Evaluation of Electro/Fenton Process Using Iron Electrode on Phenol Removal from Aqueous Solution

Similar documents
Treatment of Reactive Blue 69 solution by electro-fenton process using carbon nanotubes based cathode

DEGRADATION OF REACTIVE RED 2 BY FENTON AND PHOTO-FENTON OXIDATION PROCESSES

Photolytic Degradation of Rhodamine B in Water Using H 2 O 2 /UV System

Characteristics of Fenton s Oxidation of 2, 4, 6 Trichlorophenol

Oxidation of Phenolic Wastewater by Fenton's Reagent

Supporting Information. for

Decomposition of sodium dodecylbenzene sulfonate surfactant by Electro/Fe 2+ -activated Persulfate process from aqueous solutions

How can oxidation be done

Photochemical Treatment of Amido Black - 10B Waste Water by Photo-Fenton Reagent

Chapter - III THEORETICAL CONCEPTS. AOPs are promising methods for the remediation of wastewaters containing

The calculation of kinetic parameters would be an integral part of the report.

DEGRADATION OF PHENOL BY CATALYTIC OZONATION

Degradation of phenol with using of Fenton-like Processes from water

JRHS Journal of Research in Health Sciences

Investigation on dyes oxidation by Fenton s reagent in aqueous medium

CHEMICAL OXIDATION. The use of oxidizing agents without the need of microorganisms for the reactions to proceed

Treatment of the azo dye in the solution by fenton-sbr process

Decolorized of Textile dye waste waters by Hydrogen peroxide, UV and Sunlight

PHOTOCHEMICAL OXIDATION OF p-aminophenol BY FENTON REAGENT

REMOVAL OF REACTIVE YELLOW DYE USING NATURAL COAGULANTS IN SYNTHETIC TEXTILE WASTE WATER

Comparison on Degradation of Reactive Black 5 (RB5) in Photocatalytic Fuel Cell (PFC) under UV and Solar Light

Decolouring of Synthetic Waste Water by Chemical Oxidation

Chemical Oxidation Oxidizing agents

Box Behnken modelling of phenol removal from aqueous solution using Emulsion Liquid Membrane

Thermal Gravimetric Analyzer (TGA) ก TiO 2 /AC

Microwave and Fenton s reagent oxidation of wastewater

ROLE OF COPRECIPITATED NiS-ZnS IN PHOTOCATALYTIC DEGRADATION OF ALIZARIN RED S

PEROXIDASE CATALYZED THE REMOVAL OF PHENOL FROM SYNTHETIC WASTE WATER

Kinetic Study on COD Removal of Palm Oil Refinery Effluent by UV-Fenton

EFFECT OF SULFATE IONS ON THE OXIDATION OF MTBE BY FENTON S REAGENT

Electrochemical Oxidation of Acid Yellow and Acid Violet Dyes Assisted by Transition Metal Modified Kaolin

Supporting Information

Phenols removal using ozonation-adsorption with granular activated carbon (GAC) in rotating packed bed reactor

Sawsan Mohamed Abu El Hassan Mosa

A comparative study of the azo dye reactive black 5 degradation by UV/TiO 2 and photo-fenton processes

Effect of silver nano particle, ferrous sulfate and hydrogen peroxide on photodgradtion of Tornasole RPe and Alizarin yellow G

Development of Environmentally Friendly Modified Fe-PAN Fibrous Catalyst and Its Application in Degradation of Dye

PHENOL DEGRADATION: NUMERICAL SIMULATION IN A STIRRED TANK ELECTROCHEMICAL REACTOR

Sequence-Fenton Reaction for Decreasing Phenol Formation during Benzene Chemical Conversion in Aqueous Solutions

Electronic Supplementary Information

Effect of Composition and Mass Ratio on the Catalytic Wet Air Oxidation Catalyst Cu Fe La/FSC

Kinetic studies using UV-VIS spectroscopy Fenton Oxidation

Oxidation of Pentachlorophenol by Fenton s Reagent

COMPARISON STUDY OF CONGO RED DYE DEGRADATION PROCESS USING FENTON S REAGENT AND TiO2

CE 370. Disinfection. Location in the Treatment Plant. After the water has been filtered, it is disinfected. Disinfection follows filtration.

