GENERAL PHARMACOPOEIA MONOGRAPH

Similar documents
Annex 2 Formaldehyde

GENERAL PHARMACOPOEIA MONOGRAPH

CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

EXPT. 8 IODOMETRIC DETERMINATION OF AVAILABLE CHLORINE IN A SAMPLE OF BLEACHING POWDER

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

CIE Chemistry A-Level Practicals for Papers 3 and 5

Dehydrated Alcohol. » Dehydrated Alcohol contains not less than 99.2 percent, Pharmacopeial Forum Vol. 30(5) [Sept. Oct. 2004] HARMONIZATION 1847

National standard of People s Republic of China

INTERNATIONAL OLIVE COUNCIL

Exercise 6: Determination of Hardness of Water

Investigating Transition Metal Complexes

Determination of Reducing Sugar Content: Clinitest, Benedict s Solution and the Rebelein Titration

Suggested answers to in-text activities and unit-end exercises. Topic 16 Unit 55

Sodium Chloride - Analytical Standard

Synthesis and Analysis of a Coordination Compound

Volumetric Analysis Acids & Bases HL

Per Examiner s use only

Standardization of Hydrochloric Acid by Anhydrous Sodium Carbonate

GE 6163 CHEMISTRY LAB MANUAL

not to be republished NCERT YOU are already aware that a substance is analysed to establish its qualitative TITRIMETRIC ANALYSIS UNIT-6

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

$ % K st. K D [ I 2 ] Aqueous. [ I 2 ] Hexane. % Aqueous

Advanced Subsidiary Unit 3B: Chemistry Laboratory Skills I Alternative

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

for free kcse past papers visit:

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

Set 4 Marking Scheme: Acid Bases & Salts 2010

Concentration of Solutions

General Information 1

NAME INDEX NUMBER CANDIDATE SIGNATURE DATE.. 233/2/ CHEMISTRY PAPER 3 (PRACTICALS) JULY/AUGUST ¼ HOURS

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Zinc electrode. 1M zinc sulphate solution

LC-Learn. Leaving Cert Chemistry Notes Higher Level Volumetric Analysis

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. SPECIFICATION FOR BASIC CHROMIUM SULPHATE (FOR TANNING) (First revision of IS 6301) ICS:

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Practical 1 Procedure Iron by Titrimetry

Volumetric Analysis: Redox

KAKAMEGA NORTH SUBCOUNTY JOINT EXAMINATIONS KCSE TRIAL 2018

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w

Dharmapuri LAB MANUAL. Regulation : 2013 Branch. : B.E. All Branches GE6163-CHEMISTRY LABORATORY - I E NG

CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education


Partner: Judy 29 March Analysis of a Commercial Bleach

Part of the practical procedure is given below.

BRIEFING. Pharmacopeial Discussion Group Sign Off Document Attributes EP JP USP Definition Loss on drying Readily carbonizable substances

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level CHEMISTRY 5070/03

Section B: Some Essential Background Chemistry

4.2. VOLUMETRIC ANALYSIS PRIMARY STANDARDS FOR VOLUMETRIC SOLUTIONS VOLUMETRIC SOLUTIONS

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03

EXPERIMENTS. Testing products of combustion: Reducing Copper(III) Oxide to Copper. Page 4

Directed by Ph. Sadeel Shanshal

(KENYA CERTIFICATE OF SECONDARY EDUCATION) SCHOOL. DATE..

She carries out two experiments.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

9. Determination of the solubility product of KIO 4 and an investigation of the common ion effect Student Sheet

Mole Concept 5.319% = = g sample =

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

MAHESH TUTORIALS I.C.S.E.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

(a) (i) Explain what is meant by the terms transition element, complex ion and ligand,

Chemical Analysis. Student Guide. National 5 Chemistry

Chemistry Determination of Mixed Acids

Cambridge International Examinations Cambridge Ordinary Level


Cambridge International Examinations Cambridge Ordinary Level

For the element X in the ionic compound MX, explain the meaning of the term oxidation state.

