Abstract Submitted for the DPP99 Meeting of The American Physical Society

Similar documents
UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

GA A23198 HORIZONTAL THOMSON SCATTERING SYSTEMS FOR DIII D AND SSPX

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

GA A22337 INITIAL OPERATION OF THE DIVERTOR THOMSON SCATTERING DIAGNOSTIC ON DIII D

Recent improvement of the LHD Thomson scattering system

Development of Polarization Interferometer Based on Fourier Transform Spectroscopy for Thomson Scattering Diagnostics

The details of point source helicity injection as a noninductive startup technique must be characterized:

channel system which covers both sides of the laser line. Coverage on both sides of the spectrum allows for

Improved absolute calibration of core Thomson scattering(ts) diagnostics on Alctor C-Mod

Design study of the divertor Thomson scattering system for JT-60SA

IMPURITY ANALYSIS AND MODELING OF DIII-D RADIATIVE MANTLE DISCHARGES

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

HYDROBETA: A NEW INSTRUMENT FOR MEASURING IN-SITU PROFILES OF THE VOLUME SCATTERING FUNCTION FROM 10 TO 170 DEGREES

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Performance Assessment of the C-Mod Multi-Spectral Line Polarization MSE (MSE-MSLP) Diagnostic

PoS(PD07)031. General performance of the IceCube detector and the calibration results

Measuring Laser Diode Optical Power with an Integrating Sphere

Lab VI Light Emitting Diodes ECE 476

Diagnostics for Burning Plasma Physics Studies: A Status Report.

High Resolution Optical Spectroscopy

OPTICAL GAIN AND LASERS

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Measurements of photon scattering lengths in scintillator and a test of the linearity of light yield as a function of electron energy

Plasma Spectroscopy in ISTTOK

Initial Experimental Program Plan for HSX

Measurement of orbital angular momentum of a single photon: a noninterferrometric

DEPENDENCE OF THE H-MODE PEDESTAL STRUCTURE ON ASPECT RATIO

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

Development of a Lithium Beam Probe and Measurement of Density Pedestal in JT-60U

Background Information:

RICH detectors for LHCb

Burner Tubing Specification for the Turbulent Ethylene Non-Premixed Jet Flame

Development of Polarization Interferometer for Thomson Scattering Diagnostics in JT-60U

requency generation spectroscopy Rahul N

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Application of atomic data to quantitative analysis of tungsten spectra on EAST tokamak

Invessel Calibration of the Alcator C-Mod MSE Diagnostic

Parametric down-conversion

Dependence of non-local effects on plasma parameters during cold-pulse experiments in Alcator C-Mod

The low Q 2 chicane and Compton polarimeter at the JLab EIC

The current status of the Lithium beam diagnostic at ASDEX Upgrade

The Compton backscattering Polarimeter of the A4 Experiment

Optic Detectors Calibration for Measuring Ultra-High Energy Extensive Air Showers Cherenkov Radiation by 532 nm Laser

UEDGE Modeling of the Effect of Changes in the Private Flux Wall in DIII-D on Divertor Performance

Progress Report on the A4 Compton Backscattering Polarimeter

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

GA A23797 UTILIZATION OF LIBEAM POLARIMETRY FOR EDGE CURRENT DETERMINATION ON DIII-D

GA A22443 STUDY OF H MODE THRESHOLD CONDITIONS IN DIII D

LIBSlab ANALYZERS ANALYZERS

INTERFEROMETER SYSTEMS ON LHD

Interference. Part-2. Gambar: Museum Victoria Australia

Characterisation & Use of Array Spectrometers

In-situ wavelength calibration and temperature control for the C-Mod high-resolution X-ray crystal imaging spectrometer

Laser Plasma Monochromatic Soft X-ray Source Using Nitrogen Gas Puff Target

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

DIAGNOSTICS FOR ADVANCED TOKAMAK RESEARCH

Abstract. PEGASUS Toroidal Experiment University of Wisconsin-Madison

arxiv: v2 [physics.ins-det] 17 Jun 2014

Progress of Confinement Physics Study in Compact Helical System

Measurement method for the proficiency testing program

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

Development of a High-Speed VUV Camera System for 2-Dimensional Imaging of Edge Turbulent Structure in the LHD

Fabry-Perot Interferometer for atmospheric monitoring useful for EAS detection E.Fokitis 1, K. Patrinos 1, Z. Nikitaki 1

ATLAS Tile Calorimeter Calibration and Monitoring Systems

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

Introduction to FT-IR Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

FLASH. FLuorescence in Air from SHowers (SLAC E-165) Pisin Chen SLAC. Report to DOE HEP Review SLAC, June 2-4, 2004

Analytical Chemistry II

Diagnósticos em Plasmas

Large Plasma Device (LAPD)

Raman and stimulated Raman spectroscopy of chlorinated hydrocarbons

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

NIRSpec Performance Report NPR / ESA-JWST-RP Authors: T. Böker, S. Birkmann & P. Ferruit Date of Issue: 20.5.

