2D GEOPHYSICAL EVALUATION OF SUB-SOIL CONTAMINATION - A CASE STUDY

Similar documents
RESISTIVITY IMAGING OF CRUDE OIL SPILL IN OGULAHA COASTAL COMMUNITY, BURUTU L.G.A, DELTA STATE, NIGERIA

1-D Electrical Resistivity Survey For Groundwater In Ketu-Adie Owe, Ogun State, Nigeria.

International Journal of Advancements in Research & Technology, Volume 5, Issue 11, November ISSN

Geophysical Investigation of Some Flood Prone Areas in Ota, Southwestern Nigeria

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

International Journal of Scientific & Engineering Research, Volume 7, Issue 11, November ISSN

Aquifer Vulnerability Investigation Using Geoelectric Method in Parts of Sapele Local Government Area of Delta State, Nigeria

Geophysical investigation of saline water intrusion into freshwater aquifers: A case study of Oniru, Lagos State

VOL. 3, NO. 1, January 2013 ISSN ARPN Journal of Science and Technology All rights reserved.

2-D RESISTIVITY IMAGING SURVEY FOR WATER-SUPPLY TUBE WELLS IN A BASEMENT COMPLEX: A CASE STUDY OF OOU CAMPUS, AGO-IWOYE SW NIGERIA

Report and Opinion 2010;2(5)

Construction Of 2-D Electrical Resistivity Field To Characterize The Subsoil In North-Eastern Part Of Alimosho Area Of Lagos State, Nigeria.

Groundwater Assessment in Apapa Coast-Line Area of Lagos Using Electrical Resistivity Method

Scholars Research Library

Journal of Geology & Geophysics

Elijah Adebowale Ayolabi, Ph.D. 1, Adetayo Femi Folorunso, M.Sc. 2*, Ayodele Franklin Eleyinmi, B.Sc. 1, and Esther O. Anuyah, B.Sc.

VOL. 7, NO. 5, MAY 2012 ISSN ARPN Journal of Engineering and Applied Sciences

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

Geophysical Study of Limestone Attributes At Abudu Area of Edo State, Nigeria

Geophysical mapping of the occurrence of shallow oil sands in Idiopopo at Okitipupa area, South-western Nigeria

Hydrocarbon Potential of Some Afowo Shale Deposits in Part of South Western Nigeria

Accepted 15 December, 2012

Scholars Research Library. Geophysical investigation of effects of topographic complexities on groundwater potential in Ibusa, Delta State Nigeria

Detection and Monitoring of Dumpsite-Induced Groundwater Contamination using Electrical Resistivity Method.

Reserve Estimation from Geoelectrical Sounding of the Ewekoro Limestone at Papalanto, Ogun State, Nigeria.

Structural Control For Bitumen Seepages in Imeri, Southwestern Nigeria

Relevance of 2D Electrical Imaging in Subsurface Mapping: Case Study of National Animal Production Research Institute (NAPRI), Zaria.

Geoelectric and Geotechnical Methods of Subsurface Conditions In Lagos State Polytechnic, Ikorodu, Nigeria

Vertical Electrical Sounding Survey for Groundwater Exploration in Parts of Anyigba and its Environs, in the Anambra Basin of Nigeria

3D Electrical Resistivity Tomography (ERT) Survey of a Typical Basement Complex Terrain

Aquifer Vulnerability Assessment in Some Towns of Yenagoa, South-South Nigeria

A Geophysical Investigation for Subsurface Characterization and Structural failure at the Site of a Building, Southwestern Nigeria

The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation around Bomo Area, Kaduna State, Nigeria

Geophysical Investigation of Foundation Condition of A Site in Ikere- Ekiti, Ekiti State, South-Western Nigeria

Geophysical Investigation of Ground Water Using Vertical Electrical Sounding and Seismic Refraction Methods

Key words: Aquifer, contaminants, electrical impedance tomography, groundwater, landfills, leachate

