ph / Temperature Meter for Cheese with Application Specific Probe

Similar documents
ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

One-hand ph/temperature measuring instrument

Guide to ph Analysis.

ph 5 Meter Manual The LaMotte 5 Series

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Compact ph Measuring Instruments With Pro Engineering

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

HI HI 8633 HI HI 8734 HI

OPERATING INSTRUCTIONS

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Rapid RH Portable ph Meter. User's Manual

Concise laboratory catalogue

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Perfect Electrochemical Analysis Professional Meters Basic Meters Portable Meters Sensors

STANDARD OPERATING PROCEDURE

Chemistry MultiMeasure Sensor PS-2170

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

INE-PHS-3E ph Meter Operating Manual

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Instruction Manual HI Refractometer for Sodium Chloride Measurements

PH700 Benchtop ph Meter Instruction Manual

INE-DDB-303A Portable Conductivity Meter Instruction Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Electrochemistry. Conductivity of strong and weak electrolytes LEC 06. What you need: What you can learn about. Principle and tasks

Bante210 Benchtop ph Meter Instruction Manual

Operating Instructions for Ammonium ISE Specifications

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

Differential ph Probe Type 18

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

Automatic titrators, TitroMatic

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

Metso Concentration Measurement 3300

LCS Laboratory Inc. 700 Collip Circle, Unit 218, London ON, N6G 4X8, (519) ,

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

DOC /2013, Edition 1. User Manual

symphony Reference Electrodes

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Process Instrumentation analyzers

INFRARED THERMOMETER Model : TM-959

VIBRATION METER. Instruction Manual.

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

Understanding ph Troubleshooting and Diagnostic information

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Designed to go where you work

User Guide. Green ph Electrodes

New! 2010 Model. Model No

TOP Offers Special Measuring Instruments

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

473 Dew Point Hygrometer

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

symphony Multisensor Probes

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

GENERAL INSTRUCTIONS GENERAL PREPARATION

ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

1) A ph/mv meter or an ion meter, either line operated or portable.

473-SHX Dew Point Mirror

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Acid Deposition and Oxidant Research Center (ADORC)

Freezing point depression (Item No.: P )

# 12 ph-titration of Strong Acids with Strong Bases

ION SELECTIVE MEASUREMENT

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

GENERAL INSTRUCTIONS GENERAL PREPARATION

Instruction Manual HI Refractometer for Invert Sugar Measurements

ION 5 and ION 6 Acorn Series Meters

Starter Starter Electrodes

The ph Value The ph value is a logarithmic measure for the concentration of the H ions in a hydrous solution and indicates, by a numerical value, whet

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Frequently asked question about our new Platinum Water Ionizer

TOXI-SCREENING KIT. Microbiotest for ultra-rapid on-site. toxicity screening of water STANDARD OPERATIONAL PROCEDURE

White Paper. Perform Conductivity Measurements In Compliance with USP <645>

473 Dew Point Hygrometer

[Agilent Technologies] [Electrochemistry Products] Quick Reference

Density of an Unknown

ISEmax CAM40/CAS40. Technical Information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

How Electrode Design Correlates with Optimum Performance in ph Measurement

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

INTRODUCTION TO ACIDS, BASES AND TITRATION

MA882, MA883, MA884, MA885

Transcription:

C/ F ph / Temperature Meter for Cheese with Application Specific Probe ph

Application Importance ph is an essential measurement throughout the entire cheesemaking process. From the initial measurements of incoming milk to the final measurements of ripened cheese, ph is the most important parameter for cheese quality and safety control. Acidification of milk begins with the addition of bacterial culture and rennet. The bacteria consume lactose and create lactic acid as a byproduct of fermentation, lowering the ph of the milk. Once the milk reaches a particular ph, the rennet is added. The enzymes in rennet help to speed up curdling and create a firmer substance. For cheesemakers that dilute their rennet, the ph of the dilution water is also critical; water that is near ph 7 or higher can deactivate the rennet, causing problems with coagulation. Once the curds are cut, stirred, and cooked, the liquid whey must be drained. The ph of whey at draining directly affects the composition and texture of the final cheese product. Whey that has a relatively high ph contributes to higher levels of calcium and phosphate and results in a stronger curd. Typical ph levels at draining can vary depending on the type of cheese; for example, Swiss cheese is drained between ph 6.3 and 6.5 while Cheddar cheese is drained between ph 6.0 and 6.2. The next stages of milling and salting are affected by ph as well. During milling, curds are cut into smaller pieces to prepare the cheese for salting. Curds with a lower ph at milling result in a harder cheese. A low ph will also result in higher salt absorption during the salting stage. When curds are pressed into a final, solid form, the ph directly affects how well the curds fuse together. If the ph is too high during pressing, the curds will not bind together as well and the final cheese will have a more open texture. During brining, the cheese soaks up salt from the brine solution and loses excess moisture. The ph of the brine solution should be close to the ph of the cheese, ensuring equilibrium of ions like calcium and hydrogen. If there is an imbalance during brining, the final product can have rind defects, discoloration, a weakened texture, and a shorter shelf life. Cheeses must fall within a narrow ph range to provide an optimal environment for microbial and enzymatic processes that occur during ripening. Bacterial cultures used in ripening are responsible for characteristics like the holes in Swiss cheese, the white mold on Brie rinds, and the aroma of Limburger cheese. A deviation from the ideal ph is not only detrimental to the ecology of the bacteria, but also to the cheese structure. Higher ph levels can result in cheeses that are more elastic while lower ph levels can cause brittleness.

