SEWAGE system Quantum SN 12, SN 16

Similar documents
Rock & Aggregate Drop Inlet Protection

IN-HOUSE PP-R INSTAPLAST

Hydraulic Design Of Polyethylene Pipes

Severe accident risk assessment for Nuclear. Power Plants

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

Telecommunications Pipe

MATERIALS FOR CIVIL AND CONSTRUCTION ENGINEERS

product manual H-4204 Proving Ring Penetrometer

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Conductivity sensor for hygienic applications

THREADED CLOSURES. For access to Filter Vessels, Strainers, Pig Launchers & Receivers. Tube Turns Products

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 10, NO. 5 (2009) PAGES **-**

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Rubber- and cellular buffers

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Impact and Fracture Mechanics Assessment of a Fused Silica Window

Site Investigation and Landfill Construction I

Polyvinyl chloride PVC *

Comparison of core sampling and visual inspection for assessment of sewer pipe condition

Name : Applied Physics II Exam One Winter Multiple Choice ( 7 Points ):

Q1. The chart shows the processes involved in the manufacture of nitric acid from ammonia.

Electromagnetic Flowmeter

Long-term behaviour of GRP pipes

Rheological Properties and Fatigue Resistance of Crumb Rubber Modified Bitumen

flexible couplings for pipe repair

Beta-PPR -The New Performance Level in Polypropylene Plumbing & Heating Systems. Business Unit Pipe January 2006

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Modeling Great Britain s Flood Defenses. Flood Defense in Great Britain. By Dr. Yizhong Qu

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

INTRODUCTION TO PAVEMENT STRUCTURES

One-hand ph/temperature measuring instrument

Non-intrusive, Non-destructive FRP Inspection. Geoff Clarkson UTComp Inc

Dewpoint Meter Data Sheet / Instructions

Advanced Strength of Materials Prof S. K. Maiti Mechanical Engineering Indian Institute of Technology, Bombay. Lecture 27

MECHANICAL BEHAVIOUR OF DAMAGED HDPE GEOMEMBRANES

Design of AAC wall panel according to EN 12602

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

Data Sheet / Instructions. Dewpoint MeterO

Fundamentals of Durability. Unrestricted Siemens AG 2013 All rights reserved. Siemens PLM Software

INFLUENCE OF A WELDED PIPE WHIP RESTRAINT ON THE CRITICAL CRACK SIZE IN A 90 BEND

RELIABILITY ASSESSMENT OF EXISTING STRUCTURES

Dr. Jonathan Gutow Fall Looking for PCBs in Water or Can PCBs Wash out of Landfills and Contaminate Ground Water?

Behavior of an impacted reinforced concrete slab: percussion and punching analysis

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

CELSIUS - ALL WEATHER TIRES

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

HEAVY DUTY SWING-OUT VALVE

Table of Contents What is ? The Chemistry of What Does Protect Against? What Does the Package Include? The

@Copyright 2016 SKAPS Industries.

Theory at a Glance (for IES, GATE, PSU)

Solar Tube Impact Test Report

5. STRESS CONCENTRATIONS. and strains in shafts apply only to solid and hollow circular shafts while they are in the

NEO SERIES Tel.:

HEAVY DUTY SWING-OUT VALVE

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

EN ISO 374 Summary of changes & FAQ s Sept 2017

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

S E A L E D F L A T E X P A N S I O N J O I N T T A P E S

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Calibration and Experimental Validation of LS-DYNA Composite Material Models by Multi Objective Optimization Techniques

GCSE COMBINED SCIENCE: SYNERGY

Telescopes (Chapter 6)

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

Geology 2112 Principles and Applications of Geophysical Methods WEEK 1. Lecture Notes Week 1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

INTI COLLEGE MALAYSIA

D sn 1 (Total 1 mark) Q3. A ball of mass 2.0 kg, initially at rest, is acted on by a force F which varies with time t as shown by the graph.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

