GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Similar documents
N6,6 Posidyne Membranes

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions

MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

InertSustainSwift C8

Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation

This method describes the identification of the following prohibited colorants in cosmetic products:

Laboratory filtration. Principles and chemical compatibility chart

stance et Helper Eppendorf Pipet Helper Chemical Resistance

The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

Chemical Compatibility of Filter Components

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

SOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Cation Exchange HPLC Columns

Shodex TM ODP2 HP series columns

Glove Selection Chart

Materials of Construction and Chemical Compatibility for Sensing and Control Products

8 Materials, Corrosion Resistance Tables

Halar ECTFE chemical resistance chart

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Cellufine Butyl Cellufine Phenyl

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LATEST TECHNOLOGY IN Safe handling & Recovery OF Solvents in Pharma Industry

Ferdowsi University of Mashhad

Alcohols, Phenols and Ethers

Optical Isomer Separation Columns and Packing Materials

An alcohol is a compound obtained by substituting a hydoxyl group ( OH) for an H atom on a carbon atom of a hydrocarbon group.

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

Aromatic Hydrocarbons

High Purity Chromasolv Solvents

Swell Sheet Chemical Resistance Guide

TAMMSFLEX SL / TAMMSFLEX NS

PEROXIDE-FORMING CHEMICALS

Safe Installation and Use of the NanoRam Immersion Probe

PRODUCT DATA SHEET PDS A88_E

CHEM 263 Oct 11, Lecture Outline 3: Alcohols, Ethers, Stereochemistry, Ketones, and Aldehydes. Ethanol

Dionex IonPac AS28-Fast-4µm column

High Performance Liquid Chromatography

High Performance Liquid Chromatography

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

gerflor.com.au Stain chemicals

Swell Sheet Chemical Resistance Guide

CHEM 261 Dec 4, 2017

Safe Operating Procedure

Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione

Chemistry 110. Bettelheim, Brown, Campbell & Farrell. Ninth Edition

Chemical Storage According to Compatibility

Eppendorf UVette. Instructions for use

Alltech Alltima HP Introduction

Hints for Strong Ion Exchange Resins

Peek Chemical Resistance

PRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

Lesmahagow High School

Egualen Sodium Granules

Amicon Ultra-15 10K Centrifugal Filter Devices

Headspace Technology for GC and GC/MS: Features, benefits & applications

A freely accessible HNS data base

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Appendix 5: table of chemical compatibility for tubing

PREVENTING HAZARDOUS WASTE FINES

BELZONA PRODUCT DATA G504 CHEMICAL RESISTANCE OF BELZONA 5892

Sizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request

Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Optimizing GPC Separations

ProPac WCX-10 Columns

LC and LC/MS Column Selection Flow Chart

Enzymatic Assay of CARBOXYPEPTIDASE P (EC )

How proteins separate on reverse-phase HPLC

3.0 Spiraltek Rolled Filters

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

groups I and II cations, amines, divalent transition metals

CHEMICAL RESISTANCE OF BELZONA 1523 FN10150

Safety Manual > Incompatible Chemicals Partial Listing

Desalting and Buffer Exchange with Corning Spin-X UFCentrifugal Concentrators

ALCOHOLS AND PHENOLS

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Gloves: choice and use

500 SERIES CHEMICAL RESISTANCE GUIDE

Preparation, analysis of samples in HPLC

TEPZZ 6ZA_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: C07D 401/06 ( )

1. Name the following compound. Use the IUPAC system and include the stereochemical designations.

Ondansetron Hydrochloride Tablets

Background on Solubility

Chemical Compatibility Guide Issue One

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES

Supporting Information

MEDROXYPROGESTERONE INJECTION

Partial Periodic Table

FUNDERMAX GMBH TEST REPORT

HPLC Sample Preparation

HAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Transcription:

syringe filters promises reproducible results from the filtration of organic and aqueous solutions in HPLC. Trace amount of samples containing impurities or contaminants can be easily removed, resulting in extending the lifetime of an HPLC analytical column. Usage Type Description and Ion-Chromato 4A 13A 25A 4A 13A 25A 13S 4P 13P 25P 4N 13N 4N 13N 4AI 13AI 25AI Composed of hydrophilic polyolefine membrane and polypropylene housing. Ideal for use in water and alcoholic solution targeted for sample preparation of protein analysis. This is a type that a chromatodisc and a syringe are combined. Composed of hydrophilic PTFE and polypropylene housing. Can be used without any pre-wet treatment for hydrophilics and hydrophobics. Acetonitrile 100% solution can be used. Solvents that can be used are alcohols, ethers, esters, ketones, hexanes. Autoclave sterilization is applicable. Composed of PTFE membrane and polypropylene housing. Excellent in solvent and chemical resistance. Therefore, it is ideal for use in organic solvents, strong acids, strong alkalis targeted for sample preparation of microanalysis. Autoclave sterilization is applicable. Composed of hydrophilic polyolefine membrane and polypropylene housing, which is treated by deionization. Ideal for use in sample preparation for ion chromatograph analysis. Type A Type P Type N