INTEGRATED GEOPHYSICAL INVESTIGATION OF SEQUENCE OF DEPOSITION OF SEDIMENTARY STRATA IN ABAKALIKI, NIGERIA ABSTRACT

Scholars Research Library. Predicting the aquifer characteristic within the major towns in Ndokwa land

INTEGRATED INVESTIGATION TO LOCATE A WASTE DISPOSAL AREA

Geoelectric Evaluation of Groundwater Potential: A Case Study of Sabongida-Ora and Environs, Southern Nigeria

Groundwater Exploration In Parts Of Mangu- Halle North-Central Nigeria.

Hydrogeophysical investigation in selected parts of Irepodun/Ifelodun local government area of Ekiti State, Southwestern Nigeria

Aspects of Geophysical Exploration for Groundwater Using Vertical Electrical Sounding (VES) in Parts of University of Benin, Benin City, Edo State

2D Resistivity Imaging Investigation of Solid Waste Landfill Sites in Ikhueniro Municipality, Ikpoba Okha Local Government Area,Edo State, Nigeria.

Geophysical Investigation of a Suspected Foundation Failure at Ogbomoso, Southwestern, Nigeria.

Electrical Resistivity Imaging of a Coal Deposit at Tai Area of Gombe State, North Eastern Nigeria

Characterization of a bitumen seepage in Eastern Dahomey Basin, SW, Nigeria

Application of Electrical Resistivity Tomography in Mapping Subsurface Hydrocarbon Contamination

GEOELECTRICAL INVESTIGATION OF GROUNDWATER CONDITION IN OLEH, NIGERIA

Geophysical Investigation for Foundation Studies at Ogudu River Valley Estate, Lagos, Southwestern, Nigeria.

Geophysical Investigation of Egbeta, Edo State, Nigeria, Using Electrical Resistivity Survey to Assess the Ground water Potential

Morenikeji P. Anjorin, B.Tech. 1 and Martins O. Olorunfemi, Ph.D. 2*

EVALUATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD IN OKENUGBO AREA, AGO - IWOYE, SOUTHWESTERN, NIGERIA.

Hydro-Geophysical Study of River Niger Floodplain at Jebba-North, Nigeria

Geophysical Investigation: A Case Study of Basement Complex, Nigeria

Lithofacies Characterization of Sedimentary Succession from Oligocene to Early Miocene Age in X2 Well, Greater Ughelli Depo Belt, Niger Delta, Nigeria

Ground Magnetic and Electrical Resistivity Mapping for Basement Structurs over Charnokitic Terrain in Ado-Ekiti Area, Southwestern Nigeria

Determination of Geothermal Gradient in the Eastern Niger Delta Sedimentary Basin from Bottom Hole Temperatures

Site Investigations of Subsurface Conditions Using Electrical Resistivity Method and Cone Penetration Test at Medina Estate, Gbagada, Lagos, Nigeria

Vertical electrical sounding (VES) for subsurface geophysical investigation in Kanigiri area, Prakasam district, Andhra Pradesh, India

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor and Environs, Aniocha- South Local Government Area, Delta State, Nigeria

Groundwater Potential Evaluation of College of Engineering, Afe Babalola University, Ado-Ekiti, Southwestern Nigeria

Causes of Borehole Failure in Complex Basement Terrains: ABUAD Case Study, Southwestern Nigeria. w w w. a j e r. o r g Page 192

K. A. Murana, P. Sule, A.L. Ahmed, E.M. Abraham and E.G. Obande. 1. Introduction

ATBU, Journal of Science, Technology & Education (JOSTE); Vol. 4 (4), December, 2016 ISSN:

Geoelectric Delineation of Hydrocarbon Spill in Abesan Lagos, Nigeria

MUHAMMAD S TAMANNAI, DOUGLAS WINSTONE, IAN DEIGHTON & PETER CONN, TGS Nopec Geological Products and Services, London, United Kingdom

MICRO LEVEL GEO-RESISTIVITY SURVEY THROUGH V.E.S. TEST FOR GROUNDWATER FEASIBILITY STUDY AND SELECTION OF BORE WELL SITES IN PIPILI BLOCK OF PURI

Hydro-Geophysical Investigation of the Federal Housing Estate Akure, Southwestern Nigeria

Technical Feasibility of Direct Application of the Nigerian Tar Sand Deposits as Road Asphalt.

