(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

Similar documents
1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

TECHNETIUM-99 IN WATER

NICKEL-63/59 IN WATER

enable measurement. This method separates these isotopes effectively.

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

RARE EARTH FLUORIDE MICROPRECIPITATION

THORIUM, PLUTONIUM, AND URANIUM IN WATER

TECHNETIUM-99 IN SOIL

AMERICIUM, NEPTUNIUM, PLUTONIUM, THORIUM, CURIUM, URANIUM, AND STRONTIUM IN WATER

Contact Person(s) : Anna Berne APPLICATION

TECHNETIUM-99 IN WATER

Eichrom Technologies, Inc. Analytical Procedures Rev. 1.5 February 10, 2005 Page 1 of 9

Pu and Np-237 in seawater samples Version /03/14. Summary

ELECTRODEPOSITION OF ACTINIDES

TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

Method NumberUSTUR 150

Uranium from water sample

Rapid Separations. Activity Radioactive Solutions. Lawrence Jassin Eichrom Technologies LLC March 3, 2008 Pittcon 2008

WM 05 Conference, February 27 March 3, 2005, Tucson, AZ PREPARATION AND SEPARATION METHODS BY TWO INDEPENDENT LABORATORIES

Rapid Methods for the Determination of Sr-90 in Steel and Concrete Samples

Contact Person : Marie Lawrence APPLICATION

Revised material in Section 4, Analytical Chemistry

EXPERIMENT: LIMITING REAGENT. NOTE: Students should have moles of reactants in DATASHEET converted into masses in grams prior to the lab period.

Working Copy. tlrq /rb I 'B-16. Determination of Gross Alpha/Beta Activity. Revision 0. Laboratory Manag erllqao/rso. Effective Date. lnitials.

Determination of 226 Ra in water using ion exchange resin and alpha spectrometry study and validation.

A Comparison of EPA Method and ASTM D6239 for Uranium in Hard Water Matrices. Robert L. Metzger & Pierre Pouquette

Automation of the radiochemical procedures for the sequential separation of radionuclides

Determination of 210 Pb and 210 Po in Water Samples

Rapid Determination of Ra-226 in Environmental Samples

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

QAM-I-116 Preparation of Labware

Procedure for determining the activity concentration of airborne particulate radium-226

K.M. Hoffmann and D. C. Seely

Part II. Cu(OH)2(s) CuO(s)

Procedure for determining the specific activity of radium-226 in foodstuffs of plant origin

AQA Chemistry A-level

Chemistry 151 Last Updated Dec Lab 8: Precipitation Reactions and Limiting Reagents

Rapid methods for the determination of actinides and Sr in environmental samples

Rapid Column Extraction Methods for Urine

Preparing Extension Products for Electrophoresis

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Determination of 126 Sn in nuclear wastes by using TEVA resin

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Test Method: CPSC-CH-E

CIE Chemistry A-Level Practicals for Papers 3 and 5

Method Number USTUR 510

Alpha spectrometry enriched uranium urinalysis results from IPEN

Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices

CHM 152 Lab 5: Qualitative Analysis updated May, 2011

SEQUENTIAL DETERMINATION OF AMERICIUM, PLUTONIUM AND URANIUM IN LIQUID EFFLUENTS FROM NUCLEAR POWER PLANTS

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Technical Notes for EPA Method Gross Alpha and Gross Beta Radioactivity in Drinking Water

using simple distillation and paper chromatography practical to obtain a

Nitrogen, Total Inorganic

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Minneapolis Community and Technical College. Separation of Components of a Mixture

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

A Rapid Method for Determination of Uranium, Americium, Plutonium and Thorium in Soils Samples. Serdeiro, N.H. and Marabini, S.

Method NumberUSTUR 100

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Available online at ScienceDirect. Energy Procedia 89 (2016 )

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

Laboratory 3. Development of an Equation. Objectives. Introduction

Simultaneous measurement of 89 Sr and 90 Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method

Analysis of Technetium-99 in Marshall Islands Soil Samples by ICP-MS

and their Use in Food Methods

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

Chem 1B Saddleback College Dr. White 1. Experiment 5: Separation and Identification of Group I Cations (The Chloride Group: Ag +, Pb 2+, and Hg 2

VALIDATION OF AN IMPROVED METHOD FOR THE SEPARATION AND MEASUREMENT OF Pb-210 AND Po-210

Chemical Reactions: The Copper Cycle

Procedure for determining thorium isotopes in wastewater by an extractionchromatographic

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Classifying Chemical Reactions

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Determination of Selenium-79 in Aqueous Samples