TRAM LINE SWITCH POINT HEATING

Cooler-Bypass Thermostat Valve, Size 10

Capacitive Sensors. Contents

Accumulators Virginia KMP Suction Line Accumulators

Sand Control Rock Failure

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

U-Shaped Sediment Traps

SNOWPLOW ACCESSORIES. Factory Original Parts

5. What is the moment of inertia about the x - x axis of the rectangular beam shown?

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS

792A AC/DC Transfer Standard

Members Subjected to Torsional Loads

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

2002 Design Guide Preparing for Implementation

Raise the limits. Eppendorf Research plus

MeteoGroup RoadMaster. The world s leading winter road weather solution

STUDY OF EFFECTS OF VIBRATIONS CAUSED BY RAILWAY TRAFFIC TO BUILDINGS

Solid Mechanics Homework Answers

LEDs in ERCO luminaires

1 Introduction. This brief chapter introduces the subject of Solid Mechanics and the contents of this book

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

NORMACLAMP Hose Clamps

The Arctic - A New Frontier The geological, environmental and engineering challenges for submarine telecommunication cables

GCE Advanced Level 2014

Precision Ball Screw/Spline

earth live neutral (ii) What is the colour of the insulation around the wire labelled T? blue brown green and yellow

Rapid RH Portable ph Meter. User's Manual

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

Transcription:

Infra system

SEWAGE system Quantum SN 12, SN 16 BASIC INFORMATION System QUANTUM combines excellent strength property of PVC and years of experience, research and development in the company Pipelife Czech. It is a top modern sewage system, which exceeds most of the products delivered so far. Pipes QUANTUM SN 12 and SN 16 are tested according to relevant parameters of EN 1401-1, but they exceed many of them. QUANTUM is therefore made according to STO-AO 224-136/2009 specification. Pipes construction They are highstrength three-layer solid pipes according to STO-AO 224-136/2009, outside and inside smooth, dimensions DN 150-DN 400 (DN/OD). The pipes don t contain foam layer. Sandwich construction highlights property of material, presence of phase boundary on each layer limits crack propagation. Outer layer redbrown stone impression resistant Middle layer black and grey ensure pipes statics absorbs impacts Internal layer light grey, ideal for camera inspection improves legibility of internal marking resists the sediment abrasion The pipes have formed socket, which is advantageous comparing to the pipes connected by double sockets/repair sockets which bring double risk of leaking connections. The pipe edges have bevel angle 15 C. page 2

Infra system Reinforced seal ring In the socket there is an elastic ring with two sealing edges. It is protected from damage and UV impacts while storing and manipulation. Reliable sealing is insured by a plastic reinforcement ring. This stops falling out or sealing impression while transport or inexpert installation, the ring can be taken out when cleaning and changing using suitable tools. This version ensures extraordinary tightness and high environment-friendly assurance of pipe system. (see picture 1 and ensured values below) Pic. 1 Internal marking Pipes internal surface is marked by standard specified range and intervals. Internal marking on each socket increases certainty the most important parameters for pipes checking are accessible from the inside of the pipe after groove filling (see picture 2). It enables checking if the pipes weren t replaced with cheaper or less quality pipes by accident or intentionally while building. Pic. 2 Resistance Great impact resistance of the QUANTUM system allows installation even by -10 C,. Pipes are marked with the ice crystal sign according to EN 1401. Pipes can be used for transport of warm water up to max. 60 C Pipes Quantum and their sealing rings withstand in ph 2 13 (acids and hydroxides), they are resistant to many organic compounds (except acetone, toluene). For oily waters (petrol stations, garages, car repair shops) oil proof rings can be ordered by Pipelife. PVC Comparing to other plastics suitable for pipes producing, PVC excels high E-modulus, low creep value and good abrasion resistance. Mixture for QUANTUM SN 12 has high hardness, the pipes are therefore resistant against big soil particles impression which might damage the pipes. As well the material is very tenacious which enables laying even at -10 C. Medium specific gravity 400 kg/m 3 Short-term modulus of elasticity 3000-3600 N/mm² Long-term modulus of elasticity 1750-2000 N/mm² (E 50years ) Coefficient of thermal dilatation 0,08 mm/mk Thermal conductivity 0,15 W/K.m Chemical resistance according to standard ISO TR 7620 QUANTUM testing beyond the normal standards kg Crack resistance at low temperatures 2 m 0 C Stones and tools falling and crashes can t be avoided at construction. Besides testing for common pipes according to ČSN EN 744, the impact resistance according to ČSN EN 1411 test is done at modern systems (staircase method). Metal weight of 12,5 kg falls on a pipe DN 300 at 0 C from heights of at least 1 meter, while the pipe wall mustn t be damaged (Pic. 3). Pipe system QUANTUM SN 12 meets the falling height of 2 meters, therefore it can be marked the symbol ice crystal. Root penetration resistance Long-term environment-friendly certainty of system QUANTUM SN 12 is proven by test. According to EN 14 741 the strength needed for rising the socket is measured within 2000 hours (by airflow or nitrogen flow in quantities of 200ml/min see Pic. 4). Contact force is extrapolated to the hundred year life. ITC Zlín č.j. 41223923 protocol determined sealing ring pressure 4,8 bars for 100 years of use. 16x Pic. 3 Pic. 4 page 3