Fe/C CATALYSTS FOR HETEROGENEOUS FENTON TREATMENT OF PHENOL IN AQUEOUS PHASE

International Conference on: Pollution Control & Sustainable Environment

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

PREPARATION, CHARACTERISATION AND PHOTOCATALYTIC ACTIVITY OF TERNARY GRAPHENE-Fe 3 O 4 :TiO 2 NANOCOMPOSITES

Moringa oleifera: A COST EFFECTIVE COAGULANT FOR DYE DEGRADATION

DEGRADATION OF FAST GREEN FCF USING IMMOBILIZED PHOTO-FENTON REAGENT

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Degradation of Bisphenol A by Peroxymonosulfate Catalytically Activated with. Gui-Xiang Huang, Chu-Ya Wang, Chuan-Wang Yang, Pu-Can Guo, Han-Qing Yu*

Reaction Rate Constants for Hydrogen Peroxide Oxidation of Phenol and Chlorinated Phenols in a Continuous Stirred Tank Reactor

we might also expect the reaction rate to be influenced by ph. In fact, the rate has been reported to follow the rate law:

Oxygen Demand, Chemical

Oxygen Demand, Chemical

Research Article. Phenol degradation using microwave irradiation

Chemical Oxidation and Reduction

Removal of Crystal Violet from Aqueous Solution by Activated Biocharfibers. Maria A. Andreou and Ioannis Pashalidis

Heterogeneous Fenton process using steel industry wastes for methyl orange degradation

Lesson Aiming for 4 Aiming for 6 Aiming for 8. I can use the periodic table to find the relative atomic mass of all elements.

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Hydrogen production by electrolysis. Ann Cornell, Department of Chemical Engineering, KTH

Techniques for effluent treatment. Lecture 5

Journal of Innovative Engineering R Senthilkumar et al., Journal of Innovative Engineering 2014, 2(2): 5

LlkJ-/ rpdf Pollution Prevention - Source Reduction with Electrodialytic Processes

Enhanced Ozonation of Phenol in Water

Physico-chemical treatment for the depuration of wine distillery wastewaters (vinasses)

Volume 8, ISSN (Online), Published at:

Smith-Palmer Chemistry 265 Analytical and Environmental 2010

Evaluation of Nitrate Removal from Water Using Activated Carbon and Clinoptilolite by Adsorption Method

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

MASS TRANSFER AND ADSORPTION OF AMOXICILLIN FROM WASTEWATER USING WHEAT GRAIN

Catalytic ozonation of pentachlorophenol in aqueous solutions using granular activated carbon

Studies on the preparation of Caro s acid by ultrasonic enhanced electrochemistry

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Removal of Cd (II) and Cr (VI) from Electroplating Wastewater by Coconut Shell

Name AP CHEM / / Collected Essays Chapter 17

Application of TiO 2 /UV-C Photocatalytic Process in Removal of Reactive Red 198 Dye from Synthetic Textile Wastewater

Journal of Chemical and Pharmaceutical Research

Copper electrodeposition in presence and absence of EDTA using reticulated vitreous carbon electrode

Catalytic wet oxidation of phenol and its derivatives with Fe 2 O 3 and MnO 2

The electrolysis of sodium chloride solution produces useful substances. covalent ionic non-metallic

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Chemical modification of graphite felts for efficient H 2 O 2 production: Influence of operational parameters

Chemistry 1011 TOPIC TEXT REFERENCE. Electrochemistry. Masterton and Hurley Chapter 18. Chemistry 1011 Slot 5 1

Photochemical treatment of rhodamine-b wastewater by photo-fenton reagent

The Effect of Aeration and Hydrogen Peroxide on the Electrochemical Degradation of Methylene Blue Using Carbon Composite Electrodes

Extraction Behaviour of Cu 2+ Ions with Used Cooking Oil-Based Organic Solvent

Tanks in Series Model for Continuous Stirred Tank Electrochemical Reactor

AC VERSUS DC STRAY CURRENT CORROSION, ANALYSIS AND MEASUREMENT

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

LAB 05 Enzyme Action

REMEDIATION OF SALT IMPACTED GROUNDWATER WITH ELECTROKINETICS. Paper by: Sean Kelly, Rick Churko, Sean Frisky, Anjum Mullick, Stuart Torr.

