Plasma parameter evolution in a periodically pulsed ICP

Similar documents
Electron Temperature Modification in Gas Discharge Plasma

DOE WEB SEMINAR,

Hong Young Chang Department of Physics, Korea Advanced Institute of Science and Technology (KAIST), Republic of Korea

Electron energy distribution function measurements and plasma parameters in inductively coupled argon plasma

Retarding Field Analyzer for Ion Energy Distribution Measurement Through a Radio-Frequency or Pulsed Biased Sheath

P. Diomede, D. J. Economou and V. M. Donnelly Plasma Processing Laboratory, University of Houston

Floating probe for electron temperature and ion density measurement applicable to processing plasmas

Feature-level Compensation & Control

Effect of Noble Gas. Plasma Processing Laboratory University of Houston. Acknowledgements: DoE Plasma Science Center and NSF

Diffusion during Plasma Formation

CHAPTER 8. SUMMARY AND OUTLOOK 90 Under the operational conditions used in the present work the translation temperatures can be obtained from the Dopp

Low-field helicon discharges

Electron Energy Distributions in a Radiofrequency Plasma. Expanded by Permanent Magnets

Equilibrium model for two low-pressure electronegative plasmas connected by a double layer

Physique des plasmas radiofréquence Pascal Chabert

Nonlinear effects in inductively coupled plasmas a

A Kinetic Theory of Planar Plasma Sheaths Surrounding Electron Emitting Surfaces

FINAL REPORT. DOE Grant DE-FG03-87ER13727

The distorting effect of the ion current on electron temperature measured by an electric probe

Plasma diagnostics of pulsed sputtering discharge

4 Modeling of a capacitive RF discharge

PIC-MCC simulations for complex plasmas

Angular anisotropy of electron energy distributions in inductively coupled plasmas

Two-dimensional simulation of a miniaturized inductively coupled plasma reactor

Measurement of electron energy distribution function in an argon/copper plasma for ionized physical vapor deposition

Plasma properties determined with induction loop probes in a planar inductively coupled plasma source

The low-field density peak in helicon discharges

Recombination and Decay of Plasma Produced by Washer Stacked Plasma Gun inside a Curved Vacuum Chamber

Multi-fluid Simulation Models for Inductively Coupled Plasma Sources

Simulation of Low Pressure Plasma Processing Reactors: Kinetics of Electrons and Neutrals

65 th GEC, October 22-26, 2012

Electron Density and Ion Flux in Diffusion Chamber of Low Pressure RF Helicon Reactor

Effects of cross field diffusion in a low pressure high density oxygen/silane plasma

Spatially resolved mass spectrometric sampling of inductively coupled plasmas using a movable sampling orifice

PIC-MCC/Fluid Hybrid Model for Low Pressure Capacitively Coupled O 2 Plasma

The Role of Secondary Electrons in Low Pressure RF Glow Discharge

Low Temperature Plasma Technology Laboratory

Control of Ion Energy Distributions on Plasma Electrodes

Plasmas rf haute densité Pascal Chabert LPTP, Ecole Polytechnique

MODELING AND SIMULATION OF LOW TEMPERATURE PLASMA DISCHARGES

Cross-Field Plasma Transport and Main Chamber Recycling in Diverted Plasmas on Alcator C-Mod

NARROW GAP ELECTRONEGATIVE CAPACITIVE DISCHARGES AND STOCHASTIC HEATING

Effect of Gas Flow Rate and Gas Composition in Ar/CH 4 Inductively Coupled Plasmas

Comparison of the B field dependency of plasma parameters of a weakly magnetized inductive and Helicon hydrogen discharge

Low Temperature Plasma Technology Laboratory

Plasma Diagnostics Introduction to Langmuir Probes

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Control of gas discharge plasma properties utilizing nonlocal electron energy distribution functions DOE-OFS Plasma Science Center

