UCT SELECTRA AQUEOUS C18 HPLC COLUMNS

Similar documents
SELECTRA PFPP UCT PENTAFLUOROPHENYLPROPYL STATIONARY PHASE HPLC COLUMNS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

UCT ENVIRO-CLEAN HL DVB

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

for Acclaim Mixed-Mode HILIC-1 Column

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

A Simple SPE Method for the Determination of Malachite Green, Crystal Violet and Other Synthetic Dyes in Seafood

Determination of urea in ultrapure water by IC-MS/MS

FAQ's. 1 - Which column would be the most appropriate for my application?

Analysis of Tobacco Alkaloids


Determination of Phenoxyacid Herbicides in Water by Solid Phase Extraction and LC-MS/MS Detection

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

High Performance Liquid Chromatography

ProPac WCX-10 Columns

LC Technical Information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

High Performance Liquid Chromatography

High Performance Liquid Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

[ CARE AND USE MANUAL ]

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WCX-1

Potential sources of contamination on Mass Spectrometers and suggested cleaning procedures

Shodex TM ODP2 HP series columns

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

C18 Column. Care & Use Sheet

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

8. Methods in Developing Mobile Phase Condition for C18 Column

Alltech Alltima HP Introduction

ACQUITY UPLC HSS Columns

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Determination of trace anions in concentrated hydrofluoric acid

penta-hilic UHPLC COLUMNS

for Acclaim Mixed-Mode WCX-1

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

High Performance Liquid Chromatography

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

EPA Method 1694: Analysis of Pharmaceuticals and Personal Care Products in Water

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

1.7 m Fortis UHPLC Columns

AMP + MaxSpec Kit. Item No Customer Service Technical Support

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

ION CHROMATOGRAPHY SYSTEM S 150

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Chapter content. Reference

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

LC and LC/MS Column Selection Flow Chart

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Dionex IonPac AS28-Fast-4µm column

Analyst Software. Automatic Optimization Tutorial

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

COLUMN GUIDE - Usage and maintenance of HPLC columns

HPLC Praktikum Skript

[ Care and Use Manual ]

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Guide to Choosing and Using Polymer Reversed Phase Columns!

Successfully Scaling and Transferring HPLC and UPLC Methods

for Acclaim Trinity TM P1

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Dilution(*) Chromatography

Basic principles of HPLC

ikey Separation Device

Luminescence transitions. Fluorescence spectroscopy

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Open Column Chromatography, GC, TLC, and HPLC

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Transcription:

UCT SELECTRA AQUEOUS C18 HPLC COLUMNS I N N O VAT I O N T H R O U G H C H E M I S T R Y

SELECTRA AQUEOUS C18 HPLC COLUMNS Product Benefits Similar non-polar retention to traditional C18 Some selectivity differences for polar analytes Suitable in up to % aqueous mobile phases Greater range of mobile phase options Carbon Load % Conforms to USP L1 Selectra Aqueous C18 HPLC Columns Dimensions Particle Size Part Numbers x 2.1 mm 1.8 µm SLAQID21-18UM x 2.1 mm 1.8 µm SLAQID21-18UM x 4.6 mm 1.8 µm SLAQID46-18UM x 4.6 mm 1.8 µm SLAQID46-18UM x 2. mm guard (sold as a 2 pack) 1.8 µm SLAQGDC-18UM x 2.1 mm 3 µm SLAQID21-3UM x 2.1 mm 3 µm SLAQID21-3UM x 4.6 mm 3 µm SLAQID46-3UM x 4.6 mm 3 µm SLAQID46-3UM 1 x 4.6 mm 3 µm SLAQ1ID46-3UM x 2. mm guard (sold as a 2 pack) 3 µm SLAQGDC-3UM x 2.1 mm 5 µm SLAQID21-5UM x 2.1 mm 5 µm SLAQID21-5UM x 4.6 mm 5 µm SLAQID46-5UM x 4.6 mm 5 µm SLAQID46-5UM 1 x 4.6 mm 5 µm SLAQ1ID46-5UM 2 x 4.6 mm 5 µm SLAQ2ID46-5UM x 2. mm guard (sold as a 2 pack) 5 µm SLAQGDC-5UM HPLC Guard Holder HPLC Guard Cartridge Holder SLGRDHLDR Replacement Peek Tip for Holder SLGRDHLDR-TIP (2/pk) 215.781.9255.385.3153

