Detection of Explosives and Other Illicit Materials by Nanosecond Neutron Analysis

Similar documents
Using Neutron Generator with APT/NNA for Detection of Explosives

Concept of a Combined Device for Localization and Identification of Explosives

Principles and Applications of Neutron Based Inspection Techniques. Tsahi Gozani Rapiscan Laboratories 520Almanor Ave, Sunnyvale, CA

Simulation of nonorganic scintillation detector response for the problems of active interrogation by tagged neutron technology

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

New Scintillators for the Border Monitoring Equipment

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

Status Report on the detection of illicit materials in cargo containers by using neutron beams.

1 of :32

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

Pulsed Neutron Interrogation Test Assembly - PUNITA

The Use of Neutron Generators for the Detection of Illicit Materials in the Sea Transportation System

AUTOMATED TEMPLATE MATCHING METHOD FOR NMIS AT THE Y-12 NATIONAL SECURITY COMPLEX

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

NEUTRON GENERATORS AND DAQ SYSTEMS FOR TAGGED NEUTRON TECHNOLOGY

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

Acquisition of neutron-induced gamma signatures of chemical agents

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

D) g. 2. In which pair do the particles have approximately the same mass?

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

MCNP Simulations of Fast Neutron Scattering by Various Elements and their Compounds in View of Elaboration of a Single Shot Inspection System

Gamma-Spectrum Generator

NEUTRON RADIOGRAPHY OF CARGO CONTAINERS USING 2.5 MEV TAGGED NEUTRONS

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

A. Element 1. The number of protons and neutrons of an atom.

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

arxiv: v1 [physics.ins-det] 29 Jun 2011

Chemistry: The Study of Change Chang & Goldsby 12 th edition

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Measurements of the gamma-quanta angular distributions emitted from neutron inelastic scattering on 28 Si

The Neutronic Check Point: fast neutron transmission measurements to detect explosives in vehicles.

The Use of Neutron Generators for the Detection of Hidden Explosives and Illicit Materials. Giancarlo Nebbia

Pulsed NeutroN technology: exploring New dimensions fastgradetm logging NeutroN tool P Cu Si Ni Fe NEUTRON TECHNOLOGY

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

n+a n +A *, A * γ+a, (2)

The EURITRACK Project: Status of a Tagged Neutron Inspection System for Cargo Containers

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

Explosives Detection and Identification by PGNAA

How many grams of sodium metal is required to completely react with 2545 grams of chlorine gas?

Half Yearly Exam 2015

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Preparatory experiments for cold-neutron induced fission studies at IKI

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Gamma signatures of the C-BORD Tagged Neutron Inspection System

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

ULIS a portable neutron device for explosives and chemicals detection

How many grams of sodium metal is required to completely react with 2545 grams of chlorine gas?

Unit 2: Atomic Structure Additional Practice

Powerful Nanosecond Single- Shot Technique for Detection of Illicit Materials and Explosives

FISSILE MATERIALS DETECTION VIA NEUTRON DIFFERENTIAL DIE-AWAY TECHNIQUE

Using Fast Neutrons to Detect Explosives and Illicit Materials

Chapter 2: Atoms and the Periodic Table

Unit 3 Atomic Structure

Determination of the boron content in polyethylene samples using the reactor Orphée

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

All atoms of an element must have the same number of protons but not neutrons.

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Recent improvements in on-site detection and identification of radioactive and nuclear material

3.1 Classification of Matter. Copyright 2009 by Pearson Education, Inc.

Neutronics Experiments for ITER at JAERI/FNS

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

(PHENS) for Active Diagnostics of Radiation Environment in Spacecraft

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Overview of X-Ray Fluorescence Analysis

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

Chapter 3 Atoms and Elements

Unit 2. Atoms, Molecules, and Ions

Chapter 2 Atoms and Elements

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

NEUTRON TECHNOLOGIES (PAPER II)

Atomic Structure Practice Questions

DEVELOPMENT OF NEUTRON INTERROGATION TECHNIQUES TO DETECT DANGEROUS SUBSTANCES

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

GENERAL CHEMISTRY FOR INTEGRATED SCIENCE 1 STUDY NOTES CHAPTER ONE

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

Chapter 2: Atoms and the Periodic Table

Chapter 2 Atoms and Elements. 2.4 The Atom

Chemistry: A Molecular Approach, 2e (Tro) Chapter 2 Atoms and Elements. Multiple Choice Questions

Chemistry 9 Weeks Exam Review Guide

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

First tests of the big volume ultra low background gamma spectrometer

arxiv: v2 [physics.ins-det] 8 Feb 2013

Teacher Workbooks. Science and Nature Series. Atomic Structure, Electron Configuration, Classifying Matter and Nuclear Chemistry, Vol.