Geophysical Investigation of the Precambrian Marble Occurrence in Itobe Area, Central Nigeria

PARTICLE SIZE ANALYSIS OF SOME SIDEWALL CORES FROM KU-1 WELL, OFFSHORE BENIN BASIN, NIGERIA.

Evaluation of Subsurface Formation of Pabna District, Bangladesh

GSJ: Volume 6, Issue 4, April 2018, Online: ISSN

APPLICATION OF ELECTRICAL RESISTIVITY TOMOGRAPHY FOR SAND UNDERWATER EXTRACTION

S.I. Fadele, M.Sc. 1 ; P.O. Sule, Ph.D. 1 ; and B.B.M. Dewu, Ph.D * ABSTRACT

International Journal of Scientific & Engineering Research, Volume 7, Issue 3, March ISSN

RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Scholars Research Library. Induced polarization interpretation for subsurface characterisation: A case study of Obadore, Lagos State

Underground water exploration of Oleh, Nigeria using the electrical resistivity method

2-D Resistivity Study: The Horizontal Resolution Improvement by Introducing the Enhancing Horizontal Resolution (EHR) Technique

An application of 2D electrical resistivity tomography in geotechnical investigations of foundation defects: A case study

To get you thinking Explain how these different layers of rock formed? Why are these layers different colors? Sedimentary Rocks

=%REPORT RECONNAISSANCE OF CHISHOLM LAKE PROSPECT. October 25, 1977

Instrumentation for in-situ foundation investigation in Lagos, South West (SW) Nigeria

High-resolution Sequence Stratigraphy of the Glauconitic Sandstone, Upper Mannville C Pool, Cessford Field: a Record of Evolving Accommodation

Groundwater Exploration of Lokpaukwu, Abia State Southeastern Nigeria, Using Electrical Resistivity Method

Determination of Incompressibility, Elasticity and the Rigidity of Surface Soils and Shallow Sediments from Seismic Wave Velocities

DETECTION OF GROUNDWATER POLLUTION USING RESISTIVITY IMAGING AT SERI PETALING LANDFILL, MALAYSIA

Electrical Resistivity Survey Forground Water At Eye Zheba Village, Off Bida - Minna Road

3.0 GEOLOGY AND HYDROGEOLOGY

A Case Study of High-Resolution Gravity and Wenner-Schlumberger Resistivity for Geotechnical Engineering: An Example from North Jordan

Determination of Thickness of Aquifer with Vertical Electrical Sounding

Anomaly effects of arrays for 3d geoelectrical resistivity imaging using orthogonal or parallel 2d profiles

Follow this and additional works at: Part of the Geology Commons

TWO DIMENSIONAL ELECTRICAL IMAGING OF THE SUBSURFACE STRUCTURE OF BOMO DAM ZARIA, KADUNA STATE NORTH CENTRAL NIGERIA

Application of 2-D resistivity survey to groundwater aquifer delineation in a sedimentary terrain: A case study of south-western Nigeria

Preliminary Geophysical Investigation of Orin Clay Deposit, Southwestern Nigeria: Deductions, Implications and Possible Applications

Cattaraugus Creek: A Story of Flowing Water and the Geology of the Channel It Flows Through Presentation to West Valley Citizen Task Force 4/27/16

Electrical resistivity imaging of contaminant zone at Sotubo dumpsite along Sagamu-Ikorodu Road, Southwestern Nigeria

