Bureau International des Poids et Mesures

Similar documents
Comparison of the standards of air kerma of the GUM and the BIPM for 60Co 'Y rays

Comparison of the standards of air kerma of the BNM-LPRI and the BIPM for 137CS y rays

Bureau International des Poids et Mesures

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation

Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays

Bureau International des Poids et Mesures

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60 Co gamma radiation

Comparisons of the standards for air kerma of the GUM and the BIPM for 60 Co and 137 Cs gamma radiation

Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the METAS, Switzerland and the BIPM in 60 Co gamma radiation

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays

Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co γ rays

Air Kerma Primary Standard: Experimental and. Simulation Studies on Cs-137. J. Cardoso, L. Santos, C. Oliveira

Abstract An indirect comparison of the standards for reference air kerma rate for

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Comparison of the standards for absorbed dose to water of the VSL and the BIPM for 60 Co gamma rays

KCDB-Identifiers: EURAMET.RI(I)-K1.2 / EURAMET.RI(I)-K4.2 / EURAMET.RI(I)-K5.1. Pilot laboratory: BEV (AT) Andreas Steurer 1), Wilhelm Tiefenboeck

Determination of absorbed dose to water for 60Co by the scaling theorem. M. Boutillon and A.-M. Perroche (1)

Comparisons between IRD and BIPM exposure and air-kerma standards. for cobalt-60 gamma rays. by C.E. de Almeida* and M.-T. Niatel

BIPM Key Comparison BIPM.RI(I)-K6 PROTOCOL 3.0 CCRI(I) 6 November 2017

PRELIMINARY CHARACTERIZATION OF THE NIS FREE-AIR CHAMBER STANDARD AT THE BIPM

First international comparison of primary absorbed dose to water standards in the medium-energy X-ray range

Comparison of national air kerma standards for ISO 4037 narrow spectrum series in the range 30 kv to 300 kv

Referensdosimetri. Crister Ceberg Medical Radiation Physics Lund University Sweden

M [scale units/s] of the system

Investigation of the standard temperature- pressure correction factor at low x-ray energies

C. Michotte*, G. Ratel* and S. Courte*, T. Dziel #, A. Listkowska #, I. Csete, K. Rózsa, L. Szücs, A. Zsinka, C. Fréchou**, C. Bobin**, S.

4.1b - Cavity Theory Lecture 2 Peter R Al mond 2011 Overview of Lecture Exposure (W/e)air Exposure Exposure and and and Air Air Kerma

G. Ratel*, C. Michotte*, Y. Hino** *BIPM and **NMIJ, Japan

The metrology of radioactivity. C. Michotte, BIPM

RECOMBINATION PARAMETERS OF SOME FABRICATED IONIZATION CHAMBERS

Activity measurements of the radionuclide 153 Sm for the ANSTO, Australia in the ongoing comparison BIPM.RI(II)-K1.Sm-153

ABSORBED DOSE BEAM QUALITY FACTORS FOR CYLINDRICAL ION CHAMBERS: EXPERIMENTAL DETERMINATION AT 6 AND 15 MV PHOTON BEAMS

Ionizing Radiation Dosimetry and Medical Physics

Ionizing Radiation Metrology at NMIJ/AIST and ENEA-INMRI

C. Michotte 1, G. Ratel 1, S. Courte 1, Y. Nedjadi 2, C. Bailat 2, L. Johansson 3, Y. Hino 4. Abstract

Comments on ICRU Report 64: Dosimetry of High-Energy Photon Beams based on Standards of Absorbed Dose to Water

G. Ratel 1, C. Michotte 1, D. Kryeziu 1, M. Moune 2, A. Iwahara 3. Abstract

Activity measurements of the radionuclide 111 In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

APMP key comparison for the measurement of air kerma for 60 Co (APMP.RI(I)-K1.1)

Work Programme. of the International Bureau of Weights and Measures. for the four years Comité international des poids et mesures

