MOLEKULE INC. TEST REPORT

Similar documents
Intertek Environmental VOC Emissions

FUNDERMAX GMBH TEST REPORT

VOC TEST REPORT CDPH

COMPLIANCE EMISSIONS TEST California Dept. of Public Health Standard Method Version 1.1 and FloorScore Flooring Evaluation

VOC TEST REPORT CDPH

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances

VOC EMISSION TEST REPORT BREEAM NOR

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT CDPH

VOC EMISSION TEST REPORT ISO 16000

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

Test Report- VOC emission regulations in Europe

VOC TEST REPORT AgBB

Test Report- VOC emission regulations in Europe

ASTM D5116 Emissions Test Report with CDPH SM V Loading Scenarios per Cradle to Cradle Standard v3.0 Sect. 5.8

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

VOC TEST REPORT EMICODE

VOC TEST REPORT EMICODE

Test Report in accordance CDPH-IAQ

Test Report- VOC emission regulations in Europe

Test Report- VOC emission regulations in Europe

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Test Report in accordance CDPH-IAQ

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

ECMA Determination of Chemical Emission Rates from Electronic Equipment - Part 2 (not using-consumables) 8 th Edition / June 2017

Emission measurements according to, M1 (3 appendices)

VOC TEST REPORT Indoor Air Comfort GOLD

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

VOC TEST REPORT Indoor Air Comfort

VOC TEST REPORT Indoor Air Comfort

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Test report No. MAIC Testing and evaluating of a digital printed paper material according to AgBB/DIBt-scheme.

VOC TEST REPORT Tarkett Indoor Air Quality

TEST REPORT Formaldehyde Reduction

VOC TEST REPORT Indoor Air Comfort GOLD

Test Report- VOC emission regulations in Europe

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

SURVEY OF CHEMICALS EMISSION FACTORS FROM BUILDING MATERIALS FOR INTERIORS

Electrical Parameter. Measurement and Test Report for. MaxGreen LED Ltd.

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

TEST REPORT. Test Method : See the attached sheets.

AA-ANSIBIFMA-Jun2408, Page 1 of 16

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

TEST REPORT. Page 1 of 11

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Watercare Air Quality Group March 2002 APPENDIX A. Monitoring Site Location Diagrams

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

ECMA-328. Determination of Chemical Emission Rates from Electronic Equipment. 4 th Edition / December Reference number ECMA-123:2009

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Information technology Office equipment Determination of chemical emission rates from electronic equipment

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing.

Certificate of Conformance

Characterising Volatile Organic Compounds from Sewer Emissions by Thermal Desorption coupled with Gas- Chromatography-Mass Spectrometry

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

APPENDIX A. Desorption Tube Packing and Conditioning

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS


THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Environmental Air Monitoring by TD/GC-TOF MS with Variable Energy Ionization

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

SAB Soil Vapour Forum July 8, Overview of Soil Vapour Assessment From A Laboratory Industry Perspective

AM23 - Texas A&M University Health Science Purchase Order

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2

ECMA Determination of Chemical Emission Rates from Electronic Equipment Part 1 (using-consumables) 8 th Edition / June 2017

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

IMPROVEMENT OF IAQ BY COATING OF ADSORPTIVE POLYMER: THE DEVELOPMENT OF MATERIAL, EVALUATION AND ITS APPLICATION

This document is a preview generated by EVS

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

M+W Products. Controlled Environments Trace Analysis

TEST REPORT IEC Photobiological safety of lamps and lamp systems

ISO INTERNATIONAL STANDARD. Indoor air Part 2: Sampling strategy for formaldehyde

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

CERTIFICATE OF CALIBRATION

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Transcription:

MOLEKULE INC. TEST REPORT SCOPE OF WORK VOC Emissions on Part C Test 1 REPORT NUMBER 103658037GRR-002 ISSUE DATE 18-October-2018 PAGES 8 DOCUMENT CONTROL NUMBER Per GFT-OP-10 (6-March-2017) 2018 INTERTEK

