Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations

Similar documents
Unsteady Flow of a Newtonian Fluid in a Contracting and Expanding Pipe

Biomagnetic Steady Flow through an Axisymmetric Stenosed Artery

Effect of body acceleration on pulsatile blood flow through a catheterized artery

Effect of Magnetic Field on Blood Flow (Elastico- Viscous) Under Periodic Body Acceleration in Porous Medium

Modeling of non-newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction

Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity

Research Article FDM Analysis for Blood Flow through Stenosed Tapered Arteries

A Computational study of Bingham plastic flow of Blood through an artery by multiple stenoses and post dilatation

Effect of Magnetic Field on Flow Behaviour of Blood through A Modelled Atherosclerotic Artery

Analytical Solutions of Unsteady Blood Flow of Jeffery Fluid Through Stenosed Arteries with Permeable Walls

Effect of Periodic Body Acceleration in Blood Flow through Stenosed Arteries A Theoretical Model

Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

Arterial Macrocirculatory Hemodynamics

Research Article Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study

World Journal of Engineering Research and Technology WJERT

Numerical Study of Blood Flow through Symmetry and Non- Symmetric Stenosis Artery under Various Flow Rates

Impact of Magnetic Field Strength on Magnetic Fluid Flow through a Channel

STUDY OF BLOOD FLOW THROUGH MODELLED VASCULAR STENOSIS

31545 Medical Imaging systems

Pulsatile Flow of Couple Stress Fluid Through a Porous Medium with Periodic Body Acceleration and Magnetic Field

Available online at Pelagia Research Library. Advances in Applied Science Research, 2012, 3 (6):

Flow of a Casson Fluid Through an Inclined Tube of Non-uniform Cross Section with Multiple Stenoses

Numerical Study on Sinusoidal Fluctuated Pulsatile Laminar Flow Through Various Constrictions

Effect of variable viscosity on the peristaltic flow of a Jeffrey fluid in a uniform tube

Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis

TECHNISCHE UNIVERSITEIT EINDHOVEN Department of Biomedical Engineering, section Cardiovascular Biomechanics

MHD Pulsatile Slip Flow of Blood through Porous Medium in an Inclined Stenosed Tapered Artery in Presence of Body Acceleration

SIMULATION OF ARTERIAL STENOSIS INCORPORATING FLUID-STRUCTURAL INTERACTION AND NON-NEWTONIAN BLOOD FLOW

Numerical Simulation of Sinusoidal Fluctuated Pulsatile Laminar Flow Through Stenotic Artery

University of Washington Department of Chemistry Chemistry 453 Winter Quarter 2013

INSTABILITY, TRANSITION AND RECEPTIVITY OF PULSATILE FLOW IN A STENOTIC TUBE

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Two dimensional model of pulsatile flow of a dusty fluid through a tube with axisymmetric constriction

V (r,t) = i ˆ u( x, y,z,t) + ˆ j v( x, y,z,t) + k ˆ w( x, y, z,t)

arxiv: v1 [physics.flu-dyn] 16 May 2014

Numerical Study of the Behaviour of Wall Shear Stress in Pulsatile Stenotic Flows

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Numerical simulation of steady and unsteady flow for generalized Newtonian fluids

Modelling and simulation of micropolar fluid flow with variable viscosity through unhealthy artery

Numerical modelling of shear-thinning non-newtonian flows in compliant vessels

Analysis and Simulation of Blood Flow in MATLAB

Numerical Simulation of Newtonian and Non-Newtonian Flows in Bypass

PROBLEM SET 6. SOLUTIONS April 1, 2004

MHD OSCILLATORY SLIP FLOW AND HEAT TRANSFER IN A CHANNEL FILLED WITH POROUS MEDIA

Experimental and Theoretical Investigation of Hydrodynamics Characteristics and Heat Transfer for Newtonian and Non-newtonian Fluids

Multiscale Hydrodynamic Phenomena

Oscillatory flow of a jeffrey fluid in an elastic tube of variable cross-section

Numerical and Experimental Investigation of Hemodynamics of Blood Flow through Realistic Stenosis

Magnetic effects on pulsatile flow of micropolar fluid through a bifurcated artery