QUALITATIVE ANALYSIS OF GROUP I CATIONS

Experiment 8 - Double Displacement Reactions

NOTE: This method does not include all of the. specifications (e.g., equipment and supplies) and procedures

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

The problems as we saw them were;

GENERAL INSTRUCTIONS GENERAL PREPARATION

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

DISCLAIMER: This method:

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

2 (CH 3 CH 2 ) 2 NH diethylamine

Recovery of Copper Renee Y. Becker Manatee Community College

CALCIUM (EGTA-Titrimetric)

To precipitate nickel (II) sulfide, the sulfide ion concentration must be a lot larger:

Qualitative Analysis I - Cations

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

Synthesis of Benzoic Acid

GRIGNARD REACTION Synthesis of Benzoic Acid

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Chem 100 Section Experiment 12 Name Partner s Name. Radioactivity

Oxygen Demand, Chemical

Transcription:

Analytical Procedure RADIUM IN WATER (CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This is a method for separation and measurement of radium-226 and radium-228 in water. This method is meant to be used in conjunction with Eichrom Method SPA01 for the rare earth fluoride micro precipitation preparation of sources for 228 Ac( 228 Ra) analysis by gas flow proportional counting. 1.2. This method does not address all aspects of safety, quality control, calibration or instrument set-up. However, enough detail is given for a trained radiochemist to achieve accurate and precise results for the analysis of the analyte(s) from the appropriate matrix, when incorporating the appropriate agency or laboratory safety, quality and laboratory control standards. 2. SUMMARY OF METHOD 2.1. This test method is based on the utilization of solid phase extraction of radium from water samples. The detection of the 226 Ra is by alpha spectrometry and 228 Ra via 228 Ac by gas flow proportional beta counter. 2.2. An aliquot of the sample is measured into a beaker, barium carrier and 133 Ba are added. Radium and barium are sorbed on a cation exchange column, eluted, evaporated to dryness, and dissolved in 0.095M HNO 3. 228 Ac is selectively retained on a column of LN resin. 228 Ac is eluted with 0.35M HNO 3, precipitated with rare earth fluoride, and collected on a resolve filter for measurement by gas flow proportional counting. 226 Ra and 133 Ba are collected from the LN load solution, precipitated with barium sulfate, and collected on a resolve filter. 133 Ba is counted using a gamma spectrometry while 226 Ra is counted via alpha spectrometry. 3. SIGNIFICANCE OF USE 3.1. This is a rapid, reliable method for measurement of 226 Ra and 228 Ra in water samples that is more cost-effective and efficient than traditional ion exchange, solvent extraction and precipitation techniques. May 1, 2014 Page 1 of 9

4. INTERFERENCES 4.1. Potential beta emitters such as bismuth, yttrium and thorium would be retained on the solid phase extraction resin column, while eluting actinium from the resin. 4.2. Interferences from other radioactive rare earth elements are eliminated under the stripping conditions of 0.35M HNO 3. 4.3. High levels of calcium can interfere with Ra sorption on the ion exchange resin column and can cause excessive quantities of precipitate in the final barium sulfate micro precipitation step. For samples containing less than 200 ppm, use 500 ml to 1 liter. Sample size is limited to 100 ml if the Ca content is greater than 200 ppm but less than or equal to 500 ppm. The method has not been tested on samples containing greater than 500 ppm calcium. 4.4. This method is suitable for the measurement of alpha emitting radium isotopes and 228 Ra (via 228 Ac) from water samples. The measurement of 228 Ac may be biased high if samples contain high levels of 227 Ac (from 235 U decay chain) or fission products, such as 140 Ba, 140 La, and Ce radionuclides. If measuring 228 Ra from samples potentially containing these interfering radionuclides, a method isolating radium and then allowing for 228 Ac in-growth would be more effective (Eichrom Method RAW01). 5. APPARATUS Analytical balance, 0.0001 g sensitivity Cartridge reservoirs, 10mL (Eichrom Part: AR-200-RV10) or 20mL (Eichrom Part: AR-200-RV20) Centrifuge tubes, 50mL Eichrom vacuum box system, Eichrom Part: AR-12-BOX or AR-24-BOX Flame burner Fume hood Gamma spectrometry system Hotplate Ion exchange column, 1 to 1.5cm diameter column with 10mL of cation exchange resin, Eichrom Part: AC-20E-20M (column), Eichrom Part: AC-20X-20M (funnel) Low background gas flow proportional counter with appropriate sample carriers and planchets Petri dishes, plastic, 5-1/2 x 1cm Stir rods, glass May 1, 2014 Page 2 of 9

