Similar documents
Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Calculation of the heat power consumption in the heat exchanger using artificial neural network

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Heat and Mass Transfer Prof. S.P. Sukhatme Department of Mechanical Engineering Indian Institute of Technology, Bombay

Chapter 3 NATURAL CONVECTION

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

Heat processes. Heat exchange

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

PHYSICAL MECHANISM OF NATURAL CONVECTION

INSTRUCTOR: PM DR MAZLAN ABDUL WAHID

vector H. If O is the point about which moments are desired, the angular moment about O is given:

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

A dynamic model of a vertical direct expansion ground heat exchanger

Principles of Convection

Ceiling mounted radiant panels calculations of heat output in heating and cooling application

Overall Heat Transfer Coefficient

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

Reflow Soldering Processes Development Using Infrared Thermography

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

HEAT TRANSFER. Mechanisms of Heat Transfer: (1) Conduction

Use of Matlab package for external local calibration of IR camera with microbolometric FPA detector

If there is convective heat transfer from outer surface to fluid maintained at T W.

1 One-dimensional analysis

Introduction to Heat and Mass Transfer. Week 14

QIRT th International Conference on Quantitative InfraRed Thermography

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

Transactions on Engineering Sciences vol 18, 1998 WIT Press, ISSN

HEAT TRANSFER AND FLOW CHARACTERISTICS OF OFFSET FIN AND FLAT TUBE HEAT EXCHANGERS UNDER LOW PRESSURE ENVIRONMENT

10 minutes reading time is allowed for this paper.

Outlines. simple relations of fluid dynamics Boundary layer analysis. Important for basic understanding of convection heat transfer

Fluid flow consideration in fin-tube heat exchanger optimization

Real Temperature Distribution on the Surface of Underfloor Heating

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

MECHANISM BEHIND FREE /NATURAL CONVECTION

Chapter 7: External Forced Convection. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Advances in Fluid Mechanics and Heat & Mass Transfer

S.E. (Chemical) (Second Semester) EXAMINATION, 2012 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

MAE 598 Project #1 Jeremiah Dwight

Vertical Mantle Heat Exchangers for Solar Water Heaters

A numerical study of heat transfer and fluid flow over an in-line tube bank

Determination of heat losses of a concrete silo for sugar and a fan project

UNIT II CONVECTION HEAT TRANSFER

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Solar Flat Plate Thermal Collector

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

1 st Law Analysis of Control Volume (open system) Chapter 6

Mechanical Engineering. Postal Correspondence Course HEAT TRANSFER. GATE, IES & PSUs

Div. 1 Div. 2 Div. 3 Div.4 8:30 am 9:30 pm 12:30 pm 3:30 pm Han Xu Ruan Pan

Level 7 Post Graduate Diploma in Engineering Heat and mass transfer

Numerical calculations of the thermal deformations of the rectangular minichannel walls

Convection Heat Transfer. Introduction

Analyzing Mass and Heat Transfer Equipment

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Performance Tests for an All-welded Plate Heat Exchanger Liang Huang1,a, Bingcheng Liu1,b and Qingling Li1,c

CORRUGATED CHANNELS HEAT TRANSFER EFFICIENCY ANALYSIS BASED ON VELOCITY FIELDS RESULTING FROM COMPUTER SIMULATION AND PIV MEASUREMENTS

Heat Transfer of Condensation in Smooth Round Tube from Superheated Vapor

Examination Heat Transfer

ESRL Module 8. Heat Transfer - Heat Recovery Steam Generator Numerical Analysis

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Technological design and off-design behavior of heat exchangers 26

Fall 2014 Qualifying Exam Thermodynamics Closed Book

Investigations of hot water temperature changes at the pipe outflow

Performance evaluation of heat transfer enhancement for internal flow based on exergy analysis. S.A. Abdel-Moneim and R.K. Ali*

Experiment (4): Flow measurement

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Performance Analyses of a Multiple Horizontal Tubes for Steam Condensation

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Infrared measurements of heat transfer in jet impingement on concave wall applied to anti-icing

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

FORMULA SHEET. General formulas:

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

Introduction to Heat and Mass Transfer. Week 5

HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR

Chapter Four fluid flow mass, energy, Bernoulli and momentum

Chapter 5. Mass and Energy Analysis of Control Volumes

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

Forced Convection Heat Transfer Augmentation from Ribbed Surface

Measurements of temperature of brake disks in hoisting machines of mine shaft hoists

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

INTRODUCTION: Shell and tube heat exchangers are one of the most common equipment found in all plants. How it works?

