Portable, Low-cost Proportional Counters for Space, Atmospheric and Ground based Applications

Similar documents
Bubble Detector Characterization for Space Radiation

Radiation Environment and Radiation Dosimetry in the Upper Atmosphere

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

InterComparison for Cosmic-ray with Heavy Ion Beams At NIRS

Space Radiation Dosimetry - Recent Measurements and Future Tasks

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

ISSCREM: International Space Station Cosmic Radiation Exposure Model

Deep Space Test Bed. POC Deep Space Test Bed (DSTB)

Neutron Metrology Activities at CIAE (2009~2010)

THESIS MICRODOSIMETRIC MEASUREMENTS OF SHIELDING EFFECTS FOR IRON PARTICLES AT 500 MEY/NUCLEON INCIDENT UPON ALUMINUM AND POLYETHYLENE

Advacam, Prague, Czech Republic. Nuclear Physics Institute, Czech Academy of Sciences, Prague, Czech Republic

Development of Active Space Radiation Detector, A-DREAMS-2 at NIRS

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

CRaTER Pre-Ship Review (PSR) Instrument Calibration Science Requirements Compliance

Prairie View A&M University Center for Applied Radiation Research

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

PHITS calculation of the radiation field in HIMAC BIO

Simultaneous Investigation of Galactic Cosmic Rays on Aircrafts and on International Space Station

A Predictive Code for ISS Radiation Mission Planning

František SPURNÝ, Iva JADRNÍCKOVÁ. Nuclear Physics Institute Department of Radiation Dosimetry, Academy of Sciences of the Czech Republic, Prague

Radioactivity and Ionizing Radiation

In-Situ Estimation of Cosmic Radiation Exposure During High-Altitude, Long-Distance Commercial Flights

Calculation of Bubble Detector Response Using Data from the Matroshka-R Study

Republic. Sept. 3rd th WRMISS in Budapest 1

Launched April 01, reached Mars Oct. 01. Two-hour circular, polar mapping orbit established by Feb p.m. day/5 a.m. night

Requirements for Space Radiation Dosimetry Walter Schimmerling, Francis A. Cucinotta, and John W. Wilson

MONTE CARLO SIMULATIONS OF SOLID WALLED PROPORTIONAL COUNTERS WITH DIFFERENT SITE SIZE FOR HZE RADIATION

Introduction. Principle of Operation

DESIGN OF NEUTRON DOSE RATE METER FOR RADIATION PROTECTION IN THE EQUIVALENT DOSE

Current and Recent ICRU Activities in Radiation Protection Dosimetry and Measurements

Dose rate measurements of charged and neutral particles in the stratosphere

Measuring dose equivalent in an aviation environment using PIN diodes

CRaTER Science Requirements

Your Partner in Environment Monitoring

Calculation of Cosmic Radiation Exposure of Aircrew: PCAIRE Code

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Evaluation of the New Trapped Proton Model (AP9) at ISS Attitudes. Francis F. Badavi. (NASA Langley Radiation Team)

RADIATION DETECTION AND MEASUREMENT

The Cosmic Ray Telescope for the Effects of Radiation (CRaTER) Investigation for the Lunar Reconnaissance Orbiter

Nuclear Physics and Astrophysics

Particle Energy Loss in Matter

Radionuclide Imaging MII Detection of Nuclear Emission

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Radiation Detection and Measurement

Radiation (Particle) Detection and Measurement


Tritel: 3D Silicon Detector Telescope used for Space Dosimetry. Tamás Pázmándi, Attila Hirn, Sándor Deme, István Apáthy, Antal Csőke, *László Bodnár

Space radiation results obtained with R3D-B2 instrument on Foton M2 satellite in June 2005

SPACE DOSIMETRY WITH A 3D SILICON DETECTOR TELESCOPE

Status of ISS-RAD. Cary Zeitlin, Southwest Research Institute On behalf of the ISS-RAD Team

Radiation Detection and Measurement

Simulation of Radiation Monitors for Future Space Missions

Radiation Dose, Biology & Risk

Introduction to Cosmic Rays Data Analysis Issues. Nicola De Simone INFN and University of Rome Tor Vergata