6. REAGENTS Vacuum box white inner support tube-pe- Eichrom Part: AR-1000-TUBE- PE Vacuum box yellow outer tips- Eichrom Part: AR-1000-OT Vacuum pump - 115 V, 60 Hz Fisher Part: 01-092-25 (or equivalent) or house vacuum Vortex mixer Optional: vacuum box inner liner - For collection of load and rinse fractions, Eichrom Part: AR-12-LINER or AR-24-LINER Note: Analytical grade or ACS grade reagents are recommended. Ammonium sulfate,(nh 4 ) 2 SO 4 133 Ba tracer (~3000 dpm/ml) Barium chloride dihydrate, BaCl 2 2H 2 O Cation exchange resin, hydrogen form, 100-200 mesh, Eichrom Part C8-B500-M-H Deionized water, all reagents are prepared with deionized water Hydrogen peroxide (30%), concentrated H 2 O 2 LN resin, 2mL prepacked cartridge, 50-100 m, Eichrom Part LN-R50-S Nitric acid (70%), concentrated HNO 3 6.1. Barium carrier (0.75 mg/ml)- Dissolve 0.34g BaCl 2 2H 2 O, in water. Dilute to 250mL with water. 6.2. Cerium carrier- Dissolve 0.155g cerium nitrate hexahydrate in 50mL water. Dilute to 100 ml with water. 6.3. Ethanol, 80%- Add 80 ml denatured ethanol to 20 ml water. 6.4. Nitric acid solution (0.095M)- Add 5.9 ml of concentrated HNO 3 to 900mL of water. Dilute to 1L with water. 6.5. Nitric acid solution (0.35M)- Add 22mL of concentrated HNO 3 to 800mL of water. Dilute to 1L with water. 6.6. Nitric acid solution (0.1M)- Add 6.3 ml of concentrated HNO 3 to 800 ml of water. Dilute to 1L with water. 6.7. Nitric acid solution (8M)- Add 500 ml of concentrated HNO 3 to 400 ml of water. Dilute to 1L with water. May 1, 2014 Page 3 of 9

7. PROCEDURE 7.1. Water Sample Preparation: 7.1.1. If required, filter the sample through a 0.45 micron filter. 7.1.2. Aliquot 500 to 1000mL of the sample (or enough to meet required detection limit) into an appropriate size beaker. Add an appropriate amount of 133 Ba tracer. 7.1.3. Acidify sample with nitric acid to ph 2, if necessary. 7.1.4. Prepare a cation exchange column containing 10 ml of cation exchange resin. 7.1.5. Precondition the column with 50mL of 0.1M HNO 3. 7.1.6. Pass the sample through the column at the rate of not more than 5 ml/min. 7.1.7. Rinse the column with 25mL of 0.1M HNO 3. 7.1.8. Properly dispose of the feed and rinse. 7.1.9. Elute radium, barium, and actinium (and other cations) with 100mL of 8M HNO 3 into a 250mL beaker. 7.1.10. Evaporate the eluate completely to dryness on a hot plate in a fume hood. Note: The effectiveness of the subsequent radium/ 228 Ac separation on LN resin is dependent on the concentration of HNO 3 in the solution prepared in step 7.1.10. Traces of HNO 3 remaining from the evaporation step 7.1.10. can prevent the uptake of 228 Ac by LN resin. Ensure complete evaporation of all HNO 3 in step 7.1.10. 7.1.11. Dissolve the residue in 10mL of 0.095 M HNO 3. If necessary, cover with a watch glass and heat gently. Check that ph is ~1. Adjust to ph 1 as necessary. 7.2. 228 Ac Separation Using Ln Resin: 7.2.1. Place the inner tube rack (supplied with vacuum box system) into the vacuum box with the centrifuge tubes in the rack. Fit the lid to the vacuum system box. Alternatively, a vacuum box inner liner may be used. May 1, 2014 Page 4 of 9

