New consensus ozone cross-section value for troposhperic ozone monitoring

Similar documents
Ozone cross-sections (Hartley band) Progress towards new accurate values

Improving the accuracy of NO 2 and Ozone monitoring

CCQM-P28: An international comparison of ground-level ozone reference standards

Calibration strategies for FTIR and other IRIS instruments for accurate δ 13 C and δ 18 O measurements of CO 2 in air

Liaison with the World Meteorological Organization (WMO) Isabelle Rüedi

Bureau International des Poids et Mesures Comparison of ozone reference standards of the CHMI and the BIPM

Bureau International des Poids et Mesures

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NIM, 2008

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with UBA, 2007

Bureau International des Poids et Mesures

High spectral resolution ozone absorption cross-sections: Part I. Measurements, data analysis and comparison with previous measurements around 293 K.

Bureau International des Poids et Mesures

Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NPL, (May 2013)

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NPL, 2008

Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NMISA, (July 2012)

Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with CHMI, (September 2017)

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with JRC, 2008

Preparation of nitrous oxide (N 2 O) in air standard being traceable to SI by gravimetric method

Ozone UV Spectroscopy. II. Absorption Cross-Sections and Temperature Dependence

Measuring isotopes accurately for a safer, healthier and sustainable world

CCM short note on the dissemination process after the proposed redefinition of the kilogram

Final report, Ongoing Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with NMC, A*STAR, (December 2010)

Statement of SAG-Ozone

Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure. Robert Wielgosz. Bureau International des Poids et Mesures

A new photometric ozone reference in the Huggins bands: the absolute ozone absorption cross section at the 325 nm HeCd laser wavelength

Introduction to Electromagnetic Radiation and Radiative Transfer

Measurement method for the proficiency testing program

European Association of National Metrology Institutes

A critical review of the absorption cross-sections of O 3 and NO 2 in the ultraviolet and visible

II. WAVELENGTH SELECTION

RECOMMENDATION 1 (CI-2002): Revision of the practical realization of the definition of the metre

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation

Experiment #9. Atomic Emission Spectroscopy

Preparation of nitrous oxide in air standard (320 nmol/mol) for CCQM-K68

Aerosol Composition and Radiative Properties

Experiment 24: Spectroscopy

Measurement & Uncertainty - Basic concept and its application

Effect of the Ozone Cross section in Total Ozone in Dobson and Brewer Algorithms

Comparison of new characterized bandpass and wavelengths of Dobsons

Long-term time-series of height-resolved ozone for nadir-uv spectrometers: CCI and beyond

HARP Assessment of Uncertainty

Comparability and Traceability Point of view from a metrological institute

Rolling Review of Requirements Application area: Atmospheric chemistry

Introduction. Martin J. T. Milton. Director of the BIPM. Monday 27th June 2016

Traceable UV-Vis Reference Materials

Ozone: Earth s shield from UV radiation

EMISSION SPECTROSCOPY

6 Terahertz-Wave Propagation Model

Progress Towards an Absolute Calibration of Lunar Irradiance at Reflected Solar Wavelengths

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

Tropospheric trace gas concentrations using infrared spectroscopy from space. Meeting report

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

3 - Atomic Absorption Spectroscopy

The Impact of Using Different Ozone Cross Sections on Ozone Profile Retrievals from OMI UV Measurements

Topic 3: Periodic Trends and Atomic Spectroscopy

Spectrum of Radiation. Importance of Radiation Transfer. Radiation Intensity and Wavelength. Lecture 3: Atmospheric Radiative Transfer and Climate

Infrared Thermometer Calibration A Complete Guide

UV3000. Accurate, precise, and portable ambient gas point analyzer

Lecture 3: Atmospheric Radiative Transfer and Climate

1. The most important aspects of the quantum theory.

Talanta 86 (2011) Contents lists available at ScienceDirect. Talanta. j ourna l ho me page:

ASTRO Fall 2012 LAB #7: The Electromagnetic Spectrum

STRATOSPHERIC TEMPERATURE MONITORING USING A COLLOCATED IR/ GPSRO DATASET

(Figure 2) Science coursework

Measurement & Uncertainty - Concept and its application

Establishment of a Traceability Chain in Metrology for Materials

Determination of atmospheric temperature, far- infrared hyperspectral measurements

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Aircraft and satellite hyperspectral measurements investigating the radiative impact of atmospheric water vapour

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Topic 2.11 ANALYTICAL TECHNIQUES. High Resolution Mass Spectrometry Infra-red Spectroscopy