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

MODELING OF SEASONING OF REACTORS: EFFECTS OF ION ENERGY DISTRIBUTIONS TO CHAMBER WALLS*

Plasma Chemistry Study in an Inductively Coupled Dielectric Etcher

Physics and Modelling of a Negative Ion Source Prototype for the ITER Neutral Beam Injection

The Gaseous Electronic Conference GEC reference cell as a benchmark for understanding microelectronics processing plasmas*

ADVENTURES IN TWO-DIMENSIONAL PARTICLE-IN-CELL SIMULATIONS OF ELECTRONEGATIVE DISCHARGES

Experimental test of an expression for the decay of an autocorrelation function

ion flows and temperatures in a helicon plasma source

Model for noncollisional heating in inductively coupled plasma processing sources

1 EX/P7-35. Spectroscopic Studies on GLAST-III Varying the Inductance and Charging Voltage of Vertical Field Coils

Study of DC Cylindrical Magnetron by Langmuir Probe

EFFICIENT PLASMA PRODUCTION IN LOW BACKGROUND NEUTRAL PRESSURES WITH THE M2P2 PROTOTYPE

Plasma Chemistry and Kinetics in Low Pressure Discharges

Effect of wall charging on an oxygen plasma created in a helicon diffusion reactor used for silica deposition

Beams and magnetized plasmas

MWP MODELING AND SIMULATION OF ELECTROMAGNETIC EFFECTS IN CAPACITIVE DISCHARGES

CONSEQUENCES OF RADIATION TRAPPING ON ELECTRON ENERGY DISTRIBUTIONS IN LOW PRESSURE INDUCTIVELY COUPLED Hg/Ar DISCHARGES*

Increased Upstream Ionization Due to Spontaneous Formation of a Double Layer in an Expanding Plasma

NARROW GAP ELECTRONEGATIVE CAPACITIVE DISCHARGES AND STOCHASTIC HEATING

Experimental High Energy Physics & Plasma Etching

Anode double layer in magnetized radio frequency inductively coupled hydrogen plasma

Characteristics and classification of plasmas

Low Temperature Plasma Technology Laboratory

Nonlinear Diffusion in Magnetized Discharges. Francis F. Chen. Electrical Engineering Department

Driving frequency effects on the mode transition in capacitively coupled argon discharges

Langmuir Probes as a Diagnostic to Study Plasma Parameter Dependancies, and Ion Acoustic Wave Propogation

A global (volume averaged) model of a chlorine discharge

Dynamics of ion-ion plasmas under radio frequency bias

Measuring velocity of ion acoustic waves through plasma Hannah Saddler, Adam Egbert, and Warren Mardoum

Measurement of EEDF and Distribution of Primary Electron in a Bucket Ion Source

vacuum analysis plasma diagnostics surface science gas analysis

Frequency variation under constant power conditions in hydrogen radio frequency discharges

THE TOROIDAL HELICON EXPERIMENT AT IPR

Frequency dependent effects in helicon plasmas

Discharge equilibrium of a helicon plasma

Influence of vibrational kinetics in a low pressure capacitively coupled hydrogen discharge

Effect of electron energy distribution function on power deposition and plasma density in an inductively coupled discharge at very low pressures

Characterization of an Oxygen Plasma by Using a Langmuir Probe in an Inductively Coupled Plasma

arxiv:physics/ v1 [physics.plasm-ph] 5 Nov 2004

Nanopantography: A method for parallel writing of etched and deposited nanopatterns

EFFECT OF PRESSURE AND ELECTRODE SEPARATION ON PLASMA UNIFORMITY IN DUAL FREQUENCY CAPACITIVELY COUPLED PLASMA TOOLS *

Two-dimensional Fluid Simulation of an RF Capacitively Coupled Ar/H 2 Discharge

SCALING OF PLASMA SOURCES FOR O 2 ( 1 ) GENERATION FOR CHEMICAL OXYGEN-IODINE LASERS

PIC-MCC/Fluid Hybrid Model for Low Pressure Capacitively Coupled O 2 Plasma

Experimental investigation of double layers in expanding plasmas

Lee Chen, Merritt Funk, and Radha Sundararajan Tokyo Electron America, Austin, Texas 78741

