TSI AEROTRAK REMOTE 4-20 ma SENSORS LIFE SCIENCE

Similar documents
CALIBRATION CERTIFICATE FAILURE EXPLANATION FOR AEROTRAK PARTICLE COUNTERS

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

MACROIMS MACROION MOBILITY SPECTROMETER MOLECULAR WEIGHT AND PARTICLE SIZE DETERMINATION OF POLYVINYLPYRROLIDONE (PVP)

Fundamentals of Particle Counting

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

CARBON NANOTUBE ANALYSIS USING THE TSI LIBS DESKTOP ANALYZER

ISO STANDARD INTERNATIONAL. Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness

NANOSCAN SMPS SPECTROMETER COMPARED TO THE TSI SMPS SPECTROMETER

MEASURING NANOPARTICLE EXPOSURE

Heat Flow Calculations Made Using the Models 8386 and 8386A VELOCICALC Plus Air Velocity Meters Application Note ITI-124

ISO INTERNATIONAL STANDARD

Estimation of Mass with the Model 3321 APS Spectrometer

Cleanrooms and associated controlled environments. Part 1: Classification of air cleanliness by particle concentration

Application of Micro-Flow Imaging (MFI TM ) to The Analysis of Particles in Parenteral Fluids. October 2006 Ottawa, Canada

Determination of particle size distribution Single particle light interaction methods. Part 4:

Spa & Wellness for Pipettes

Swiss Medic Training Sampling

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

ab Cervix cancer tissue array of 102 cases (1.5mm)

Testing for particles in injectable products

CiA Draft Standard Proposal 447

ISO INTERNATIONAL STANDARD

ab Alkaline Phosphatase Assay Kit (Luminometric)

Lump and Neckdown Detection Using Scanning Laser Micrometers

ISO INTERNATIONAL STANDARD

ab83360 Ammonia Assay Kit

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

Eye Safety With LED Components

AN1755 APPLICATION NOTE

Particle number concentration standards at NMIJ, including a new calibration service with an inkjet aerosol generator.

The solution for all of your

of mass spectrometry

AN1542 APPLICATION NOTE

HCF4089B BINARY RATE MULTIPLIER

ab DCF ROS/RNS Assay Kit (biofluids, culture supernatant, cell lysates)

7.5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED. October 2002

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

AP Calculus AB. Sample Student Responses and Scoring Commentary. Inside: Free Response Question 1. Scoring Guideline.

for XPS surface analysis

The Coulter Principle for Outlier Detection in Highly Concentrated Solutions

SOP SMPS BaltimorePM supersite Version /29/01 Page 1 of 13 SMPS

INTERNATIONAL STANDARD

FEDERAL STANDARD 209E. Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones

Controlled Environment Testing Report

RS 1700/1900/2300/2900 High Density Reticle Stockers

AN2970 Application note

ab MDA Assay Kit (competitive ELISA)

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

ab83360 Ammonia Assay Kit

Introduction to Fourier Transform Infrared Spectroscopy

ISO INTERNATIONAL STANDARD. Water quality Determination of dissolved bromate Method by liquid chromatography of ions

ISO INTERNATIONAL STANDARD

The Fundamentals of Moisture Calibration

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Fact sheet on Intermediates under REACH

Spa & Wellness for Pipettes

L7800 SERIES POSITIVE VOLTAGE REGULATORS

Thermal correction - workpiece expansion. Thermal correction - workpiece expansion AP306. Problem

L7800 SERIES POSITIVE VOLTAGE REGULATORS

ELECTROSTATIC CLASSIFIER MODEL 3082

AP Calculus BC 1998 Free-Response Questions

Safety Instrumented Systems & Functional safety of safety-related systems. A substantial new opportunity for Pfannenberg Signaling products

ST3L01 TRIPLE VOLTAGE REGULATOR

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

ISO INTERNATIONAL STANDARD

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

VIBRATING ORIFICE AEROSOL GENERATOR MODEL 3450

IBIDEN Group Green Procurement Guidelines. (Version 6)

ISO INTERNATIONAL STANDARD

Laser diffraction and automated imaging: complementary techniques for nasal spray development

STTH16R04CT. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes TO-220AB TO-220FPAB

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

M74HCT688TTR 8 BIT EQUALITY COMPARATOR

Data Sheet. Functional Safety Characteristic Safety Values for BE..(FS) Brakes * _0715*

Bindzil CC in the coating industry. Silane modified colloidal silica dispersions functions and applications

Data Sheet. Functional Safety Characteristic Safety Values for BE.. Brakes * _0715*

ISO Representation of results of particle size analysis Adjustment of an experimental curve to a reference model

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

White Paper. Moisture Analyzer Routine Testing

ITS. One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER SCIENCE

ISO 3741 INTERNATIONAL STANDARD

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

ab Caspase 3, Caspase 8 and Caspase 9 Multiplex Activity Assay Kit (Fluorometric)