PRIMARY STANDARDS of AIR KERMA for 60 CO and X-RAYS & ABSORBED DOSE in PHOTON and ELECTRON BEAMS. Malcolm McEwen

Bureau International des Poids et Mesures

BIPM.RI(II)-K1.Am-241, CCRI(II)-K2.Am-241, and COOMET.RI(II)-K2.Am.241

Metrological traceability and specific needs in: - IR measurement for radiation protection (RP) - IR measurement for radiotherapy (RT)

A Correction Factor for Effects of Scattered X-rays at Calibration of Ionization Chambers in Low Energy X-ray Standard Fields

H Bjerke 1, J Plagnard 2, J-M Bordy 2, A Kosunen 3, J Huikari 3, L Persson 4, and P O Hetland 1

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Evaluation of Correction Factors Applied in Photon Calibration of NIS TE Neutron Ionization Chambers

G. Ratel 1, C. Michotte 1, M. Sahagia 2, A. Yunoki 3. Abstract

Comparison of air kerma measurements for tungsten anode based mammography x-ray beam qualities (EURAMET.RI(I)-S4.1)

Progress Report on Radiation Dosimetry Standards at NMIJ/AIST and Photon Energy Spectra Measured in Fukushima

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

Determination of the Specific Heat Capacity of Graphite Using Absolute and Differential Methods Susanne Picard David Burns Philippe Roger BIPM

Chapiter VII: Ionization chamber

Final Report August 2010

Bureau International des Poids et Mesures (BIPM),

Code of Practice for the Absorbed Dose Determination in High Energy Photon and Electron Beams

Study of the influence of phantom material and size on the calibration of ionization chambers in terms of absorbed dose to water

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

Radiation Dosimetry. Electron interactions with matter. Important processes in radiotherapy. Contents. Alun Beddoe

Draft protocol of APMP.RI(I)-K8 Reference air kerma rate for HDR Ir-192 brachytherapy sources

FINAL REPORT. European co-operation for Accreditation (EA) Interlaboratory Comparison IR3: Calibration of a Radiation Protection Dosimeter

Final report EURAMET project 813 1/46

Chapter V: Cavity theories

INTERNATIONAL COMPARISON OF WATER TRIPLE POINT CELLS LEADING TO A MORE PRECISE DEFINITION OF THE KELVIN

Calibration of Radioprotection Instruments and Calibrated Irradiation: Characterization of Gamma Beam of 137 Cs and 60 Co

Summary of the ICRM Life Sciences Working Group Meeting

General characteristics of radiation dosimeters

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

DRAFT B, Final Report on CIPM key comparison of 1 kg standards in stainless steel (CCM.M-K1)

Design, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors

8/2/2012. Larry DeWerd has a partial interest in Standard Imaging

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

Air kerma rate measurements from a miniature x-ray source using free-air ionization chambers

High-Energy Photon Beam Therapy Dosimetry with Ionisation Chambers

National Physical Laboratory (NPL), UK

APMP supplementary comparison of absorbed dose rate in tissue for beta radiation

Updating reference dosimetry a decade after TG-51

TA3 Dosimetry and Instrumentation EVALUATION OF UNCERTAINTIES IN THE CALIBRATION OF RADIATION SURVEY METER POTIENS, MPA 1, SANTOS, GP 1

Principles of applied dosimetry - illustrated by ionometry. Lesson FYSKJM4710 Eirik Malinen

BUREAU INTERNATIONAL DES POIDS ET MESURES

Measurement modelling of the International Reference System (SIR) for gamma emitting radionuclides

Chapter 9: Calibration of Photon and Electron Beams

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

Monte Carlo simulations as a tool for the development of a new reference ionisation chamber

Monte Carlo modeling of an electronic brachytherapy source using MCNP5 and EGSnrc

Comparison for Air Kerma from Radiation Protection Gamma-ray Beams with Brazilian Network /2017

