Using Finite Element Analysis and Experimental Analysis on Vibration of a Piezoelectric

Similar documents
The dynamic characteristics of a valve-less micropump

Study on a PZT-actuated diaphragm pump for air supply for micro fuel cells

Theory and Experimental Verification on Cymbal shaped Slotted Valve Piezoelectric Pump

Drug Delivery Systems

Presented. Nayana.L MTech, CAID

INVESTIGATION OF ELECTRO-MECHANICAL FACTORS EFFECTING PIEZOELECTRIC ACTUATOR FOR VALVELESS MICROPUMP CHARACTERISTICS

Low Reynolds Number Flow Through Nozzle- Diffuser Elements in Valveless Micropumps

Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

Lecture 18: Microfluidic MEMS, Applications

Analysis of flow characteristics of a cam rotor pump

ME381: FINAL PROJECT REPORT

MEMS Mechanical Fundamentals

Design and Simulation of Valve Less PZT Micropump for Drug Delivery System

Fluid structure interaction dynamic analysis of a mixed-flow waterjet pump

Design and Analysis of Various Microcantilever Shapes for MEMS Based Sensing

874. The squeeze film effect on micro-electromechanical resonators

DESIGN AND FABRICATION OF THE MICRO- ACCELEROMETER USING PIEZOELECTRIC THIN FILMS

PERFORMANCE ENHANCEMENT OF A VALVELESS PUMP DRIVEN BY A NOBLE PIEZOELECTRIC COMPOSITE ACTUATOR

MODELING OF T-SHAPED MICROCANTILEVER RESONATORS. Margarita Narducci, Eduard Figueras, Isabel Gràcia, Luis Fonseca, Joaquin Santander, Carles Cané

Fatigue Crack Analysis on the Bracket of Sanding Nozzle of CRH5 EMU Bogie

Element size effect on the analysis of heavy-duty machine cross-rail Jianhua Wang1,Jianke Chen1,a,Tieneng Guo1 Bin Song 2, Dongliang Guo3

COUPLED FIELD ANALYSIS OF PIEZOELECTRIC CANTILEVER BEAM

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Design and Test of a PZT Wind Generator Excited by Rotary Magnet

Design of a MEMS Capacitive Comb-drive Accelerometer

ANALYSIS AND NUMERICAL MODELLING OF CERAMIC PIEZOELECTRIC BEAM BEHAVIOR UNDER THE EFFECT OF EXTERNAL SOLICITATIONS

Computer Aided Design of Tine of Tuning Fork Densitometer Shuang LIU, Xin-sheng CHE *, Yi-shun ZHANG and Xin-yu-han JI

SUBSTITUTING particle-sensitive check-valves in micropumps

Integration simulation method concerning speed control of ultrasonic motor

EE 5344 Introduction to MEMS CHAPTER 6 Mechanical Sensors. 1. Position Displacement x, θ 2. Velocity, speed Kinematic

Microstructure cantilever beam for current measurement

Design and Simulation of A MEMS Based Horseshoe Shaped Low Current Lorentz Deformable Mirror (LCL-DM).

Theoretical Evaluation of Electroactive Polymer Based Micropump Diaphragm for Air Flow Control

Experimental Study and Numerical Simulation on Steel Plate Girders With Deep Section

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

Finite Element Analysis of Piezoelectric Cantilever

Proceedings MEMS Inertial Switch for Military Applications

Coupled Field Analysis using the ANSYS/Multiphysics Commercial FEA Code

Impacts of Electroosmosis Forces on Surface-Tension- Driven Micro-Pumps

Finite Element Analysis on a Square Canister Piezoelectric Energy Harvester in Asphalt Pavement

FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR

Development of the Screw-driven Motors by Stacked Piezoelectric Actuators

Magneto-Mechanical Modeling and Simulation of MEMS Sensors Based on Electroactive Polymers

Linear Magnetostrictive Models in Comsol

The research on micropumps initially emerged at Stanford

Advances in Valveless Piezoelectric Pump with Cone-shaped Tubes

CAPACITIVE MICRO PRESSURE SENSORS WITH UNDERNEATH READOUT CIRCUIT USING A STANDARD CMOS PROCESS

Analytical Design of Micro Electro Mechanical Systems (MEMS) based Piezoelectric Accelerometer for high g acceleration