Experimental Investigation on Characteristics of Non- Newtonian Fluids

Numerical study of blood fluid rheology in the abdominal aorta

MHD peristaltic transport of a micropolar fluid in an asymmetric channel with porous medium

Blood flow through arteries in a pathological state: A theoretical study

Pulsatile Flow in a Tapered U-Tube

PULSE WAVE PROPAGATION IN LARGE BLOOD VESSELS BASED ON FLUID-SOLID INTERACTIONS METHODS

Mathematical Model. M. Umar Qureshi, Mitchel J. Colebank, and Mette S. Olufsen

Peristaltic Pumping of a Casson Fluid in an Elastic Tube

Peristaltic flow of a Williamson fluid in an inclined planar channel under the effect of a magnetic field

Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka , India

OPTIMAL DESIGN OF CLUTCH PLATE BASED ON HEAT AND STRUCTURAL PARAMETERS USING CFD AND FEA

Basic Fluid Mechanics

Week 8. Topics: Next deadline: Viscous fluid flow (Study guide 14. Sections 12.4 and 12.5.) Bolus flow (Study guide 15. Section 12.6.

Mathematical Model of Blood Flow in Carotid Bifurcation

BME 419/519 Hernandez 2002

Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis

Navier-Stokes Flow in Cylindrical Elastic Tubes

Mathematical Modeling of Peristaltic Flow of Chyme in Small Intestine

TABLE OF CONTENTS CHAPTER TITLE PAGE

Numerical simulation of blood flow in a straight artery under the influence of magnetic field

STEADY VISCOUS FLOW THROUGH A VENTURI TUBE

Magnetic Effect on Slip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration

Analytical Solutions on the Flow of blood with the Effects of Hematocrit, Slip and TPMA in a porous tube

PREDICTION OF PULSATILE 3D FLOW IN ELASTIC TUBES USING STAR CCM+ CODE

Convective instability and transient growth in steady and pulsatile stenotic flows

Determination of pressure data in aortic valves

STEADY AND UNSTEADY 2D NUMERICAL SOLUTION OF GENERALIZED NEWTONIAN FLUIDS FLOW. Radka Keslerová, Karel Kozel

Heat and Mass Transfer Effects of Peristaltic Transport of a Nano Fluid in Peripheral layer

ABSTRACT. Keywords: Magnetic field; porous medium; stenosed artery; unsteady blood flow ABSTRAK

Pressure in a fluid P P P P

10/9/2017 LET S PERFORM 4 EXPERIMENTS: UNIT 1 FLUID STATICS AND DYNAMICS CHAPTER 11 FLUIDS IN MOTION SNORING BERNOULLI'S PRINCIPLE

REE Internal Fluid Flow Sheet 2 - Solution Fundamentals of Fluid Mechanics

International Journal of Mathematical Archive-7(5), 2016, Available online through ISSN

Lab Section Date. ME4751 Air Flow Rate Measurement

Effect on the Flow of Bile Due to Radially Varying Viscosity in the Cystic Duct

PhD Course in Biomechanical Modelling Assignment: Pulse wave propagation in arteries

Fluid Mechanics II Viscosity and shear stresses

THERE are several types of non-newtonian fluid models

CFD SIMULATIONS OF FLOW, HEAT AND MASS TRANSFER IN THIN-FILM EVAPORATOR

Lattice Boltzmann Simulation of One Particle Migrating in a Pulsating Flow in Microvessel

Magnetic Drug Targeting in Cancer Therapy

Non-invasive Measurement of Pressure Gradients in Pulsatile Flow using Ultrasound

Non-Newtonian blood flow in human right coronary arteries: steady state simulations

A monolithic approach to fluid-composite structure interaction

Doppler Imaging: The Basics

SYMMETRY BREAKING PHENOMENA OF PURELY VISCOUS SHEAR-THINNING FLUID FLOW IN A LOCALLY CONSTRICTED CHANNEL

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Hussain, B; Wong, EY; Yiu, BYS; Yu, ACH; Poepping, TL. IEEE Ultrasonics Symposium. Proceedings. Copyright IEEE.