CALIBRATION OF DOSEMETERS USED IN MAMMOGRAPHY WITH DIFFERENT X RAY QUALITIES: EUROMET PROJECT NO. 526

C. Michotte, G. Ratel, S. Courte and L. Joseph 1 BIPM, Sèvres and 1 Bhabha Atomic Research Centre (BARC), India

Bureau International des Poids et Mesures (BIPM), Sèvres. National Institute of Standards and Technology (NIST), USA. Becquerel (LNE-LNHB), France

Date h UTC APR 29 MAY 4 MAY 9 MAY 14 MAY 19 MAY 24 MAY 29 Uncertainty/ns Notes MJD u A

*BIPM, # CNEA, BARC, $ NRC, **NIM. Abstract

Activity measurements of the radionuclide 99m Tc for the NIST, USA in the ongoing comparison BIPM.RI(II)-K4.Tc-99m. C. Michotte 1, R.

Mass determination of 1 kg silicon spheres for Avogadro project

Use of a radioactive check device for redundancy check of ionization chambers

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the PTB, Germany and the BIPM in low-energy x-rays

Calorimetry for Absorbed-dose Measurements at BNM-LNHB

Transcription:

Rapport BIPM 02/01 Bureau International des Poids et Mesures Comparison of the standards of air kerma of the Yugoslavia and the BIPM for 60 Co γ rays by P.J. Allisy-Roberts, D.T. Burns, C Kessler BIPM and V. Spasić-Jokić January 2002 Pavillon de Breteuil, F-92312 SEVRES Cedex

Comparison of the standards of air kerma of the Yugoslavia and the BIPM for 60 Co γ rays by P.J. Allisy-Roberts*, D.T. Burns*, C Kessler # and V. Spasić-Jokić** *Bureau International des Poids et Mesures, F-92312 Sèvres Cedex # on secondment from the Centro Regional de Referencia para Dosimetría, Buenos Aries, Argentina **Savezni Zavod za Mere i Dragocene Metale, Belgrade, Yugoslavia Abstract A comparison of the standards of air kerma of the Savezni Zavod za Mere i Dragocene Metale () and of the Bureau International des Poids et Mesures (BIPM) has been carried out in 60 Co radiation. It shows that the and BIPM standards differ by 0.79 % with a relative standard uncertainty of 1.8 10 3. This result is compatible with the previous comparison of 1991 when the changes in the corrections for the wall effect and for axial non-uniformity of the standard are taken into account. 1. Introduction A comparison of the standards of air kerma of the Savezni Zavod za Mere i Dragocene Metale, (), Belgrade, Yugoslavia, and of the Bureau International des Poids et Mesures (BIPM), has been carried out in 60 Co radiation. The standard of air kerma is a graphite cavity ionization chamber constructed at the Orszagos Mérésügyi Hivatal (OMH), Budapest, Hungary (type ND1005/A, serial number 8304), details of which are given in section 3 of this report. The BIPM air kerma standard is described in [1]. The standards of the and the BIPM were last compared in 1991 [2] and the present comparison took place at the BIPM in November 2001. 1

2. Conditions of measurement The air kerma is determined at the BIPM under the following conditions [3]: - the distance from source to reference plane is 1 m, - the field size in air at the reference plane is 10 cm 10 cm, the photon fluence rate at the centre of each side of the square being 50 % of the photon fluence rate at the centre of the square. 3. Determination of the air kerma rate The air kerma rate is determined using the relation where I W 1 en K& µ = sc,a k i, m e 1 g ρ a,c I/m is the ionization current per unit mass of air measured by the standard, W is the average energy spent by an electron of charge e to produce an ion pair in dry air, g is the fraction of electron energy lost to bremsstrahlung, (µ en /ρ) a,c is the ratio of the mean mass-energy absorption coefficients of air and graphite, s c,a is the ratio of the mean stopping powers of graphite and air, k i is the product of the correction factors to be applied to the standard. The main characteristics of the primary standard are given in Table 1. Table 1. Characteristics of the standard for the measurement of air kerma Standard Primary Type ND1005/A - 8304 Nominal values Chamber Outer height / mm 19 Outer diameter / mm 19 Inner height / mm 11 Inner diameter / mm 11 Wall thickness / mm 4 Electrode Diameter / mm 2 Height / mm 10 Volume Air cavity / cm 3 1.0126 relative uncertainty / cm 3 0.0003 Wall Material ultrapure graphite Density / g cm 3 1.75 Impurity fraction < 1.5 10 4 Applied tension Voltage / V 250 2