An introduction to Neutron Resonance Densitometry (Short Summary)

INSTRUMENTAL TECHNIQUE FOR THE DETECTION AND IDENTIFICATION OF RADIOACTIVE, FISSILE AND EXTRA HAZARDOUS SUBSTANCES

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Name Honors Chemistry: Atoms, protons, electrons, neutrons, and the Periodic Table

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Part A. Answer all questions in this part.

Transcription:

1 Detection of Explosives and Other Illicit Materials by Nanosecond Neutron Analysis A.V. Evsenin 1, I.Yu. Gorshkov 2, A.V. Kuznetsov 1, O.I. Osetrov 1, D.N. Vakhtin 1 1 V.G. Khlopin Radium Institute (KRI), Saint-Petersburg, Russia 2 Applied Physics Science and Technology Center (APSTEC), Saint-Petersburg, Russia Email contact: apl@khlopin.ru, info@apstec.ru Abstract. Experimental results in the detection of explosive and other hazardous materials by Nanosecond Neutron Analysis (NNA) technique are presented. The detecting device SENNA is based on a portable DT neutron generator with built-in segmented detector of associated α-particles, detectors of γ-rays, and fast data collection electronics. Experimental measurement of the response functions of NaI, BGO, and LaBr 3 -based γ-ray detectors to pure chemical elements is described. Examples of using SENNA to detect explosives in luggage and UXO on a conveyer belt and in the ground are discussed. 1. Introduction Neutron-based methods of non-destructive analysis are sometimes the only tool to determine the nature of the material that is located behind thick barriers (e.g. a UXO in the ground) or is surrounded by other materials (e.g. in cargo containers) [1]. Among methods that provide the most complete information about the chemical composition of the inspected material is a group of neutron in, gamma out methods: TNA, FNA, PFTNA, and NNA/APT. The main advantages of neutron in, gamma out techniques over conventional methods are: 1. High selectivity: chemical composition of the substance can be determined (unlike X- rays or QR-based methods). 2. High penetrating ability of neutrons and γ-rays (much higher than that of X-rays). 3. Sealed containers can be inspected (unlike vapor/trace detectors). 4. Fully automatic data analysis and decision-making of YES/NO type are possible (unlike with X-rays). The most powerful of these methods is Nanosecond Neutron Analysis / Associated Particle Technique (NNA/APT). 2. Nanosecond Neutron Analysis / Associated Particle Technique (NNA/APT) NNA/APT is a non-destructive analysis method that allows one to obtain a 3D distribution of chemical elements (isotopes) in the inspected volume [2]. Concentrations of different chemical elements are obtained from the analysis of energy spectra of secondary γ-rays that are induced at different locations ( voxels ) of the inspected volume by 14 MeV neutrons. The neutrons are produced in a DT neutron generator equipped with a position-sensitive detector of α-particles that accompany neutrons in the reaction d + t = α + n. The location of the material that produced the given γ-quantum is determined from the analysis of γ-α coincidences [2]. Advantages of NNA over other neutron-gamma methods are: a) very good effect-to-background ratio (unlike FNA and PFTNA); b) sensitivity to almost all chemical elements (unlike TNA); c) position sensitivity: the mass of the object can be determined.