PRINCIPLES OF PLASMA DISCHARGES AND MATERIALS PROCESSING

PIC/MCC Simulation of Radio Frequency Hollow Cathode Discharge in Nitrogen

Modelling of magnetic nozzle thrusters with application to ECR and Helicon thrusters

Extrel Application Note

Optical plasma emission spectroscopy of etching plasmas used in Si-based semiconductor processing

1 IC/P4-5. Spheromak Formation by Steady Inductive Helicity Injection

Transcription:

Plasma parameter evolution in a periodically pulsed ICP V. Godyak and B. Alexandrovich OSRAM SYLVANIA, 71 Cherry Hill Drive, Beverly, MA 01915, USA The electron energy probability function (EEPF) has been measured in inductively coupled plasma (ICP) operated in a periodically pulsed regime. Time resolved EEPF measurements were performed in the afterglow between pulses and basic plasma parameters (plasma density and effective electron temperature) were found as appropriate integrals of the measured EEPF. When operated at the same average rf power, the periodically pulsed ICP was found to have a significantly larger plasma density and lower electron temperature than when operated in a CW mode. 1. Introduction It has been known for a long time that a pulsed plasma has additional plasma parameter control over a steady state or CW operated discharge, which is limited by the plasma ionization and energy balance. In a steady state gas discharge at low gas pressure, particle balance requires the electron temperature T e to be a function of the product pd, where p is the gas pressure and d is the characteristic plasma dimension: T e = T e (pd). In addition, the electron energy balance defines the electron heating electric field, E, maintained at some fixed equilibrium level that depends on pd: E = E(pd). Both, T e and E are practically independent of the discharge power P d. The plasma conductivity that proportional to plasma density, n, is nearly proportional to the discharge current density J, so that E ~ (P d /n) 1/2 keeps constant. In a steady state discharge, plasma density is in equilibrium with discharge power, thus, increase in discharge power does not lead to increase in the electric field and electron temperature. Actually, due to various non-linear processes in the plasma particle balance and in EEPF formation, both E and T e slightly decrease with increasing discharge power. The origin of these non-linear processes is associated with rising plasma density. When plasma is energized pulse-wise, by RF bursts of duration T on, being much shorter than the time-off between the pulses T off, and T off is maintained shorter than the plasma diffusion time, T d, (T on << T off << T d ), the plasma density does not have time to attain equilibrium, and, therefore, the electric field and electron temperature can exceed their equilibrium levels. Since the ionization rate is a sharply increasing function of electron temperature, the greater electron temperature during the pulse causes intense ionization that compensates plasma particle loss due to diffusion to the wall in the afterglow stage between pulses. With the absence of a heating electric field in the afterglow stage, electrons cool down mainly due to electron diffusion to the chamber wall; the process known as diffusion cooling [1]. Interest in pulsed operation of rf plasmas was recently revitalized in the hope of achieving more flexibility in plasma parameter control in the plasma processing reactors [2-4]. A detailed study of the EEPF in ICP afterglows was performed in Ref. 3 where diffusion cooling was proven to be the major electron cooling process in argon ICP afterglow at 15 and 70 mtorr. Results of an experimental study of the plasma parameter evolution in periodically pulsed ICP are presented in this paper. A significant enhancement in the plasma density and reduction in electron temperature are demonstrated for a periodically pulsed mode when compared with a CW mode. 2. Experimental set-up Measurements were performed in afterglow, during off-cycle in the ICP sustained in a metal chamber having the diameter 10 cm and length 12 cm. The plasma was energized by short bursts of rf power at 4 MHz using the internal helical antenna (2.2 cm diameter and 5 cm length having 12 turns) placed in the mid-plane along the chamber axis. The discharge power delivered to the

