Modular Compact Rheometers MCR 72 MCR 92

Similar documents
Modular Compact Rheometers MCR 72 MCR 92

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

International Academy of Rheology Program

Thermo Scientific HAAKE Viscotester iq Rheometer. Individual. Intuitive. Intelligent. Discover the difference.

Physica MCR. The modular rheometer series. ::: Intelligence in Rheometry

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Viscometry Rheometry. The Range. ::: Intelligence in Rheometry

Physica MCR. The Modular Rheometer Series. ::: Intelligence in Rheometry

Extended Material Characterization MCR

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

MCR. Applicationspecific. Accessories for Additional Parameter Setting

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

The Rheology Handbook

Extended Material Characterization. ::: Intelligence in Rheometry

Investigation of Emulsified Asphalts Properties by DSR to Evaluate their Performance

::: Application Report

Rheology of cellulose solutions. Puu Cellulose Chemistry Michael Hummel

Well prepared - good results

Interfacial Shear Rheology of Films Formed by Coffee

MCR. The Modular Compact Rheometer Series. ::: Intelligence in Rheometry

Characterization of the structure at rest in foods (Example: Ketchup)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

How to measure the shear viscosity properly?

Introduction to Viscometry and Rheology, Basics, Rotational Testing. Basic Seminar Applied Rheology

TA Instruments NEW AR-G2 INTRODUCING THE WORLD S FIRST MAGNETIC BEARING RHEOMETER! The World Leader in Thermal Analysis and Rheology Systems

AN014e. Non-standard geomtries for rheological characterization of complex fluids. A. Franck, TA Instruments Germany

Different experimental methods in stress and strain control to characterize non-linear behaviour

Handle Food Samples with Care for Reliable Rheological Results

AUTOMATED FORMULATION SYSTEMS

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Guideline for Rheological Measurements

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

In-depth analysis of viscoelastic properties thanks to Microrheology: non-contact rheology

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

MDR 3000 Professional Professional Moving Die Rheometer. Testing instruments. Laboratory Equipment. Software systems. Service.

LUMiSizer. Dispersion Analyser. The All-in-One. Dispersion Analyser. Stability Demixing Consolidation Particle Sizing

Dynamic Mechanical Analysis of Solid Polymers and Polymer Melts

Your partner in Science!

Modulyzer. Multiparameter Measuring Systems. ::: Unique Density & Concentration Meters

Rheology step 1. Principles of Rheology and its Measurement techniques. Panta Rei. TRAINING. Viscosity, Elasticity and Viscoelasticity

Article for the 29 th Sensing Forum

Investigation of Suitable Testing Method for GTR Modified Asphalt Binder

SUMMARY A STUDY OF VISCO-ELASTIC NON-NEWTONIAN FLUID FLOWS. where most of body fluids like blood and mucus are non-newtonian ones.

Non Newtonian Fluid Dynamics


RHEOLASER LAB MICRORHEOLOGY & END USE PROPERTIES ANALYSIS. MICRORHEOLOGY

Optical & Spectroscopic Insight into Rheology. SR Kim

Rheometer: Procedure: Part A: Viscosity v Time

Middle East Technical University Department of Mechanical Engineering ME 305 Fluid Mechanics I Fall 2018 Section 4 (Dr.

Contents. Preface XIII. 1 General Introduction 1 References 6

The principals of rheology In pharmaceutical technology

Introduction to Rheology Basics

Rheology/Viscometry. Viscometry

Using rheology to study the hardness and spreadability of butter

Basics of Applied Rheology

Using Rheological Properties to Evaluate Storage Stability and Setting Behaviors of Emulsified asphalts

Rheology The relationship between rheological response and material structure

Analyzing & Testing. Comprehensive Material Characterization. Leading Thermal Analysis

Thickeners + Rheology Guide

Measuring the rheology of thermoplastic polymer melts

Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr Althengstett Tel

Pharmaceutics I صيدالنيات 1. Unit 6

Measuring structure of low viscosity fluids in oscillation using rheometers with and without a separate torque transducer

A Technique for Characterizing Complex Polymer Solutions in Extensional Flows. Gavin Braithwaite Stephen Spiegelberg

The solution for all of your

Mr.N.Srikar M.Pharm.,(Ph.D) KRISHNA TEJA PHARMACY COLLEGE

Temperature-dependent viscosity analysis of SAE 10W-60 engine oil with RheolabQC rotational rheometer

Modular Microscope Accessory

Drilling Fluid Thixotropy & Relevance

Viscosity Testing of Solutions and Suspensions for Litigation Purposes A technical primer for attorneys

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Thickeners/Rheology Guide

1/7. 4-1) Introduction

CHAPTER 3. CONVENTIONAL RHEOMETRY: STATE-OF-THE-ART. briefly introduces conventional rheometers. In sections 3.2 and 3.