Because of the hydrophobic nature of C18 stationary phases, it is difficult to retain polar compounds on the surface. Typically, in an effort to gain added retention and move polar compounds away from the void volume, the initial percent organic is reduced. As the percent aqueous increases to account for this, C18 phases can undergo phase collapse or more properly dewetting. Dewetting occurs when column flow is stopped, which minimizes the pressure needed to force water into the hydrophobic pores of the substrate. The water is then evacuated from the pores and regardless of a flow restart, will not re-enter. Since most of the surface area for analyte interaction is located within the pore structure, this phenomenon causes significant lose in retention. UCT has created a unique C18 ligand and bonding procedure that creates a true C18 phase that is also compatible with up to % aqueous mobile phases. Even after flow is stopped and restarted, no significant loss in retention is observed. Additionally, many polar analytes exhibit enhanced retention and selectivity using the Selectra Aqueous C18 column. Traditional C18 column SELECTRA AQUEOUS C18 column R e la tive Abund a nce RT:. - 14. SM: 7G 17-alpha-methyltestosterone; Methenolone; Norethandrolone.18.63 NL: 2.E6 3. [76.999-77.1, 82.999-83.1, 96.999-97.1, 8.999-9.1, 187.99-187.1, 267.199-267.1] MS ppb 4 R e l a tiv e A b u n d a n c e RT:. - 14. SM: 7G 17-alpha-methyltestosterone; Methenolone; Norethandrolone.91 11.46 12.75 NL: 5.E5 3. [76.999-77.1, 82.999-83.1, 96.999-97.1, 8.999-9.1, 187.99-187.1, 267.199-267.1] MS ppb_aqc18_final3.62 1.7 1.49 2.29 2.76 3.26 3.73 4.11 4. 5. 5. 5.97 6.43 6.91 7.38 7. 8.22 8.58 8.96 9.59 11.69 12.39 12.89 13.35 8.92 9.39 9.95 13.75 21-Deoxycortisol; 8.85 NL: 9.78E5 347. [4.999-5.1, 127.999-128.1] MS ppb 4 4.86 5.35 21-Deoxycortisol; NL: 6.24E4 347. [4.999-5.1, 127.999-128.1] MS ppb_aqc18_final3 R e la tive A b undance Corticosterone; 11- Deoxycortisol 8.26 e a v e R ul n ti a n Ac eb 5.61 Corticosterone; 11- Deoxycortisol 11.8 9.72.24.66 1.4 1.42 1.79 2.24 2.75 3. 3.84 4.28 4.73 5.46 6.2 6.47 6.87 7.34 7.72.31 11.56 12.2 12.52 13.8 13.63 1 2 3 4 5 6 7 8 9 11 12 13 14 2.36 2.81 3. 3.61 4.2 4.42 6.46 6.91 7.28 7.64 1 2 3 4 5 6 7 8 9 11 12 13 14 Only capable of resolving 2 of the 3 steroids Capable of resolving all 3 steroids www.unitedchem.com