plasma was calculated as the difference between the total power delivered to the antenna and the power dissipated in the antenna itself. Probe measurements were performed at the discharge mid-plane, at radial position r = 5 cm, near the peak plasma density. Gas flow through the chamber- insuring gas purity - was controlled by a needle micro-valve at the gas inlet and by a diaphragm valve at the chamber downstream. This vacuum system allowed maintaining argon pressure within the chamber in the range from 3 to 300 mtorr. The time resolved second derivative of the probe characteristic that is proportional to the electron energy probability function (EEPF) was measured with our station for fast probe measurement [5,6]. The procedure for acquiring the probe characteristic in periodically pulsed plasma includes formation of the probe bias voltage, that is updated in incremental steps on each new pulse, and continuous acquisition of the probe current waveform during the pulse period. Both, voltage generation and current acquisition are triggered by the pulse front. The data block, obtained during the period of one pulse, is the time-varying current at the given bias voltage. The number of samples acquired during the pulse period equals the sampling frequency to the pulse frequency ratio. Each new data block, obtained during a successive pulse, presents time-varying current at the updated level of the bias voltage. Consequently, the data that have the same index in each block (corresponding to the same instant within the period) are sorted together creating a single I-V characteristic for the given moment. Each I-V is processed separately to obtain an instant EEDF. The probe station also incorporates feedback from a floating reference probe to reduce plasmagenerated noise and compensate for voltage drop across the chamber wall sheath due to current collected by the probe. The measurement-acquisition system used here provides time resolution of 0.5 s. Acquisition of a hundred time-resolved EEDF s, each averaged over 100 samples takes less then 1 minute when the plasma is pulsed at 1 khz rate. The enormous reduction in the processing time (1 minute compared to 5 hours in Ref. 3) not only saves time, but also reduces EEPF measurement distortions caused by plasma drift and by any changes in the work function of the probe surface during a slow scan of the probe voltage. 3. Experimental results and discussion The values of T e in the CW mode and the time evolution of T e in a 100 W ICP afterglow (offcycle) for different argon pressures are shown in Fig. 1. These data were obtained at 50% duty cycle, with the on-cycle long enough (1 ms) to reach steady state, then followed by the afterglow. Fig. 1 shows that electron cooling is faster for lower argon pressure, suggesting that the diffusion cooling is the main mechanism of the electron energy loss in the afterglow [3], even at the highest gas pressure (300 mtorr). In the late afterglow stage, T e reaches very low values (up to 0.05 ev) that are close to the argon gas temperature. The minimum value of the electron temperature, found in the experiment, is probably limited by the resolution of EEPF measurement of our experimental apparatus.

electrron temperature (ev) 1 0.1 Ar, CW 100 W p Te (mt) (ev) 3.0 6.5 10 4.2 30 3.1 100 2.1 300 1.5 300 100 3 mt 10 30 1 10 100 1000 time ( s) Fig. 1. T e in the CW mode (table) and the EEPF in the afterglow Electron temperature cooling occurs more rapidly at lower gas pressures, as plasma loss to the wall transits from collisional ambipolar diffusion at high pressure to that controlled by the ion inertia in the Tonks-Langmuir regime at low pressure. The large span of electron temperature change during the afterglow suggests that the electron temperature can be controlled in the periodically- pulsed discharge by varying off-cycle time. An example of such electron temperature control is demonstrated in Figs. 2 and 3 where time evolution of the measured EEPF, calculated values of the effective electron temperature, T e, and the plasma density, n, are given for a 30 mtorr ICP at the average discharge power of 50 W (~ 550W peak). The measurements were made during the afterglow stage of a periodically pulsed ICP with on-time, T on = 2 s, and off-time, T off = 20 s. For comparison, the EEPF and plasma parameters for the same ICP in a CW mode with the same gas pressure and discharge power are given in Fig. 4. Figs. 2, 3 and 4, show that the electron temperature in the afterglow stage is essentially lower than that in CW mode, and is a falling function of elapsed time.