7.2.2. Place yellow outer tips into all 12 or 24 openings in the lid of the vacuum box. Fit a white inner support tube into each yellow tip. 7.2.3. For each sample solution, fit an LN Resin cartridge on to the inner support tube. 7.2.4. Add syringe barrels (funnels/reservoirs) to the top end of each LN Resin cartridge. 7.2.5. Connect the vacuum pump to the box. Turn the vacuum pump on and ensure proper fitting of the lid. Note: The unused openings on the vacuum box should be sealed. Vacuum manifold plugs can be used to plug unused white tips to achieve good seal during the separation. Alternatively, unused vacuum box holes can be sealed with scotch tape. 7.2.6. Add 5mL of 0.095 M HNO 3 to each LN Resin cartridge reservoir to precondition the resin. Adjust the vacuum to achieve a flow rate of 1mL/min. Allow the solution to completely pass through each cartridge. 7.2.7. Disengage the vacuum. Place a clean, labeled 50mL polypropylene centrifuge tube under each LN Resin cartridge to collect radium and barium. 7.2.8. Transfer each sample solution to the appropriate LN Resin cartridge reservoir. Engage vacuum. Allow the solution to completely pass through each LN Resin cartridge at 1mL/min. 228 Ac will be retained on the LN Resin cartridge, while radium and barium elute into the centrifuge tube. 7.2.9. Rinse the sample beakers with 5mL of 0.095M HNO 3. Add the rinse to the appropriate LN Resin cartridge reservoir. Record the time and date of this rinse. This will be the separation of 228 Ac from 228 Ra. 7.2.10. Rinse the LN Resin cartridge with 5mL of 0.095M HNO 3. Allow the solution to completely pass through each cartridge at 1mL/min. 7.2.11. Disengage vacuum. Set the combined eluate from steps 7.2.8. to 7.2.10. aside for source preparation for the measurement of radium and barium. 7.2.12. Place a clean, labeled centrifuge tube under each column. Add 10 ml of 0.35M HNO 3 to each LN Resin cartridge to elute 228 Ac. May 1, 2014 Page 5 of 9

Engage vacuum. Allow solution to completely pass through each cartridge. Note: 228 Ac has a 6.13 hour half life. The following steps for the determination of 228 Ac must be performed quickly. 7.2.13. Prepare sources for the determination of 228 Ac using rare earth fluoride micro precipitation (Eichrom Method SPA-01). 7.2.14. Measure 228 Ac using a low background gas flow proportional counter. 7.3. Barium sulfate micro-precipitation for 226 Ra 7.3.1. Count the eluate from step 7.2.11. for 133 Ba on a Gamma counter for tracer recovery. 7.3.2. Add 3.0g of ammonium sulfate. Mix to dissolve. 7.3.3. Add 100 L of barium carrier to each sample. Swirl to mix. 7.3.4. Add 5mL of isopropanol to each sample. Swirl to mix. 7.3.5. Place tubes in an ice- water bath for at least 30 minutes. 7.3.6. Prepare alpha spectrometry sources on resolve filters as outlined in Eichrom Method SPA01, steps 5.4. to 5.15. 7.3.7. Count samples by alpha spectrometry. 8. CALCULATIONS Calculate 228 Ra activity: (To convert pci/l to Bq/L, multiply by 0.037): 228 Ra (pci/l) = A 2.22 E V Y e t 2 - t1 t2 1 e where: A = net count rate, cpm E = counting efficiency expressed as fraction Y = 133 Ba (Ra) yield expressed as fraction V = Sample volume (liters) t 1 = decay time of 228 Ac, from start of rinse until start of counting (minutes) May 1, 2014 Page 6 of 9

t 2 = counting time (minutes) = decay constant of 228 Ac (1.88*10-3 min -1 ) Calculation for 226 Ra activity (To convert pci/l to Bq/L, multiply by 0.037): Ra-226 (pci/l) = S B 2.22. E Y V where: S = sample counts per minute B = background counts per minute E = efficiency of counter V = volume of samples in liters Y = barium-133 yield 9. PERFORMANCE DATA 9.1. This method has been used to analyze various intercomparison and reference samples supplied by external organizations. Chemical recovery and agreement with reference values was excellent. (To convert pci/l to Bq/L multiply the value by 0.037, therefore 1.41 pci/l = 0.052 Bq/L or 2 mbq/l.) Data below was generated from 500 ml samples of drinking water samples supplied as indicated. For more details, contact Eichrom: Chemical Yield (Ba-133) Eichrom Result ( 226 Ra - pci/l) Reference Value ( 226 Ra - pci/l) US EPA (9/18/98) 96% 1.41 0.17 1.7 0.5 New Jersey State Lab 91% 8.64 1 9.1 0.5 Georgia Tech (S8933) 88% 22.6 3.0 18.0 2.0 Georgia Tech (WS14776) 88% 4.14 0.58 3.3 0.3 May 1, 2014 Page 7 of 9

10.REFERENCES 1) Burnett, W.C., P.H. Cable, and Russ Moser, Determination of Radium- 228 in Natural Waters Using Extraction Chromatographic Resins, Radioactivity & Radiochemistry, Vol. 6, No. 3, pp. 36-43 (1995). 2) Maxwell, S.L., et al., Rapid method for determination of 228Ra in water samples, J. Radioanal. Nucl. Chem. 295, 2181-2188, (2013). 3) Maxwell, S.L., et al., Rapid method for determination of 226Ra in urine samples, J. Radioanal. Nucl. Chem. 300, 1159-1166 (2014). May 1, 2014 Page 8 of 9

May 1, 2014 Page 9 of 9