4. Experimental results Data concerning the various factors entering in the determination of air kerma in the 60 Co beam using the two standards are shown in Table 2. They include the physical constants [4], the correction factors entering in, the volume of each chamber cavity and the associated uncertainties [3]. Also shown are the relative uncertainties in the ratio = K& K&. R K BIPM Table 2. Physical constants and correction factors entering in the determination of air kerma and their estimated relative standard uncertainties in the BIPM 60 Co beam BIPM values 100 Relative uncertainty values 100 Relative uncertainty 100 Relative uncertainty of R K s i u i s i u i s i u i Physical constants dry air density / kg m 3 (2) 1.2930-0.01 1.2930-0.01 - - (µ en /ρ) a,c 0.9985-0.05 0.9985-0.05 - - stopping power ratio sc, a 1.0010 1.0009-0.11 W/e /(J C 1 ) 33.97 33.97-0.11 - - g fraction of energy lost to bremsstrahlung 0.0032-0.02 0.0032-0.02 - - Correction factors k s recombination losses 1.0015 0.01 0.01 1.0021 0.01 0.03 0.01 0.03 k h humidity 0.9970-0.03 0.9970-0.03 - - k st stem scattering 1.0000 0.01-0.9998 0.01 0.01 0.01 0.01 k att wall attenuation 1.0398 0.01 0.04 k sc wall scattering 0.9720 0.01 0.07 1.0231 0.03 0.08 0.03 0.11 k CEP mean origin of electrons 0.9922-0.01 0.9966 k an axial non-uniformity 0.9964-0.07 0.9998-0.10-0.12 k rn radial non-uniformity 1.0016 0.01 0.02 1.0003 0.01 0.02 0.01 0.03 Measurement of I/vρ v volume / cm 3 6.8028 0.01 0.03 1.0126 0.01 0.03 0.01 0.04 I ionization current 0.01 0.02 0.01 0.04 0.01 0.04 Uncertainty quadratic summation 0.03 0.17 0.04 0.19 0.04 0.18 combined uncertainty 0.17 0.19 0.18 Expressed as one standard uncertainty. s i represents the relative standard Type A uncertainty, estimated by statistical methods; u i represents the relative standard Type B uncertainty, estimated by other means. (2) At 101 325 Pa and 273.15 K. The correction factors for the standard were determined at the. The results of some measurements at the BIPM of the effects of ion recombination were also used. The ratio of the ionization currents obtained for the standard with applied voltages of 250 V and 80 V (using both polarities) was measured for four different air kerma rates in 3