Experiment 16. Desalination of Sea Water E16-1

Degradation of Organophosphorus Pesticides in Water during UV/H 2 O 2 Treatment: Role of Sulphate and Bicarbonate Ions

Physicochemical Processes

Electrochemical wastewater treatment: applications and scale-up

Removal of Anionic Surfactants from Industrial And Domestic Waste Water Using a Bio Adsorbent Embelia Ribes in Region Bilaspur Chhattisgarh, India

Transcription:

ISBN 978-93-84422-80-6 13th International Conference on Chemical and Environmental Sciences (ICCES-2017) Pattaya (Thailand) Dec. 28-29, 2017 Evaluation of Electro/Fenton Process Using Iron Electrode on Phenol Removal from Aqueous Solution Alireza. Rahmani, Halime. Almasi and Fahime. Zamani Department of Environmental Health Engineering, Faculty of Health and Research Center for Health Sciences, Hamadan University of Medical Science, Hamadan, Iran E-mail: rah1340@yahoo.com, h.almasi14@yahoo.com, f.zamani2016@yahoo.com Abstract: This study examines phenol removal from aqueous solutions through electro-fenton (EF) process using iron electrode. The effect of operational parameters such as initial ph, current density, initial concentration of phenol, hydrogen peroxide dosage on the removal of phenol was investigated. The results showed that the efficiency of phenol removal had a direct relationship with initial concentration of hydrogen peroxide, and was inversely correlated with the highly alkaline ph and elevated concentration of phenol. The removal efficiency of phenol was significantly increased with increasing H2O2 concentration from 0.1 mm to 0.4 mm, but there was little influence on the removal efficiency in greater quantities of H2O2. Ultimately, phenol was almost completely removed after 45 min in this process. Keywords: Electro Fenton, Phenol removal, Oxidation process, Iron electrode. 1. Introduction One of the greatest concerns of the 21st century is water shortage. The shortage of the fresh water affects more than 25% of the world population. Consequently, 2.2 million people die every year as reported by the World Health Organization. On the other hand, a large amount of water is contaminated by domestic and industrial activities in developing countries. Therefore, evaluation of waste water quality is essential to avoid further contamination of the environment. The need for reuse of water resources is important in order to reduce fresh water consumption [1]. Overpopulation and the consequent increase of industrial activities generate high concentrations of pollutants leading to aquatic environment contamination. For example, phenol and its derivatives can be found in waste disposal of various industries including resins, plastics, paper-making and coal conversion factories. Although the toxicity and environmental impact of phenolic compounds depend on the number, type and the position of substitution groups of aromatic compounds, these chemicals is found to be toxic for various organisms, including humans, animals and plants. Hence, the removal of phenolic compounds is regarded as one of the greatest concerns in the world [3, 2]. There are several methods of treating wastewater containing phenol and the most important of these are advanced oxidation, chemical oxidation, adsorption, biological, filtration and a combination of these procedures [4]. High cost, long retention time and generation of toxic by-products are drawbacks to the widespread use of some of these elimination strategies [5, 6]. Advanced oxidation processes have attracted much attention today due to their ease of use, being economical and high efficiency [7-9]. Among the advanced oxidation processes, Electro/Fenton process can be noted. Fenton process is a process which Fe2+ ions and hydrogen peroxide are concurrently used to decompose and eliminate pollutants. This process is possible in the presence of Fe2+ ions, hydrogen peroxide and radical hydroxyl for oxidation to take place. H2O2 can be activated by Fe2+ to produce hydroxyl radical via Eq. (1). H 2 O 2 + Fe 2+ Fe 3+ + OH + OH - (1) https://doi.org/10.17758/erpub.1217004 199

If in the Fenton process, the Fe 2+ ions produce by electrolytic method using iron electrode, it is called electrofenton (EF) process. This process has attracted much attention due to its characteristics such as low cost, easy operation, and high efficiency [10]. It has been proven that various types of organic compounds can be degraded by the Fenton process without producing any toxic substances in the aquatic environment. The whole process is very efficient and cost-effective compared to conventional chemical methods [11, 12]. If Fe 2+ is produced by electrochemical method, its concentration will be low level and quenching of radicals does not occur. In the current study removal of phenol using electrofenton process was examined. The effect of different parameters was also evaluated in this process. 2. Materials and Methods 2.1. Materials All chemicals, such as peroxide hydrogen (H2O2), phenol with 99.5% purity (C6H5OH), sulfuric acid (H2SO4), were purchased from Merck Company. Phenol absorbance measurement was accomplished by using UV Vis Spectrophotometer and ph was measured using a ph meter manufactured by HACH Company. 2.2. Methods A known amount of the phenol solution (100 mgl-1) was poured to the reactor. Distillated water was used to prepare solutions. Adjusting of solution ph was performed using sulfuric acid (1 N) and NaOH (1N). After regulating of the voltage, hydrogen peroxide dosage, the iron electrodes were placed into the reactor and the run was done. Sampling was carried out at different times and then the samples were centrifuged (6000 RPM for 10 min) and absorption amounts of the remaining phenol in the samples were measured through direct photometry by using UV-Vis spectrophotometer at a wavelength of 500 nm [13,14]. The removal efficiency of phenol was calculated as follows [15]. 2.3. Bench Scale Reactor This experimental study was conducted using a batch processing reactor in water and wastewater laboratory in Hamadan University of Medical Sciences. The intended bench scale reactor whose schematic representation is given in Fig. 1 was made of a glass beaker with the volume of 1000 ml. Four iron electrodes each 200 mm length, 20mm width and 2 mm thickness at a distance of 1 cm are floating in the reactor. The electrodes are connected to a DC power supply so that cathode and anode were placed alternately. A magnetic stirrer is used in order to create a uniform mixing of the solution. Fig. 1. Experimental Setup for EF Process: 1. DC power supply, 2. Stirrer 3. Anode, 4. Cathode, 5. Electrochemical cell. https://doi.org/10.17758/erpub.1217004 200