1. The range of frequencies that a measurement is sensitive to is called the frequency

Institute for Laser Technology

ILC Laser-wires. G A Blair, RHUL Snowmass 17 th August 2005

Multi-Purpose Nonlinear Optical Microscope. Principle and its Applications to Polar Thin Film Observation

X-Ray Measurements of the Levitated Dipole Experiment

Confocal Microscope Imaging of Single emitter fluorescence and Observing Photon Antibunching Using Hanbury Brown and Twiss setup. Lab.

Chemistry Instrumental Analysis Lecture 15. Chem 4631

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Studies of Turbulence and Transport in Alcator C- Mod H-Mode Plasmas with Phase Contrast Imaging and Comparisons with GYRO*

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

EO single-shot temporal measurements of electron bunches

Plasma Radiation. Ø Free electrons Blackbody emission Bremsstrahlung

The Photoelectric Effect and the Quantization of Light

Electron Thermal Transport Within Magnetic Islands in the RFP

- he [I+ P,P,A (~%)l,

Lecture 20. Wind Lidar (2) Vector Wind Determination

Chem 310 rd. 3 Homework Set Answers

PoS(PSTP 2013)034. Precession Polarimetry at JLab, 6 GeV. G.B. Franklin Carnegie Mellon University

Chamber Development Plan and Chamber Simulation Experiments

Thomson Scattering from Nonlinear Electron Plasma Waves

Heat Flux Management via Advanced Magnetic Divertor Configurations and Divertor Detachment.

Transcription:

Abstract Submitted for the DPP99 Meeting of The American Physical Society Sorting Category: 5.1.1.2(Experimental) Calibration of a Three Path Thomson System at DIII- D 1 B.D. BRAY, C.L. HSIEH, T.N. CARLSTROM, General Atomics The Thomson system measures electron density and temperature with eight pulsed ND:YAG lasers along three paths through the plasma. Two vertical paths provide measurements in the lower divertor and core of the plasma and a third horizontal laser path was installed in 1999 to extend the measurements to the center of the plasma. The components of the new system must be carefully calibrated so the measurements can be combined into a single profile. A monochromator calibration and opto-electronic calibration measure the absolute sensitivity of the detector system dc and pulsed response, respectively. A Rayleigh scattering calibration and transmission calibrations measure the sensitivity of the system to scattered light. The calibrations are checked by a comparison of overlapping channels in the core system and between the core and horizontal systems. The contributions of the background and scattered light to the systematic and statistical uncertainties of the measurement must be understood to make these channel to channel comparisons. 1 Supported by U.S. DOE Contract DE-AC03-99ER54463. X Prefer Oral Session Prefer Poster Session B.D. Bray bray@gav.gat.com General Atomics Special instructions: DIII-D Poster Session 2, immediately following DM Thomas Date printed: July 16, 1999 Electronic form version 1.4

Introduction The Thomson system measures electron temperature (Te) and density (ne) profiles at DIII-D 44 viewing locations on three laser paths measure profiles in the core and divertor regions of the plasma A horizontal path was added in 1999 to extend the core measurements toward the center of the plasma. Extensive effort is necessary to produce the small (10%) normalization variation in the core ne measurement Currently, the calibration and alignment systems are being upgraded to further limit the effect of systematic errors on the profiles with reduced effort 1

Thomson Scattering Measured with 8 4 Vertical, 3 horizontal and 1 Divertor lasers fire at 20 Hz. Pulsed YAG Lasers The vertical and horizontal lasers are spaced 150 µs apart Light from the vessel is focussed on an array of viewing fibers. Background and signal levels for each viewing location are measured with a 6 wavelength channel polychromator 2

Polychromators have a Large Temperature and Density Range Each polychromator contains 6 band pass filters and APDs A filter at 1064nm is used to calibrate the detector with Rayleigh scattered light, the other channels measure the Thomson scattered light from the plasma Short wavelength filters are sensitive to high Te and long wavelength to low Te 3

Thomson Viewing Locations The three laser paths measure n e and T e in the divertor, and core regions. The data is combined to give profiles throughout the plasma. Because different lasers are used to measure the points along the different paths, the systematic errors between lasers as well as point to point become significant in the fits. 4

Thomson Density Is Cross Calibrated with CO 2 Interferometer CO 2 interferometer line integrals are compared with the core Thomson data. Typically the difference in the normalization factor is less than 10% The new horizontal points near the center of the plasma are not as well constrained by the CO 2 line integrals as the vertical core measurements Divertor profiles cannot be normalized to other diagnostics so the stability of the calibration cannot be crosschecked 5