STUDYING CHEMICAL REACTIONS BY TITRATION ANALYSIS

MARAKWET WEST DISTRICT 233/1 CHEMISTRY PAPER 1 JULY/AUGUST 2015 TIME: 2 HOURS

Form 4 Chapter 7: Acid and Bases

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level

Volumetric Analysis: Acids & Bases OL


LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

4.4. Revision Checklist: Chemical Changes

TRANS-NZOIA COUNTY JOINT EVALUATION EXAMINATION-2014 Kenya Certificate of Secondary Education

CHEMISTRY 2815/06. Transition Elements. OXFORD CAMBRIDGE AND RSA EXAMINATIONS Advanced GCE

Cambridge International Examinations Cambridge Ordinary Level

Soil Quality Monitoring in Estuarine Ecosystem. Sachin N Hegde Center for Ecological Science Indian Institute of Science

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

1. This question is about Group 7 of the Periodic Table - the halogens. The standard electrode potentials for these elements are given below.

FORM TWO CHEMISTRY END TERM EXAMINATIONS MARCH/APRIL 2016 TIME:2HOURS NAME.ADM.NO:.

Practical Examination 2 (Part B Practical Test)

Set 1 Structure of the atoms & Chemical Equation Perfect Score F Matter is anything that. and has.

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

CHEMISTRY PAPER 2 (PRACTICAL)

Cu-Creatinine- Metol system

AIM To verify Beer - Lambert s law and to determine the dissociation constant (Ka) of methyl red, Spectrophotometrically.

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education CHEMISTRY

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Techniques for Volumetric Analysis

1.6 Equilibria All reversible reactions reach an dynamic equilibrium state.

ANNEXURE - I MEDIA AND REAGENTS

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certifi cate of Education Advanced Subsidiary Level and Advanced Level

Write an overall equation for the first stage in the rusting of iron.

Transcription:

MINISTRY OF HEALTH OF THE RUSSIAN FEDERATION GENERAL PHARMACOPOEIA MONOGRAPH Colour intensity of liquids GPM.1.2.1.0006.15 Replaces the State Pharmacopoeia of the Russian Federation XII, Part 1 Monograph, GPM 42-0050-07 Colour intensity is determined by visual examination, using one of the methods described below, by comparison with an appropriate reference standard. This Monograph includes medicinal product quality control methods for the parameters «colour intensity» and «solution colour intensity». Colour intensity is a conditional quantitative characteristic used for slightly coloured liquids. Colour is an observer s perception or subjective reaction to an objective stimulus that is an energy radiated in the visible spectral region and spanning the wavelength range from 400 nm to 700 nm. The colour intensities of two solutions coincide (for a certain source of light) if their absorbance and reflection spectra are identical and the observer sees no difference between them. Achromatism or no colour means the absence of absorption in the visible spectral region for the tested solution. One or two of the methods described in the Monograph should be used for visual examination of the colour of a liquid depending on its intensity in the brown, yellow, and red colour regions. A colourless liquid is a liquid whose colour does not differ from that of water (or of the respective solvent in the case of solutions) or whose the colour intensity does not exceed that of Reference Standard B 9. The colour intensity of a liquid is usually compared with that of reference

standards (В, BY, Y, GY, R) 1-3 using Method 1; Method 2 is utilized when reference standards В 4-9, (BY, Y, GY, R) 4-7 are used. Method 1 Tests are carried out in the same test tubes made of colourless, transparent, neutral glass, with an internal diameter of approximately 12 mm, using equal volumes 2.0 ml of the tested liquid and water, or the solvent, or the reference standard described in the Monograph. Colour comparison is performed in scattered daylight, by visual examination in the horizontal plane (perpendicular to the test tube axis), against a matted white background. Method 2 Tests are carried out in the same test tubes made of colourless, transparent, neutral glass, with an internal diameter from 15 mm to 25 mm, using equal, 40 mm thick layers of the tested liquid and water, or the solvent, or the reference standard described in the Monograph. Colour comparison is performed in scattered daylight, by visual examination, from top to bottom along the vertical axis of the test tube, against a matted white background. Preparation of the stock solutions Yellow solution. Transfer 46.0 g (accurately measured weight) of iron (III) chloride (FeCl 3 6 Н 2 O; M. w. 270.30) into a 1000 ml volumetric flask, dissolve in 900 ml of a mixture consisting of 25 ml of concentrated hydrochloric acid and 975 ml of water, bring the volume of the solution in the volumetric flask to the mark with the same mixture, and stir. Determine the content of iron (III) chloride in 1 ml of this solution. The iron (III) chloride solution volume is then diluted with the same mixture so that the content of iron (III) chloride is 45.0 mg per millilitre. This solution should be stored away from light. Quantification: Transfer 10.0 ml of the iron (III) chloride solution into a 250 ml conical volumetric flask equipped with a ground-in stopper, add 15 ml of water, 5 ml of concentrated hydrochloric acid, and 4 g of potassium iodide, stir, close the flask with the stopper and leave it to stand for 15 minutes in a dark place; 2