3. Results and Discussion 3.1. Effect of ph Fenton process is heavily dependent on ph solution [16]. In this study, the effect of ph changes in the range of 3-10 in EF process was studied and the results are shown in Fig. 2. Results indicate that the ph changes are fairly significant in phenol removal, so that the highest removal efficiency in ph = 3 was 93.99 %. ph has a direct effect on the stability of H 2 O 2, the amount of producing OH, and finally determines the type and state of iron in the solution [17-19]. Studies have shown the oxidation potential of OH increases as ph decreases [12, 20]. As mentioned the maximum percentage of phenol removal occurred at ph= 3 because of in acidic ph the surface of iron over time would be refreshed so production of free electron can be faster than other ph [21]. Also the lowest phenol removal efficiency was observed at ph= 10. In alkaline ph Fe 2+ precipitate to the form of Fe (OH) 2 and leaves the catalytic cycle. Fig. 2. Effect of ph on removal of phenol in EF process ([phenol] 0 = 100 mg.l -1, [H 2 O 2 ] 0 =0.4 mm and CD= 0.17 ma cm -2 ) 3.2. Effect of Current Density In all electro-chemical processes, current density (CD) is the main parameter to control the reaction rate [22]. According to Faraday's law, intensifying the applied current, increases producing metal ions on a sacrificial anode surface [22]. In most electrochemical studies a constant current density was used or potential difference was fixed [23]. To control the effect of iron concentration on the process, constant current density enters the electrode that iron can be produced at a constant rate by sacrificial anode and the system can be steered under controlled condition [24]. Increasing current density results a rapid ferrous generation and ferric reproduction so phenol removal efficiency soars [12, 25]. When the current density in the process increases from 0.12 to 0.17 ma.cm -2 phenol degradation increases from 47.54 to 93.18%. This would in turn boost the efficiency of phenol removal, so that the maximum phenol removal efficiency is observed when the current density is 0.17 ma.cm -2. As a result, according to Fig. 3 in the current density of 0.24 ma.cm -2 phenol removal efficiency has declined. 3.3. Effect of Hydrogen Peroxide Dosage In order to determine the optimal dosage of hydrogen peroxide, different H 2 O 2 values in the range of 0.1-0.5 mm was added to each prepared sample and the ph was set to 3, and then the experiment was performed. The amount of hydrogen peroxide is the main factor affecting operation cost and process efficiency [6]. According to Fig. 4 phenol removal efficiency in this process will increase with increasing hydrogen peroxide concentration from 0.1 to 0.4 mm, from 49.71 % to 93.18%. It was noted that H 2 O 2 is the only source of OH in the process. Increasing the amount of H 2 O 2 to a certain extent increases OH concentration and will increase the process efficiency [26]. By increasing H 2 O 2 concentration as much as 0.5 mm, an opposite trend was observed in the removal of phenol. When hydrogen peroxide concentration escalates, it is converted into oxygen and water and hydroxyl radicals are combined together, which is followed by a decline in the process efficiency. https://doi.org/10.17758/erpub.1217004 201

