FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended for: DN 0 DN 0 Required accessory: able type FVone-NP- (Plug-in type) Recommended for: DN DN 0 Required accessory: Sensor adapter TP or all valve V able type 0 ompact flow meter for air, compressed air, nitrogen, oxygen, argon, carbon dioxide and methane. Measured values: standard volume flow/mass flow, standard flow speed, totalizer/consumption, temperature Wear-resistant compact design, with stainless steel monitoring head and housing Features Ordering information Flow meter (calorimetric) FVone FlowVision one Housing NP ompact housing Firmware Flow measurement of gases Power supply U D V Process connection 00 Push-in type, L=00 mm, threaded installation bush as accessory Push-in type, L=00 mm, threaded installation bush as accessory 0 Screw-in type, thread G/ (to DIN -), L = mm 0 Screw-in type, thread NPT/ -, L= mm Plug-in type (following DIN ISO ), L =, mm, for TP or V adapters Material (wetted parts) M Stainless steel. (standard material) M Hastelloy.0 M Titanium G. M Tantalum (coating 0 ± 0 µm), base material., only with process connection 0 and 0 M further materials upon request Electrical connection E Mx, -pole FVone- NP- - U- 0- M- E ordering example US interface enables configuration, display of measured values and data logging by P Software 0 m outputs for flow and temperature Pulse output Error indication output Two galvanically isolated relay outputs Totalizer power fail-safe 0 Inspection Report and Inspection ertificate see chapter. EDITION
0 0 General Data Suitable for Temperature range onfiguration Electrical data fluid TEHNIL DT (TU =, U = D V) FVone all types -... +0 push-in type ambience -... +0 Input voltage U D V (... V) Power consumption air, compressed air, nitrogen, oxygen, argon, carbon dioxide, methane, further gases upon request -... + with a distance of 0 cm between fluid and electronic housing via US by P software, runs on Windows XP, Windows Vista, Windows, Windows, Windows 0 () max. 0 m nalogue outputs flow and temperature 0 m ( bit) Relay outputs flow or temperature galvanically isolated, /D V, max. 0, Transistor outputs Power indication onnection MTTF (SN 00) Flow measurement () Measuring range 0 Nm/s (operating range () () 0 00 Nm/s) ccuracy () Repeatability () Pulse output (comsumption) and error indication output Volume flow depends on inner pipe diameter plug-in type screw-in type/ push-in type Power Fet, high side switch, short circuit proof max. load 00 m, inductive load max. 00 m LED (green) M connector, -pole years mm, TP-0 0 0 Nm³/h (0 Nm³/h) 0 mm, TP-0 0 Nm³/h (0 Nm³/h) mm, TP/V-0 0 0 Nm³/h (0 Nm³/h) mm, TP/V-0 0 Nm³/h (0 Nm³/h) 0 mm, TP/V-0 0 0 Nm³/h (0 Nm³/h) 0 mm, TP/V-0 0 Nm³/h (0 0 Nm³/h) 0 mm 0 Nm³/h (0 0 Nm³/h) 0 mm 0 Nm³/h (0 Nm³/h) 0 mm 0 Nm³/h (0 0 Nm³/h) 0 mm 0 Nm³/h (0 0 Nm³/h) 00 mm 0 Nm³/h (0 Nm³/h) 0 mm 0 Nm³/h (0 0 Nm³/h) 0 mm 0 Nm³/h (0 Nm³/h) 0 mm 0 Nm³/h (0 Nm³/h) 0 mm 0 Nm³/h (0 Nm³/h) 00 mm 0 Nm³/h (0 0 Nm³/h) 0 mm 0 0 Nm³/h (0 Nm³/h) 00 mm 0 0 Nm³/h (0 Nm³/h) 00 mm 0 0 Nm³/h (0 Nm³/h) 00 mm 0 0 Nm³/h (0 0 Nm³/h) 00 mm 0 Nm³/h (0 0 Nm³/h) 00 mm 0 00 Nm³/h (0 0 Nm³/h) 000 mm 0 Nm³/h (0 Nm³/h) 00 mm 0 Nm³/h (0 0 Nm³/h) 00 mm 0 0 Nm³/h (0 Nm³/h) Response time T s () Response time T 0 s () Temperature drift (+0 +0 ) 000 mm 0 0 Nm³/h (0 0 Nm³/h) 0 % of measuring range ±, % of measured value ± 0, % of measuring range final value 0 00 % of measuring range ± % of measured value ± % of measuring range final value 0 % of measuring range ± % of measured value ± 0, % of measuring range final value 0 00 % of measuring range ± % of measured value ± % of measuring range final value ± % of measured value ± 0, % of measuring range final value ± 0,0 % of measuring range final value/ EDITION