Absorption and Backscattering ofβrays

Fragmentation and space radioprotection

Solar Particle Effects in Aircrew Dosimetry

ISS-RAD: Charged Particle Detector Calibration and Readiness 20 th WRMISS

Particle Energy Loss in Matter

Theoretical Assessment of Aircrew Exposure to Galactic Cosmic Radiation Using the FLUKA Monte Carlo Code

CRaTER Pre-Environmental Review (I-PER) Science Requirements Update

City University of Hong Kong

ROKAF Weather Wing Lt. Park Inchun Lee Jaewon, Lee Jaejin

IAC-08-A MONTE CARLO SIMULATIONS OF ENERGY LOSSES BY SPACE PROTONS IN THE CRATER DETECTOR

November 2013 analysis of high energy electrons on the Japan Experimental Module (JEM: Kibo)

Radiation Effects on Electronics. Dr. Brock J. LaMeres Associate Professor Electrical & Computer Engineering Montana State University

The PAMELA Satellite Experiment: An Observatory in Space for Particles, Antiparticles and Nuclei in the Cosmic Rays

Development of a Passive Dosimeter for Life Science Experiments in Space (PADLES) in NASDA

Space Radiation Protection during NASA Exploration Class Missions

Solar Particle Events in Aviation and Space. Günther Reitz Insitute of Aerospace Medicine German Aerospace Center, DLR, Cologne, Germany

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Secondary Particles Produced by Hadron Therapy

U.S. Radiation Dose Limits for Astronauts

WHAT IS IONIZING RADIATION

EEE4106Z Radiation Interactions & Detection

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

College Physics B - PHY2054C

11 Gamma Ray Energy and Absorption

Cosmic Rays and the need for heavy payloads

Radiation exposure of personnel during IORT: radiation protection aspects.

Radiation Protection & Radiation Therapy

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

P A M E L A Payload for Antimatter / Matter Exploration and Light-nuclei Astrophysics

Metrological traceability and specific needs in: - IR measurement for radiation protection (RP) - IR measurement for radiotherapy (RT)

8. Application to Fast Neutron Therapy

Passive dosimetry in the Service (Zvezda) module: J.K. Pálfalvi1

ICALEPCS Oct. 6-11, 2013

Results from the PAMELA Space Experiment

Lomonosov Moscow State University. NUCLEON Chemical Composition and Energy Spectra of Cosmic Rays at TeV

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Charged Particle Measurements in Mars Orbit from 2002 to 2006

Dosimetry of ionizing radiation

Determination of the Neutron Component of the Cosmic Radiation Field in Spacecraft using a PADC Neutron Personal Dosemeter

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

A survey of Radiation Hazards & Shields for Space Craft & Habitats

Recent Radiation Monitoring Results: Expedition 10, 11 and STS-114

PHYS 3446 Lecture #12

General Overview of Gas Filled Detectors

Cytogenetic signature of heavy charged particles: impact of LET and track structure

LONG-TERM MONITORING OF THE ONBOARD AIRCRAFT EXPOSURE LEVEL WITH Si-DIODE BASED SPECTROMETER ) F. Spurný (1), Ts. Dachev (2)

Transcription:

Portable, Low-cost Proportional Counters for Space, Atmospheric and Ground based Applications E. R. Benton 1, A. C. Lucas 1, O. I. Causey 1, S. Kodaira 2 and H. Kitamura 2 1 E. V. Benton Radiation Physics Laboratory, Oklahoma State University, USA 2 National Institute of Radiological Sciences, Chiba, Japan 22 nd Workshop on Radiation Monitoring for the ISS 5-7 September 2017, Torino, Italy

Operation of a Proportional Counter amplifer & spectrometer chamber filled gas at known pressure preamp High Voltage Power Supply charged particle enters chamber, collides (ionizes) electrons of fill gas free electrons accelerated toward anode wire, collide with more electrons creating electron avalanche, collected by anode wire. Anode Wire at High Voltage conductive walls of chamber held at ground