Model Dependence of Thomson Density Profiles Density profiles are normalized to the CO 2 interferometer. 8 Model 1 Density PROFILE Thomson Data Changes in the model can change the relative CO 2 normalization and shift the central density of the Thomson profiles 10% due to the model dependence Better calibrations and alignment can reduce point to point and laser to laser variations, which influence these fits n e (10 19 m -3 ) 6 4 2 = Core = Tangential 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Normalized ρ n e (10 19 m -3 ) 8 6 4 Model 2 Density PROFILE Thomson Data = Core = Tangential 2 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 6

Detailed Calibrations Required for Good Measurements The Thomson system s careful calibration results in good consistency with the CO 2 measurements. Every aspect from the laser energy entering the vessel, through the window and fiber attenuation, to the relative gain of the digitizer channels is calibrated. The alignment of the lasers is carefully monitored in relation to the viewing locations of each channel to assure the quality of the data. The density measurements are especially sensitive to any calibration uncertainties since the density is proportional to the total observed signal. The temperature is determined by the relative distribution of the signal in the polychromator 7

Three Primary Calibrations Needed The Opto-electronic calibration measures the ratio of the pulsed response to a laser pulse and the DC response of the detectors. The DC Spectral Calibration measures the spectral response of the polychromator channels and is combined with the optoelectronic calibration to give the pulsed spectral response. The Temperature is determined by the ratio of signals on the polychromator channel with these calibrations The Rayleigh Calibration measures the acceptance and response of the YAG detector with Rayleigh scattered light from Ar gas. The density is determined by scaling the Thomson cross section to the Rayleigh cross section, the observed Rayleigh sensitivity, and the polychromator spectral calibration 8

Opto-electronic Calibration Two 1060 nm LEDs are used to measure the ratio of pulsed gain for a pulse which mimics the laser pulse shape and DC gain All detectors for a single polychromator are measured simultaneously to control systematic effects from the measurement of the absolute light level An additional correction is added for the relative gate characteristics of the digitizer channels 9

Monochromator Used for Spectral Calibration Absolute DC response vs wavelength is combined with the pulsed to DC ratio to give the pulsed response of each detector. Systematic errors due to the wavelength calibration of the monochromator at the YAG line must be carefully controlled to accurately measure the narrow Rayleigh filter. 10

Rayleigh Scattering Used For Density Rayleigh scattering from Ar gas measures the sensitivity of the polychromator to scattered YAG light. Measurements between operation periods monitor any degradation in the collection optics. The stray light (light reflected from the laser exit tube rather than the gas) must be carefully controlled during the Rayleigh measurement Calibration 11

Careful Alignment Is Needed for Consistent Rayleigh Measurements Approximately 5% systematic error in the core density due to low stray light and reproducible alignment Tangential and Divertor channels have larger errors due to high stray light levels. 12

Background Light Corrections Needed For Some Shots A differential amplifier subtracts most of the background light from the pulsed channel but an additional calibration is needed to correct the pulsed signal at high background levels. Corrections can be up to 3% of the total signal level for high background data 13

Calibration Corrections Improve Thomson Profiles Corrections for the digitizer gain and background correction produce more self-consistent density and temperature profiles for the core system. 14

Alignment Modifications Will Improve Future Measurements Alignment Feedback A new beam monitor and feedback system is being installed for 2000 operations. The ND:YAG lasers will be automatically aligned shortly before the shot by making them co-linear with the HeNe guidance laser beams. Alignment Targets Internal alignment targets are currently used to align core and horizontal system. An additional alignment target will be added for the divertor system to improve alignment. 15

Additional Modifications Will Improve Measurements Divertor Exit Baffles Redesign and extend the divertor baffles to lower stray light levels. The divertor Rayleigh measurement is currently problematic due to extremely high stray light levels. In-situ Opto-electronic gain monitors Reduce problems with the digitizers and monitor gain during operations Gain resistors Changing the gain resistor in the APD electronics will lower the background gain relative to the pulsed gain and improve the dynamic range of the system and lower sensitivity to changes in the background light level 16

Summary Current Thomson measurements ~10% density point to point systematic error + 10% path normalization for the core. Our goal is to reduce this to a 5% point to point and 5% path normalization and achieve similar confidence in the divertor density measurements. Improved calibrations have produced a better understanding of the dominant systematic effects in the Thomson system and suggested several improvements. Hardware installation is being completed for the feedback system and divertor baffles. This should produce further improvements in the systematic uncertainties in the density measurement by improving the alignment and reducing the stray light. 17