1. Intended use. 2. Introduction. 3. Assay description. 4. Limitations. Instruction For Use Gyrolab Generic PK Kit

Introduction CR-288 APPLICATION NOTE FOR BEOL SEMICONDUCTOR PROCESSING. Authors: Christopher Wacinski and Wiley Wilkinson

AP Calculus AB 2008 Free-Response Questions Form B

Geostatistical Analyst. Statistical Tools for Data Exploration, Modeling, and Advanced Surface Generation

P D = 5 W / 6 W Transient Voltage Suppressor. Description. Package SZ-10. Features. Selection Guide. Applications. Typical Application

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of density Part 3: Oscillation method

Properties criteria - BETA

Impact of operators and pharmaceutical operations upon air quality of controlled atmosphere areas

C h a p t e r 5 : W o r k p l a c e H a z a r d o u s M a t e r i a l s I n f o r m a t i o n S y s t e m ( W H M I S )

For the rapid, sensitive and accurate measurement of Caspase 9 activity in cell and tissue lysates

Transcription:

TSI AEROTRAK REMOTE 4-20 ma SENSORS LIFE SCIENCE APPLICATION NOTE CC-118 (A4) Introduction There is a need for end users to integrate AeroTrak Remote Particle Counters into third party building management systems and PLCs. To meet this requirement, TSI has enhanced the range of AeroTrak Remote Particle Counters to include Linear and Log 4-20 ma scaled analog outputs in this application note. TSI now offers, for the first time to the end user, the opportunity to select either a Log or Linear scaled output. In this application note, we discuss why a 4-20 ma Log scaled output is an advantage when monitoring critical processes in regulated life science applications. As many of you already know, when a particle counter continuously monitors an aseptic manufacturing process, it is positioned to detect potential harm to the product. The purpose is to detect changes, transient events, particle excursions and deviations from processing norms that may pose an increased risk to the product or process. When an excursion occurs that exceeds predetermined action limits, a root cause investigation is performed. Section E of the FDA Aseptic Processing guidance 2004 clearly links the thoroughness of any root cause investigation to the severity of a particle excursion. E. Particle Monitoring Routine particle monitoring is useful in rapidly detecting significant deviations in air cleanliness from qualified processing norms (e.g., clean area classification). A result outside the established classification level at a given location should be investigated as to its cause. The extent of investigation should be consistent with the severity of the excursion and include an evaluation of trending data. Appropriate corrective action should be implemented, as necessary, to prevent future deviations. Using the currently available particle counters with Linear scaled 4-20 ma outputs means measuring the size of a particle event can be challenging. If it is not possible to quantify the size of a particle excursion, then it becomes difficult to determine the extent to which a root cause investigation should be performed. This application note will explain why this is the case and detail how the new TSI 4-20 ma remotes solve this problem. TSI, TSI logo, and AeroTrak are registered trademarks of TSI Incorporated.

Remote Operation In order to understand why it would be difficult to determine the size of a particle excursion, we must first examine how 4-20 ma sensors are integrated into building management systems or PLCs. TSI remotes have four size bands. The end user will select which two size bands are configured for a 4-20 ma scaled output. The sample interval is typically configured for one minute. The 4-20 ma output signal will represent the actual number of particles counted at the chosen sizes during that one minute sample period, it is not normalised. It follows therefore, that when a 1 cubic ft/min flow rate instrument is used with a sample interval of 1 minute the 4-20 ma output signal will be in counts per ft³. It is important to note that EU GMP Annex is very clear in that it is not necessary to configure large sample intervals (volumes) on remote particle counters when monitoring. The purpose of monitoring particles in critical processes is to detect transient events and enable an immediate end user response to that event. This is the reason the sample interval is typically one minute in life science applications. Increasing the sample interval leads to an increased risk that a transient event will not be detected When integrating a particle counter with 4-20 ma linear scaled outputs into a third party system, the end user needs to select a meaningful output range that will handle the level of particulate cleanliness in the area being monitored. This range must include the action and alert limits. Figure 1 details the possible Linear output ranges that can be selected for the TSI remotes. In the next section we will work through whether selecting a linear output range will provide meaningful data for your application. 4-20mA Analog Output with Logarithmic Characteristic *) 4-20mA Analog Output with Linear Characteristic *) 2 [log10(counts+10)]+2 (Counts x 16 / FS) + 4? Full Scale Full Scale Counts 2 1.E+02 1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 1.E+08 1.E+09 0 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 1 4.08 4.16 4.02 4.00 4.00 4.00 4.00 4.00 4.00 2 4.16 4.32 4.03 4.00 4.00 4.00 4.00 4.00 4.00 3 4.23 4.48 4.05 4.00 4.00 4.00 4.00 4.00 4.00 5 4.35 4.80 4.08 4.01 4.00 4.00 4.00 4.00 4.00 6 4.41 4.96 4.10 4.01 4.00 4.00 4.00 4.00 4.00 7 4.46 5.12 4.11 4.01 4.00 4.00 4.00 4.00 4.00 8 4.51 5.28 4.13 4.01 4.00 4.00 4.00 4.00 4.00 9 4.56 5.44 4.14 4.01 4.00 4.00 4.00 4.00 4.00 1.0E+01 4.60 5.60 4.16 4.02 4.00 4.00 4.00 4.00 4.00 1.0E+02 6.08 20.00 5.60 4.16 4.02 4.00 4.00 4.00 4.00 1.0E+03 8.01 20.00 5.60 4.16 4.02 4.00 4.00 4.00 1.0E+04 10.00 20.00 5.60 4.16 4.02 4.00 4.00 1.0E+05 12.00 20.00 5.60 4.16 4.02 4.00 1.0E+06 14.00 20.00 5.60 4.16 4.02 1.0E+07 16.00 20.00 5.60 4.16 1.0E+08 18.00 20.00 5.60 1.0E+09 20.00 20.00 *)Based on 16-Bit D/A converter design Example Figure 1 In this example, we are monitoring Grade B/ ISO 7 in operation, using a TSI Remote 7510-A2F. For simplicity we will consider counts @ 0.5 µm only. Page 2 of 5