ATED Detector Head

Active Tissue Equivalent Dosimeter Scientific Objectives Continuously measure the Linear Energy Transfer (LET) spectra, absorbed dose and dose equivalent as functions of time with ~1 second resolution for a total duration of 6 months. Demonstrate the operational capability of the Active Tissue Equivalent Dosimeter Correlate time resolved data with ISS orbital position, altitude and orientation. Determine average dose and dose equivalent rates from galactic cosmic rays, trapped protons in the South Atlantic Anomaly, and trapped electrons at high latitudes. Compare results with measurements made using other radiation detectors deployed throughout ISS (IV-TEPC, REMs, RAMs, Liulin-4, etc.). Compare results with model calculations (HZETRN/OLTARIS). Analyze operational performance of instrument and identify problems and lessons learned for improvement in next generation.

Active Tissue Equivalent Dosimeter Physical Specifications Dimensions: 25.5 cm 15.8 cm 13.0 cm Mass: 3.25 kg (2.25 kg w/o power cable) Power: <10 Watts Power Source: 120 Vac from ISS inverter Maximum internal voltage: +900 Vdc Operational Period: Continuous for 6 months, with short interruption for sample data download to ground via ISS laptop Data: 32 Gbyte SDRAM card, compatible with ISS laptop

Active Tissue Equivalent Dosimeter Flight Unit CPU & Data Storage Spectrometer Detector head lid w/connectors Detector Head Pulse Shaping Amplifier Module Not Shown: HPVS, Power connector & cable, internal wiring and mounting hardware Power Supply

Active Tissue Equivalent Dosimeter Flight Unit Spectrometer CPU & Data Storage High Voltage Power Supply AC to DC Power Supplies Pulse Shaping Amplifier Module

ATED Block Diagram Symbol indicates ground

ATED Power Distribution Diagram 9

November 2017: Handover ATED flight unit to NASA January 2018: Launch to ISS on SpaceX-14 Delivery to ISS ATED Deployment Active Tissue Equivalent Detector Experiment Chronology remove ATED from soft stowage and transfer to ISS Node 3 placement of ATED in aisle in Node 3 near IV-TEPC connect ATED to ISS power, 120 Vac via ISS AC power inverter switch on ATED Continuous Operation for 1 month intervals Transfer sample data at 1 month intervals switch off ATED remove SDRAM card and insert in ISS laptop transfer selected data files to ISS laptop then transmit to ground remove SDRAM card for ISS laptop and insert in ATED switch on ATED

Active Tissue Equivalent Detector Experiment Chronology (cont.) End of Experiment after 6 months deployment and transfer of ATED to SRAG switch off ATED remove SDRAM card and place in soft stowage for return to ground. insert new SDRAM card in ATED transfer ownership of ATED to SRAG

Deployment near SRAG IV-TEPC in Node 3 The Active Tissue Equivalent Detector will be deployed in Node 3 near the IV-TEPC. Images courtesy of Kerry Lee, NASA SRAG

ATED Hardware Update In June 2017, ATED flight unit was tested in heavy ion beams at the HIMAC heavy ion accelerator in Chiba Japan: 150 MeV/n He, 250 MeV/n C, 490 MeV/n Si, 500 MeV/n Fe, Beams represent important components of space radiation environment in LEO. Calibration of ATED as function of lineal energy ATED EMI testing carried out at JSC, 26 June 2017 ATED electrical compatibility testing carried out at JSC, 27 June 2017

ATED during HIMAC Testing/Calibration 14

Lineal Energy Fluence Spectrum from HIMAC Exposures 1.2 y * D(y) (Normalized) 1.0 500 MeV Fe 490 MeV Si 150 MeV He 490 MeV C 0.8 0.6 0.4 0.2 0.0 100 101 102 y (kev/ m) 103

Proportional Counters for use aboard Aircraft Access to the atmosphere, especially aviation altitudes, is orders of magnitude cheaper and more common that axis to space Dosimetric data available from space is far more abundant and of better quality than dosimetric data from aircraft Debate about the risks for ionizing radiation exposure to aircrew and frequent flyers, as well as to avionics, remains controversial and has not been adequately addressed...in part due to a lack of systematic, high quality measurements Planning to flight test current version on NASA DC-8, UAVs, and other aircraft starting in March 2018. Target markets: Commercial jetliners, business jets (routinely fly at higher altitudes than commercial jetliners), high altitude balloon missions.