Calibration and Purity Assessment in Chemical Analysis

The Hydrogen Spectrum

ISA QATAR : 90 th Seminar

EMRP JRP SIB-05. NewKILO. Developing a practical means of disseminating the redefined kilogram (June 2012 May 2015) Stuart Davidson, NPL, UK

f N 2 O* + M N 2 O + M

A guide to expression of uncertainty of measurements QA4EO-QAEO-GEN-DQK-006

Spectroscopic Applications of Quantum Cascade Lasers

CCT/10-21 Extrapolation of the ITS-90 down to the boiling point of nitrogen from the triple point of argon

Impact of different spectroscopic datasets on CH 4 retrievals from Jungfraujoch FTIR spectra

Choosing the proper technique for measuring the particle light absorption

Introduction to metrology

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

Questions on Instrumental Methods of Analysis

CHAPTER 1. MEASURES OF ATMOSPHERIC COMPOSITION

Quantum Chemistry. NC State University. Lecture 5. The electronic structure of molecules Absorption spectroscopy Fluorescence spectroscopy

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI

NPL, India activity related to water as per the need of the country

NO X AT CAPE VERDE (CVO) Chris Reed, Katie Read, Luis Mendes, James Lee, Lucy Carpenter

2B Technologies, Inc. An InDevR Company

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Remote Measurement of Tropospheric NO 2 by a Dual MAX-DOAS over Guangzhou During the 2008 PRD Campaign

Final report, On-going Key Comparison BIPM.QM-K1, Ozone at ambient level, comparison with DMDM, July 2015

Spectrophotometry. Introduction

UV Quality Assurance. Dark Current Correction

2. Discrete means unique, that other states don t overlap it. 3. Electrons in the outer electron shells have greater potential energy.

How do you really know what the temperature is? Michael de Podesta

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

wavelength standards Jack Stone National Institute of Standards and Technology

Transcription:

New consensus ozone cross-section value for troposhperic ozone monitoring NEW NEW CROSS-SECTION CONSENSUS VALUE TROPOSPHERIC MONITORING 3

CROSS-SECTION Ozone is mainly measured by light absorption using the Beer-Lambert law Ozone is normally measured in air (ambient or synthetic), with typical mole fractions around 30 nmol mol - 1 (clean air) to 100 nmol mol -1 (poluted troposphere) I 0 is the light intensity before absorption (or without ozone). It is a measured quantity. I 0 L I 0 e (-nσl) n is the number concentration of ozone (molecules cm -3 ). It is usually converted to mole fractions (in air) using the Ideal Gas Law. L is the light absorption path length. In many measurements, this is considered as being equal to the length of the gas cell. This is an approximation which may be corrected for most accurate measurements. σσ is the absorption cross-section at the wavelength of the input light. Its value needs to be measured independently, and this was done by many groups since 1930. A consensus value based on past measurements is the best way to ensure comparability of world-wide measurements.

CROSS-SECTION Ozone has a strong absorption peak in the UV σσ(253.65) Low pressure mercury lamps emit light with a strong and sharp peak at 253.64 nm Hartley band Spectral relative irradiance λλ/nm σσ(253.65) James Norris and Arnauld Bass with the first SRP in 1982 It was chosen as light source in the first Standard Reference Photometer built at NIST in 1982 NIST SRP The ozone absorption cross-section value measured by Hearn in 1961 was chosen, and is still being used in most ozone UV photometers Hearn, A. G. (1961). "The absorption of ozone in the ultra-violet and visible regions of the spectrum." Proceedings of the Physical Society 78: 932-940.

CROSS-SECTION Cross-section measurements require PURE ozone Light beam I 0 Ozone almost always produced by discharge in oxygen and trapped in liquid phase Sample of pure ozone L opt (P,T) I 1 T R I σ O3 = ln( ) L P Na I opt O3 0 Pressure : pressure sensors measure total pressure P T, not partial pressure P O3 = x(o 3 ) P T Purity = assessment of impurities - condensables x C - non-condensables x NC 1 T R I σ O3 = ln( ) L P x(o ) Na I opt T 3 0 1 T R I σ O3 = ln( ) Lopt Na I0 PT 1 xnc xc i i More accurate equation

MONITORING Global tropospheric ozone monitoring Because of its detrimental effects on public health and the environment, ozone is one of the most monitored compound at ground level. Global GAW stations Ozone WCC (EMPA) Local, national, regional and even global networks rely on proper calibrations. Most of them are ultimately treaceable to an ozone Standard Reference Photometer. US EPA AirNow The SRP itself depends on the ozone absorption crosssection in the UV, at 253.65 nm.

