CHNS Analyser CHNS+O COMBO ANALYSER EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Similar documents
Mining Analyzer XRF-3360

Mining Analyzer XRF-3360

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

FLASH CHROMATOGRAPHY

Compact Liquid Chromatography

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Chemiluminescence Immunoassay System (CLIA) 3001

Analytical Instruments

EPCC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited. An ISO 9001 Certified Company

Atomic Absorption Spectrophotometer AAS PLUS

AutoChem II 2920 A Catalyst Characterization Laboratory

JAPAN QUALITY. Automated Clinical Analyzer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Agilent G2350A Atomic Emission Detector (AED)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Product Description and Specification

Elemental Analysis: CHNS/O characterization of polymers and plastics

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

JAPAN QUALITY. Automated Clinical Analyzer

Your partner in Science!

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

cobas c 111 analyzer Big analyzer performance in a small package

A new chapter. medicacorp.com

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

By Mohsin Al-Saleh Clinical Biochemistry Department (SQUH)

novaa 800 D Atomic Absorption Spectrometer

Elemental Analysis: NCS characterization of paper

ION CHROMATOGRAPHY SYSTEM S 150

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Petrochemical. Transformer Oil Gas Analysis - TOGA

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

473-SHX Dew Point Mirror


HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

13. CARBON AND CARBONATE ANALYSES, LEG 9

SPECTROPHOTOMETERS. Visible and UV-Visible

cobas pro integrated solutions Simplicity meets Excellence

Eppendorf UVette. Instructions for use

Rapid Catalyst Screening Reactors

The Elzone II Particle Count and Size Analyzer

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

Spa & Wellness for Pipettes

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

DR/4000 PROCEDURE. IRON, Total

Carbon (Organic, and Inorganic)

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

CapaciTorr HV Pumps. making innovation happen,together

ChromTech HPLC System

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

Simple Use Compact and Robust Fast and Efficient

UV3000. Accurate, precise, and portable ambient gas point analyzer

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

MicroBrook Eyetech. Particle Size, Shape, and Concentration Analyzer. Particle Sizing. Particle Concentration. Particle Shape

ADVANCED ANALYTICAL LABORATORY

Compact ph Measuring Instruments With Pro Engineering

SIMATIC Ident Industrial Identification Systems

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Introduction to Blackbody Sources

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS)

Spa & Wellness for Pipettes

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Dielectric Analysis of Insulation Liquids

Automated Clinical Analyzer

Introduction to Fourier Transform Infrared Spectroscopy

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

XR Analog Clock - Manual Setting Model Troubleshooting Guide

110 Lowell Rd Hudson, NH USA Tel:

MODERN HPLC FOR PRACTICING SCIENTISTS

Method to 0.50 mg/l NH 3 N Powder Pillows

Fusion UV/Persulfate TOC Analyzer

The Clinical Chemistry System that offers more so you do less!

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

The solution for all of your

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Catalogue. Make communication more convenient! SHENZHEN LIANXUN INDUSTRIES CO.,LTD. Distributed by SHENZHEN LIANXUN INDUSTRIES CO.,LTD.

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Method to 0.50 mg/l NH 3 N Powder Pillows

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

OXITEST Oxidation Test Reactor

On-line XRF analysis of multiple elements in liquid process streams C-QUAND

General. Power requirements: 110/220 Volts 50/60 VAC. Dimensions: Width 80 cm x Height 45 cm x Depth 58 cm. Weight: 57 Kg.

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

POWER + FLEXIBILITY IN ELEMENTAL ANALYSIS

A Novel Approach of Reduction of CO 2 into Methanol by Water Splitting with Aluminum over Copper Catalyst

CapaciTorr HV 200 HIGHLIGHTS

II. WAVELENGTH SELECTION

Thermo Finnigan LTQ. Specifications

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

Transcription:

Turnkey Laboratories Solutions CHNS Analyser CHNS+O COMBO ANALYSER EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company www.analyticalgroup.net