Neutron Field/Aviation Applications Proportional Counter with Aluminum and Higher Z Ionization Cavities

Normalized Count and Dose Spectra from Tissue Equivalent and Aluminum Proportional Counters exposed at LANSCE 80000 70000 60000 50000 Millions 120 100 80 N(h) 40000 30000 20000 10000 0 0.1 10 1000 kev/micron in tissue N(h)*h 60 40 20 0 0.1 10 1000 kev/micron in tissue AL counts Acrylic x 0.012 AL Dose X62 Acrylic Dose Greater number of counts in Acrylic vs. Al cavities Higher LET in Al vs. Acrylic cavities

TEPCs for use in Proton and Carbon Beam Therapy Proton and Carbon Radiotherapy beams possess higher LET and RBE than do x-ray and electron radiotherapy beams...yet ionization chambers are still used in calibration for all of them. Microdosimeters such as Tissue Equivalent Proportional Counters are an alternative that provides LET and thus RBE information in addition to absorbed dose.

Conclusions and Future Work Using acrylic ionization cavity since more practical than A-150 tissue equivalent plastic Initial application will likely be in aviation/air crew monitoring lighter weight (semi-permanent pressurization) lower power ARM microcontroller-based spectrometer Continuing development optimized for neutron monitoring multiple ionization cavities of different Z materials charged particle/neutron discrimination by surrounding cavity with anticoincidence plastic scintillator layers Developing parallel plate/end-on cylindrical version for use in proton and heavy ion cancer therapy applications Make available commercially at reasonable cost

Thank you for your Attention

TEPC Response to Energetic Protons 1.2 0.8 0.6 1.2 0.4 87 MeV protons 0.2 0.0 0.01 0.1 1 10 100 y (kev/ m) 1.2 y D(y) (normalized units) 162 MeV protons 1.0 1.0 0.8 0.6 0.4 0.2 0.0 0.01 0.8 0.1 1 y (kev/ m) 0.6 A-150 Nylon Acrylic Polystyrene Polyethylene 0.4 0.2 0.0 0.01 y D(y) (normalized units) y D(y) (normalized units) 222 MeV protons 1.0 0.1 1 y (kev/ m) 10 100 10 100

Exposures of Polystyrene STEPC to 490 MeV/n 28 Si beams at HIMAC: Raw, Lineal Energy (Y), and LET Spectra 1.1 1.0 0.9 0.8 490 MeV/n Si, HIMAC 6/2011, Polystyrene STEPC counts Y LET Arbitrary Units 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 50 100 150 (kev/µm)

Average Lineal Energy 1.2 1.0 H He C Si Ar Fe Frequency Averaged Lineal Energy y D(y) (normalized units) 0.8 0.6 0.4 y F = 0 y f ( y) dy y F = Dose Averaged y= y max y= 0 y= y max y= 0 y f ( y) f ( y) 0.2 Lineal Energy 0.0 0.01 0.1 1 10 100 1000 222 MeV Protons 162 MeV Protons 87 MeV Protons Helium Carbon Silicon Argon Iron y (kev/ m) y D = 1 y F 0 y 2 f ( y) dy y D = y= y max y= 0 y= y max y= 0 y 2 f ( y) y f ( y)

y d (kev/µm) 300 250 200 150 100 Dose Averaged Lineal Energies Theoretical A-150 Experiment Nylon Experiment Acrylic Experiment Polystyrene Experiment Polyethylene Experiment Average of Plastics Simulation ICRU Muscle Simulation Si Ar Fe 50 0 H He C 0.1 1 10 100 1000 LET (kev/µm) No appreciable difference between different plastics and tissue Collums et al., NIM B 333 69-72.