Transcription:

Petroleum & Coal ISSN 1337-7027 Available online at www.vurup.sk/petroleum-coal Petroleum & Coal 57(2) 135-142, 2015 2D GEOPHYSICAL EVALUATION OF SUB-SOIL CONTAMINATION - A CASE STUDY A.A. Ameloko, O. O. Ojigbo Department of Petroleum Engineering, Covenant University, Ota, Nigeria Corresponding mail:tonyameloko@yahoo.com, anthony.ameloko@covenantuniversity.edu.ng Received January 15, 2015, Accepted April 20, 2015 Abstract In this study, 2D surface resistivity survey was undertaken around two power houses in Covenant University Ota in Ogun State, Nigeria to investigate the possible spread within the subsurface, of disposed used hydrocarbon products. The 2D resistivity imaging technique using the Wenner array method was adopted for the survey with the aid of the SAS 1000 Terrameter. Five traverses were occupied with two of them (traverses 1and 4) obtained 3 m away from the two power houses, while the remaining three served as control. The study delineated three subsurface geoelectric layers with resistivity values ranging from 57 Ωm to 1258 Ωm on all the profiles. The inferred lithologies from the 2D resistivity inversion are topsoil, sandy clay and lateritic materials. The high resistivity values (800 Ωm - 1258 Ωm) on traverse 1 near the power house behind College of Science and Technology (CST) building may be as a result of the contamination arising from the disposed hydrocarbon products. Traverses 2 to 5 however showed no evidence of contamination of the soil around the study area. The results of the analysis have shown that no appreciable amount of contamination has been observed as a result of the disposal of used hydrocarbon products around the study area. However, continuous disposal of used diesel and other hydrocarbon products around the power houses in the University pose a lot of danger of contamination to the environment and underground water body with time. Keywords: Contamination; Hydrocarbon; Resistivity Structure; Subsurface; Traverse. 1. Introduction Contamination from hydrocarbon products such as gasoline, diesel and heavy oils as well as the possible scope of the groundwater bodies is one of the major current environmental issues of great concern in Nigeria. The spills may occur as a result of blowouts due to overpressure, equipment failure, operators errors, corrosion, sabotage (vandalisation of pipelines), pigging operations, flow line replacement, flow station upgrades, tank rehabilitation and natural phenomena such as heavy rainfall, flooding, falling of trees and lightening [1]. When this happens, the ecosystem suffers tremendously. Whenever there is oil spillage within an environment either by surface tank or pipes, it percolates the subsurface and the underlying strata. The degree of infiltration of the oil is dependent on a number of factors: Viscosity (physical properties of oil that determine the degree of free flow through a medium). Less viscous petroleum products like kerosene, diesel, and gasoline constitute a major source of contamination than the more viscous products like oil and other lubricant. The former will infiltrate and transmit faster through any sand medium than the later. Both surface and underground water may be negatively affected as the percolating hydrocarbon substances mixes with the underground water and get them contaminated. Thus, the need to ascertain the extent the subsurface water has been affected by hydrocarbon leakage from the pipelines and other sources of discharge of these products into the environment. The study aims at investigating the likelihood of contamination of groundwater around some power houses in Covenant University, where used hydrocarbon products like diesel and gas are disposed on the ground around these power houses.