SEWAGE system Quantum SN 12, SN 16 View of quantum usage area Areas with high static load (important roads, airports) Areas with high traffic and dynamic load In the presence of groundwater In problem soil and landfilling At system with the lowest operating costs demands At low slope At high tightness demands (environment and hygiene) At high speed of waste water At low depth of covery Designing data Material PVC all layers Wall structure compact 3-layer, internal layer light grey Supplied diameters DN 150-200 - 250-300 - 400-500 - 600-800 Ring stiffness 12 kn/m 2 /16 kn/m 2 Supplied lengths SN 12: 1 3 6 m, SN 16: 6m Pipes marking outside and inside Seal ring double-edged with reinforcing ring Laying temperature min. -10 C, max. 50 C Maximum temperature of the medium permanently 40 C, temporarily 75-80 C Approximate depth of cover* min. 0,5 m, max. 10 m Recommended soil compaction 90 % - 98 % PS Maximum speed of the medium 15 m/s * Figures are valid in average soils. Pipes behavior depends on traffic load, kind of soil and its compaction level. Although system QUANTUM has excellent static parameters, don t underestimate the importance of the static calculation. Figures in the chart don t substitute static assessment of particular case. page 4

Infra system Quantum PIPES With internal marking, socket with plastic reinforced sealing ring Smooth 3-layer solid PVC pipes QUANTUM SN 12 Catalogue number Q12- / SN 12 SN 12 DN D1 S construction length L (m) 1 3 6 D2 D3 e f1 u Lb kg/m* 150 160 5,5 x x x 160,5 174,3 12,6 12,5 50,7 75,8 3,9 200 200 6,6 x x x 200,6 216,2 15,7 13,5 60,2 89,4 5,5 250 250 8,2 x x x 250,6 272,9 19,7 20,8 72,3 112,8 9,5 300 315 10,0 x x x 315,7 338,9 24,8 22,7 87,9 135,4 14,9 400 400 12,6 x x x 400,8 427,1 31,5 25,6 108,3 165,4 24 Order example: Q12-300/6 (pipe Quantum SN 12 DN 300 length 6 m) *Approximate weight. Dimensions in mm. Smooth 3-layer solid PVC pipes QUANTUM SN 16 Catalogue number Q16- / SN 16 SN 16 DN D1 S construction length L (m) 1 3 6 D2 D3 e f1 u Lb kg/m* 150 160 6,0 - - x 160,5 174,3 12,6 12,5 50,7 75,8 4,7 200 200 7,5 - - x 200,6 216,2 15,7 13,5 60,2 89,4 7,9 250 250 9,3 - - x 250,6 272,9 19,7 20,8 72,3 112,8 12,0 300 315 11,7 - - x 315,7 338,9 24,8 22,7 87,9 135,4 17,2 400 400 14,9 - - x 400,8 427,1 31,5 25,6 108,3 165,4 29,7 500* 500 19 - - x - - - - - 200-600* 630 23,4 - - x - - - - - 240-800* 800 29,5 - - x - - - - - 270 - * Grey colour, according to EN 13476 System QUANTUM offers a wide assortment of fittings SDR34, nevetrheless it is allowed to use normal KG fittings SDR 41 without loss of static performace of the whole sewage line. Regulations for design and construction. Technical modifications reserved. All details without warranty. Edition 3/2013 page 5