the BIPM 60 Co beam. A linear fit to these data identified an ion recombination effect at 250V identical to that previously determined at the BIPM for this chamber type. Consequently, the correction factor k s of 1.0021 (0.0001) for ion recombination at 250 V and 85 pa was applied to the standard in the BIPM beam. Figure 1 shows the experimental determination. This correction is effectively for initial recombination and diffusion combined as the volume recombination is not significant at the BIPM air kerma rate. Consequently, a similar correction would be expected to apply at the as a larger correction would only be appropriate for an air kerma rate in excess of 5 mgy s 1. 1.0065 Figure 1 primary standard for Co-60 air kerma recombination effect 1.0060 y = 1 + (n - 1)A/V + (n 2-1)m 2 (g/v 2 )Iv where n = 3.125 I250 / I80 1.0055 1.0050 1.0045 The best estimate for A = 0.501 (0.005) V and for g = 0.11 (0.03) mm where m 2 = 3.91 (0.07) x 10 2 s m -1 pc -1 V 2 for the ambient conditions (100.6 kpa, 19.58 C and 50 % humidity) 1.0040 1.0035 ND1005/A-8304 ks= 1 + A/V + m 2 (g/v 2 )Iv ks = 1.0021 (0.0001) at 85 pa and 250 V the volume recombination component is less than 10-4 1.0030 0 20 40 60 80 100 I250 / pa The procedure of adding graphite to the walls of the cavity chamber has been used in the past to determine the attenuation in the walls and the scatter correction at the [2]. The value thus obtained of k att k sc = 1.0173 (0.0010) for this standard agrees with that measured by the method at the BIPM for a transfer standard of the same shape and size. Combined with the value k CEP = 0.9966, this gives the total wall correction 1.0138. However, improvements to replace the extrapolation method have been made recently using the Monte Carlo code EGS4 plus the FOTELP extension developed at the Technical Institute in Belgrade according to the Los Alamos design. The result of these calculations produces a value for the total wall correction (k att k sc k CEP ) of 1.0196 with a statistical uncertainty s = 0.0003. This value is slightly lower than the value of 1.0211 (s = 0.0001) calculated for the same chamber at the NRC, Canada [5] using EGSnrc. The OMH has also calculated (using EGSnrc) a value of 1.0212 (s = 0.0003) for their primary standard of the same type [6], compared to the value of 1.0219 (s = 0.0001) calculated at the NRC for this OMH chamber. The correction factor k rn for the radial non-uniformity of the BIPM beam over the section of the standard had been estimated previously [7]; its numerical value is 1.0003. The correction factor for axial non-uniformity was taken as 0.997 (0.001) in 1991 and since 1996 has been taken as 0.9998 (0.0007) for this chamber type. 4

The result of the comparison R K = K& / K& BIPM is given in Table 3. Five independent measurements were made over eight days using the standard. The relative combined uncertainty associated with these measurements is 4 10 4. The K & BIPM value of 2.7293 (s = 0.0003) mgy s 1 is the mean of measurements that were performed over a period of several months before and after the present comparison. The ratio of the values of the air kerma rate determined by the and the BIPM standards is 1.0079 with a combined standard uncertainty, u c of 0.0018. Some of the uncertainties in K & which appear in both the BIPM and the determinations (such as air density, W/e, µ en /ρ, g, s c,a and k h ) cancel when evaluating the uncertainty of R K, as shown in Table 2. Table 3. Results of the -BIPM comparison of primary standards of air kerma I / pa u I / pa K & / mgy s 1 R K u c 103.826 0.037 2.7510 1.0079 0.0018 The & K values refer to an evacuated path length between source and standard and are given at the reference date of 2001-01-01, 0h UT where the half life of 60 Co is taken as 1 925.5 days (u = 0.5 days) [8]. 6. Discussion The standards of the and the BIPM were last compared in 1991 [2]. At that time the experimental method was used to determine the correction factor for the wall effect. The comparison result was 0.9982 (0.0019). In comparing this with the present comparison result of 1.0079 (0.0018) one must take into account changes in the values used for the wall effect and the axial non-uniformity correction for the standard. The total wall correction factor k att k sc k CEP (measured) is 1.0138 and by calculation is 1.0196, a ratio of 1.0057 (0.0009). The axial non-uniformity correction has changed from 0.997 to 0.9998, a ratio of 1.0028. The has recently (1999) made a comparison directly against the OMH primary standard, at the OMH [9]. This direct bilateral comparison result is R / OMH = 0.9999 (0.0025), with both laboratories using the experimental value for the wall correction. Comparing the previous comparisons of 1991 and 1994 that the two NMIs made with the BIPM gives an indirect result for R / OMH of 1.0007, which agrees with the 1999 result within the uncertainties. The OMH has recently declared a new value for its air kerma standard [6]. Using this value to correct the 1994 OMH / BIPM comparison and taking the result of the present / BIPM comparison, the new ratio of the indirect comparison R / OMH through the BIPM is 0.9970 (0.0027). The difference (1.0037) between this value and that of the previous indirect comparison can be attributed to the differences in the newly applied correction factors, although this value also agrees with the 1999 direct bilateral comparison within the overall uncertainties. The results of comparisons at the BIPM with standards of the same type as that of the are given in Table 4 and shown in Figure 2 (in green). There appear to be two groups of results, each of which is self-consistent within the estimated uncertainties, but different from each other by up to 1 %. The group with the higher values has re-evaluated its wall correction factor using MC calculations. However, some of the other NMIs with 5