SELECTRA AQUEOUS C18 HPLC COLUMNS Organophosphate Pesticides in Urine RT:. - 16.98 SM: 7G 3.53 Relative Abundance 2.45 2.54 3.53 4.65 5. 4.36 4.54 5.27 5.88 6.78 7.77 6. 4.15 5.44 7.4 6.19 4.69 Methamidophos Acephate Dicrotophos o,o,o-triethylphosphorothioate Dimethoate 6.96 7.93 8.76 7.71 Famphur 9.58.67.23 8.55 11.29 Malathion 2 4 6 8 12 14 16 NL: 1.64E5 142. [93.729-93.731, 124.629-124.631] MS ppb_f3 NL: 7.14E4 183.913 [94.639-94.641, 142.619-142.621] MS ppb_f3 NL: 1.53E5 237.2 [71.729-71.731, 126.629-126.631] MS ppb_f3 NL: 1.8E5 198.988 [78.639-78.641, 124.599-124.1] MS ppb_f3 NL: 7.86E5 229.979 [124.589-124.591, 1.559-1.561] MS ppb_f3 NL: 7.19E5 325.943 [92.629-92.631, 216.579-216.581] MS ppb_f3 NL: 5.7E5 3.942 [98.639-98.641, 126.649-126.651] MS ppb_f3 RT:. - 16.98 SM: 7G Sulfotep.67 Diazinon 12.8 TPP (IS) Pyrazophos 13.46 12.82 11.89 13.94 13.14 12.5 14.44 13.42 11.62 Profenofos Ethion 14.55 14.6 13.22 15. 14.33 13.2 Chlorpyrifos 13.15 15.27 14.54 2 4 6 8 12 14 16 16.17 NL: 2.85E5 322.947 [96.549-96.551, 114.539-114.541] MS ppb_f3 NL: 3.35E5 4.979 [152.9-152.711, 168.659-168.661] MS ppb_f3 NL: 6.84E5 326.961 [76.659-76.661, 151.629-151.631] MS ppb_f3 NL: 1.61E6 373.9 [193.619-193.621, 221.639-221.641] MS ppb_f3 NL: 6.67E4 372.942 [127.569-127.571, 4.419-4.421] MS ppb_f3 NL: 3.55E5 384.7 [96.529-96.531, 142.499-142.1] MS ppb_f3 NL: 1.25E4 3.1 [96.569-96.571, 199.329-199.331] MS ppb_f3 HPLC Conditions Instrument: Thermo Scientific Dionex UltiMate LC System Column: UCT, Selectra Aqueous C18, x 2.1 mm, 3 µm Guard column: UCT, Selectra Aqueous C18, x 2. mm, 3 µm Column temperature: C Column flow rate:. ml/min Auto-sampler temperature: C Injection volume: µl Mobile Phase A: mm ammonium formate in water Mobile Phase B:.1% formic acid in MeOH Gradient: Time %A %B MS Parameters Detector: Thermo Scientific TSQ Vantage tandem MS Polarity: ESI + Spray voltage: V Vaporizer temperature: 378 C Ion transfer capillary temperature: C Sheath gas pressure: arbitrary units Auxiliary gas pressure: 5 arbitrary units Q1 and Q3 peak width (FWHM):.4 and.7 Da Collision gas and pressure: Ar at 1.5 mtorr Cycle time: 1 sec Acquisition method: EZ Method (scheduled SRM).5 3 4.5 6 35 65 9 35 65 13 5 95 15 5 95 15.1 19 Divert mobile phase to waste from - 2 and 16-19 min to prevent ion source contamination. 215.781.9255.385.3153