NSC E

Module 6: Smart Materials & Smart Structural Control Lecture 33: Piezoelectric & Magnetostrictive Sensors and Actuators. The Lecture Contains:

DEEP UV LITHOGRAPHY VALVELESS MICROPUMP DESIGN AND TEST

Design and Simulation of Micro-cantilever

Curvature of a Cantilever Beam Subjected to an Equi-Biaxial Bending Moment. P. Krulevitch G. C. Johnson

PSD Analysis and Optimization of 2500hp Shale Gas Fracturing Truck Chassis Frame

SIMULATION AND OPTIMIZATION OF MEMS PIEZOELECTRIC ENERGY HARVESTER WITH A NON-TRADITIONAL GEOMETRY

STRUCTURAL ANALYSIS OF A WESTFALL 2800 MIXER, BETA = 0.8 GFS R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

MECH 466. Micro Electromechanical Systems. Laboratory Manual Laboratory #3: Stiction of MEMS and Strength of MEMS Materials

Finite-Element Analysis of Parts Stress State of Tight Joint Assembled by Press Fitting

Microelectromechanical systems (MEMS) have become an increasingly important area of

The Analysis of Aluminium Cantilever Beam with Piezoelectric Material by changing Position of piezo patch over Length of Beam

DESIGN, FABRICATION AND TESTING OF FIXED-VALVE MICRO-PUMPS

Stress Test Based on Planar Flexible Eddy Current Sensor

Single-phase driven ultrasonic motor using two orthogonal bending modes of sandwiching. piezo-ceramic plates

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

Smart Polymer Material as Artificial Muscle Actuator

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Design and characterization of in-plane MEMS yaw rate sensor

Computational Simulation of Dynamic Response of Vehicle Tatra T815 and the Ground

Thermal Damage Improvement of Slider Fixture in Ion Mill Heatless Etching Process by FEM

Parameter identification of a printed circuit board structure using model updating and scanning laser vibrometer measurements

Chapter 5. Vibration Analysis. Workbench - Mechanical Introduction ANSYS, Inc. Proprietary 2009 ANSYS, Inc. All rights reserved.

Optimal Design of Capacitive Micro Cantilever Beam Accelerometer

Fast Biofluid Transport of High Conductive Liquids Using AC Electrothermal Phenomenon, A Study on Substrate Characteristics

Modeling, Simulation and Optimization of the Mechanical Response of Micromechanical Silicon Cantilever: Application to Piezoresistive Force Sensor

A Sample Durability Study of a Circuit Board under Random Vibration and Design Optimization

Vibration and Modal Analysis of Small Induction Motor Yan LI 1, a, Jianmin DU 1, b, Jiakuan XIA 1

Numerical calculations of the thermal deformations of the rectangular minichannel walls

On The Finite Element Modeling Of Turbo Machinery Rotors In Rotor Dynamic Analysis

Modeling and analysis of the electromechanical behavior of surface-bonded piezoelectric actuators using finite element method

Multiple Cracks Effects on Vibration Characteristics of Shaft Beam

The Use of Multiphysics Models in the Design and Simulation of Magnetostrictive Transducers. Dr. Julie Slaughter ETREMA Products, Inc Ames, IA

Finite Element Analysis and Experiment on a Piezoelectric Harvester with Multiple Cantilevers

Natural vibration frequency of classic MEMS structures

A Numerical Study on Static and Dynamic Characteristics of Electromagnetic Air Compressor used in Household Refrigerators

Simulation of a Micro-Scale Out-of-plane Compliant Mechanism

DESIGNING HIGH-PERFORMANCE MICRO-PUMPS BASED ON NO-MOVING-PARTS VALVES

Finite element analysis of hybrid energy harvesting of piezoelectric and electromagnetic

The stiffness tailoring of megawatt wind turbine

SENSORS and TRANSDUCERS

Strength Analysis and Experiment of High Speed Railway Gearbox Bracket

Research Article Apparatus Developments of Ultrasonic Vibration-Assisted Microabrasive Waterjet Polishing

Sensibility Analysis of Inductance Involving an E-core Magnetic Circuit for Non Homogeneous Material

Simulation and Experimental Research on Dynamics of Low-Pressure Rotor System in Turbofan Engine

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Composite Structures- Modeling, FEA, Optimization and Diagnostics

10 Measurement of Acceleration, Vibration and Shock Transducers

Analysis of Stress Distribution in Piezoelectric. MEMS Energy Harvester Using Shaped Cantilever Structure