standards of different shapes have also used MC calculations but their results match the lower group. It is anticipated that it will be a further thirteen months before all the NMIs are ready for their results to be entered into the BIPM key comparison database (KCDB). In the meantime, the BIPM is also reviewing its experimental and calculated results for the wall corrections of its primary standard. Table 4. Comparison of the ND1005-type standards belonging to national laboratories with the BIPM standard Laboratory and year & KLab / & K BIPM 100 Relative standard uncertainty 60 Co u c UDZ 1992 [10] 0.9992 0.2 OMH 1972 [11] 1.0039 0.5 1986 [12] 1.0009 0.3 1994 [13] [6] 1.0109 0.2 BEV 1980, 1989 [14,15] 1.0014 0.3 1994 [16] 1.0040 0.2 1995 [17] 1.0029 0.3 LNMRI 1986 [18] 1.0010 0.3 1995 [19] 1.0004 0.2 GUM 1996 [20] 0.9987 0.3 ENEA 1998 [21]* 1.0103 0.3 SMU 2000 [22]* 1.0033 0.3 [this work] 1.0079 0.2 * Provisional results 7. Conclusion The comparison result for the standard for air kerma in 60 Co gamma radiation is R K = 1.0079 (0.0018). The result is in agreement with the previous comparison when the new method of calculating the correction factors (a difference of 1.0057 for the wall effect and a difference of 1.0028 for the axial non-uniformity) for the standard are taken into account. 6

The results for all the NMIs are shown in Figure 2 where some differences between the NMIs can be attributed to the method of correction for the wall effect. All the NMIs and the BIPM are currently re-evaluating their cavity chamber wall correction factors and this may well change the overall picture for the comparison results in the future. Once agreed, these data will be used in the Appendix B of the KCDB for the BIPM key comparison of air kerma in 60 Co gamma radiation. Figure 2 International air kerma comparison results Comparison result KNMI / KBIPM 1.020 1.015 1.010 1.005 1.000 0.995 0.990 ND1005 type standards provisional results ARP BARC BEV BNM CMI ENEA GUM LNMRI NIM NIST NMi NMIJ NPL NRC OMH PTB SMU VNIIM 1997 1998 1995 1993 1992 1998 1996 1995 2001 1996 1996 2001 1998 1989 1994 2000 2000 2001 1997 National metrology institute and year of comparison References [1] BOUTILLON M. and NIATEL M.-T., A study of a graphite cavity chamber for absolute measurements of 60 Co gamma rays, Metrologia, 1973, 9, 139-146. [2] PERROCHE A.-M.and SPASIĆ JOKIĆ V., Comparison of the air kerma standards of and BIPM for 60 Co radiation, Rapport BIPM-92/3, 1992, 6 pages. [3] BOUTILLON M. ALLISY-ROBERTS P.J. and BURNS D.T., Measuring conditions used for the calibration of ionization chambers at the BIPM, Rapport BIPM-01/04, 2001, 19 pages. [4] BIPM, Constantes physiques pour les étalons de mesure de rayonnement, BIPM Com. Cons. Etalons Mes. Ray. Ionisants, Section (I), 1985, 11, p. R45 (Paris: Offilib). [5] Rogers D.W.O. and Treurniet J. (1999) Monte Carlo calculated wall and axial nonuniformity corrections for primary standards of air kerma, NRCC Report PIRS 663 and CCRI Working document CCRI(I)/99-26, 25 p. [6] Csete I., New correction factors for the OMH air kerma standard for 137 Cs and 60 Co Radiation (2001) CCRI Working document CCRI(I)/01-03, 2 p. 7