EPA 538: Selected Organic Contaminants in Drinking Water C:\Xcalibur\...\ 6/3/15 6:49:28 PM RT:. - 13. 3.41 Methamidophos NL: 3.23E4 ms2 141.987 [93.999-94.1, 124.979-124.981] MS RT:. - 13. DIMP 9.66 NL: 2.73E5 ms2 181.71 [79.9-79.11, 97.9-97.11] MS 3.74 4.29 5.69 Acephate NL: 2.91E4 ms2 184. [95.9-95.11, 142.989-142.991] MS Fenamiphos sulfone. 9.46.47 9.85 NL: 2.37E5 ms2 336.58 [188.19-188.21, 266.39-266.41] MS Aldicarb sulfoxide 6.4 7.24 NL: 3.97E4 ms2 7.21 [69.89-69.91, 89.49-89.51] MS 8.88 9.22.15 9.92 Fenamiphos sulfoxide NL: 3.E5 ms2 3.54 [8.39-8.41, 232.989-232.991] MS 6.44 7.69 7.83 Oxydemeton-methyl NL: 5.67E5 ms2 247.4 [8.989-8.991, 168.999-169.1] MS Thiofanox H + 9.23.22.9 NL: 4.22E3 ms2 219. [57.9-57.111, 76.29-76.31] MS 7.53 Dicrotophos 8.21 8.34 NL: 5.88E4 ms2 238.57 [112.59-112.61, 126.999-127.1] MS Thiofanox NH 4 +.38 9.79.92 9.47.11 NL: 5.85E3 ms2 236.99 [57.89-57.91, 76.49-76.51] MS Aldicarb 7.84 8.95 9.15 NL: 5.94E4 ms2 8. [89.49-89.51, 116.39-116.41] MS Quinoline.23 9.76.91.18 NL: 5.64E6 ms2 1. [77.59-77.61, 3.69-3.71] MS 1 2 3 4 5 6 7 8 9 11 12 13 8. 9.39.91 11.59 1 2 3 4 5 6 7 8 9 11 12 13 9.89 HPLC Conditions Instrument: Thermo Scientific Dionex UltiMate LC System Column: UCT, Selectra Aqueous C18, x 2.1 mm, 3 µm Guard column: UCT, Selectra Aqueous C18, x 2. mm, 3 µm Column temperature: C Column flow rate:. ml/min Auto-sampler temperature: C Injection volume: µl Mobile Phase A: mm ammonium formate in water Mobile Phase B: MeOH Gradient: Time %A %B MS Parameters Detector: Thermo Scientific TSQ Vantage tandem MS Polarity: ESI + Spray voltage: V Vaporizer temperature: 378 C Ion transfer capillary temperature: C Sheath gas pressure: arbitrary units: Auxiliary gas pressure: 5 arbitrary units: Q1 and Q3 peak width (FWHM):.2 and.7 Da Collision gas and pressure: Ar at 1.5 mtorr Cycle time: 1 sec Acquisition method: EZ Method (scheduled SRM) 2 9 15 85 12 15 85 12.1 16 Divert mobile phase to waste from - 2 and 14-16 min to prevent ion source contamination. www.unitedchem.com