10 12 Ar, 30 mt, 50 W; off cycle T = 2 s on T = 20 s off eepf (ev -3/2 cm -3 ) 10 11 10 10 10 9 t = 2.8 s 3.6 4.4 6.8 9.2 12.4 18.8 0 5 10 15 electron energy (ev) Fig. 2. The EEPF evolution in the afterglow stage. EEPFs are shown in order from left to right as the elapsed time, t. The shift in the EEPF position along the energy axis corresponds to the plasma potential shift, reference to the plasma potential at t = 2.8 s. 8 Ar, 30 mt, 50 W; off cycle 3 plasma density 10 11 (cm -3 ) 6 4 2 T on = 2 ms, T off = 20 ms 2 1 electron temperature (ev) 0 0 5 10 15 20 time ( s) 0 Fig. 3. Plasma parameters in the afterglow stage. By the end of the afterglow period, the electron temperature is an order of magnitude less than that in the CW mode. Due to absence of the electric field and reduced electron temperature, the EEPF in the late afterglow stage is Maxwellian.

10 10 Ar, 30 mt, 50 W; CW eepf (ev -3/2 cm -3 ) 10 9 10 8 T eff = 4.4 ev n = 1.5 10 11 cm -3 10 7 0 5 10 15 20 25 electron energy (ev) Fig. 4. EEPF and plasma parameters in the CW mode. The lowest electron temperature in the afterglow stage is controlled by the afterglow duration. Thus, the time-averaged electron temperature can be controlled varying T off. The reduction in the time-averaged electron temperature in the periodically pulsed discharge is accompanied by the presence of high temperature electrons during on-cycle. Their effective electron temperature, T eff, is expected to be higher than T eff for the CW mode, because the electric field during on-cycle is higher than for CW. Obtaining EEPF during on-cycle in present experiment was not possible, because the characteristic rise time of plasma density and, to an even larger extent, the rise time of the electron temperature were comparable to or less than the time resolution of our measurement apparatus. Due to excess of high energy electrons during on-cycle and a their fast cooling during off-cycle (afterglow), the time averaged EEPF in a periodically pulsed discharge is expected to have a twotemperature structure, like the bi-maxwellian EEPF found in a low pressure capacitive rf discharge [7]. Due to near-exponential dependence of the ionization rate on electron temperature (electron mean energy), only a moderate increase in T eff during the pulse on-cycle could be anticipated comparing to T eff in a CW mode. Therefore, for a typical case of periodically pulsed plasma (T off >> T on ), the effective electron temperature, averaged over the period (T on + T off ), is always lower than T eff in CW mode. Comparing electron temperatures and plasma densities for CW (Fig. 4) and periodically-pulsed ICP (Fig. 3), one can see that in the case of periodicallypulsed plasma the time averaged electron temperature, <T e > 1 ev, is considerably less, while the averaged plasma density <n> 5 10 11 cm -3 is considerably higher than those in CW mode. The reason for such significant difference in the plasma density is the intense ionization (plasma production) during on-cycle by the overheated electrons, and reduction (due to fast electron

cooling) of plasma diffusion to the wall in the afterglow stage. 4. References [1] M. A. Biondi, Phys. Rev. 93, (1954). [2] X. Tang and D. Manos, Plasma Source Sci. Technol. 8, 594 (1999). [3] A. Mareska, K. Orlov and U. Kortshagen, Phys. Rev. E 60, 056405 (2002). [4] S. Voronin, M. Alexander and J. W. Bradley, Meas, Sci. Technol. 15, 2375 (2004). [5] V. Godyak, R. Piejak and B. Alexandrovich, Plasma Source Sci. Technol. 11, 525 (2002). [6] B. Alexandrovich, V. Godyak and G. Lister, Proceedings of the 10 th International Symposium on the Science and Technology of Light Sources, p. 283, editor. G. Zissis (Toulouse, France, July 2004). [7] V. Godyak and R. Piejak, Phys. Rev. Lett. 65, 996 (1990).