2 2 15 Counts / 1keV 5 8 6 4 all γ-rays detected in LaBr 3 γ-rays left after NNA coincidence analysis 2 2 3 4 5 6 7 8 E γ [kev] FIG. 1. Experimental energy spectra of γ-rays obtained in a 15 minute-long measurement with 3g of sulfur powder in 44g plastic box. Top line is the spectrum of all γ-rays detected by the LaBr 3 detector. Bottom spectrum contains γ-rays selected from all events by the coincidence and TOF analyses. The improvement of the quality of the γ-ray spectra that can be achieved in NNA/APT is demonstrated on FIG. 1. The top spectrum contains all γ-rays detected in a LaBr 3 -based detector during 15 minute-long irradiation of 3g sulfur powder in a 44g plastic box. The bottom spectrum is what remains after the proper coincidence and TOF analysis is carried out: the γ-rays that come from the sample are retained, while most of the γ-rays that originate from other sources (reactions of neutrons with the surrounding materials, reactions of neutrons with the γ-ray detector itself, etc.) are suppressed. The suppression of the background achieved in this case is over 4 orders of magnitude. Any attempt to extract the component related to the sample directly from the top (total) spectrum would fail, since the surrounding materials may contain the unknown amount of the same elements as the sample itself. 2.1. NNA/APT hardware The central piece of any NNA/APT device is a DT neutron generator with built-in detector of associated α-particles. We are currently using ING-27 portable neutron generators equipped with 9-pixel, 36-pixel, or 144-pixel silicon-based α-detectors. These very compact and lightweight neutron generators typically produce (2 5) 1 7 n/s (1 8 n/s maximum), and the lifetime of the sealed neutron tube is about hours. Depending on the α-detector type, the share of the neutrons tagged by α-particles may be from 1% to 5%. Several types of γ-ray detectors are used in different devices: NaI(Tl), BGO, and LaBr 3 scintillation crystals. NaI(Tl) crystals are the largest and the cheapest of them all, but they

3 cannot work at high counting rates due to a large number of low-amplitude pulses that affect the detector s energy resolution. BGO crystals have the highest density (and hence efficiency), and are optimal for use in compact devices to detect explosives and other substances that have limited number of constituting elements (e.g. in explosives they are carbon, nitrogen, and oxygen, all of which have high energy peaks in their γ-spectra that can be well resolved by a BGO-based detector). Detectors of γ-rays based on LaBr 3 crystals have excellent energy and time resolution, and are capable of detecting most chemical elements that have low energy lines in their γ-spectra. The price of these crystals is however notably higher than that of NaI and BGO. The compact data acquisition system (DAQ) that was specially designed for use in NNA/APT devices contains all the components needed to operate the device: 1. detector power supplies; 2. spectrometers of γ-rays; 3. α-particle detection electronics; 4. coincidence analysis module. The DAQ boards are build right into the respective detectors, and each is connected with the coincidence module by a single cable. The DAQ exists in two versions: Ultra-compact DAQ for servicing one neutron generator with any α-detector and up to 4 detectors of γ-rays. Universal DAQ for servicing multiple neutron generators with α-detectors and multiple detectors of γ-rays (up to 4 devices in any combination). 2.2. Data analysis and decision-making in NNA/APT NNA/APT suppresses the background (everything unrelated to the substance of interest) by a factor of or more (see FIG. 1). Still, the remaining spectra contain noise coming from several sources: statistical, parasitic material, accidental coincidences. Direct analysis of these spectra by some image-recognition technique would inevitably result in analyzing a lot of irrelevant information contained in the noise. Suppression of this noise requires a multi-stage data analysis: Construction of energy spectra from the raw data. Determining elemental concentrations by fitting energy spectra of γ-rays with response functions to individual elements. Automatic decision-making based on the analysis of elemental concentrations (and any other available information). At the first stage the raw event-by event data are analyzed to construct energy spectra of γ-rays for each voxel or the inspected volume. This requires energy and time calibrations that are done automatically using the same experimental data that is being analyzed. Then, elemental concentrations are determined from spectral regression using modified PLS (Projection to Latent Structures) algorithm. It allow one to fit the spectra collected with poor statistics with more than 3 components that are energy spectra measured for pure chemical elements.