Instrument Principal : CHNS+O Analyzer is a new product, and it is used for oxygen,nitrogen, hydrogen, Carbon, Sulfur determination in ferrous and non-ferrous metals, rare earth materials, alloy, semiconductors, electronic materials, ores, ceramics, coal, graphite, and some organic / inorganic materials. Pulse heating inert gas fusion. O (Oxygen): NDIR(Non Dispersive Infrared absorption); N/H (Nitrogen/Hydrogen): TCD(Thermal Conductivity Detection). Carrier gas (Oxygen) pass through sample extraction unit. Sample combustion at a high temperature, the carbon and sulfur in the sample were converted to CO2 and SO2.and then the mixed gas was measured by infrared detector. The infrared detector using Non-Dispersive-Infrared absorption technology, and it can quickly and accurately measuring carbon & sulfur contents, and it is easy to operate, easy to maintain, easy to repair. Instrument Specification : 1. Structure : Modular Structure, including electronic balance, computer, printer, high-frequency infrared carbon & sulfur analyzer, tubular resistance furnace, vacuum cleaners, water circulate chillers. 2. Detection System : (i) Solid state Infrared detector is used for Oxygen. Thermo-conductivity detector is used for Nitrogen & Hydrogen. (ii) IR Cell: Standard configuration of measure scope is composed of low carbon, high carbon and low sulfur. For specially required scope for sulfur, high sulfur can be added. (iii) Detector: Solid-state pyroelectric detector. (iv) Motor: Synchronous motor made in Swiss, continuously working. (v) IR Emitter: Anti-oxide, stable IR emitter. (vi) Temperature control: Keep constant temperature in the whole infrared unit to make sure the temperature of detected gas to be stable and the results to be accurate. (vii) Protective gas: Controlled gas flow to purify and protect IR emitters and detectors, avoiding the influence of ambient to improve the stability and accuracy. (viii) Thermo-conductivity (TCD) detecting unit: Anti-oxide NTC thermistor (ix) Signal processing: Small current control technique is developed to make sure the thermistors can be used without carrier gas (x) Reference gas circuit: Low flow control technique is used

3. Gas flow control: High sensitive and accurate electric flow control technique based on the low pressure difference is applied, and Anti-Overshoot System is applied. 4. Catalyst unit : a) Catalyst heater: Convert CO to CO2 and SO2 to SO3. b) Filter: SO3 is removed by a filter, to ensure the tail gas reach the requirement of atmospheric environment protection. 5. Dust filter : Made of powdered metal technique, can be reused by washing in ultrasonic cleaner periodically. Cleaning filter and combustion chamber twice during one analysis by special design of the furnace, which reduce the difficulty of daily maintenance. 6. Weighing: Sample mass can be transfer from balance into computer automatically, If necessary, the mass can also be manual input. 7. Analysis time : A typical analysis using induction furnace requires 30-40 seconds. 8. Crucible Ceramic crucible using in induction furnace is 25mm in diameter. 9. Furnace: High frequency induction furnace, 18MHz, Max 2.7KVA, (Temperature: Max.3000 o C) 10. Calibration: 1) Fast calibration 2) Normal calibration 11. Power: 220VAC 10%, 50/60Hz, current max. 50A.

Main Technical Parameters : 1. Range : Oxygen : Low Oxygen : 0.0001% - 0.5%; High Oxygen : 0.5% - 20% Nitrogen : Low Nitrogen : 0.0001% - 0.5%; High Nitrogen : 0.5% - 50% Hydrogen : Low Hydrogen : 0.1ppm~50ppm; High Hydrogen: 20ppm~1000ppm Carbon : Low Carbon : 0.0001% - 0.2% High Carbon : 0.2%- 6% Sulfur : Low Sulfur : 0.0001% - 0.3% High Sulfur : 0.3% - 30% 2. Sensitivity : Oxygen,Nitrogen, Hydrogen, Carbon and Sulfur :0.01ppm 3. Repeatability : Oxygen, Nitrogen and Carbon : 1ppm or 1%; Hydrogen : 0.2ppm or 2% Sulfur : 1.5% 4. Sample mass : 1g (Sample mass can be changed according to the content) 5. Analysis time: about 3 min 6. Carrier gas : High purity helium for O/N, high purity nitrogen for H Oxygen: purity >99.5%, pressure 0.30 MPa, pressure of furnace end 0.05MPa, 3L/min 7. Pneumatic gas: Nitrogen or compressed air Pressure imported 0.30 MPa 8. Structure: Modular Structure, including analyzer, computer, electronic balance*, printer*, water circulate chillers. 9. Chemical reagent: Magnesium perchlorate, Ascarite 10.Electronic balance: Weighing range: 0g-120g. Precision of read: 0.0001g.