The flow rate of the particle counter is 1 ft³/min (cubic foot per minute). A sample interval of 1 minute is configured. This means, as discussed in the previous section, that the 4-20 ma signal will be equivalent to counts/ft³. See the tables in Figure 2 below for the particle limits for 0.5 µm at ISO 7 and Grade B in operation. Clean Area Classification (0.5 µm particles/ft 3. ISO Designation b 0.5 µm particles/m 3 Microbiological Active Air Action Levelsc (cfu/m 3 ) Microbiological Settling Plates Action Levels c,d (diam. 90 mm; cfu/4 hours) 100 5 3,520 1 e 1 e 1000 6 35,200 7 3 10,000 7 352,000 10 5 100,000 8 3,520,000 100 50 Maximum permitted number of particles per m 3 equal to or greater than the tabulated size At Rest In Operation Grade 0.5 µm 5.0 µm 0.5 µm 5.0 µm A 3 520 20 3 520 20 B 3 520 29 352 000 2 900 C 352 000 2 900 3 520 000 29 000 D 3 520 000 29 000 Not defined Not defined Figure 2: US FDA 2004 (top) and EU GMP Annex 1 (bottom) Classification Tables Clearly, 0-100 (1E+02) and the 0-1,000 (1E+03) ranges, as detailed in Figure 1, are not large enough to output particle counts up to the limit of 10,000(1E+04) Counts/ft³ which is ISO 7. Would 0-10,000 (1E+04) work? It is tempting to think 0-10,000 counts/ft³ linear scale would be suitable. See the graph below for an example of a particle excursion over a 20 minute period when the 4-20 ma scale is set to 0-10,000 counts to see why it may not be appropriate. You can see that the graph reaches full scale (10,000 counts/ft³ or 20mA) during the event. The operator or manager when investigating this event has no idea if the counts were just over the Page 3 of 5

action limit or significantly over the limit. In other words it is impossible to determine the severity of the excursion from this graph when using this scale. Clearly the 0-10,000 scale is not suitable. Let us now examine the same data but using the next linear scale available to us. The graph below shows the same data but with a 0-100,000 linear scale selected on the TSI remote. It is now possible to asses the size of the particle excursion and perform an appropriate root cause investigation. It would be possible to measure a very large excursion on this scale. The broad range has now introduced a new problem, it has now become difficult to clearly distinguish low particle counts. Let us now examine the same data but this time using the 4-20 ma Log scaled output. The graph below shows the same data but this time with log scale selected on the TSI Remote. Page 4 of 5

It is now possible to asses the size of the particle excursion and perform an appropriate root cause investigation. It is now possible to distinguish small numbers of particles and very large numbers on the same graph. Discussion Presentation of data on a logarithmic scale is always helpful when data covers a large range of values which is very common in cleanroom environments. The TSI FMS software presents particle count information in a Log scaled format as it is recognised as the most effective way to present particle count data In this application note we have shown how TSI remotes deliver meaningful particle count data via the Log scaled 4-20mA analog outputs to building management systems and PLCs. This enables end users to manage potentially large variations of particle count information, meaning that critically important process data will not be missed, greatly assisting in root cause analysis. TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 4 91 11 87 64 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 CC-118 (4/21/2014 A4) 2014 TSI Incorporated Printed in U.S.A.