Pressure drift Temperature Measurement TEHNIL DT (TU =, U = D V) Measuring range -0 + approx. ± 0, % of measured value/bar ccuracy ± % of measuring range () Mechanical data and size of monitoring head plug-in type following DIN ISO screw-in type G /, NPT / push-in type Pressure resistance of monitoring head Degree of protection Materials Weight fitting, sensor (wetted) connection sensor/fitting shank diameter mm, length 00 mm/00 mm 00 bar, higher pressures with Inspection ertificate., observe pressure resistance of installation IP (when plugged in) stainless steel. (standard) laser welded housing stainless steel. M connector cap o-rings plug-in type screw-in type push-in type 00 mm push-in type 00 mm () t constant temperature and flow conditions, and stable thermal conductivity. uzn, nickel-plated P FKM (wetted, plug-in and push-in type) ca. 0 g ca. 0 g ca. 0 g ca. 0 g () The accuracy values were determined under ideal conditions: Symmetrical complete flow profile, correct mounting in the pipe, inlets and outlets according to manual. () Measuring range (operating range) for methane: TP-0: 0 Nm³/h (0 Nm³/h) TP-0: 0 Nm³/h (0 Nm³/h) TP/V-0: 0 0 Nm³/h (0 Nm³/h) TP/V-0: 0 Nm³/h (0 Nm³/h) TP/V-0: 0 0 Nm³/h (0 Nm³/h) TP/V-0: 0 Nm³/h (0 0 Nm³/h) Screw-in/Push-in type: 0 Nm/s (0 00 Nm/s) - Nm³/h depends on pipe diameter, see table () Requires.NET Framework (is provided for free by Microsoft, usually already installed) and Windows with current updates () t constant flow rate; fast changes of flow rate may temporarily cause greater deviation than stated. () Measured at a flow of 0 Nm/s after a sudden complete stop. () Valid up to bar abs., > bar abs. upon request. () Specifications in Nm³/h and Nm/s refer to 0 mbar, 0. Sensor calibration is performed at approx. and approx. 0 mbar abs. in TP-0, inside pipe diameter, mm (screw-in type) and inside pipe diameter, mm (push-in type) respectively. Windows and Windows Vista are either registered trademarks or trademarks of Microsoft orporation in the United States and/or other countries. 0 0 EDITION
0 P Software Information/General settings: Information about the connected device (type, firmware) onnection status Selection of application language onfiguration: asic settings (fluid, standard conditions, inside pipe diameter, averaging ) Selection of units for volume flow, speed, totalizer, temperature onfiguration of analogue outputs, switching outputs, pulse output and error indication output Loading and saving the configuration to the hard disk Plausibility check all up factory settings 0 Operation: Recording of measured values export to Microsoft Excel Setting of the readout interval Shows the actual measured values (volume flow, speed, totalizer, temperature) Shows the maximum and minimum values Shows the state of the switching and the error indication output Setting of the low flow suppression and execution of the zero point adjustment Shows which error occurred last Resetting of the totalizer value, the minimum and maximum values and the last error Visualisation: hart of the measured values volume flow, speed and temperature (maximum two simultaneously) Microsoft and Excel are either registered trademarks or trademarks of Microsoft orporation in the United States and/or other countries. EDITION
Nl/min, 0, 0 00 0, volume flow rate in Nl/h 0 0 0 0 0 000 Nm /h 0 0 000 00 0 Measuring and operating ranges The measuring/operating ranges are determined by the inner pipe diameter. They can be calculated with the following equation: Q = V N x R Q (Nm /h) - flow quantity V N (Nm/h) - average standard velocity R (m ) - inner pipe cross section Standard velocity measuring range (air, nitrogen, oxygen, argon, carbon dioxide): 0... Nm/s Standard velocity measuring range (methane): 0... Nm/s Standard velocity operating range (all gases): 0 00 Nm/s DN00 DN0 DN00 DN0 DN00 DN0 DN DN00 DN0 DN DN0 DN0 DN DN DN0 DN 0, 00 0, 0, 0,0 0 0,0 0,00 0,0 0,0 0, 0, 0 0 00 average flow speed in Nm/s 0 EDITION
Electrical connection 0 0 FVone onnector top view braun/brown + D V + D V blau/blue GND GND weiß/white reserviert/reserved grün/green reserviert/reserved rosa/pink Last/load max. 00 m Fehlermeldung/error gelb/yellow Last/load max. 00 m Pulsausgang/pulse output schwarz/black Relais /relay /D V, max. 0, grau/grey Relais /relay rot/red Relais /relay 0 /D V, max. 0, violett/purple Relais /relay grau-rosa/grey-pink 0/ 0 m Temperatur/temperature rot-blau/red-blue Last/load max. 00 Ω Last/load max. 00 Ω 0/ 0 m Durchfluss/flow EDITION
Dimensions ll dimensions in mm 0 0 ll dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. EDITION