4 At the last stage the resulting elemental concentrations and their error bars are fed into a fuzzy logic decision-making procedure that provides an ALARM / NO_ALARM type answer. If measurement time is used as one of the analyzed parameters, the system can decide to continue the measurement until the desired reliability of the result is reached. 3. Experimental results Conventional (industrial or military) explosives in luggage and other relatively small packages can be detected by analyzing ratios between carbon, oxygen and nitrogen. An experiment with SENNA IV device [3] was carried out to determine the possibility to detect explosives in suitcases. Chemical imitators of RDX and ammonium nitrate weighting over 2g were placed in a suitcase among other benign objects typically found in suitcases: books, cotton and woolen clothing, drinks, consumer electronics, toothpaste, deodorants, cocoa butter etc. (see left photo on FIG. 2). The suitcase was rotated to ensure that the sample was inside the sensitive volume of the device. FIG. 2 shows an example of the measurement, in which the explosive imitator was detected in the voxel corresponding to the central pixel of the α-detector at depth 1cm from the front surface of the suitcase. In these tests all imitators were successfully detected. No false alarms were registered neither in measurements without samples, nor in the voxels that contained benign materials. Another possible application of NNA/APT is identification of UXO, which may either be empty, or contain conventional explosive charges, poisonous chemicals, or both. Depending on the scenario the UXO may be inspected either at a disposal facility or directly where it was discovered e.g. lying in the ground at a construction site. When the UXO is inspected at a disposal facility in controlled environment (e.g. on a conveyer belt), a limited number of chemical elements that may be found in different types of UXO are to be taken into account: Fe, C, N, O, H, S, Cl, As, and P. FIG. 2. Automatic detection of explosives imitators in a suitcase by SENNA IV device. Photo on the left: the sample in the suitcase. Photo in the center: inspection geometry. Screenshot on the right: the result automatically obtained by the device.

5 The feasibility of using NNA/APT for identification of UXO was experimentally tested, using the device consisting of a neutron generator with 36-pixel detector of associated α-particles, and three detectors of γ-rays based on 3 3 BGO crystals. The imitators of UXO that we used in the experiments are listed in TABLE 1. TABLE 1. THE IMITATORS OF UXO USED IN THE EXPERIMENTS. Type Composition of the actual UXO Composition of the imitator 5% mustard gas + 5% Lewisite arsenic oxide, sulfur, salt, graphite, water explosive Melamine, water, graphite red diphenylcyanoarsine + explosive arsenic oxide, melamine, water, graphite Prussic acid Melamine, graphite The mixtures of the imitating substances were enclosed into 1cm-thick iron containers. The detectors of γ-rays were placed right under the inspected imitator and were shielded from the direct flux of 14 MeV neutrons by a composite shielding (borated polyethylene + lead). The inspection time was 1 minute, and each measurement was repeated times in order to check the reliability of the results. The γ-ray spectrum obtained in each measurement was fitted with the response functions of the device to individual chemical elements, and the resulting elemental concentrations were represented on 2D plots with axes corresponding to different chemical elements. Examples of such plots for red and imitators are shown on FIG. 3. Each small dot represents the result of a single 1 minute-long measurement. The color of the dot corresponds to the name of the imitator. Large colored symbols show the calculated location of the corresponding imitator. The device was able to correctly identify the imitator in % cases by comparing the distances (in four dimensions: O, S, N, As) from the experimental dot to the expected locations of all imitators and choosing the closest one. Such a simple data analysis procedure worked, because the system had a very limited number of classification options. However, when inspecting a totally unknown UXO that is lying on the ground, one has to additionally take into account a large number of chemical elements that can be found in the soil around the UXO: H, O, Si, Al, Ca, Mg, K, Na, Ti, and many others. Practically speaking over 3 abundant chemical elements must be taken into account, since all of them may contribute to the measured spectrum of γ-rays. FIG. 3. Distribution of measurements with red and UXO imitators in coordinates N-O (left), S-O (center), and As-O (right). Large symbols show the positions of the red,,, and imitators calculated from their known chemical composition.

6 The energy resolution of BGO-based detectors of γ-rays is too rough to allow the spectral fitting procedure to reliably extract contributions of over 3 chemical elements from the experimental spectrum that is usually measured with poor statistics. Among other available types of γ-ray detectors LaBr 3 scintillation crystals have the best energy resolution, time resolution, and efficiency. 3.1. Response functions for different types of γ-ray detectors In order to effectively use the spectral fitting procedure one must have correct response functions to individual chemical elements. The response functions used so far for BGO-based detectors were calculated using MCNP 1 code. For such elements as carbon, nitrogen, oxygen, iron, aluminum and others that are important for detection of explosives the results given by MCNP coincide with the experiment. For other elements (e.g. sulfur) the MCNP results are wrong. The LaBr 3 -based detectors produce spectra with much more detailed peak structures, and the exact knowledge of the response functions becomes critical. Experiments were carried out to measure the response functions of the detectors based on NaI, BGO, and LaBr 3 crystals to the most abundant chemical elements. The experimental setup consisted of a neutron generator with a narrow (24 o opening angle) beam of tagged neutrons, and three detectors of γ-rays ( 3 3 LaBr 3, 3 3 BGO, and 6 4 NaI) located at different sides from of the sample. Samples were pure chemical elements (where practical), oxides, hydroxides, or acids placed in lightweight plastic containers. The masses of the samples were such that each contained 3g of the pure element of interest. Duration of measurements with each sample was 1 hour, intensity of the neutron generator was 2 1 7 n/s. Yield [a.u.] 1.6 1.4 1.2 1..8.6.4.2 OXYGEN MCNP experiment Yield [a.u.] 1.8 1.6 1.4 1.2 1..8.6.4.2 SULFUR MCNP experiment 2 3 4 5 6 7 8 E γ [kev] FIG. 4. Experimental and calculated (MCNP) response functions of LaBr 3 -based γ-ray detector to oxygen and sulfur. 1 MCNP A General Monte Carlo N-Particle Transport Code, Version 5, LA-UR-3-1987.