Validation of High Displacement Piezoelectric Actuator Finite Element Models

This document is a preview generated by EVS

Natural frequency analysis of fluid-conveying pipes in the ADINA system

Transcription:

Journal of Applied Mathematics and Physics, 2014, *, ** Published Online **** 2014 in SciRes. http://www.scirp.org/journal/jamp http://dx.doi.org/10.4236/jamp.2014.***** Using Finite Element Analysis and Experimental Analysis on Vibration of a Piezoelectric Micro Pump Bo-Wun Huang 1, Jung-Ge Tseng 2, Chien-Hua Chang 1, Chen-Yuan Li 3 1 Graduate Institute of Mechatronics Engineering, Cheng Shiu University, Kaohsiung, TAIWAN. 2 Medical Mechatronics Engineering Program, Cheng Shiu University, Kaohsiung, TAIWAN. 3 Department of Mechanical Engineering, Chinese Culture University, Taipei, TAIWAN. Email: huangbw@gcloud.csu.edu.tw, james.tseng@gcloud.csu.edu.tw, master.ca5302@msa.hinet.net, ying.yi@msa.hinet.net Received **** 2014 Copyright 2014 by author(s) and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/ Abstract Due to the rise of biological and MEMS technology in recent years, some micro flow system components have been paid attentions to developed by many investigators. The importance of micro-pumps manufactured is higher than the other part of micro flow system since it is the power source of the entire micro-flow system and responsible for driving working fluid in the microfluidic system. In actual operation, the instability and bad dynamic characteristics of the micro-pump will cause larger fluid flow mobility error, such as transport behavior and response procedures failure, etc., and even damage the microfluidic system. Therefore, to investigate the stability and dynamic characteristics of a micro pump is necessary. The Finite element analysis (FEA), ANSYS Workbench, is employed to analyze the dynamic characteristics of this micro pump, and experiment is also considered in this study. Keywords Component; Micro pump, Finite Element Analysis, Piezoelectric 1. Introduction A micro fluid system driven by fluid system, like the human circulatory system, is the driving force source of the entire micro fluid flow system. And its features is that it can a precision delivery of micro liquidity body, How to cite this paper: Author 1, Author 2 and Author 3 (2014) Paper Title. *********, *, **-**. http://dx.doi.org/10.4236/jamp.2014.*****

such as micro-pumps, micro valves and micro-sensors in the chip to conduct the biochemical reactions, separation and detection, and to increase the fuel injection efficiency by micro-pump delivery. At recently, the application of the miniaturization component is very widely in high precision industry, so miniature pumps will be a key component of indispensable. Conducting research objective prediction, the micro fluid system future is bound to widespread use of its fluid delivery. This system will be through the high-performance micro-pumps provide impetus and accurate delivery flow, so the micro-flow system is also worthy to study. The micro-mechanical piezoelectric pumps are focused to investigate in this work. A diagram of this micro-mechanical piezoelectric pump is In this figure, a thin film, like as the cantilever mechanism, to drive the inlet and outlet valves, and its stability and dynamic characteristics affect the fluid flow accuracy. So to understand the micro pump actuation mechanism and exclude the actuation of the adverse factors, to increase the fluid current accuracy of control and precision density, and the other by understanding, of the future of energy design a decrease unstable phenomena institutions to serve the material and reduce processing costs, improve the overall Precision machining technology is this study aim. For the micro pump system study, Spencer et al [1] investigated the piezoelectric film pump, membrane pump, subsequent research on thin-film micro pump driven pneumatic as Pol et al [2] were found as Figure 1. Some researchers as Zengerle, etc. [3], W.Zhang et al [4], Stemme et al [5] and Benard et al [6], they designed different type micro- pumps, their operating conditions and performance made a big difference. Some studies turned to their attentions to the micro pneumatic pump, such as [7-10]. The outlet valve will dominate the dynamic characteristics of a micro pump. Therefore, the outlet valve is focused to investigate in this micro pump. To simplify, a cantilever beam type is employed to simulate the outlet value of a micro pump, as [10]. This outlet valve of a micro pump is also selected to study in this work. The finite element method, FEM, is employed to analyze the dynamic characteristics of a piezoelectric micro pump. An experimental analysis is also used to identify the dynamic properties accuracy. Figure 1. A diagram of this micro-mechanical piezoelectric pump [12]. 2. Finite Element Analysis The micro pump, Microjet PS31U5 piezoelectric micro pump, is employed to study. According to the literature published [15], the valves material of a micro pump, PDMS material i.e. Poly Dimethyl Siloxane, is used to study in this work. Table 1 shows the material parameters for this PDMS. Analysis software ANSYS Workbench is employed to study the dynamic characteristics of a micro pump. Element type Solid 187 is considered in this investigation to simulate the complex micro pump outlet valves. It is the three-dimensional 10-node entities, each node has x, y, z direction of displacement of the three degrees of freedom, elements have secondary displacement for irregular grid. This element has plasticity, super-elastic stress enhancement, large deformation, large strain characteristics, can also reduce free mesh problems caused by poor accuracy. The material parameters, such as Young's modulus, Poisson's ratio and density, are set as a polydimethyl siloxane (PDMS) for this micro pump valves. Then, these elements will be meshed into very small elements. This mesh process must note the size and shape relations. After generating the grid produced, the boundary conditions of the micro pump valve have been set in this work. Finally, the finite element model can be to analyze and its results must be compared, verify its accuracy and converge analysis. Conversely, if the error is too large, it is necessary to return to pre-treatment part and to check material parameters or boundary conditions, and then * Special description of the title. (dispensable) 2