SELECTRA AQUEOUS C18 HPLC COLUMNS Anabolic Steroids RT:. - 16. SM: 7G 3.61 1.13 2. 1.12 2.91 2.66 3.98 Cortisone 5.15 6.32 Cortisol 4.72 5.67 6.68 5.33 4. 6.41 7.61 6.45 4.34 5.68 6.71 4.31 5.34 7.65 6.76 8.21 9.15 4.85 5.89 8.5 7. 4. 5.65 4.82 6.14 21-Deoxycortisol; Corticosterone; 11-Deoxycortisol 7. Fluoxymesterone Trenbolone 2 4 6 8 12 14 16 8.79 9.41 Boldenone 9.41 Androstenedione Nandrolone 8.66 9. NL: 3.95E6 361. [.999-91.1, 162.999-163.1] MS Solv_ NL: 1.29E6 363. [.999-91.1, 144.999-145.1] MS Solv_ NL: 1.8E6 347. [4.999-5.1, 127.999-128.1] MS Solv_ NL: 1.35E6 337. [.999-91.1, 242.99-242.1] MS Solv_ NL: 5.4E6 271. [165.99-165.1, 199.99-199.1] MS Solv_ NL: 4.74E6 287. [1.999-121.1, 135.99-135.1] MS Solv_ NL: 1.E7 287. [97.99-97.1, 8.999-9.1] MS Solv_ NL: 3.91E6 275. [.999-91.1, 9.99-9.1] MS Solv_ RT:. - 16. SM: 7G Methandienone 5.72 6.78 17 -hydroxyprogesterone 8.14 9.41 8.32. 6. 9.52.73 8.78 Testosterone; Epitestosterone 16β-Hydroxystanozolol 9. 7.11 11.4 9.42 6.58 7.64 5β-Estran-3alpha-ol-17-one; 5α-Estran-3alpha-ol-17-one 17α-Methyltestosterone; Methenolone; Norethandrolone.14.96 11.69 8.19 13.11.89 12.75 9.37 Progesterone. Stanozolol 11.85 13.73 12.85 12.43 13.42 14.96 14.82 2 4 6 8 12 14 16 NL: 5.54E6 1. [1.999-121.1, 149.99-149.1] MS Solv_ NL: 3.86E6 331. [96.999-97.1, 8.999-9.1] MS Solv_ NL: 1.85E7 289. [96.999-97.1, 8.999-9.1] MS Solv_ NL: 6.24E6 345. [.999-81.1, 94.999-95.1] MS Solv_ NL: 4.91E5 277. [91.99-91.1, 185.99-185.1, 241.199-241.1, 241.199-241.1] MS Solv_ NL: 5.61E6 3. [96.999-97.1, 267.199-267.1] MS Solv_ NL: 1.33E7 315. [96.999-97.1, 8.999-9.1] MS Solv_ NL: 1.13E7 329. [.999-81.1, 94.999-95.1] MS Solv_ HPLC Conditions Instrument: Thermo Scientific Dionex UltiMate LC System Column: UCT, Selectra, AqueousC18, x 2.1 mm, 3 µm Guard column: UCT, Selectra, Aqueous C18, x 2. mm, 3 µm Column temperature: C Column flow rate:. ml/min Auto-sampler temperature: C Injection volume: µl Mobile Phase A: mm ammonium formate in water Mobile Phase B:.1% formic acid in MeOH Gradient: Time %A %B 2 9 12 15 15.1 19 Divert mobile phase to waste from - 3 and 15-19 min to prevent ion source contamination. MS Parameters Detector: Thermo Scientific TSQ Vantage tandem MS Polarity: ESI + Spray voltage: V Vaporizer temperature: 9 C Ion transfer capillary temperature: 249 C Sheath gas pressure: arbitrary units Auxiliary gas pressure: arbitrary units Q1 and Q3 peak width (FWHM):.4 and.7 Da Collision gas and pressure: Ar at 1.5 mtorr Cycle time: 1 sec Acquisition method: EZ Method (scheduled SRM) 215.781.9255.385.3153

GHB 4.5e5 4.e5 GHB 3.5e5 3.e5 Intensity, cps 2.5e5 2.e5 GHB D6 1.5e5 1.e5 5.e4..4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 3.8 4. 4.2 4.4 4.6 4.8 5. Time, min HPLC Conditions Instrument: Agilent Binary Pump SL Column: UCT, Selectra, Aqueous C18, x 2.1 mm, 3 µm Guard column: UCT, Selectra, Aqueous C18, x 2. mm, 3 µm Column temperature: C Column flow rate:. ml/min Auto-sampler temperature: C Injection volume: µl Mobile Phase A:.1% formic acid in H 2 O Mobile Phase B:.1% formic acid in MeOH Gradient: Time %A %B 1.5 2. 3. 3.2 7. Divert mobile phase to waste from - 1 and 3-7 min to prevent ion source contamination. MS Parameters Detector: AB Sciex API QTrap MS/MS Polarity: ESI (-) Spray voltage: 4 V Vaporizer temperature: 6 C Ion transfer capillary temperature: 2 C Sheath gas pressure: arbitrary units Auxiliary gas pressure: arbitrary units Q1 and Q3 peak width (FWHM):.4 and.7 Da Collision gas and pressure: Medium Cycle time: 1.2 sec Acquisition method: EZ Method (scheduled SRM) www.unitedchem.com