FVone-NP- Sensor adapter TP, V 0 0 Sensor adapter TP/all valve V Features TP-... ccessories V-... orrect positioning of sensor Ease of sensor replacement Measuring point can be closed if not used Sensor adapter available as screw-in or welding type all valve also serves as a shutoff valve (both input and out output) Description lanking plug, brass, with O ring Ref. No. 0ZZ000 Union nut, brass Y 0 0 0 lanking plug, stainless steel./isi Ti, with viton O ring 0ZZ000 Union nut, stainless steel Y 0 0 0 Description Sensor adapters TP and V facilitate correct positioning and exchange of FVone... (plug-in type connection) in pipes with process connection DN...DN 0. all valve V enables pressure-free installation or removal of FVone... (plug-in type connection) simply by closing the input and output pipe. The measuring points are suited to temporary measurements; after completion of the measuring cycle they can be closed by means of blanking plugs. Ordering information sensor adapter TP/thread TP Ordering information sensor adapter TP/welding Ordering information ball valve V Sensor adapter with internal thread Process connection/nominal size 0 DN G / internal thread length: 0 mm/. in. 0 DN 0 G / internal thread length: mm/. in. 0 DN G internal thread length: mm/.0 in. 0 DN G / internal thread length: mm/.0 in. 0 DN 0 G / internal thread length: 0 mm/. in. 0 DN 0 G internal thread length: mm/. in. Material of the area exposed to fluid M stainless steel./isi Ti PN bar/0 psi M brass (not TP-0..) PN bar/ psi M red brass (only TP-0..) PN bar/ psi TP - 0 M ordering example TP Sensor adapter with welding nipples Process connection/nominal size 0 DN dia.d: mm/.0 in. length: 0 mm/. in. 0 DN 0 dia.d: 0 mm/. in. length: 0 mm/. in. 0 DN dia.d: mm/. in. length: 0 mm/. in. 0 DN dia.d: mm/. in. length: 00 mm/. in. 0 DN 0 dia.d: 0 mm/. in. length: 0 mm/. in. 0 DN 0 dia.d: 0 mm/. in. length: 0 mm/. in. Material of the area exposed to fluid M stainless steel./isi Ti Process connection S welded connection TP - 0 M - S ordering example ball valve with internal thread Process connection/nominal size 0 DN G internal thread length: mm/. in. 0 DN G / internal thread length: 00 mm/. in. 0 DN 0 G / internal thread length: 0 mm/. in. 0 DN 0 G internal thread length: mm/. in. Material of the area exposed to fluid M nickel plated brass, Delrin seal V - 0 M ordering example EDITION
FVone-NP-... Sensor adapter TP, V Dimensions TP- sensor adapter with internal thread SW G t Material stainless steel (-M): PN bar / psi Material brass (-M): PN bar / psi Material red brass (-M): PN bar / psi L DN dia. d G t L SW mm in. mm in. in. mm in. mm in. mm in. TP-0..0 /. 0..0 TP-0 0. 0. /... TP-0....0 0. TP-0.../..0 0. TP-0 0. 0../. 0.. TP-0 0. 0... 0. TP- M-S sensor adapter with welding nipples t ød SW = width across flats 0 SW ød ød H t L PN bar / psi DN dia. d dia. D t L SW mm in. mm in. mm in. mm in. mm in. mm in. TP-0M-S..0... 0..0 TP-0M-S 0. 0...0. 0.. TP-0M-S..... 0. 0. TP-0M-S..... 00. 0. TP-0M-S 0. 0...0. 0.. TP-0M-S 0. 0. 0... 0. 0. V- M all valve with internal thread PN bar / psi L t DN dia. d G t L SW H mm in. mm in. in. mm in. mm in. mm in. mm in. mm in. V-0M....... V-0M.../. 00. 0... V-0M 0. 0../. 0...0 0. V-0M 0. 0..0. 0.. 0. This is a metric design and millimeter dimensions take precedence ( mm ) inch t ød G SW 0 EDITION
FVone-NP- 00/ ccessories Threaded installation bush PTFE sealing ring for threaded installation bush 0 0 Suitable up to bar/ psi abs. if used with push-in sensors. Please observe assembly instructions and safety guidelines! Metal sealing ring can t be disassembled after assembly. Ordering information threaded installation bush VK threaded installation bush Process connection 0 thread R/ ore D mm Material M stainless steel. M Hastelloy.0 M tantalum (coating 0 ± 0 µm), base material. M further materials upon request VK - 0 D M ordering example Suitable for threaded installation bush VK-0D pplicable up to bar/ psi abs. if used with push-in sensors and threaded installation bush VK. Ordering no.: Y0000 Locking set Locking set for push-in sensors. Ordering no.: 0ZZ0000 hain x DIN (approx. m) atch for chain NG lip with screw and nuts DN to DIN 0 0 EDITION
FVone-NP- able able type with connector Description Shielded connecting cable M for flow meter FVone-NP for electrical connection of supply voltage and outputs. Technical data Degree of protection: IP (only if connector plugged in) Temperature range: -0... +0 Insulation resistance: 0 MΩ x km Withstand voltage: 00 V ending radius: mm Ordering information Do + Ka Do + Ka - m PV insulated cable x0, mm², shielded with connector, -pole, M- m available cable lengths: m, m, 0 m, m, 0 m,, 00 m (in 0 m steps) ordering example 0 0 EDITION