A Comprehensive Approach to Barite Sag Analysis on Field Muds

Comments on Use of Reference Fluid to Verify DSR

Characterization of cellulose nanofibrils (CNF)

Technical Research. Comparison of Rheological Methods to Predict Gel Coat Sag Resistance. INTERPLASTIC CORPORATION Thermoset Resins Division

DOWNLOAD OR READ : THE RHEOLOGY HANDBOOK 4TH EDITION PDF EBOOK EPUB MOBI

Making chemistry work for you. ISCATHIX Rheological Additives

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

Buy1Get1 FREE. TA Instruments. The World Leader in Thermal Analysis and Rheology Systems

Langmuir and Langmuir-Blodgett Deposition Troughs

RH7-D & RH10-D CAPILLARY RHEOMETERS

Rheometry. II.1 Introduction

CHANGES OF RHEOLOGICAL PARAMETERS OF POLYPROPYLENE AND POLYETHYLENE AFTER EXPOSURE IN ALIPHATIC n-hexane

GTR: DSR Evaluation and Geometry Recommendation

Modular Rheometer Platform for Individual Demands. Thermo Scientific HAAKE MARS III

Measure, what is measurable, and make measurable that which is not. Galileo Galilei ( ) Portfolio

A BASIC INTRODUCTION TO RHEOLOGY

Modelling of dispersed, multicomponent, multiphase flows in resource industries Section 4: Non-Newtonian fluids and rheometry (PART 1)

Rheological Measurements of Cementitious Suspensions Using a Grooved Measuring Device

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

RHEOLOGY AS A POWERFULL TOOL FOR SCIENTIFIC AS WELL INDUSTRIAL CHARACTERISATION OF NEW MATERIALS BASED ON POLYMER-CLAY NANOCOMPOSITES.

Applied Rheology Richard R. Eley, Ph.D. Senior Scientist ICI Paints Sprague Road Strongsville, OH 44136

CONSISTENCY OF RHEOLOGICAL EXPERIMENTS FOR PSA CHARACTERIZATION

Interfacial Rheology of Gas/Liquid and Liquid/Liquid Interfaces Philipp Erni, Peter Fischer, and Erich J. Windhab

RHEOLOGY Principles, Measurements, and Applications. Christopher W. Macosko

Transcription:

Modular Compact Rheometers MCR 72 MCR 92

MCR 72 and MCR 92 See things change With a rheometer, you can follow the change in your sample s viscosity from one measuring point to the next. You instantly gain deeper insights into your sample s deformation, flow behavior and structure so you can change matters in your favor. Starting out in rheometry, your two wisest choices are MCR 72 and MCR 92 from Anton Paar real rheometer pearls, streamlined for your daily lab routine, easy to use in a Plug and Play fashion and available at an accommodating price. The MCR series has opened more doors and created more testing possibilities than any other rheometer in the world. In keeping with this tradition, MCR 72 and MCR 92 now round off the family as your entry tickets to the world of rheology. To help you get rapidly acquainted with this exciting field and all its possibilities, MCR 72 and MCR 92 come with a wealth of application know-how and introductory materials you will only find at Anton Paar.