Elec Eng 3BA3: Structure of Biological Materials

Study of blood flow through a catheterized artery

2. FLUID-FLOW EQUATIONS SPRING 2019

Transcription:

International Journal of Mathematics And its Applications Volume 4, Issue 3 B (216), 37 43. ISSN: 2347-1557 Available Online: http://ijmaa.in/ International Journal 2347-1557 of Mathematics Applications And its ISSN: International Journal of Mathematics And its Applications Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations Research Article Neeta D.Kanane 1,2 and N.S.Bode 2 1 Department of Mathematics, Maharashtra Institute of Technology, Pune, India. 2 Department of Mathematics, Dr.B.N.P.Arts, S.S.G.G.Commerce & Science College, Lonavla, Pune, India. Abstract: The paper studies the flow of blood through a stenosed artery in the presence of body accelerations. The mathematical model is constructed by considering blood to be a Newtonian fluid. The artery is assumed to have axisymmetric shape. The shape of stenosis is time dependent. The present paper calculates both radial and axial velocities. The governing blood flow equations are solved using finite difference approximation numerically and radial variation of axial and radial velocities is discussed. These velocities are plotted for different times. Keywords: Axial velocity, radial velocity, Body acceleration. c JS Publication. 1. Introduction One of the most serious problem related with biological fluid flow in human body is narrowing of arteries due to deposition of fatty material inside it. Blood flow in the human circulatory system depends upon the pumping action of the heart, which creates a pressure gradient throughout the system. But in many situations of day to day life such as driving a vehicle, flying in an aircraft etc. human body may be subjected to vibratory or acceleratory motion. Prolonged acceleration may cause various physical disorders lie headache, increase in pulse rate etc. Hence it is important to study the pulsatile blood flow under the action of body acceleration. Mandal P. K et al [1] studied the effect of body acceleration on unsteady pulsatile flow of non-newtonian fluid through stenosed artery. Charavarty S. et al [2] presented non-linear mathematical model in constricted artery. They observed the blood flow in the presence of body accelerations. The paper presented the unsteady behaviour of blood treating blood as non-newtonian fluid. The laminar pulsatile flow of blood under the influence of externally imposed body accelerations was studied by J.C.Mishra et.al [3]. They have developed the model by treating blood as a non -Newtonian fluid using biviscosity model. The governing equations are solved using finite difference technique. The mathematical model to study the characteristic of blood flowing through an arterial segment in the presence of a couple of stenoses with surface irregularities was developed by N.Mustapha et.al [4]. They have solved governing equations numerically by MAC (Marer and Cell) method in cylindrical polar coordinate system in staggered grids. Charavarty. S, Mandal P. K [5] studied blood flow in tapered arteries in the presence of stenosis. The paper analysed the effects of tapering, arterial wall motion and the pressure E-mail: bode.nitin@gmail.com 37

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations gradient on the blood flow characteristic. This present paper attempts to study radial variation of axial as well as radial velocity of blood under the diseased conditions. Finite difference scheme involving central differences is implemented to solve governing equations. Effect of body acceleration on axial velocity is studied and it is compared with blood flow velocity in the absence of body acceleration. 2. Governing Equations We consider the stenotic blood flow experiencing body accelerations to be unsteady, axisymmetric and laminar. The basic equations of motion governing such flow may be written as ( u ρ ρ u r + u r + = (1) ) = p ( 2 r + µ u r + 1 u 2 r r u ) r + 2 u (2) 2 2 ) = p ( 2 + µ w r + 1 ) 2 r r + 2 w + B (t) (3) 2 + u u r + w u ( + u r + w Where r, z are radial and axial directions. u and w are velocity components along radial and axial directions respectively. ρ and µ are density and viscosity of blood, p is the pressure.the pressure gradient p is due to the pumping action of the heart which is given by p = A + A1cos ωt, Burton. A. C [6]. Where A is taen as the constant amplitude and A1 is the amplitude of the pulsatile component which gives rise to systolic and diastolic pressure. Here w = 2πf p, where f p is pulse frequency. B (t) is the periodic body acceleration in axial direction which have been made use of Sanar D.S [7], given by B (t) = r cos (w pt + ), t. Where r is its amplitude, w p = 2πf p, f p is its frequency and is its phase difference. 3. The Geometry of Stenosis Young D. F [8] described the time dependent geometry of the stenosis as a 1 (t) { a τm R (z, t) = [1 + cos {π(z l1)/l} ]}, d < z < d + 2l 2 aa 1 (t), Otherwise. Where a 1(t) = 1+ K Rcos(ωt ) in which ω is angular frequency, is the phase difference and K R is a constant. l 1 is the centre of the stenosis, l o is the half length of the stenosis region, τ m is the maximum height of the stenosis and a is the radius of artery in non stenotic region. Figure 1: The geometry of the stenosis in an artery 38