HI99165 Features and Specifications HI99165 ph / Temperature Meter for Cheese with Application Specific Probe Waterproof Application specific electrode Automatic Temperature Compensation Automatic one or two-point calibration Multi-level LCD display On-screen tutorial for calibration and set up Stability indicator for accurate data recording Battery Error Prevention System Battery life displayed on startup Supplied as a complete kit The Hanna Instruments HI99165 is a durable, waterproof, and portable ph and temperature meter designed specifically for cheese analysis. Automatic calibration is done at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature measurements. The split-level LCD displays both ph and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions. shown actual size Calibrate samples right in the case Our custom carrying case features a beaker holder for calibration on the production floor. HI99165 ph / Temperature Meter for Cheese

On-screen Features Temperature C and F measurement modes Buffer sets Calibrate to standard (ph 4.01, ph 7.01, ph 10.01) or NIST (ph 4.01, ph 6.86, ph 9.18) buffers Calibration prompts On-screen prompts during the calibration process Stability indicator "Not Stable" tag disappears when the reading is stable for accurate data recording Freeze readings Press the SET/HOLD button to hold readings on the display Battery percentage Battery percentage is displayed at startup On-screen guides On-screen quick guides for entering calibration and set up Specifications Range* -2.00 to 16.00 ph Resolution 0.01 ph ph Accuracy ±0.02 ph Calibration automatic, one or two-point calibration with two sets of standard buffers (standard ph 4.01, 7.01, 10.01 or NIST ph 4.01, 6.86, 9.18) Temperature Temperature Compensation Range* Resolution Accuracy Probe (included) automatic from -5.0 to 105.0ºC (23 to 221 F) -5.0 to 105.0 C / 23.0 to 221.0 F 0.1 C/0.1 F ±0.5 C (up to 60 C); ±1.0 C (outside) / ±1 F (up to 140 F); ±2.0 F (outside) FC242D pre-amplified ph probe with internal temperature sensor, DIN connector and 1 m (3.3 ) cable (included) Additional Specifications Battery Type/Life 1.5V AAA (3) / approximately 1200 hours of continuous use Auto-off auto-off after 8 minutes of non-use Environment 0 to 50 C (32 to 122 F); RH max. 100% Dimensions / Weight 152 x 58 x 30 mm (6.0 x 2.3 x 1.2 ) / 205 g (7.2 oz) * Limits will be reduced to actual sensor limits

FC242D Features and Specifications FC242D ph / Temperature Probe for Cheese Stainless steel body Conic glass tip Low temperature glass Built-in temperature sensor Viscolene electrolyte The viscolene electrolyte offers a hard gel interface between the inner electrode components and the sample being measured. The electrolyte is silver-free for use in cheese products and is maintenance-free. AISI 316 stainless steel body The metal body offers durability in the production facility and can withstand chloride concentrations that cause corrosion in other types of alloys. Low temperature glass The FC242D electrode uses Low Temperature (LT) glass for the sensing bulb. The LT glass tip is a lower resistance glass formulation. As the temperature of the sensing glass decreases, the resistance of the LT glass will increase approaching that of standard glass at ambient temperatures. The FC242D is suitable to use with samples that measure from 0 to 50 C. Built-in temperature sensor A thermistor temperature sensor is in the tip of the indicating ph electrode. A temperature sensor should be as close as possible to the indicating ph bulb in order to compensate for variations in temperature. Conic tip shape This design allows for penetration into solids, semi solids, and emulsions for the direct measurement of ph in cheese products. Specifications Description Reference Junction Electrolyte Max Pressure pre-amplified ph / temperature probe single ceramic viscolene 0.1 bar Range ph: 0 to 12 Recommended Operating Temperature Tip /Shape Temperature Sensor Amplifier Body Material 0 to 50 C (32 to 122 F) conic yes yes AISI 316 stainless steel Cable coaxial; 1 m (3.3 ) Connection DIN

Ordering Information HI99165 includes: FC242D pre-amplified ph probe with internal temperature sensor 100 ml plastic beaker HI70004 ph 4.01 buffer solution sachet HI70007 ph 7.01 buffer solution sachet HI700642 electrode cleaning solution for cheese residues sachet (2) 1.5V AAA batteries (3) instruction manual and visual quick start guide rugged carrying case with custom insert Accessories Code FC242D Description FC242D pre-amplified ph probe with internal temperature sensor, DIN connector and 1 m (3.3 ) cable (included) HI70004P ph 4.01 buffer solution, 20 ml sachets (25) HI7004L ph 4.01 buffer solution, 500 ml bottle HI70007P ph 7.01 buffer solution, 20 ml sachets (25) HI710023 shockproof rubber boot (orange) HI7007L ph 7.01 buffer solution, 500 ml bottle HI700642P electrode cleaning solution for cheese residues, 20 ml sachets (25) HI70642L electrode cleaning solution for cheese residues, 500 ml bottle HI70300M HI710023 HI710024 HI98501 electrode storage solution, 230 ml bottle shockproof boot (orange) shockproof boot (blue) Checktemp digital thermometer HI98501 Checktemp digital thermometer HI70642L electrode cleaning solution for cheese residues, 500 ml bottle HI710024 shockproof rubber boot (blue) HI99165 1.0 08/15 PRINTED IN THE USA