re-analyzed. Table 1.Table type styles (Table caption is indispensable). 3. Discussion and results Material parameters Young s modulus Unit 1.53MPa Density 1051.3kg/m 3 Poisson Ratio 0.49 This paper studies the dynamic characteristics of piezoelectric micro pump. By using the finite element analysis software ANSYS Workbench, the natural properties, dynamic characteristics of a micro pump can be studied. To make the results accuracy, experimental analysis is also considered in this work. 3.1. Finite Element analysis First, the convergence of results is necessary in finite element analysis. Figure 2 shows the convergence of the first natural frequency for a micro pump. If the number of elements meshed is over than 4463, the first natural frequency will be converged to 18.Hz. Therefore, the 5000 elements meshed are selected to solve in this finite element analysis for this micro pump outlet valve. After the finite element analysis, the dynamic characteristics of micro pump valve can be observed. The natural frequencies and its corresponding mode shapes are found in Figure 3 displays the 1st natural frequency and mode shape in the color contour and displacement vector. In this figure, the largest vibration displacement occurs at the center of valve. That the branches of valve have the largest vibration in out of plane direction at 35.7 Hz is found in second mode. For same reason, it is found that the branches of valve have the largest vibration in plane direction at 35.8 Hz. The torsion mode of the branches of valve can be found. Table 2 shows the natural frequencies of a micro pump valve. Figure 2. The convergence of the first natural frequency of a micro pump outlet valve. (a) color contour Figure 3. The 1st mode shape at 18.1Hz. (b) displacement vector 3

Table 2. Natural frequency of a micro pump valve. mode Natural frequency(hz) 1 18.1 2 35.74 3 35.79 4 77.04 3.2. Experimental analysis The experimental analysis is also considered in this work. An experimental setup is displayed in Figure 4. In this setup, a Laser displacement meter is employed to measure the vibration of the piezoelectric actuator and outlet valve of a micro pump. Figure 5 shows the time response of a piezoelectric actuator of a micro pump. In this figure, the perfect harmonic waves in this time response are found. This wave is excited by the piezoelectric actuator in a micro pump. Both the vibration waves of the piezoelectric actuator and outlet valve in a micro pump are considered to compare. Figure 6 illustrates the time response of an outlet valve of a micro pump. Because the residual vibration of is found as the outlet valve is operating. Therefore, the no perfect harmonic waves of the outlet valve when the piezoelectric actuator excites. However, both the frequencies of waves of the outlet valve and piezoelectric actuator are identical. Frequency response is also considered in this work. Figure 7 shows the frequency response of a piezoelectric actuator of a micro pump. In this figure, the lowest vibration frequency of the piezoelectric actuator is 28 Hz when this actuator is excited. For the outlet valve, the frequency response is also considered as shown in Figure 8. From this figure, the vibration frequency of the outlet valve is also 28 Hz. For both the piezoelectric actuator and outlet valve, the lowest vibration frequencies are identical when the actuator is excited. Figure 4. A photo of the experimental setup. X:29.7561 ms TCapture 1 0.035 m Y:28.34969 mm Capture Real -0.035 0 s 200 ms Figure 5. Time response of a piezoelectric actuator of a micro pump. 4