SELECTRA AQUEOUS C18 HPLC COLUMNS Lot to Lot Reproducibility Selectra Aqueous C18 columns are manufactured under strict quality control guidelines which supports UCT s ongoing tradition of lot-to-lot consistent performance. Lot 1 RT:. - 17. SM: 7G 6.32 8.93 13.34 Column: UCT, Selectra, Aqueous C18, x 2.1 mm, 3 µm 95 Guard column: UCT, Selectra, Aqueous C18, x 2. mm, 3 µm 85 Column temperature: C 75 Column flow rate:. ml/min 65 Auto-sampler temperature: C Relative Abundance 55 45 Injection volume: µl Mobile Phase A: mm ammonium formate in water 35 Mobile Phase B:.1% formic acid in MeOH 25 15 5 4. 4.85 5.52 7.16 7.88 8.49.4.75 11.47 12.2 12. 14.56 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 Performance of 3 Selectra Aqueous C18 columns Lot 2 RT:. - 17. Relative Abundance 95 85 75 65 55 45 35 25 15 5 RT:. - 16.99 SM: 7G 4.87 5.44 5.96 6.32 7.28 7..22.94 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 Lot 3 95 SM: 7G 6.23 8.51 8.82 8.91 9.78 11.53 12.15 12. 13.29 13.22 14.51 Compound 3 lots total (n=61) RT (min) Rt RSD% Methamidophos 3.65 1.7 Acephate 4.41.6 Dicrotophos 5.94.5 o,o,o-triethylphosphorothioate 6.26.4 Dimethoate 6.26.4 Famphur 8.85.4 Malathion.37.5 Sulfotep 12.23.5 Diazinon 12.97.4 TPP 13.25.3 Pyrazophos 13.54.3 Profenofos 14.16.3 Ethion 14..2 Chlorpyrifos 14.61.2 85 75 65 Relative Abundance 55 45 35 25 15 5 4.23 4.73 5.15 5.79 7.36 7.76 8. 9.84.34.87 11.47 12.11 12.69 14.49 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16

Column Care & Usage Each UCT, Inc. high performance liquid chromatography (HPLC) column is individually packed and tested to ensure superior performance. A HPLC CoA is included with each column. It contains a chromatogram, the column serial number, and the lot number of the packing material. Retain this information for as long as you have the column; it may be useful if troubleshooting is ever required. Guard Columns & Filters The use of in-line filters and/or guard cartridges can prolong the life of an analytical column. Commonly used to capture impurities that may otherwise lodge on the HPLC column, they are especially useful with samples emanating from a biological source. Guard cartridges should be the same phase as the column they are protecting and be replaced when the chromatography begins to deteriorate or when excessive back pressure is noted on the HPLC system. Pressure Recommendation UCT, Inc. HPLC columns are silica based. To ensure optimal column life, operating pressures of psi or lower are recommended. Pressures may increase with time due to accumulation of particulates on the column. Sudden increases in pressure are usually a result of a blocked frit. Make note that pressure will vary with different mobile phase systems. For example Water/ Methanol mixtures will generally give higher back pressure than Water/Acetonitrile mobile phases. 215.781.9255.385.3153

SELECTRA AQUEOUS C18 HPLC COLUMNS Mobile Phase When shipped, the column contains the storage solvent listed on its HPLC CoA. Before initial usage, ensure that your planned mobile phase system is compatible with this solvent. If it is not, you must flush the column with an intermediate solvent that is compatible with both the storage solvent and your planned mobile phase. Be especially cognizant if you are using buffers; the storage solvent for most columns contains greater than % organic solvent, and contact with a buffer could cause a salting out effect. The resulting precipitate can plug the column. Flow Direction & Flow Rate The arrows on the column label indicate the recommended flow direction. Begin by connecting the inlet end of the column to the injector or autosampler and allow mobile phase to flow from the outlet end of the column into a beaker for 15 minutes. Gradually increase the flow rate. Next, stop the mobile phase flow and connect the column to your detector. Because every LC system is unique, especially when used in gradient mode, your results may slightly differ from those obtained in our laboratory. UCT, Inc. technical service can assist you in optimizing your separations. Be sure to record the operating pressure before calling. Increasing Column Lifetime Silica based UCT, Inc. HPLC column packing materials have a ph operating range of 2-8. Extended use of any column at extreme ph can shorten column lifetime. The upper temperature limit for silica based HPLC columns is C. Elevated temperatures can improve efficiency by lowering solvent viscosity, but column lifetime may be compromised. Use of HPLC-Grade solvents is strongly recommended. Residue and chemical contaminants in non-hplc grade solvents can alter a column s selectivity and, potentially plug the inlet frit leading to an increased system pressure. Mobile phase filtering and degassing (either off-line or in-line) is highly recommended. Column lifetime is also governed by stationary phase type. Hydrocarbon phases, such as C18, are relatively chemically inert. Polar phases, such as cyano or amino, require somewhat more care as they can be chemically active.