Optimization of Shell And -Tube Intercooler in Multistage Compressor System Using CFD Analysis

Ministry of Higher Education And Scientific Research. University Of Technology Chemical Engineering Department. Heat Transfer

S.E. (Chemical) (Second Semester) EXAMINATION, 2011 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

Angular momentum equation

C ONTENTS CHAPTER TWO HEAT CONDUCTION EQUATION 61 CHAPTER ONE BASICS OF HEAT TRANSFER 1 CHAPTER THREE STEADY HEAT CONDUCTION 127

Investigation of the Effect of a Synthetic Jet on the Heat Transfer Coefficient

: HEAT TRANSFER & EVAPORATION COURSE CODE : 4072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 70 CREDIT : 5 TIME SCHEDULE

Investigation of Jet Impingement on Flat Plate Using Triangular and Trapezoid Vortex Generators

Transcription:

9 th International Conference on Quantitative InfraRed Thermography July 2-5, 2008, Krakow - Poland Application of infrared thermography for validation of numerical analyses results of a finned cross-flow heat exchanger with non uniform flow of the agents *Institute of Thermal Technology, Silesian University of Technology, Gliwice, Poland Abstract by T. Bury* and T. Kruczek* The general aim of the work was determination of the influence of disturbances in velocity field of inlet air on the operation efficiency of heat exchanger under consideration. The inlet air velocity and temperature distributions, as well as the other characteristic parameters, were measured on a specially designed laboratory stand. The experimental results were then used as the input data in own computer code named HEWES. The outcomes of this calculations were compared with heat transfer estimated on the basis of measurements. An additional validation of the numerical results was performed by means of the infrared thermography measurements. 1. Introduction The thermodynamic analysis of a ribbed cross-flow heat exchanger of the liquid-gas type for an example of a typical car radiator is the subject of the research. The heat transfer coefficients at the liquid and the gas side and the area of the heat transfer are the main parameters describing such a heat exchanger. Determination of the heat transfer coefficient at the liquid side does not make up a larger problem. The turbulent flow inside the pipes is a thoroughly examined case and the most of the existing empirical correlations give a comparable results [1]. The basic problem in computations of such a type of heat exchangers there is to calculate the heat transfer coefficient from the ribbed surfaces to a gas. Formulation of an universal correlation for the Nusselt number is not possible due to the diversity of constructions. The selection of the proper relationship for the specified geometry is also difficult, as well as the selection of the characteristic dimension. The diversity of the local values of the heat transfer coefficient resulting from the unequal flows of the agents through the exchanger additionally complicates the analysis [2]. The measurements were accomplished on the test station for research of the cross-flow heat exchangers at the Institute of Thermal Technology of the Silesian University of Technology to determine the form of the unequal air flux distribution at the inlet cross section of the considered radiator. Using the measurements results as the input data the heat transfer coefficient was numerically calculated. The final effect of these analyses is a computer code, called HEWES, for thermal analyses of the considered type of heat exchangers [3]. The initial arrangement of the test station has not allowed for validation of the code. The test station was modernized in the frameworks of the current research project and the validation procedure became possible. The total heat flux transported in the heat exchanger is the main comparing parameter, but the average heat transfer coefficient, air and water outlet temperature may be also compared. It was also assumed that the infrared thermography measurements of the outlet cross section temperature field may be useful for an additional validation of the HEWES code. 2. Numerical model of the heat exchanger The mathematical model of the considered heat exchanger was worked out taking into account the following simplifying assumptions: steady state conditions, one-dimensional agents flow, no internal heat sources, radiation is neglected, heat losses are neglected, heat flow is normal to a boundary, real rib is replaced with a round or a plate-elliptic rib of the same surface. It was also assumed that the air inflow is non-uniform and the water inflow may be non-uniform. An influence of temperature on thermal properties of the agents was taken into account too. The analysed real cross-flow heat exchanger was replaced with a model rectangular heat exchanger. The model was then divided onto elementary fragments (see figure 1). Each fragment represents a recurrent element of the real heat exchanger - a single tube with the rib [3].