MONITORING Traceability of ozone measurements Since the first version in 1982, more than 60 NIST SRPs have been constructed and act as primary standards for local, regional and international ozone monitoring networks Reference Instrument (BIPM-SRP27) National standard WMO/GAW World Calibration Centre (EMPA) Regional networks calibration centre Regular calibrations Local stations WMO/GAW stations Regional stations The BIPM runs an on-going programme of comparison to demonstrate agreement between all national standards. BIPM Ozone Comparisons Programme

MONITORING Challenging the Traceability with different methods The most commonly used method to measure Ozone (ground level) is by UV photometry. gravimetry NO 2 Ozone can also be measured by Gas Phase Titration : reaction with NO to produce NO 2. UV photometry is anchored to the ozone absorption cross-section at a specific wavelength. Ozone measured by Gas Phase Titration is traceable to NO and/or NO 2, generally known by gravimetry. NO gravimetry I 0 O 3 I UV photometry Gas Phase Titration and UV photometry comparisons highlighted a bias in the absorption cross-section, when using the conventionaly agreed value of Hearn-61.

VALUE Review of 14 selected published values Identification Author(s) Year Traceability AFCRC-59 Inn and Tanaka 1959 Total pressure Hearn-61 Hearn 1961 Decreasing ozone pressure JPL-64 De More and Raper 1964 Oxygen pressure in gas buret after full conversion Griggs-68 Griggs 1968 Total pressure JPL-86 Molina and Molina 1986 Total pressure UniMin-87 Mauersberger et al. 1987 Total pressure HSCA-88 Yoshino et al. 1988 Total pressure UniReims-93 Brion et al. 1993 Decreasing ozone pressure UniBremen-99 Burrows et al. 1999 NO 2 cross-section via titration of O 3 with NO UPMC-04 Dufour et al. 2004 Total pressure via IR absorption and LNE-SRP comparison Different traceabilities: Total pressure : absorption measurement on pure ozone, including purity or not. Decreasing ozone pressure: absorption measurement on ozone, assuming decomposition to oxygen only. Titration: ozone concentration deduced after gas phase titration with nitrogen monoxide (NO). Absorption cross-section recalculated after comparison with a UV photometer. NIES-06 Tanimoto et al. 2006 NO gravimetric standards via titration and SRP comparison UniBremen-14 Gorshelev et al. 2014 Total pressure BIPM-15 Viallon et al. 2015 Total pressure via UV laser and SRP comparison BIPM-16 Viallon et al. 2016 NO gravimetric standards via titration and SRP comparison

VALUE How well can we measure the absorption cross-section? Each published measurement was scrutinised to re-evaluate its uncertainty. This was an important part of the job as weights are inversely propotionals with uncertainties. Most underestimated uncertainties in direct absorption measurements I 0 P I 0 e (-nσl) Sample pressure ozone pressure Many authors had assumed that their ozone sample was 100% pure. Purity between 92% and 99.6% for the most careful measurements is more reasonable. L Light path length gas cell length Due to divergent light and/or reflections on the gas cell windows, the effective light path length is often larger than the gas cell length.

VALUE Dealing with asymmetric uncertainties Biases not estimated by the authors were considered in an asymmetric uncertainty 1.0x10-2 original uncertainty u- u+ Example of bias on path length in UniMin-87 5.0x10-3 underestimated path length relative uncertainty 0.0-5.0x10-3 -1.0x10-2 repeatability purity pressure path length temperature other HG lines combined over-estimated cross-section (~1/l) enlarged negative component of the uncertainty

VALUE Advanced statistical tools to calculate a consensus value The 14 selected values data are mutually consistent according to the conventional Cochran (chi-squared) test. To calculate a consensus value, a Monte Carlo and a DerSimonian-Laird procedure were compared and found equivalent. The recommended value is 1.2% lower than the current value (Hearn-61) implemented in reference instruments for tropospheric ozone measurements. Uncertainty 6 times smaller!

CONSENSUS O 3 Cross Section Task Group To reach a consensus, a Task Group was created and asked to review all published data. It was created within the Gas Analysis Working Group (GAWG) of the CCQM and is composed of: 6 GAWG members Joseph Hodges (NIST) - Chairman Joële Viallon (BIPM) Executive Secretary Robert Wielgosz (BIPM) Sangil Lee (KRISS) Paul Brewer (NPL) Jari Walden (FMI) CCQM / GAWG + 5 other experts Antonio Possolo Victor Gorshelev Mary Ann Smith Brian Drouin Christof Janssen NIST IUP-Bremen NASA JPL UPMC - Paris statistics UV-VIS FT spectroscopy of ozone Infrared spectroscopy of ozone Microwave spectroscopy of ozone Pure ozone generation & UV-VIS spectroscopy