Column Maintenance Columns should not be subjected to mechanical or pressure shock. This can cause irreversible damage to the column. Columns should be run in the flow direction as marked on the column. The one exception is for column cleaning. The flow can be reversed to back-flush frits if blockages occur. Do not store the column in an aqueous buffer, this will promote microbiological contamination. First flush the column with water and then with / organic solvent/water prior to storage. Washing Procedure for Reverse-Phase Columns Washing the column successively with non-polar eluents will usually remove accumulated impurities. Follow the washing sequence below, using ml of each solvent, to thoroughly clean the column. 1. Distilled water %, % Methanol 2..5M H 3 P 4 %, % Methanol (Optional)* 3. Distilled water %, % Methanol (Optional)* 4. Methanol 5. Methanol/Chloroform (1:1) (Optional) 6. Methanol or Acetonitrile (Optional) 7. Distilled water %, % Methanol 8. Eluent to recondition column *NOTE: Whenever step 2 is used, it must be followed by step 3. It is recommended that columns be dedicated for the specific method when ion pairing reagents are used. This is because it is difficult to remove all of the ion pairing reagent. Protein Contamination Proteins can adsorb onto columns causing loss of performance. In this situation, rinse the column overnight with %.1M nitric acid/% isopropanol at a flow rate of 1/5th the usual flow rate (i.e. at.2 ml/min for 4.6mm ID columns). Ensure that the rinse solution is sent directly to solvent waste and not through the detector. Lipid Contamination If lipids or other highly hydrophobic compounds have contaminated the column use the full washing procedure except replace step 5 with % chloroform or dichloromethane. 215.781.9255.385.3153

SELECTRA AQUEOUS C18 HPLC COLUMNS PRICES AND TERMS Our prices are subject to change without notice. The price in effect when we receive your order will apply. All prices are in US Dollars and are F.O.B. Terms of payment are net days. MINIMUM ORDERS We welcome all orders, therefore, we do not have a minimum order requirement. When ordering, please include your purchase order number, complete Ship To and Bill To address, catalog number, quantity, and description of product(s). Also include your name and a phone number where you can be reached should we have any questions concerning your order. SHIPMENTS Normal processing is within 24 hours after receipt of an order. Unless special shipping requests have been made, our trained staff will send all orders by UPS Ground service. The appropriate shipping charges (freight & insurance costs) will be added to the invoice, unless otherwise instructed by the customer. SPECIAL PRICING We offer special pricing for volume purchases and standing orders. These discounts apply to bonded phase extraction column purchases only. Please call a sales representative for more information on special pricing qualifications. RETURN POLICY Our Quality Manager will handle all returns. Before returning merchandise, please call to obtain a return authorization number from the quality manager. We will need to know the reason for the return, date of purchase, purchase order number and invoice number in order to issue a return authorization number. Return merchandise must be received before a credit can be issued. Returns will not be accepted after days. A restocking fee of 25% of the price paid, or a minimum of $25. (whichever is greater) will be charged on all returns. WARRANTY All products manufactured by UCT are guaranteed against defects in materials and workmanship for a period of days after shipment. UCT will replace any items that prove to be defective during this time period. The exclusive remedy requires the end user to first advise UCT of the defective product by phone or in writing. Secondly, the defective product must be returned within days after proper approval from our Quality Manager. All returns must indicate the purchase order number, the lot number and the shipping date. UCT s total liability is limited to the replacement cost of UCT products. This warranty does not apply to damage resulting from misuse. Contact Us Phone: 215.781.9255.385.3153 Fax: 215.785.1226 UCT, Inc. 2731 Bartram Rd. Bristol, PA 7 Email: info@unitedchem.com Web: www.unitedchem.com 57-3-1 UCT