9 th International Conference on Quantitative InfraRed Thermography z dy dx dz y x Fig. 1. Model heat exchanger and the recurrent fragment The energy balance equations for each fragment constitute the mathematical basis of the model. Assuming that the water flows along the X axis and the air flows along the Y axis the energy balance for a recurrent fragment may be written as follow: Tw Ta dq = m& wcpw dx = m& ac pa dy = αa ( Tm Ta )da x y & (1) where α a is an average heat transfer coefficient at the gas side for all the ribbed surface and T m is the average temperature of rib and pipe surface. The control volume method based model of heat transfer for the recurrent fragment of the heat exchanger was worked out to calculate the average temperature of the ribs and tube outer surface. The detailed description of the model and equations can be found in [3]. The parameters calculated with the model of the recurrent fragment are: outlet and average temperature of the water flowing in the pipe, average temperature of the air, average temperature of the rib and the pipe surface, average values of the heat transfer coefficients at the gas side and the heat flux transported in the recurrent fragment. The heat transfer coefficient from the hot water to the pipe is computed from Colburn's formula [1]. The heat transfer coefficient at the gas side may be determined on the way of the numerical simulations for a numerical model of the recurrent fragment of the considered heat exchanger [4] or may be computed from one of available Nusselt number correlations. The calculation procedure for the whole exchanger model is iterative and it is repeated for all the recurrent fragments of the considered heat exchanger. First, the air temperature increase in the analysed fragment is assumed. Next, the heat transfer coefficients for the water and the gas sides are calculated as well as the rib and pipe surface average temperature. The heat flux transported in the recurrent fragment is then computed and the accuracy criterion is checked. If the criterion is satisfied the procedure is realized for the next fragment. If the criterion is not fulfilled the described procedure is then repeated for the given recurrent fragment till the demand accuracy is achieved. 3. Analyses of experiments and numerical simulations 3.1. The laboratory stand Fig. 2. The diagram of the laboratory stand air supply module - (1 - support plate, 2 - considered heat exchanger, 3 - thermo-anemometric sensor, 4 - measuring probe, 5 - diffuser, 6 air channel, 7 - control computer, 8 - fan)

FLUID DYNAMICS The simplified scheme of the laboratory experimental stand is shown in figures 2 and 3. The temperature and velocity of cooling air at selected nodes of measuring net were continuously measured during the experiments. These parameters were measured by means of a thermo-anemometric sensor. The shifting of the sensor was controlled by a computer and the measuring results were recorded by computer as well. Additionally other parameters were measured as inlet and outlet water temperature, flow rate of water and total flow rate of air. 1 2 3 4 5 8 7 o C 6 Fig. 3. The diagram of the laboratory stand water supply module (1 electric heater, 2 cut-out valve, 3 manometer, 4 control valve, 5 heat exchanger, 6 water temperature measuring system, 7 flow meter, 8 pump) Three parameters are assumed as independent and may be set by a researcher: the air and water streams and the inlet water temperature. 3.2. Measurement procedure and results The measuring task must be defined before an experiment is started. The task information contains a thermo-anemometric sensor characteristic and the measuring net definition (coordinates of the measuring knots). The measurements were started after the steady state condition was achieved. The air velocity and its temperature distribution at the inlet to the exchanger are ones of the most important experimental results. These information are used for computations of the heat transfer coefficient and for determination of the inequality factors. The distribution of the air velocity at the inlet cross-section of the cooler for one of the measuring series is presented in figure 4. An exemplary temperature distribution at the exchanger outlet is shown in figure 5. The temperature distribution information is used for calculations of the average inlet and outlet temperatures. 200 150 100 50 0 0 50 100 150 200 250 300 350 400 13 12.5 12 11.5 11 10.5 10 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 3 Fig. 4. Distribution of the velocity of the air at the inlet cross section of the car cooler for experiment T2, m/s 200 150 100 50 0 0 50 100 150 200 250 300 350 400 Fig. 5. Distribution of the temperature of the air at the outlet cross section of the car cooler for experiment T4, ºC 59 58 57 56 55 54 53 52 51 50 49 48 47 The selected experimental data from these measurements are gathered in table I. Table 1. Selected results of measurements Parameter Experiment T1 T2 T3 T4 Air volumetric flow, m 3 /s 0,78 1,25 0,78 1,25 Water volumetric flow, m 3 /s 4,5 10-4 4,5 10-4 4,5 10-4 4,5 10-4 Air inlet temperature, ºC 33,01 34,12 30,65 34,51 Air outlet temperature, ºC 47,04 43,60 57,04 51,34