syringe filter for & samples Used for filtration of & samples Name 4P 13P 25P Fluorinated polymer membrane is used. & hydrophobic samples can be used without any pre-wetted treatment. Up to a 100% acetonitrile can be used. Ideal for filtration of alcohols, ethers, esters, ketones, and hexanes. polytetrafluoroethylene (PTFE) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7kgf/cm2 5kgf/cm2 6kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) 0.45 0.2 0.45 0.45 Cat. No. 5040-28540 5040-28551 5040-28541 5040-28542 syringe filter for samples Used for filtration of s Name 4A 13A 13S 25A Ideal for pretreatment of water and alcohol solution in HPLC and protein analysis.. membrane (Olefin polymer) Size 4mm 13mm 13mm 25mm Size 8ψ x 18 18ψ x 22 18ψ x 94 29ψ x 24 With a syringe Size 1mL 0.5 ~10mL 3~50mL Hold-UP Volume 10μL 30μL 30μL 100μL E.F.A. 0.07cm2 0.8cm2 0.8cm2 4.0cm2 M.A.O.P. 7kgf/cm2 5kgf/cm2 5kgf/cm2 6kgf/cm2 Ethelene oxide gas Pore Size (μm) 0.2 0.45 0.2 0.45 0.45 0.2 0.45 Cat. No. 5040-28500 5040-28510 5040-28501 5040-28511 5040-28513 5040-28502 5040-28512 Pcs./Box 100 100 50 100

syringe filter for samples Used for filtration of s Name 4N 13N Superior chemical compatibility. Ideal for filtration of solvents, strong acids and alkali solution. Usable as a air-venting filter PTFE Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas / Autoclave Pore Size (μm) 0.2 0.45 0.2 0.45 0.20 0.45 Cat. No. 5040-28503 5040-28530 5040-28504 5040-28531 5040-28505 5040-28532 syringe filter for Ion-Chromatography samples Used for filtration of Ion chromatography s Name 4AI 13AI 25AI Deionized hydrophilic membrane is used. Ideal for filtration of ion chromatography samples Deionized membrane (Olefin polymer) Size 4mm 13mm 25mm Size 8ψ x 18 18ψ x 22 29ψ x 24 Size 1mL 0.5 ~10mL 3~50mL M.A.O.P. 7 kgf/cm2 5 kgf/cm2 6 kgf/cm2 Ethylene oxide gas Pore Size 0.45μm 0.45μm 0.45μm Cat. No. 5040-28520 5040-28521 5040-28522

Chemical Resistance Information TYPE A : / Ion Chromatography O Enable TYPE P : / Enable but only for rapid use TYPE N : X Disable Chemical Name Chemical Description / Type A P N Acids Alkalis Alcohols Ethers Esters Glacial acetic acid Acetic acid 90% Acetic acid 30% O O Acetic acid 10% O O Hydrochloric acid Conc. X X X Hydrochloric acid 6N X O Sulfuric acid Conc. X X X Sulfuric acid 6N X O Nitric acid Conc. X X X Nitric acid 6N X O Ammonia 6N Ammonia 3N O O Potassium hydroxide 3N O O Sodium hydroxide 6N Sodium hydroxide 5N O O Sodium hydroxide 3N O O O Methanol O O O Ethanol O O O Propanol O O Isopropanol O O O Butanol O O O Amyl alcohol O O Ethylene glycol O O Propylene glycol O O Glycerin O O Ethyl ether O O O Isopropyl ether O O Dioxane X O O Tetrahydrofuran X O O Methyl acetate X O O Ethyl acetate X O O Isopropyl acetate X O Butyl acetate X O O

Ordering Information Usage Type Diameter (mm) Pore Size (um) Cat# QTY. 4A 4 0.2 5040-28500 100pcs 0.45 5040-28510 100pcs 13A 13 0.2 5040-28501 100pcs 0.45 5040-28511 100pcs 25A 25 0.2 5040-28502 100pcs 0.45 5040-28512 100pcs 13S 13 0.45 5040-28513 50pcs & 4P 4 0.45 5040-28540 100pcs 13P 13 0.2 5040-28551 100pcs 0.45 5040-28541 100pcs 25P 25 0.45 5040-28542 100pcs Ion-Chromato 4N 4 13N 13 25 4AI 4 13AI 13 25AI 25 0.2 5040-28503 100pcs 0.45 5040-28530 100pcs 0.2 5040-28504 100pcs 0.45 5040-28531 100pcs 0.2 5040-28505 100pcs 0.45 5040-28532 100pcs 0.2 5040-28506 100pcs 0.45 5040-28520 100pcs 0.2 5040-28507 100pcs 0.45 5040-28521 100pcs 0.2 5040-28508 100pcs 0.45 5040-28522 100pcs GL Sciences, Inc. Japan 22-1 Nishishinjuku 6-Chome Shinjuku-ku, Tokyo, 163-1130, Japan Phone: +81-3-5323-6620 FAX: +81-3-5323-6621 email: world@gls.co.jp GL Sciences, Inc. USA 4733 Torrance Blvd. Suite 255 Torrance, CA 90503 Phone: 310-265-4424 FAX: 310-265-4425 email: info@glsciencesinc.com International Distributors Visit our Website at http://www.glsciences.com/products/contact.html