4700 Broadmoor Ave SE, Suite 200 Kentwood, MI 49512 Telephone: +1 616 656 7401 Facsimile: +1 616 656 2022 www.intertek.com SECTION 1 CLIENT INFORMATION Attention: David Sanabria Molekule Inc. 2507 Bryant St San Francisco, CA 94110 Phone: +1 (954) 579-3495 Email: dsanabria@molekule.com Taylor Gebben Project Engineer Jesse Ondersma, Ph.D. Project Reviewer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Page 2 of 8

SECTION 2 SUMMARY AND CONCLUSION Date Received: Dates Tested: 17-August-2018 21-September-2018 to 25-September-2018 DESCRIPTION OF SAMPLES Part Name: Part C Test 1 Filter Batch Code: 2078D Model ID: MH1M-LHA180525-001974 Manufacturer / Location: Date of Manufacture: Materials Submitted: One (1) Filter Unit Condition of Samples: Shipping Condition: Good Condition Sample ID: GRR1808170004 WORK REQUESTED/APPLICABLE DOCUMENTS VOC Reduction Testing: ISO 16000-3, ISO 16000-6 Referencing NRCC-54013 Intertek Quote: Qu-00920629 SAMPLE DISPOSITION At the completion of testing, samples were returned to Molekule Inc. Page 3 of 8

SECTION 3 VOC EMISSIONS ANALYSIS Date Received: Dates Tested: 17-August-2018 21-September-2018 to 25-September-2018 DESCRIPTION OF SAMPLES: Part Name: Part C Test 1 Filter Batch Code: 2078D Model ID: MH1M-LHA180525-001974 Manufacturer / Location: Date of Manufacture: Materials Submitted: One (1) Filter Unit Condition of Samples: Shipping Condition: Good Condition TEST PROCEDURE: Test Method: Modified NRCC-54013 (04-2011) Number of Samples: One (1) TEST SUMMARY: The emissions testing were performed according to modified NRCC-54013 Method for testing portable air cleaners. The unit was turned off and placed in the testing chamber. The chamber was sealed and purged for a minimum of 6 air exchanges to remove lab air. A photograph of the tested sample is included herein. Air samples were collected prior to the sample being placed in the chamber (Blank), with the sample turned off within the chamber (OFF). The challenge chemicals (formaldehyde, toluene, and d-limonene) were injected and allowed to circulate for 2 hours during which an air sample was taken, time 0 h. Once the device was turned on air samples were taken at (0 h), and at 4, 6, 24, 26, 28, 48, 50, and 52 h after turning the unit on. Samples analyzed for toluene, d-limonene, individual VOCs, and TVOC were collected on multisorbent tubes containing glass wool, Tenax TA 35/60 and Carbograph 5 TD 40/60 with an air flow rate of 200 ml/min. These VOC samples were analyzed by thermal desorption-gas chromatography/mass-spectrometry, TD-GC/MS. TVOCToluene represents the total of all identified and unidentified VOCs between n-c6 and n-c16 as measured by the GC/MS TIC method with an integration cutoff of 0.2 µg/m3 and expressed as a toluene equivalent value as defined in ISO 16000-6. Individual VOCs were calculated using calibration curves based on pure standards or based on toluene equivalent. Samples analyzed for analyzed for low molecular weight carbonyls were collected on cartridges treated with 2,4-di-nitrophenylhydrazine (DNPH) and were analyzed using high performance liquid chromatography, HPLC. Individual VOCs were calculated using calibration curves based on pure standards. TEST NOTES OR DEVIATIONS: Testing performed without deviation unless noted below. Page 4 of 8