7 Counts [a.u.] 5 4 3 2 1 4 3 2 1 LaBr 3 BGO 2 3 4 5 6 E γ [kev] C N O F Na Mg Al Si P S Cl K Ca Ti Cr Mn Fe Ni Cu Zn As Br Cd Sn Pb FIG. 5. Response functions for BGO-based and LaBr 3 -based detectors. Experimental data were analyzed to produce spectra of γ-rays for the 3D voxel containing the sample. These spectra were normalized to the actual number of the detected α-particles to get rid of the variations of the intensity of the neutron generator. Pre-measured contributions from the background, plastic container, and parasitic elements (e.g. oxygen in oxides) were then subtracted from the spectra. As one can see from FIG. 4, the quality of the MCNP simulation is different for different elements. While for oxygen the response function calculated by MCNP is very close to the experimental one, for sulfur the standard MCNP5 cross-section library describing (n,n γ) reactions is definitely wrong. The superior energy resolution and high light output of γ-ray detectors based on LaBr 3 crystals allow one to get response functions with rich peak structure and in wide dynamic range in our case from kev to 1 MeV. Response functions measured with BGO and LaBr 3 are shown at FIG. 5. As a result of these measurements, libraries of experimental response functions of BGO and LaBr 3 -based detectors were created. These libraries were used in the analysis of the spectra measured for UXO imitators (listed in TABLE 1) lying on the surface of sand. In this experiment the masses of the UXO constituents were determined, and then compared to the known chemical composition of the imitators (FIG. 6).

8 2 2 15 5 CARBON NITROGEN 15 5 Mass, grams 2 15 5 4 3 2 SULFUR CHLORINE ARSENIC Solid symbols: experiment Open symbols: real mass Yellow: Mustard gas + Lewisite Brown: Prussic acid Black: Explosive 2 15 5 FIG. 6. Experimental determination of masses of chemical elements in UXO from spectra of γ-rays measured with LaBr 3 detector. One can see, that masses of carbon, nitrogen, sulfur, arsenic, and chlorine were reproduced with good precision. The mass of oxygen cannot be used for identification since the unknown amount of oxygen from sand contributes to the measured spectra. 4. Conclusions Devices based on Nanosecond Neutron Analysis have been successfully used to automatically identify concealed explosives, hazardous chemicals, and UXO both on a conveyer and in the ground. Superior characteristics of the LaBr 3 -based γ-ray detector make it a perfect candidate for use in NNA/APT devices, the only drawback being its high price. 5. References [1]. GOZANI T., The role of neutron based inspection techniques in the post 9/11/1 era, Nucl. Instr.and Meth. B, vol. 213, pp.46-463 (24) [2]. EVSENIN A.V. et al., Detection of hidden explosives by nanosecond neutron analysis technique, Detection of bulk explosives: advanced techniques against terrorism (Proc. of the NATO ARW #97992 St.-Petersburg, Russia, 23), (H.SCHUBERT, A.KUZNETSOV, Eds.), Kluwer Academic Publishers, (24) p. 89. [3]. EVSENIN A.V., et al., Detection of Dirty Bombs Using Nanosecond Neutron Analysis (NNA) Technique, Prevention, Detection and Response to Nuclear and Radiological Threats (Proc. NATO ARW, Erevan, 26), (APIKYAN, S., DIAMOND D., WAY R., Eds.), Springer, (28) 125-14.