Is a single-point measurement sufficient to describe the flow behavior of my sample? What can you do with a rheometer? What is the difference between a viscometer and a rheometer? Viscometers are simple devices. They are based on mechanical ball bearings or torsional spring bearings that rotate a measuring system (e.g. a bob or a spindle) in a single direction. They are ideal for fast and simple tests. Rheometers reveal the full spectrum of a sample under the conditions you define. For quality control, a single-point check might be sufficient. But in general, a single-point measurement provides limited information about the flow behavior of materials. To describe a sample s flow behavior to its full extent you need a rheometer. From just one measurement, rheometers provide a flow curve in a wide speed and torque range. This curve shows the behavior of a sample under varying conditions, such as different shear rates and temperatures. Rotation General single point dark chocolate milk chocolate white chocolate curves of different types of chocolate compared to single-point measurements. For example: Rheological measurements show you the structure of a sample by providing insight into the viscoelastic behavior. Rheometer principles How can I determine the feel and long-term stability of my cream or ointment? Rheometers are built to be more sensitive than viscometers. They have two measurement modes: rotational and oscillatory. Accessories such as plates, bobs, cones, heating and cooling chambers make it possible to study the sample s properties under a wider range of conditions. Rheometers are an excellent tool for research, process and product development as well as for quality control. Measuring systems Long-term stability and the feel when a cream or ointment is applied on the skin are important quality criteria in the cosmetics and pharmaceutical industries. Using a rheometer you can evaluate the elastic portion (G ) and viscous portion (G ) of a sample in an amplitude-sweep test. The relationship between these portions defines how strong the internal network of the sample is, which affects long-term stability and the way a cream feels on the skin when being applied. G, G lg G lg G Cream 1 has a gel-like or solid structure because the elastic portion G is higher than the viscous portion G. lg γ Rotation Oscillation General G, G lg G Will my paint have a nice glossy finish or will it show brush marks and drips? lg G One important quality factor of paint is the surface leveling and sagging behavior once it is applied, since a smooth, glossy and homogenous surface with no droplets or splashes is generally required. The structural strength of the paint should not be too high or too low, to be sure that the internal structure recovers in exactly the right time period to create a good finish. These characteristics are often referred to as thixotropic behavior. When developing or improving paint, the material s time-dependent rheological behavior has to be balanced to get the required result. A rheometer can simulate this behavior in rotational mode using a structural regeneration test ( 3 Interval Time Test/3 ITT ). These curves show a paint which sags (red), a paint which has trouble leveling (green) and a paint which has a good finish (blue) Amplitude Sweep Oscillation Cosmetics Is my slurry pumpable and flowable? The processing and transport characteristics of slurries are strongly dependent on their rheological properties. With a rheometer you can simulate flow resistance in pipes and see the result as flow and viscosity curves. You can also determine the yield point in a flow curve (controlled shear stress mode) which will help you solve problems with slurries that are difficult to pump. Cream 2 behaves more like a liquid as in this case G is higher than G. 0 lg γ 3 ITT Rotation Paints/Coatings Controlled Shear Stress Test Rotation Building Materials/Mining These flow and viscosity curves show the rheological behavior of a slurry. The yield point τ 0 can be calculated from the flow curve (blue). The viscosity curve (red) gives information about the flow behavior of a slurry when being pumped through pipes.

Welcome to the World of Rheology Rheological measurements can give you so much more information about your products but where to start and how to interpret the results? To help you on your way to becoming a rheology expert, Anton Paar gives you access to a wealth of practical information on the www.world-of-rheology.com website. Here you can browse through entertaining elearning courses, download application reports for your industry, register for a free webinar or read through the tips and tricks sections. Introducing Joe Flow, the virtual rheology expert Let Joe Flow, our virtual rheology expert, be your guide to the exciting world of rheology. He will first guide you through the online course Basics of Viscometry to provide you with the basic knowledge of liquids in flow. Then you can learn about the basics of rheology and gain knowledge which will help you in your daily work. Joe Flow s book Applied Rheology With Joe Flow on Rheology Road explains the laws of viscosity and elasticity and provides tips for avoiding errors in your measurements. This is a good reference for everyone starting out in rheology. Further training Anton Paar offers seminars and webinars to help you acquire the know-how you need to get the most out of your rheometer. Thanks to Anton Paar s global network of subsidiaries and sales partners you will find almost every course in our program offered in your area and language. Your knowledge database Are you interested in time- and frequency-dependent measurements on printing inks or the rheological characterization of cheese? These application reports and hundreds of others are available for a wide range of applications and samples on the World of Rheology website. They form a huge database of rheological know-how at your disposal.

The outstanding features of MCR 72 and MCR 92 Designed for your application MCR 72 is equipped with a ball-bearing motor and provides measurements in rotational and also for special applications in oscillatory mode. MCR 92 provides measurements in both rotation and oscillation and has air-bearing motor technology. There is a wide range of accessories available for both models so you can build the setup which perfectly suits your application. Unmatched reproducibility Reproducible settings are essential for obtaining reliable and reproducible results. MCR 72 and 92 feature a motor-driven elevation mechanism and SafeGap (Austrian Patent AT 517074) technology, which ensure that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time. Furthermore, the slow and precise setting minimizes any influence on the sample s structure. Easy fitting of measuring systems When changing between measuring systems, QuickConnect gives you great ease-of-use. This quickfitting coupling allows one-handed connection of the measuring systems, and ensures fast, convenient system changes without the use of a screwing mechanism. Most accurate temperature control Temperature has the biggest influence on rheological measurements. To counteract this MCR 72 and MCR 92 can be used with several air-cooled Peltier temperature units. These CoolPeltier units with an integrated fan for counter-cooling are an accurate, fast and energy-efficient alternative to liquid-circulator counter-cooling systems. 25 years of experience in one motor The air-bearing-supported synchronous EC motor of MCR 92 deploys a frictionless synchronous movement of the rotor inside that enables the most sensitive and therefore most precise movements. Whether investigating solids or low-viscosity liquids your results are accurate across a wide viscosity range. Clear view of the sample TruRay is a unique lighting concept which gives you a clear view of the sample and measurement surface. This is especially important when filling the measuring gap. Automatic tool recognition and configuration Toolmaster is the only completely contact-free automatic tool recognition and configuration system for rheometers. It recognizes measuring systems and temperature control units as soon as these are connected to the rheometer so you don't need to enter this data manually. Step-by-step software The intuitive RheoCompass software helps you find the templates you need, customize test and analysis definitions, export your data and much more. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos for extra support.