TEST PARAMETERS: Table 1: Sample and Chamber Conditions During Test Period PARAMETER SYMBOL VALUE UNITS Sample Loading A 1 Unit Chamber Volume V 8.3 m 3 Inlet Air Flow Rate Q 0.15 m 3 h 1 Air Change Rate ACH 0.018 h 1 Testing Duration t 52 h Average Temperature (Range) T 24.2 (23.4-24.4) C Average Humidity (Range) RH 53.7 (47.7-59.0) % RH TEST RESULTS: Table 2: Carbonyl Emissions Determined by HPLC (µg/m 3 ) CHEMICAL CAS # BLANK OFF MDL MQL Formaldehyde 50-00-0 BDL 1.4 0.6 1.7 Propanal 123-38-6 1.0 0.4 0.3 0.9 Butanal 123-72-8 BDL BDL 0.3 1.0 Pentanal 110-62-3 BDL BDL 1.2 3.5 Hexanal 66-25-1 BDL BDL 0.1 0.4 1 Blank and DUT off blank collected 30L air sample Table 3: Continued Carbonyl Emissions Determined by HPLC (µg/m 3 ) CHEMICAL CAS # 0 H 0.25 H 0.5 H 0.75 H 1 H 2 H 3 HR 4 HR Formaldehyde 50-00-0 167.1 118.9 100.9 88.2 76.8 47.4 30.8 25.8 Propanal 123-38-6 BDL BDL BDL BQL BQL BDL BDL BDL Butanal 123-72-8 BDL BDL BDL BDL BDL BDL BDL BDL Pentanal 110-62-3 BDL BDL BDL BDL BDL BDL BDL BDL Hexanal 66-25-1 BDL BDL BDL BDL BDL BDL BDL BDL Table 4: Continued Carbonyl Emissions Determined by HPLC (µg/m 3 ) CHEMICAL CAS # 24 HR 26 HR 28 HR 48 HR 50 HR 52 HR MDL MQL Formaldehyde 50-00-0 BQL BQL BQL BQL BQL BQL 5.7 17.2 Propanal 123-38-6 BDL BDL BDL BDL BDL BDL 2.9 8.6 Butanal 123-72-8 BDL BDL BDL BDL BDL BDL 3.4 10.3 Pentanal 110-62-3 BDL BDL BDL BDL BDL BDL 11.7 35.2 Hexanal 66-25-1 BDL BDL BDL BDL BDL BDL 0.1 0.4 Page 5 of 8

Table 5: VOC Emissions Determined by GCMS (µg/m 3 ) CHEMICAL CAS # BLANK OFF MDL MQL Toluene 108-88-3 BDL BDL 0.4 1.1 D-Limonene 5989-27-5 BDL BDL 0.9 2.7 Tetradecane 629-59-4 3.4 3.4 - - Pentadecane 629-62-9 2.5 3.0 - - TVOCToluene - 7.5 7.5 6.7 20.1 Table 6: Continued VOC Emissions Determined by GCMS (µg/m 3 ) CHEMICAL CAS # 0 H 0.25 H 0.5 H 0.75 H 1 H 2 H 3 HR 4 HR Toluene 108-88-3 730.4 274.8 142.6 73.1 42.4 < 9.5 < 9.5 < 3.2 D-Limonene 5989-27-5 414 135 56.2 25.9 BQL BDL BDL BDL Tetradecane 629-59-4 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 Pentadecane 629-62-9 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 TVOCToluene N/A 1481 519.9 250.6 104.9 BDL BDL BDL BDL Table 7: Continued VOC Emissions Determined by GCMS (µg/m 3 ) CHEMICAL CAS # 24 HR 26 HR 28 HR 48 HR 50 HR 52 HR MDL MQL Toluene 108-88-3 BDL BDL BDL BDL BDL BDL 3.2 9.5 D-Limonene 5989-27-5 BDL BDL BDL BDL BDL BDL 7.4 22.3 Tetradecane 629-59-4 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 - - Pentadecane 629-62-9 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 - - TVOCToluene N/A BDL BDL BDL BDL BDL BDL 56 168 Page 6 of 8

PHOTOGRAPHS: Figure 1: Photograph of Molekule air cleaner as loaded in the test chamber. Page 7 of 8

SECTION 4 FACILITIES AND EQUIPMENT: TD-GCMS Markes TD-100 Thermal Desorption INSTRUMENTATION USED: Agilent 7890A GC Agilent 5975C MS COLUMN USED: Agilent HP-Ultra 2 HPLC INSTRUMENTATION USED: Agilent 1260 COLUMN USED: Poroshell 120 EC-C18 Page 8 of 8