9 th International Conference on Quantitative InfraRed Thermography 3.3. Code validation Water inlet temperature, ºC 58,4 59,1 78,7 78,6 Water outlet temperature, ºC 50,9 50,3 65,1 63,2 The validation of the model has been performed by means of the comparison of the experimental results with outcomes of the code. Four parameters have been compared: total heat flux transported in the exchanger, average heat transfer coefficient, average water temperature, average air temperature. Exp. Num. Table 2. Selected results of comparative analysis T1 T2 T3 T4 total heat flux, kw 13,6 16,0 24,7 28,0 average air temperature, ºC 40,2 38,3 45,0 42,2 average water temperature ºC 54,7 54,7 71,9 70,9 heat transfer coefficient, W/(m K) 62,9 65,9 62,1 65,8 total heat flux, kw 8,1 9,7 15,2 17,8 average air temperature, ºC 39,0 37,3 44,4 40,8 average water temperature ºC 56,2 56,3 74,6 73,4 heat transfer coefficient, W/(m K) 39,8 40,5 43,3 43,8 Selected results of the comparative analysis are shown in table 2. It can be observed that numerical values of the total heat flux are much smaller than the experimental ones. The way of the heat transfer coefficient determination has been indicated as the reason of these discrepancies. The results of performed initial sensitivity analysis show that the heat transfer coefficient may be not only one reason of the differences [5]. Relatively large change of the heat transfer coefficient values caused visible but not significant change of the total heat flux. A further works in this field are in progress at the moment. The infrared thermography was decided to be used for extending of the range of the validation procedure. The aim of these measurements was to get data for comparison of numerically determined distribution of temperature at the outlet of the exchanger. 4. Infrared thermography measurements The thermographic measurements have been done using ThermaCAM SC2000 camera. First measurements have been done with perpendicular arrangement of the camera in respect to the investigated surface, and they shown almost even distribution field of the temperature (see figure 6). 494 Case P1-1 Case P1-2 200 285 200 130 130 210 195 Case P2-2 130 Case P3-1 494 Fig. 6. Distribution of temperature at the outlet of the heat exchanger exemplary results with the perpendicular arrangement of the camera in respect to the investigated surface Fig. 7. The diaphragms localization and sizes for a selected cases Because the results shown above can not be interpreted unambiguously they were not used for validation. The further infrared thermography measurements have been done with using different arrangements of the camera. The best results were obtained using sharp angle arrangements. The most measurements have been also realized with additional disturbance inserted in front of the exchanger in form of a diaphragm. The basic aim

FLUID DYNAMICS of this measurements was determination of the influence of disturbances in velocity field of inlet air on the operation efficiency of heat exchanger under consideration. A cardboard diaphragms were used to block the air inflow to the heat exchanger in a part of the inlet crosssection. Diagrams showing a selected diaphragms localization and sizes are shown in figure 7. The diaphragms used during measurements allowed to cover from 18,5 up to 46% of the total inlet cross-section area. A reference cases were investigated before the air inflow was choked. These measurements were the basis for evaluation of the influence of the air flow disturbances on the heat exchanger operation efficiency. The results of analysis are gathered in table 3. The total heat flux was calculated based on the water enthalpy drop. The same cases were also simulated by the HEWES code. The authors, remembering the significant differences described earlier, wanted to check if the code is able to predict the heat exchanger efficiency drop. Table 3. Selected results of comparative analysis Case Experiment HEWES Reference Relative Relative value of the Heat flux, W heat flux Heat flux, W heat flux heat flux, W drop, % drop, % P1-1 12079,2 10871,3 10,0 8377,4 13,5 P1-2 12079,2 10146,5 16,0 7651,1 21,0 P2-2 12079,2 9904,9 18,0 7215,3 25,5 P3-1 37580,2 28568,6 24,0 20146,6 32,3 It may be noticed that the differences between the total heat flux obtained from experiments and computations are still significant. The HEWES code also overestimated the relative heat flux drop for the considered cases. The infrared thermography measurements were realized during investigations of the considered cases. Results of these measurements were then compared with numerically determined temperature field at the heat exchanger outlet cross-section. First the reference cases were analysed. The exemplary results for such case are presented in figures 8 and 9. To make the infrared camera images more useful for comparison the original temperature scale was changed. One may observe in fig. 8 that there are at least two pipes where the water flow is very small. This effect is invisible in the numerical results of course, because a uniform water flow through all the pipes was assumed see figure 9. Analysing temperature fields shown in figures 8 and 9 it can be observed than the numerically predicted temperature values are a little bit lower than the experimental ones. The differences reach up to 5 K and are a relatively large. It is very probable that the method of determination of the pipes wall and rib surface average temperature may be another reason for the differences revealed during validation. Moreover, the qualitative discrepancies are also visible the isotherms shape is quite different. The selected results for the cases with the diaphragms are shown in figures 10 to 12. The diaphragms localizations are clearly visible on thermographic pictures. It may be noted that in the area covered by these diaphragms there are almost no water temperature drop considering the experimental results. Only one numerically obtained temperature field is presented here due to limited space. Analysing results shown in figure 11 one may note that the border of the area covered by the diaphragm is not as sharp as in the thermographic picture (see figure 10). Despite of this the conformity of the experimental and numerical results for this case is even better than for the reference case presented earlier. 43 42 41 40 39 38 37 36 35 34 33 32 Fig. 8. The temperature field at the heat exchanger outlet cross-section reference case, infrared measurement Fig. 9. The temperature field at the heat exchanger outlet cross-section reference case, HEWES