Your application - Anton Paar solutions Application Typical samples Measuring procedure Test types Specifications Units MCR 72 MCR 92 Paints & coatings Architectural paints Wall paints Automotive paints Printing inks and pastes Sedimentation/stability curve (ROT) Bearing - Ball Air EC motor (brushless DC) with high-resolution optical encoder - Rotation mode - Oscillation mode - (1 Food Polymers Petrochemicals Resins Chocolate Ketchup Mayonnaise Dairy products Sauces Polymer solutions Polymer melts Drilling fluids Slurries and muds Crude oils Lubricants and greases Resins Adhesives Glues Sedimentation/stability Sedimentation/stability curve (ROT) curve (ROT) curve (ROT) curve (ROT) Direct strain controller - Direct stress controller - Maximum torque mnm 125 125 Minimum torque, rotation µnm 200 1 Minimum torque, oscillation µnm 200 1 Torque resolution nnm 100 100 Angular deflection, set value µrad 1 to 1 to Angular deflection, resolution nrad 614 614 Step rate, time constant ms 100 100 Step strain, time constant ms 100 100 Minimum angular velocity (2 rad/s 10-4 10-4 Maximum angular velocity rad/s 157 157 Minimum angular frequency (3 rad/s 10-3 10-4 Maximum angular frequency rad/s 628 628 Minimum speed (CSS/CSR) rpm 10-3 10-3 Maximum speed rpm 1500 1500 Maximum temperature range C -40 to 400-40 to 400 SafeGap (Austrian Patent AT 517074), normal force limiter during gap setting - TruRay, dimmable illumination of sample area - Pharmaceuticals Cosmetics Salves and ointments Pastes and creams Emulsions, dispersions and suspensions Shampoos Shower gels Lotions and creams Hair gels Toothpaste Nail polish Makeup Sedimentation Long-term stability Sedimentation Long-term stability curve (ROT) Thermal loop test (OSC) curve (ROT) Thermal loop test (OSC) Connections USB, Ethernet, RS232, analog interfaces, Pt100 port Dimensions mm 380 x 660 x 530 380 x 660 x 530 Weight kg 33 33 QuickConnect for measuring systems, screwless - Toolmaster, measuring system - Toolmaster, measuring cell - CoolPeltier, Peltier-controlled plate system with built-in cooling option that requires no additional accessories for counter-cooling Actively Peltier-controlled hood that requires no additional accessories for counter cooling CoolPeltier, Peltier-controlled cylinder system with built-in cooling option that requires no additional accessories for counter-cooling Virtually gradient-free (horizontal, vertical) temperature control - C 25 below ambient but not lower than -5 up to +200 (4 C -5 to +200 (4 C 15 below ambient but not lower than +5 up to +150 (4 Temperature device Temperature range Materials Measuring systems Heating rate Cooling rate P-PTD 200/AIR/18P -5 C to +200 C Up to Up to Electronic trim lock for the measuring system - Automatic gap control/setting, AGC/AGS - Rheometer software: Test designer - H-PTD 200/AIR/18P -5 C to +200 C Up to Up to Report designer - User management - C-PTD 150/XL/AIR/18P +5 C to +150 C Up to 7 C/min Up to 7 C/min Also available as EDU Edition (for educational institutions only): - MCR 72 or MCR 92 plus accessories with a special academic discount - Free EDU Package and EDU Student Packages including lab equipment and educational material as well as office supplies and giveaways Note: Measuring systems Cone-plate Parallel-plate Concentric-cylinder Double-gap Stirrer 1) Depending on sample properties. 2) Depending on measuring point duration and sampling time, practically any value is achieved. 3) Set frequencies below 10-4 rad/s are of no practical relevance due to the measuring point duration >1 day. 4) System temperature, sample temperature may vary. For measurements at very high or low temperatures a calibration in the sample gap is recommended. RheoCompass (9177015), Toolmaster (3623873) and CoolPeltier (9177056) are registered trademarks of Anton Paar. Legend: included

2018 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. D56IP001EN-D