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 136 2. Location of Study area Covenant University is located in Ado Odo Ota local Government of Ogun State, Southwestern Nigeria. The area lies within Latitude 3 9' 29" E and Longitude 6 40' 17" N (Figure 1), with an elevation of approximately 40 m above sea level. Covenant University is located at Km 14 along the Sango-Idi-roko road with topography of the area relatively flat and gentle undulations. Figure 1 Google Earth map showing location of study area and traverses (T) 3. Geology of the study area The study area is located in the eastern Dahomey basin of the southwestern Nigeria. The stratigraphy of the eastern Dahomey basin has been discussed by various workers and several classification schemes have been proposed. These notably include those of [2-9] among others. Inspite of all these classification schemes, there are still controversies on age assignments and nomenclatures of the different lithological units within the basin. Omatsola and Adegoke [3] proposed the Cretaceous sequence in the eastern Dahomey basin as beginning with the Abeokuta Group, made up of three formations from oldest to the youngest namely; the Ise, Afowo and Araromi Formations. The Ise Formation unconformably overlies the basement complex of southwestern Nigeria and consists of conglomerates and grits at base and in turn overlain by coarse to medium grained sands with interbedded kaolinite. The conglomerates are unimbricated and at some locations, ironstones occur [7]. The age is Neocomian to Albian. Overlying the Ise Formation is the Afowo Formation, which is composed of coarse to medium grained sandstones with variable but thick interbedded shales, siltstones and claystone. The sandy facies are tar-bearing while the shales are organic - rich [10]. The lower part of this formation is transitional with mixed brackish to marginal horizons that alternate with well sorted, sub-rounded sands indicating a littoral or estuarine near-shore environment of deposition. Using palynological assemblage, Billman [6] assigned a Turonian age to the lower part of this formation, while the upper part ranges into the Maastritchtian. The Araromi Formation overlies the Afowo Formation and has been described as the youngest Cretaceous sediment in the eastern Dahomey basin [3]. It is composed of fine to medium grained sandstone at the base, overlain by shales, siltstone with interbedded limestone, marl and lignite. This Formation is highly fossiliferous containing abundant planktonic foraminifera, ostracods, pollen and spores. Omatsola and Adegoke [3] assigned a Maastritchtian to Palaeocene age to this formation based on faunal content. The lithostratigraphic units of the Cretaceous to Tertiary sedimentary

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 137 sequence of eastern margin of Dahomey basin is summarized in Table 1. The Ewekoro Formation overlies the Araromi Formation in the Eastern Dahomey basin. It is an extensive limestone body, which is traceable over a distance of about 320km from Ghana in the west, towards the eastern margin of the Dahomey basin in Nigeria [11]. Elueze and Nton, [8] has reported that the limestone is of shallow marine origin owing to abundance of coral line algae, gastropods, pelecypods, echinoid fragments and other skeletal debris. It is Palaeocene in age. Overlying the Ewekoro Formation is the Akinbo Formation, which is made up of shale and clayey sequence [4]. Table 1 Stratigraphy of eastern Dahomey basin Figure 2 Geological map of eastern Dahomey Basin (modified after Billman [6] )

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 138 4. Method of Investigation In order to map the possibility of soil contamination, a total of five Constant Separation Traverses were carried out within the study area using the Wenner array electrode configuration and electrode spacing between 2 to 12 m along the traverses. Traverses 1 and 4 were occupied 3 m away from the polluted portion around the power houses behind the College of Science and Technology (CST) (figure 2) and Dorcas Hall (figure 1), while traverses 2, 3 and 5 located at 30 and 20 meters away from the power houses served as control traverses ( figure 1). Figure 3 Pollution around the power house behind CST Figure 4 Pollution around the power house behind Dorcas Hall The Abem Terrameter SAS 1000 and the Universal Traverse Mercator (UTM) coordinates with the aid of a GERMIN 12 channel personal navigator (GPS) unit were deployed to obtain the resistance of the subsurface and the location of each of the traverses. The resistance was later multiplied by the appropriate geometric factor to obtain the apparent resistivity values, [12-14]. The observed field data were used to produce pseudosections for each of the traverses which were used as initial model for the computer iteration technique via Dipro software to produce model contours. 5. Results and discussion The results of the 2D resistivity inversion around the two locations are shown in figures 5 to 9 as 2D inverted resistivity depth models. Traverse 1 This traverse was obtained about 3 m from the power house behind CST and 90 m in length. A critical view of the model indicates that the subsurface under this profile is characterised by materials with apparent resistivity ranging from 93-1258 Ωm. The top soil here