after that add 100 ml of water. Titrate the released iodine with 0.1 Μ sodium thiosulphate solution, adding 0.5 ml of 1 % starch solution as an indicator towards the end of titration. Simultaneously perform a control experiment. 1 ml of 0.1 Μ sodium thiosulphate solution corresponds to 27.03 mg of iron (III) chloride (FeCl 3 6 Н 2 O). Red solution. Transfer 60.0 g (accurately measured weight) of triturated cobalt chloride (СоСl 2 6 Н 2 O; M. w. 237.93) into a 100 ml volumetric flask, dissolve in 900 ml of a mixture consisting of 25 ml of concentrated hydrochloric acid and 975 ml of water, bring the volume of the solution to the mark with the same mixture, and stir. Determine the content of cobalt chloride in 1 ml of this solution. The cobalt chloride solution volume is then diluted with the same mixture so that the content of cobalt chloride is 59.5 mg per millilitre. Quantification. Transfer 5.0 ml of the cobalt chloride solution into a 250 ml conical volumetric flask equipped with a ground-in stopper, add 5 ml of 3 % hydrogen peroxide solution and 30 ml of 10 % sodium hydroxide solution. Boil this mixture with a reverse refrigerator for 10 minutes, then cool it down to room temperature, and add 60 ml of 1 M sulphuric acid solution and 2 g of potassium iodide. Close the volumetric flask and dissolve the sediment while stirring carefully. Titrate the released iodine with 0.1 Μ sodium thiosulphate solution until a pale pink colour is acquired, using 0.5 ml of 1 % starch solution as an indicator towards the end of titration. Perform a control experiment at the same time. 1 ml of 0.1 Μ sodium thiosulphate solution corresponds to 23.79 mg of cobalt chloride (СоС1 2 6 Н 2 О). Blue solution. Transfer 63.0 g (accurately measured weight) of copper (II) sulphate (CuS0 4 5 Н 2 O; M. w, 249.68) into a 1000 ml volumetric flask, dissolve in 900 ml of a mixture consisting of 25 ml of concentrated hydrochloric acid and 975 ml of water, in a 1000 ml volumetric flask, then bring the volume of the solution in the volumetric flask to the mark with the same mixture and stir. 3