Neeta D.Kanane and N.S.Bode 4. Boundary Conditions The velocities at the inlet and outlet of an arterial segment of finite length are taen as Sarifuddin et al [9] u (r, z, t) = and w (r, z, t) = 5 3 ( 1 ( r ) ) 3 R(z, t) at z = (4) (r, z, t) = = u (r, z, t) at z = L (5) It is assumed that initially radial and axial velocity both are zero. That is when system is at rest there is no flow through artery. That is u (r, z, ) =, w (r, z, ) = (6) Axially, there is no radial flow, therefore the radial velocity is zero and the axial velocity gradient of the blood may be assumed to be equal to zero. This may be stated as r =, u (r, z, t) = on r = (7) On the artery wall the axial velocity is zero due to no slip condition and radial velocity is rate of change in shape of the stenosis which is written as w (r, z, t) =, u (r, z, t) = R on r = R(z, t) (8) 5. Numerical Method and Implementation Equations (1), (3) along with boundary conditions (4)-(8) tae the form after introducing radial co-ordinate transformation, x = r R (z, t) = 1 [ ( x w R R + R 1 u R x + u xr + ) ] u x R R x w + µ ρr 2 u (x, z, t) = and w (x, z, t) = 5 3 x = (9) ( 2 w x + 1 ) 1 p + B (t) 2 x x ρ (1) ( 1 x 3 ) at z = (11) (x, z, t) = = u (x, z, t) at z = L (12) x u (x, z, ) =, w (x, z, ) = (13) =, u (x, z, t) = on x = (14) w (x, z, t) =, u (x, z, t) = R Multiplying equation (9) by xr and integrating w.r.t. x within limits to x. on x = 1 (15) x u x dx + u dx + xr dx x 2 R dx = (16) x Which gives us u (x, z, t) = xr R x x dx 2 R x xw dx (17) 39

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations Now, using boundary condition (11), we will get 1 x dx Here, choice of f(x) is arbitrary. Let f (x) be of the form f(x) = 1 3 between the integrals to integrands, we will get Using this in equation (17), 1 [ 2 R x R w + 1 ] R R f (x) dx = (18) = 2 R R w + 1 R ( x 3 1 ) 3R u (x, z, t) = xw R +.3333 R ( ) 1 x 3 satisfying 1 xf (x) dx = 1. Considering equality ( 5x 2x 4 ) (19) Solving equation (1) using finite difference approximations in which central differences have been used. x = w i,j+1 wi,j 1 2 x = w i+1,j wi 1,j 2 z = w+1 i,j wi,j t 2 w x 2 = w i,j+1 2wi,j + w i,j 1 ( x) 2 Where x j = (j 1) x, z i = (i 1) z and t = ( 1) t. x, z are increments in radial and axial directions respectively. w +1 i,j = w i,j + t µ + ρ ( Ri { 1 ρ ( ) +1 p wi,j ) 2 [ w i,j+1 2w i,j + w i,j 1 ( x) 2 ( ) ( w i+1,j wi 1,j ( ) x j + w R 2 z Ri i,j i ( )] } + 1 w i,j+1 wi,j 1 + B( + 1) x j 2 x + xj Ri ( ) R u i,j i Ri ) ( w i,j+1 w i,j 1 We solve equation (2) for value of w by using boundary conditions (11)-(15). After obtaining axial velocity, radial velocity can be obtained using equation (19). For numerical calculations following data is used. This data have been made use of Mandal et al [1] d = 6 mm, l = 7.5 mm, L = 3 mm, a =.8 mm, ρ = 1.6 1 3 g/m 3, µ =.35 P, τ m =.2a, A = 1 Kg m 2 s 2, A 1 =.2A, K R =.5, r = 1 mm/s 2. 2 x ) (2) 6. Results Using the parameters shown above, the shape function R (z, t) is plotted over the length of the artery z for different values of time taen into consideration. Figure 2 shows distribution of time dependent stenosis over the length of the artery for different time periods. The stenosis is sinusoidal which has single pea where height of stenosis is maximum. Also the curves follow the shape of the stenosis over the length of artery and remain constant before and after the stenosis region. The figure 3 shows radial variation of axial velocity in the presence of body accelerations for different times. As time increases the axial velocity increases. In figure 4 curves are plotted by removing body acceleration term. In the absence of body acceleration the axial velocity is lower as compare to its value in the presence of body accelerations. Figure 5 shows radial variation of radial velocity for different times at z = 2 mm from the inlet of artery. It is observed that all the curves of radial velocity decrease from zero on the axis as one moves away from the axis and finally increase towards the wall to attend some finite value on the wall which is due to the presence of wall motion. Also, it is clear from the graph that as time increases, the radial velocity also increases in the same pattern. 4