9 th International Conference on Quantitative InfraRed Thermography 44 43 42 41 40 39 38 37 36 35 34 33 32 31 Fig. 10. The temperature field at the heat exchanger outlet cross-section case P1-1, infrared measurement Fig. 11. The temperature field at the heat exchanger outlet cross-section case P1-1, HEWES Fig. 12. The temperature field at the heat exchanger outlet cross-section case P3-1, infrared measurement A blocking of the air inflow to the heat exchanger causes the drop of the total heat flux of course and affects the exchanger thermal efficiency. But in some types of car coolers this method is used for regulation of the water outlet temperature, especially in winter conditions a special blinds are applied and the exchanger outlet temperature field may look as presented in figure 12. 5. Final remarks and conclusions The results of the validation procedure presented here are an effect of the initial analysis which is aimed to evaluate the HEWES code. These results show a significant discrepancies between experimental and numerical outcomes. The validation of the HEWES code is in progress. The measuring errors influence should be investigated and also the radiation heat transfer seems to be considered too. A special experiments are planned to be introduced into the validation procedure. Application of the infrared thermography technique allowed to widespread the range of the HEWES code validation and it will be continuously used in further investigations. These measurements shown also very small flow of water in at least two pipes. This problem is probably caused by blocking of the pipes and should be fixed before continuation of the experiments. Furthermore, the pipes choking may affect the water velocity field and may be a reason of the differences between experimental and numerical results as well. The temperature field in the heat exchanger elements identified by means of the infrared thermography may be also used for evaluation of thermal stress. The general aim of this work was to evaluate the influence of a disturbance in the air inflow on the heat exchanger operation efficiency, so it should be stated here that blocking of the air flow by the exchanger can seriously decrease the total heat flux transported between the agents. Similar results were obtained by means of numerical simulations. Acknowledgement This work has been realized in the frameworks of the project No. 3T10B06229 financed by the Ministry of Science and Information Technology (at the moment Ministry of Science and Higher Education).

FLUID DYNAMICS REFERENCES [1] Kostowski E. Heat Transfer. The Silesian University of Technology Publishing Office, Gliwice 2000. (in Polish) [2] Saboya F.E.M., Sparrow E.M. Local and Average Transfer Coefficients for One-Row Plate Fin and Tube Heat Exchanger Configurations. ASME Journal of Heat Transfer, 96 (1974) 265-272. [3] Piątek R. Thermal Analysis of Plate Fin and Tube Heat Exchanger with Unequal Inlet of Mediums. PhD Thesis, Institute of Thermal Technology, Sielsian University of Technology, Gliwice 2003. (in Polish) [4] Bury T., Składzień J. The Experimental and the Numerical Analysis of a Ribbed Heat Exchanger With an Unequal Inlet of the Air. In Proceedings of Heat Transfer and Renewable Sources of Energy 2006, Międzyzdroje, Poland, September 13-16, 2006, 419-426. [5] Bury T., Piątek R., Składzień J. Experimental validation of the numerical thermal model of the cross-flow heat exchanger with unequal agent flow. ECOS 2008, to be published.