CONSENSUS Statement of Work and Terms of Reference Recommend an SI-traceable value and uncertainty of the room-temperature O 3 cross section at the wavelength of 253.65 nm (air) which corresponds to Hg lamp emission sources used in ozone standard reference photometers (SRPs). Guidelines for Data Analysis & Review Identified a set of 14 independent, peer-reviewed 254-nm cross section measurements for O 3 Selection Criteria Publication dates 1950 2016 Room temperature (295 K ± 2.5 K) cross section data Cross section explicitly indicated in publication or inferred via simple calculation For repeated measurements by a group, only the last published value will be used Data are not to be corrected. Known bias is to be introduced via uncertainty Uncertainties to be evaluated according to GUM (1995). May require introducing additional uncertainty not specified in the original publication

NEW NEW Motivation toward a change Current value appears biased : Comparisons between UV absorption and Gas Phase Titration methods highlighted a bias coming from the ozone absorption cross-section Recommended change at other wavelengths by ACSO This committee of 49 researchers analyzed available dataset in the Huggins band and recommended a change from the so-called BP set (linked to Hearn-61) to a more recent set measured at IUP- Bremen. Agreement in all bands is required to ensure agreements between instruments / atmospheric layers (satellite, Dobson, Brewer, Sondes) Slope of [O3]UV vs [O3]GPT 1.07 1.06 1.05 1.04 1.03 1.02 1.01 1 0.99 0.98 0.97 0.96 0.95 [O 3 ] UV vs. [O 3 ] GPT Studies UV photometry currently uses Hearn-61 value DeMore [1976] Bass [1977] Paur [1977] Fried [1982] BIPM [2005] Tanimoto [2006] Study Bias > 2 % Absorption cross-sections of Ozone in the ultraviolet and visible spectral regions Status report 2015 July 2016Journal of Molecular Spectroscopy 327:105-121, DOI10.1016/j.jms.2016.07.007

NEW NEW Impact of recommending a NEW standard Increase of reported ozone concentrations shifting the ozone absorption cross-section down by 1. 2% will induce an increase of 1.2% in ozone measurements Lead to actions for improved air quality for the World s Population Sofen, E. D., Evans, M. J., and Lewis, A. C.: Updated ozone absorption cross section will reduce air quality compliance, Atmos. Chem. Phys. Discuss., 15, 19537-19551, doi:10.5194/acpd-15-19537-2015, 2015. xx OO 3 = 1 σσσσ TT TT ssssss PP ssssss PP ln ( II II 0 ) Ozone mole fraction measurement equation when measured by UV photometry Impact on compliance with air quality regulation A study dated 2015 showed that a shift of 1.8% (based on BIPM-15 value) increases the number of non-compliant sites by 18 to 20%.

NEW NEW Steps towards an accepted change GAW Scientific Advisory Group on Reactive Gases Absorption Cross Section of Ozone 2019 Stakeholders consultation via meetings 2020 Recommendation of new value with uncertainty + implementation plan and date 2018 Task Group recommended value published Environmental Protection Agencies, Via NMIs and DIs? 2016 Discussion within GAWG enough evidence for change Monitoring Networks AQUILA meeting, etc ISO 13964 (Ozone by UV photometry) 4/18 Ozone photometers manufacturers

TROPOSPHERIC Atmospheric Ozone Measurements In satellites : by spectroscopy using large spectrum Ozone column from ground: by spectroscopy in various regions balloons : ozone sondes (calibrated with UV photometers) In aircrafts : UV analysers At ground : UV analysers courtesy of Windows to the Universe, http://www.windows.ucar.edu

TROPOSPHERIC Agreement in all spectral bands is required to ensure agreements between instruments / atmospheric layers (satellite, Dobson, Brewer, Sondes) Ozone absorption cross-sections in other bands Most lab IR measurements have been rescaled according to the 253.7 nm O 3 cross-section values HITRAN 2016 database will use Brion et al. temperature and wavelength dependence

CCQM/GAWG Task Group on Ozone Cross-Section members Joseph Hodges (NIST - Chair) Joële Viallon (BIPM executive secretary) Robert Wielgosz (BIPM) Sangil Lee (KRISS) Paul Brewer (NPL) Jari Walden (FMI) Antonio Possolo (NIST) Thanks Victor Gorshelev (IUP Bremen) Mary Ann Smith (NASA) Brian Drouin (JPL) Christof Janssen (UPMC) Pure liquid ozone produced during the ozone cross-section measurements performed at the BIPM in 2014. Paper submitted to Metrologia special issue Focus on Advances in Metrology in Chemistry and Biology