Fig. 3. Effect of different current densities on phenol removal efficiency ([phenol] 0 = 100 mg.l -1, [H 2 O 2 ] 0 =0.4 mm and ph = 3) Fig. 4. Effect of different hydrogen peroxide concentrations in EF process ([phenol] 0 = 100 mg.l -1, ph = 3 and CD= 0.17 ma.cm -2 ) 3.4. Effect of Phenol Concentration Effect of phenol initial concentration in the process was examined in the range of 50-200 mg.l -1 that the results illustrated in Fig. 5. The figure shows that with increasing of phenol concentration from 50 to 200 mg.l -1, removal efficiency decreases from 93.18 to 15% after 45 minutes. It is clear that increasing the initial concentration of pollutants, needs more oxidant so in the constant amount of oxidant the efficiency of the process would be decreased. The intermediate compounds generated during the reaction would be rise in high initial concentration which consume hydroxyl radicals. This may lead to competition between pollutant molecules and intermediate in reacting with hydroxyl radicals. Thus decomposition rate drops in high initial concentrations [26]. Fig. 5. Effect of phenol initial concentrations on EF process in optimal conditions efficiency ([phenol] 0 = 100 mg.l -1, [H 2 O 2 ] 0 = 0.4 and mm ph = 3) 4. Conclusion The present study investigates EF process using iron electrode. In the optimum condition removal efficiency of this process was obtained 93.18%. The results showed that phenol removal efficiency has a direct relationship with an increase in contact time and current density and had an inverse relationship with phenol initial concentration. Phenol removal efficiency is reduced when hydrogen peroxide concentration is much more than the optimum level. To reach the maximum efficiency, electrolyte and electrical current density must be present. https://doi.org/10.17758/erpub.1217004 202

5. Acknowledgment This research was sponsored by the Research Department of Hamadan University of Medical Sciences. The researchers express their heartfelt gratitude to everyone involved in this study. 6. References [1] B. Bayarri, M. I. Maldonado, J. Giménez, S. Esplugas and O. González, J. Sol. Energy Eng., 129, 60 (2007). [2] P. S. González, E. Agostini and S. R. Milrad, Chemosphere, 70 982 (2008). [3] L. Jiang and M. Xuhui, Int. J. Electrochem. Sci., 7 4078 (2012). [4] D.H. Bremner, A.E. Burgess, D. Houllemare, K.-C. Namkung, Appl. Catal. B: Environ., 63, 15(2006). [5] K. Verschu eren, Handbook of environmental data on organic chemicals,.wiley, 2001. [6] J. Virkutyte and V. Jegatheesan, Bioresour. Technol., 100, 2189 (2009). [7] F. J. Beltrán, F. J. Rivas and R. Montero-de-Espinosa, Water Res., 39, 3553 (2005). [8] B. Kasprzyk- Hordern, M. Ziółek and J. Nawrocki, Appl. Catal. B; Environ., 46, 639(2003). [9] T. Sreethawong and S. Chavadej, J. Hazard. Mater., 155 486 (2008). [10] W. P. Ting, M. C. Lu and Y. H. Huang, J. Hazard. Mater., 156, 421 (2008). [11] H. Liu, X. Z Li, Y. J. Leng and C. Wang, Water Res., 41, 1161 (2007). [12] J. Wu, H. Zhang and J. Qiu, J. Hazard. Mater., 215, 138(2012). [13] Y. T. Lin, C. Liang and J. H. Chen, Chemosphere., 82, 116 (2011). [14] S. Gao, J. Yang, J. Tian, F. Ma, G. Tu, and M. Du, J. Hazard. Mater., 177, 336 (2010). [15] Y. S. Ng, N. S. Jayakumar and M. A. Hashim, Desalin. Water Treat., 278, 250 (2011). [16] A. Babuponnusami and K. Muthukuma, J. Chem. Eng., 2, 557 (2013). [17] M. R. Samarghandi, A. Shabanloo, K. Shamsi, J. Mehralipour and Y Poureshgh, IJEHSE, 4, 293 (2014). [18] M. Malakotian, M. Asadi and A.Mahvi, Iran J. Health. Environ., 5, 1 (2013). [19] E. Basturk, M. Karatas, Ultrason. Sonochem., 21, 1881 (2014). [20] S. Vinodha, S. Babithesh and P. Jegathambal, IBM J. Res. Dev., 5, 45 (2012). [21] A. R. Rahmani, M. Zarrabi, M. R. Samarghandi, A. Afkhami and H. R. Ghaffari, Iran J Chem Eng., 7, 87 (2010). [22] J.B. Parsa, H.R. Vahidian, A. Soleymani, M. Abbasi, Desalination, 278, 295 (2011). [23] B. Boye, M. M Dieng and E. Brillas, Environ. Sci., 36, 3030 (2002). [24] A. Bagheri,GH. Moussavi GH, and A. Khavanin, IJEHSE. 2, 143 (2012). [25] B. Kayan, B. Gözmen, M. Demirel and A. M. Gizir, J. Hazard. Mater., 177, 95 (2010). [26] H. Sheme and K. G. & Linden, J. Hazard. Mater., 136, 553 (2006). https://doi.org/10.17758/erpub.1217004 203