Determine the content of copper (II) sulphate in 1 ml of this solution. The copper (II) sulphate solution volume is then diluted with the same mixture so that the content of copper (II) sulphate is 62.4 mg per millilitre. Quantification. Transfer 10.0 ml of the copper (II) sulphate solution into a 250 ml conical volumetric flask equipped with a ground-in glass stopper, add 50 ml of water, 12 ml of 2 M acetic acid solution, and 3 g of potassium iodide, and stir this mixture. Titrate the released iodine with 0.1 Μ sodium thiosulphate solution until a pale brown colour is acquired, using 0.5 ml of 1 % starch solution as an indicator towards the end of titration. Perform a control experiment at the same time. 1 ml of 0.1 Μ sodium thiosulphate solution corresponds to 24.97 mg of copper (II) sulphate (CuSO 4 5Н 2 O). Preparation of the standard solutions The standard solutions are obtained by mixing the stock solutions of iron (III) chloride, cobalt chloride, and copper (II) sulphate with solution, measuring them with a calibrated pipette or burette within the accuracy of up to 0.02 ml (Table 1). Table 1 Standard solutions Standard solutions Yellow stock Red stock Blue stock 1 % hydrochloric acid В (brown) 30.0 30.0 24.0 16.0 BY (brownish yellow) 24.0 10.0 4.0 62.0 Υ (yellow) 24.0 6.0 0 70.0 GY (greenish yellow) 96.0 2.0 2.0 0 R (red ) 10.0 20.0 0 70.0 The prepared stock and standard solutions should be transferred into dry stoppered flasks and stored at (20±3) С in a place protected from direct sunlight. The shelf-life of the stock and standard solutions is 1 year. Before use, one should make sure that the stored stock and standard solutions contain no feculence, sediment, or flocculi. If any of these are present, such solution should be replaced with a freshly prepared one. 4

Preparation of the reference standards The reference standards are prepared from five standard solutions by diluting them with solution. Measurement of the stock and standard solutions for scale preparation is done using a calibration pipette or burette within the accuracy of 0.02 ml. The colour intensity reference standards for liquids used in Method I should be stored in ampoules made of colourless, transparent, neutral glass, with an external diameter of 12 mm, away from light, for 1 year. The colour intensity reference standards for liquids used in Method II should be prepared from respective standard solutions immediately before use. The quantities of the components used for the preparation of colour intensity reference standards are presented in Tables 2-6. Table 2 Brown colour reference standards (Scale В) Scale В reference standards Standard solution В, ml В 1 75.0 25.0 В 2 50.0 50.0 В 3 37.5 62.5 В 4 25.0 75.0 В 5 12.5 87.5 В 6 5.0 95.0 В 7 2.5 97.5 В 8 1.5 98.5 В 9 1.0 99.0 Table 3 - Brown-yellow colour reference standards (Scale ВY) Scale BY reference standards Standard solution BY, ml BY 1 100.0 0.0 BY 2 75.0 25.0 ВY 3 50.0 50.0 BY 4 25.0 75.0 BY 5 12.5 87.5 ВY 6 5.0 95.0 ВY 7 2.5 97.5 Table 4 Yellow colour reference standards (Scale Y) 5

Scale Y reference standards Standard solution Y, ml Y 1 100.0 0.0 Y 2 75.0 25.0 Y 3 50.0 50.0 Y 4 25.0 75.0 Y 5 12.5 87.5 Y 6 5.0 95.0 Y 7 2.5 97.5 Table 5 - Greenish-yellow colour reference standards (Scale GY) Scale GY reference standards Standard solution GY, ml GY 1 25.0 75.0 GY 2 15.0 85.0 GY 3 8.5 91.5 GY 4 5.0 95.0 GY 5 3.0 97.0 GY 6 1.5 98.5 GY 7 0.75 99.25 Table 6 - Red colour reference standards (Scale R) Scale R reference standards Standard solution R, ml R 1 100.0 0.0 R 2 75.0 25.0 R 3 50.0 50.0 R 4 37.5 62.5 R 5 25.0 75.0 R 6 12.5 87.5 R 7 5.0 95.00 The colour intensity of the tested solution should not exceed the colour intensity of the respective reference standard. The colour of the tested sample should be as much the same as the colour of the respective reference standard as possible. When comparing the colour of the tested solution versus a reference standard, the letter of the scale should be specified along with the reference standard used. For instance, the colour intensity of the solution should not exceed that of Reference Standard В 7. 6

Other reference standards may be used if necessary; they should be prepared by mixing stock solutions of different colour scales; their exact volumes should be specified that should be used to ensure the right colour close to the colour of the tested solution, if this is required by the Pharmacopoeia Monograph. Spectrophotometry may be used the evaluate the colour of a liquid, if this is envisaged by the Pharmacopoeia Monograph; the following should be specified: the wavelength at which the absorbance maximum is observed in the visible spectral region, the pathlength of the cuvette, and the optical density value with the acceptable deviation. 7