X:132.1951 ms TCapture 1 2.5E-05 m Y:18.22289 um Capture Real -2.5E-05 0 s 200 ms Figure 6. Time response of an outlet valve of a micro pump. X:28 Hz Y:-33.8 dbm Pwr Spec 1-30 dbm rms Mag (db) -130 0 Hz 1.6 khz Figure 7. Frequency response of a piezoelectric actuator of a micro pump. X:28 Hz Y:-100.627 dbm Pwr Spec 1-90 dbm rms Mag (db) -190 0 Hz 1.6 khz 4. Conclusions Figure 8. Frequency response of an outlet valve of a micro pump. The natural properties of a piezoelectric micro pump have been investigated. The following conclusions can be drawn from this study. (1) Results show that the finite element analysis can be employed to study the natural properties of a micro pump. (2) Because the PDMS simulated is softer than the actual outlet value, the lowest natural frequency of the simulation is lower than the experiment. (3) Although the time responses of the actuator and outlet valve match very well, that the vibration frequency of the actuator is same as the outlet valve in a micro pump when the actuator is excited is found. Acknowledgements 5

The authors would like to thank the National Science Council, Taiwan, for financially supporting this research through Grant NSC 102-2632-E-230-001 -MY3. References [1] Spencer, W.J., Corbett, W.T., Dominguez, L.R. and Shafer, B.D. (1978) An Electronically Controlled Piezoelectric Insulin Pump and Valves. IEEE Trans. Sonics Ultrason, 25, 153-167. [2] Van de Pol, F.C.M., Van Lintel, H.T.G., Elwenspoek, M. and Fluitman, J.H.J. (1990) Thermopneumatic Micro Pump Based on Micro-engineering Techniques. Sensors and Actuators, A:Physical, 21(1-3), 198-202, 1990. [3] Zengerle, R., Ulrich, J., Kluge, S., Richter, M. and Richter, A. (1995) A Bidirectional Silicon Micropump. Sensors and Actuators, A: Physical, 50, 81-86. [4] Zhang, W. and Ahn, C.H. (1996) A Bi-directional Magnetic Micropump on A Silicon Wafer. Proceedings of the IEEE Solid-State Sensor and Actuator Workshop, Hilton Head Island, SC, June 1996, 94-97. [5] Stemme, E. and Stemme, G. (1993) Valveless Diffuser/Nozzle Based Fluid Pump. Sensors and Actuators, A: Physical, 39(2), 159-167. [6] Benard,W.L., Kahn, H., Heuer, A.H. and Huff, M.A. (1997) ATitanium-Nickel Shape Memory Alloy Actuated Micropump. Proceedings of the IEEE Solid-State Sensor and Actuator Workshop, Chicago, IL, June 199, 361-364. [7] Vieider, C., Ohman, O. and Elderstig, H. (1995) A Pneumatically Actuated Micro Valve with a Silicone Rubber Membrane for Integration with Fluid- Handling Systems. Proceedings of the 8th International Conference On Solid-State Sensors And Actuators And Eurosensors IX, 2, June 1995, 284-286. [8] Huff, M.A., Gilbert, J. and Schmidt, M.A. (1993) Flow Characteristics of a Pressure-Balanced Microvalve. Proceedings of the 7th International Conference on Solid State Actuators, Yokohama, June 1993, 98-101. [9] Yanagisawa, K., Kuwano, H. and Tago, A. (1995) Electromagnetically Driven Microvalve. Microsystem Technologies, 2(1), 22-25. [10] Jerman, H. (1994) Electrically-Activated, Normally-Closed Diaphragm Valve. Journal of Micromechanics and Microengineering, 4, 210 216. [11] Olsson, A., Enoksson, P., Stemme, G. and Stemme, E. (1996) A Valveless Planar Pump Isotropically Etched in Silicon, Journal of Micromechanics and Microengineering, 6, 87 91. [12] Microjet Technology Co., Ltd. (2007) CurieJet-Micro Pump. In: Product type PS31U5. [13] Lin L.C. (2005) Numerical Analysis of Piezoelectric Micro Pump. M.S. Thesis, National Taiwan University, Taipei. 6