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 139 has resistivity values ranging from about 93-150 Ωm and thickness of about 1.5 m with sandy-clay lithology. Underlying the top soil are materials with resistivity values ranging from 150-600 Ωm (green and red colours) indicating lateritic clayey materials. The zones with very high resistivity values (purple colour) ranging from about 800-1258 Ωm indicate vertical migration of the contaminants from the power house to the subsurface environment right from the surface to a depth of 5 m. Contaminant migration Figure 5 Inverted 2D resistivity structure along traverse 1 Traverse 2 The length of profile 2 was 100 m and was obtained about 30 m away from the overhead water tank opposite the Department of Chemical and Petroleum Engineering building, about 80 m away from the power house. From this control model, the resistivity values for the entire profile ranges from 57-746 Ωm with three distinct subsurface layers. The top soil along this traverse has resistivity values ranging from about 57-150 Ωm and thickness of about 1.0 m with sandy-clay lithology. The second layer extends from 1.0-2.0 m of depth with resistivity values ranging 206-400 Ωm and a sandy composition. The third layer with resistivity values ranging from 400-746 Ωm represents lateritic/clayey materials. This is confirmed from excavation of laterite currently going on behind the University for road construction purpose nearby (about 500 m away from this point). Compared with traverse one, the maximum resistivity values obtained here does not suggest any likelihood of contamination of the subsurface from the nearby power house. Figure 6 Inverted 2D resistivity structure along traverse 2 Traverse 3 Traverse 3 was obtained about 30 m away from the power house and 50 m in length. The inverted 2D resistivity structure delineates three subsurface geoelectric layers. The top soil (sandy clayey material) with resistivity values ranging from 247-300 Ωm from

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 140 the surface to a depth of about 1.0 m. This zone is underlain with materials with medium resistivity values ranging from 300-570 Ωm and extending from 1.0 m to 2.0 m depth. This region represents sandy materials. The relatively higher resistivity zone (red to purple), with values ranging from 571-753 Ωm, and extending from the origin to about 26 m along the profile is suggestive of a huge deposit of lateritic material. The portion from the 26 m mark to the end bounding the laterite indicates gradual weathering of the laterite deposit. Figure 7 Inverted 2D resistivity structure along traverse 3 Traverse 4 Traverse 4 was 50 m in length and was acquired 3 m away from the power house near Dorcas Hall. The aim was to, like profile one observe if there is migration of the contaminants from the power house towards the subsurface environment. From the 2D resistivity model, the entire profile is characterised by three geoelectric layers with resistivity values ranging from 203 to 536 Ωm. The top soil along this traverse has resistivity values ranging from about 203-300 Ωm and thickness of about 1.0 m with sandy-clay lithology. The second layer extends from 1.0-2.0 m of depth with resistivity values ranging 300-420 Ωm and a sandy composition. The third layer with resistivity values ranging from 420-536 Ωm represents lateritic/clayey materials. Again we can see evidence of weathering occurring on the lateritic material from the 16 m to 24 m mark along the traverse. Figure 8 Inverted 2D resistivity structure along traverse 4 Traverse 5 Traverse 5 was 50 m in length and was acquired 20 m away from the overhead water tank near Dorcas Hall to serve as control. The inverse 2D resistivity model shows variation of resistivity values ranging from 197 to 645 Ωm. The top soil has resistivity values ranging from about 197 to 300 Ωm (blue and green) and thickness of about 1.0 m. The second inverted layer has resistivity values varying from 300 to 500 Ωm. The thickness of this layer varies from 1.0 to 2.0 m across the profile with sand and clay lithology. The last layer

