inserted the wrong way round. Check that the positive and negative are the correct way round. iii. The device may be damaged. Contact the service centre. c. If the problems persist after correctly following the instructions and procedures in this manual, contact your dealer or service centre. Never attempt to repair the device yourself. This product is covered by a 2-year warranty, valid from the date of purchase. - 8 -

15. Key to symbols Shenzhen Calibeur Industries co. CE 0197 the device complies with the European directive on medical devices FC the device complies with the European directive on infrared devices 9V 9V DC power supply BF class insulation Recycle this device by taking it to a collecting point or a specially designated place. Do not dispose of this device in household waste, in a fire of in water. The equipment meets RoHS directive on the use of materials in the manufacture of electrical equipment. The packaging is made from PVC The packaging is recyclable Keep dry. Avoid contact with water. Authorised representative: elem6 s.r.o., Braškovská 15, 16100 Praha 6, Česká republika - 9 -

- 10 -