[7] BOUTILLON M. and PERROCHE A.-M., Radial non-uniformity of the BIPM 60 Co beam, Rapport BIPM-89/2, 1989, 9 pages. [8] IAEA, X- and gamma-ray standards for detector calibration, IAEA TECDOC-619, 1991. [9] SPASIĆ JOKIĆ V., CSETE I. and MACHULA G., Comparison of air kerma primary standards between and OMH in 60 Co beam from the standpoint of radiotherapy, International Journal Archive of Oncology, No 8/3 2000, 111-112. [10] PERROCHE A.-M., BOUTILLON M., KOVAR I and WAGNER R., Comparison of the air kerma standards of the UDZ and the BIPM for 60 Co radiation, Rapport BIPM-93/1, 1993, 6 pages. [11] NIATEL M.-T., Comparaison des étalons d exposition ( 60 Co) du BIPM et de l OMH, Procès-verbaux du CIPM, 41 (1973) 62 (Paris: Offilib). [12] ALLISY A., BIPM comparison of exposure rate and air kerma rate in 60 Co gamma rays, BIPM Rapport, October 1986. [13] PERROCHE A.-M., BOUTILLON M. and CSETE I., Comparison of the standards of air kerma of the OMH and the BIPM for 137 Cs and 60 Co γ rays, Rapport BIPM-94/13, 1994, 10 pages. [14] NIATEL M.-T. and BOUTILLON M., Comparaison d étalon d exposition, Procès-verbaux du CIPM, 49 (1981) 61 (Paris: Offilib). [15] LEITNER A., Adoption of new values of physical constants for radiation measurement standards, Letter to BIPM, August 1989. [16] PERROCHE A.-M., BOUTILLON M. and LEITNER A., Comparison of the standards of air kerma and absorbed dose to water of the BEV and the BIPM for 60 Co γ rays, Rapport BIPM-94/7, 1994, 7 pages. [17] ALLISY-ROBERTS P.J., BOUTILLON M. and WITZANI J., Comparisons of the standards of air kerma of the BEV and the BIPM for 137 Cs and 60 Co γ rays, Rapport BIPM-95/5, 1995, 9 pages. [18] DE ALMEIDA C.E. and NIATEL M-T., Comparisons between IRD and BIPM exposure and air kerma standards for cobalt-60 gamma rays, Rapport BIPM-86/12, 1986, 20 pages. [19] ALLISY-ROBERTS P.J., BOUTILLON M. and RODRIGUES L.N., Comparison of the standards of air kerma of the LNMRI and the BIPM for 60 Co γ rays, Rapport BIPM- 96/3, 1996, 8 pages. [20] ALLISY-ROBERTS P.J., BOUTILLON M., REFEROWSKI Z. and PAZ N. Comparison of the standards of air kerma of the GUM and the BIPM for 60 Co γ rays, Rapport BIPM-97/2, 1997, 6 pages. [21] ALLISY-ROBERTS P.J., BURNS D.T., LAITANO, F and M.P.. Comparison of the standards of air kerma of the ENEA and the BIPM for 60 Co γ rays, Rapport BIPM-in preparation. [22] ALLISY-ROBERTS P.J., BURNS D.T. and GABRIS F. Comparison of the standards of air kerma of the SMU Slovakia and the BIPM for 60 Co γ rays, Rapport BIPM-01/A in preparation. January 2002 8