Neeta D.Kanane and N.S.Bode Figure 2: Shape function for varying time Figure 3: Radial variation of axial velocity for different times with body acceleration and = Figure 4: Radial variation of axial velocity for different times without body acceleration 41

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations Figure 5: Radial variation of radial velocity for different times (z = 2mm) 7. Conclusion The axial velocity of the blood increases as time increases. It decreases from its maximum to zero. On the axis of symmetry it is maximum and becomes zero at the wall of the artery due to no slip condition. There is impact of body acceleration on blood velocities. Whenever human body is subjected to body accelerations axial velocity increases in comparison with the body without body accelerations.also the blood flow follows the shape of the stenosis. References [1] P.K.Mandal, S.Charavarty, A.Mandal and N.Amin, Effect of body acceleration on unsteady pulsatile flow of nonnewtonian fluid through a stenosed artery, Applied Mathematics and computation, 189(27), 766-779. [2] S.Charavarty and A.Sannigrahi, A nonlinear Mathematical model of blood flow in a constricted artery experiencing body acceleration, Mathematical and Computer Modelling, 29(1999), 9-25. [3] J.C.Mishra and B.Pal, A mathematical modelling for the study of the pulsatile flow of blood under externally imposed body acceleration, Mathematical and Computer Modelling, 29(1)(1999), 89-16. [4] N.Mustapha, P.K.Mandal, P.Johnston and N.Amin, A numerical simulation of unsteady blood flow through multiirregular arterial stenoses, Applied Mathematical modelling, 34(21), 1559-1573. [5] S.Charavarty and P.K.Mandal, Two-dimensional blood flow through tapered arteries under stenotic conditions, International journal of non-linear mechanics, 35(2), 779-793. [6] A.C.Burton, Physiology and Biophysics of the circulation, Year boo medical publisher, Chicago, (1966). [7] D.S.Sanar and Usi Lee, Nonlinear mathematical analysis for blood flow in a constricted artery under periodic body acceleration, Communication and nonlinear Science and numerical simulation, 16(211), 439-442 [8] D.F.Young, Effect of time dependent stenosis on flow through a tube, Journal of Engineering for Industry, 9(1968), 248-254. [9] Sarifuddin, S.Charavarty and P.K.Mandal, Effect of heat and mass transfer on non-newtonian flow-lins to atherosclerosis, International Journal of Heat and Mass Transfer, 52(29), 5719-573. [1] T.J.Pedley, The fluid mechanics of large blood vessels, Cambridge University Press, London, (198). 42

Neeta D.Kanane and N.S.Bode [11] J.N.Mazumdar, Bio fluid mechanics, World Scientific Publisher, (24). [12] Won Young Yang and John Morris, Numerical methods using MATLAB, John Wiley Publication, (25). [13] B.Carnahan, Applied numerical methods, Krieger Publication, (199). 43