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 141 (purple colour) with relatively higher resistivity values ranging from 500 to 645 Ωm is reflective of lateritic materials that characterise the area. Figure 9 Inverted 2D resistivity structure along traverse 5 6. Conclusion The results of the analysis generally showed no evidence of contamination on traverses 2, 3, 4 and 5 except for traverse 1 where we see some level of contamination as reflected in the anomalously high resistivity values (800-1258 Ωm) associated with the traverse. However, continuous disposal of used diesel and other hydrocarbon products around the power houses in the University pose a lot of danger of contamination to the environment and underground water body with time. Also from the analysis of the models generated from the study, three major lithologies have been identified due to the shallow depth of investigation. These geo-electric layers have resistivity values ranging between 93 to 300 Ωm for the first layer, while the second layer with sandy clayey composition has resistivity values between 200 to 500 Ωm. The third layer with the highest resistivity values on all the traverses ranges from 420 to 753 Ωm. References [1] Atakpo, E.A. and Ayolabi, E.A. (2008). Evaluation of aquifer vulnerability and the protective capacity in some oil producing communities of western Niger Delta. Environmentalist, Springer. DOI 10.1007/s 10669-008-9193-3 [2] Jones, H.A. and R.D. Hockey, 1964. The Geology of part of southwestern Nigeria. Geol.Surv. Nigeria Bulletin, 31. [3] Omatshola, M.E. and O.S. Adegoke, 1981. The tectonic evolution and Cretaceous stratigraphy of the Dahomey Basin. J. Mining and Geol., 54: 65-87. [4] Ogbe, F.G.A. 1992. Stratigraphy of strata exposed in Ewekoro quarry, Western Nigeria. [5] Coker, S.J., Ejedawe, J.E. and Oshiorienua 1983. Hydrocarbon source potential of Cretaceous rock of Okitipupa Uplift, Nigeria. Journal of Mining and Geology. Vol. 22 pp163-169. [6] Billman, H.G; 1992. Offshore Stratigraphy and Paleontology of the Dahomey Embayment, West African. N.A.P.E Bulletin Vol. 7 (2) 121-130p. [7] Nton, M.E. (2001). Sedimentological and geochemical studies of rock units in the Eastern Dahomey Basin, Southwestern Nigeria. Upbli. Ph.D Thesis University of Ibadan, 315pp. [8] Elueze, A.A. and Nton, M.E., 2004. Organic geochemical appraisal of limestones and shales in part of Eastern Dahomey basin, Southwestern Nigeria. Journal of Mining and Geology, vol. 40, no.1 pp 29-40. [9] Nton, M.E., Eze, F.P. and Elueze, A.A. 2006. Aspects of source rock evaluation and diagnostic history of the Akinbo shale, Eastern Dahomey basin, Southwestern Nigeria. Nigerian Association of Petroleum Geologists Bulletin, Vol. 19 No. 1,pp 35-49.

A. A. Ameloko, O. O. Ojigbo/Petroleum & Coal 57(2) 135-142, 2015 142 [10] Enu, E.I. 1990. Nature and occurrence of tar sands in Nigeria In: Ako, B.D. and Enu, E.I., (Eds) Occurrence, utilization and economics of tar sands. Nigeria Mining and Geosciences Society publication on tar sands workshop. Olabisi Onabanjo University, Ago- Iwoye., pp 11-16. [11] Jones, H.A. and Hockey, R.D. 1964. The geology of part of Southwestern Nigeria. Geological survey of Nigeria. Bull. 31,87P [12] Zohdy, A.A.R., Eaton, G.P., and Mabey, D.R. (1974). Application of surface geophysics to groundwater investigation. U.S. Geological survey BK2, Chapter D1, pp 47-55. [13] Ojo, J. S., Ayangbesan, T. E. and Olorunfemi, M.O. (1990). Geophysical survey of damsite: A case study. Journal of Mining and Geology, 26 (2): 221-229. [14] Olorunfemi, M.O. and Okhue, E. T., 1992. Hydrogeologic and geologic significance of a geoelectric surface at Ife, Nigeria. Journal of Mining and Geology, 28 (2); 221-229.