Diagnostic Function : 1) Cooling water temperature feedback and display 2) Voltage and current of the furnace feedback and display 3) Catalyst heaters temperature feedback and display 4) Valves action feedback and display 5) IR baseline and TCD baseline adjustment and display 6) Furnace adjustment Software : Software is developed under Window XP. Data display and storage: Analyzing results can be display. Data can be stored into the disk automatically after analyzing. Releasing plot is drawn dynamically. Sample mass can be transfer from balance into computer automatically. Analyzing results are calculated by the calibration curve either in high content channel or in low content channel according to sample content, the selection will be done by software automatically Channels selection: Analyzing results are calculated by the calibration curve either in high content channel or in low content channel according to sample content, the selection will be done by software automatically. Data processing: ACCESS is used as database to manage and store the data. Inquiring, statistic, printing can be done. Data can be sorted by date or name. Releasing plots can be analyzed. Parameters configuration: Parameters of analyzing, flux etc can be setup according to the sample characteristic. Analyzing method with parameters and calibration curve can be established separately according to different samples and can be stored into the database.

Software Interface : Working Curve : Working curve for oxygen Working curve for nitrogen Working curve for hydrogen Working curve for Carbon Working curve for Sulfur Main Analysis Window :

HPLC Servicing, Validation, Trainings and Preventive Maintenance : HPLC Servicing Trainings AMC s/cmc Validations Instruments : We have team of service engineers who can attend to any make of HPLC promptly @the most affordable cost. :We also take up preventive maintenance to reduce downtime of HPLC s Trainings. : We offer user training both in-house and at customer sites on PLC principles, operations, troubleshooting. : We have protocols for carrying out periodic Validations as per GLP/ GMP/U SFDA norms. : We offer instruments/renting Services Modules like pumps, detector etc. on Rent. About Analytical Technologies Analytical Technologies is synonymous for offering technologies for doing analysis and is the Fastest Growing Global Brand having presence in at least 96 countries across the globe. Analytical Technologies Limited is an ISO :9001 Certified Company engaged in Designing, Manufaturing, Marketing & providing Services for the Analytical, Chromatography, Spectroscopy, Bio Technology, Bio Medical, Clinical Diagnostics, Material Science & General Laboratory Instrumentation. Analytical Technologies, India has across the Country operations with at least 4 Regional Offices, 6 Branch Offices & Service Centers. Distributors & Channel partners worldwide. Our Products & Technologies UV/VIS Spectro 2060+ Double Beam FTIR Gas Chromatograph 3000 Gas Chromatograph 2979 Plus Flash Chromatograph Atomic Absorption Spectrophotometer Liquid Partical Counter Optical Emission Spectrophotometer DSC/TGA NOVA 2020 plus Automated Bio Chemistry Analyzer HEMA 2020 Hematology Analyzer Micro Plate Reader/Washer URINOVA 2800 Urine Analyzer Total Organic Carbon Fully Automated CLIA NOVA Basic Semi -Auto Chemistry Analyzer PCR/Gradient PCR/ RTPCR Blood Gas Analyzer Random access Analyzer for immunoassay Proteins & clinical chemistry Semen Analyzer Water purification system

VER.17/12-1 Regulatory compliances Corporate Social Responsibility Analytical Foundation is a Nonprofit Organization (NGO) found for the purpose of: Analytical Foundation 1.Research & Innovation Scientist s awards / QC Professional Award : Quality life is possible by innovation only and the innovation is possible by research only, hence ANALYTICAL FOUNDATION is committed to identify such personallities for their contributions across various field of Science and Technology and awarding them yearly. To participate for award, send us your details of research / testing / publication at info@analyticalfoundation.org 2. Improving quality of life by offering YOGA Training courses, Work shops / Seminars etc. 3. ANALYTICAL FOUNDATION aims to DETOXIFY human minds, souls and body by means of Yoga, Meditation, Ayurveda, Health Care, Awards, Media, Events, Camps etc. Reach us @ Corporate & Regd. Office: Analytical House, # E67 & E68, Ravi Park, Vasna Road, Baroda, Gujarat 390 015. INDIA HPLC Solutions MultipleLabs Analytical Bio-Med Analytical Distributors Analytical Foundation (Trust) T: +91 265 2253620 +91 265 2252839 +91 265 2252370 F: +91 265 2254395 E: info@hplctechnologies.com info@multiplelabs.com info@analyticalgroup.net info@analyticalbiomed.com W. www.ais-india.com www.analycalgroup.net www.hplctechnologies.com www.multiplelabs.com Sales & Support Offices: across the country : Distributors & Channel partners World Wide Note : Company reserves rights to add/delete/modify the contents / technical specifications of the catalogue without prior notice.