Aroclors, Homologs and Congeners An Evaluation of the Options for PCB Analysis and a Comparison of the Interpretive Value

Similar documents
2015 Delaware Estuary Science & Environmental Summit Jim Occhialini, Cindy McQueen Alpha Analytical

Polychlorinated biphenyls (PCBs)

PCB Chemistry 101. Presented by Valerie Tillinghast O Reilly, Talbot & Okun Associates, Inc.

Analyzing PCBs in Source Materials and Environmental Media: Soil, Water and Air. Jim Occhhialini Jim Okun Patricia McIsaac

Data Glossary. Acceptance criteria - specific limits placed on characteristics of an item, process, or service defined in requirements documents.

PCB Alternative Analysis Comparison of Aroclor to low and high-resolution GCMS. Laura Inouye (Ecology)

Worldwide Recognition for the Synthesis of All 209 PCB Congeners

The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners

Jennifer Bowman Dr. Natalie Kruse Dr. Glen Jackson Dr. Dina Lopez Mengliang Zhang

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Demonstration of a TEQ Selective PCB Immunoassay

PCBs IN FRESHWATER AND MARINE SEDIMENTS: TRANSPORT, TRANSFORMATION AND TREATMENT. Organized by. D.A. Dzombak and G.V. Lowry

SPME EXTRACTION OF THE PCB S CONTAINING TRANSFORMER OILS

Analysis of SVOCs in Indoor Air Using Thermal Desorption GC/MS

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

SEDIMENT QUALITY OF THE NY/NJ HARBOR SYSTEM

Polychlorinated Biphenyls (PCBs): Environmental Chemistry

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Analysis of Alkyl PAHs And Geochemical Biomarkers

SUPELCO. The Analysis of all 209 PCB Congeners on the SPB -Octyl and MDN -5S Capillary Columns. Katherine K. Stenerson and Leonard M.

METHOD 8082A. POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

HRMS PBDE Analysis on a Thermo DFS. Dave Hope, Pacific Rim Laboratories Inc

U.S. EPA Method 8270 for multicomponent analyte determination

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Determination of Environmental Pollutants by Gas. Chromatography/Mass Spectrometry with Chemometrics. A dissertation presented to.

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

Development and Use of Screening Methods for Rapid Characterization. Barry Lesnik, USEPA and Sara Hartwell, SAIC

MR. TELLIARD: Our next speaker is Brian. MR. FOWLER: First of all, I would like. to thank Bill and the EPA for the conference, and I think it

Method 680. Determination of Pesticides and PCBs in Water and Soil/Sediment by Gas Chromatography/Mass Spectrometry. November 1985

PosterReprint INTRODUCTION

A Technique for Determining Total Oxidizable Precursors (TOP) of Perfluoroalkyl Compounds

ONE STEP CLOSER TO A COOK BOOK METHOD FOR DIOXIN ANALYSIS PART 2: ANALYSIS OF FOOD SAMPLES

METHOD 3600C CLEANUP

Expedited Field Analysis Method for Polychlorinated Biphenyls. Department of Chemistry and Biochemistry, Ohio University, Athens, Ohio

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Gas Chromatography Mass Spectrometry (GCMS)

Generating the Right PCB Data: Determination of Aroclors Versus PCB Congeners 8075

DETERMINATION OF POLYCHLORINATED BIPHENYL COMPOUNDS THROUGH GAS CHROMATOGRAPHY COUPLED WITH MASS SPECTROMETRY METHOD

METHOD 3600B CLEANUP

Verification and Review of Data for Chlorinated Dioxins, Furans and PCB Congeners by Isotope Dilution HRGC/ HRMS

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Guidance on the Major Source Determination for Certain Hazardous Air Pollutants

~~LABORATORY DATA CONSULTANTS, INC.

is given for the isotopic fingerprinting methodology.

Annex IX: Risks for PolyChlorinated Biphenyls (PCBs)

Dioxins & PCBs concerns

Fundamentals of the Method for Analysis of Dioxins/Furans in Method 0010/0023A Train Samples

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

GC Analysis of Polybrominated Flame Retardants Application

Organochlorine Pesticides by GCxGC-ECD

CSO/SWO Data Validation Reports June 20, 2014

by Dr. George M. Frame

Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers

METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

OBJECTIVE DATA PACKAGE DELIVERABLES

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

PCBs IN FRESHWATER AND MARINE SEDIMENTS: TRANSPORT, TRANSFORMATION AND TREATMENT. Organized by. D.A. Dzombak and G.V. Lowry

Analysis of Polychlorinated Biphenyls (PCB) by Glass Capillary Gas Chromatography

Table S1. Summary of target PCB congeners. Numbers are BZ numbers (Ballschmiter and Zell, 1980) listed in order of elution from an HT8-PCB column.

Separation of Toxic Coplanar PCB Congeners from Other Congeners in Marine Sediments and Marine Fish Tissues Using Florisil and GC ECD

The Analysis of Dioxins and Dioxin-Like Compounds

Applications of polychlorinated biphenyls

WADA Technical Document TD2003IDCR

1.0 INTRODUCTION AND BACKGROUND

Mass spectrometry is an important part of multicomponent analytical systems designed for diagnosis of metabolic disorders. About 50 different

Sediment Stability in the Lower Passaic River Integration of Multiple Lines of Evidence

KESTREL. April 26, Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578

ANALYSIS OF PCBs IN WATER USING HIGH RESOLUTION GAS CHROMATOGRAPHY/HIGH RESOLUTION MASS SPECTROMETRY

Official Journal of the European Union REGULATIONS

U.S. Army Corps of Engineers

Qualification Code Reference Table Cont.

The Suite for Environmental GC Analysis

EPA Test Methods for GC

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

The following revisions are being implemented for the PCDD/F Supplemental QAPP:

Use the three tables of spectral data on the Data Sheet where appropriate.

Polychlorinated Biphenyl Compounds (PCBs) Determination from Water by Gas Chromatography Coupled with Mass Spectrometry (GC MS)

PCBs and the Great Lakes

Chemical Characterization of Polychlorinated Biphenyls, -Dibenzo-p-Dioxins, and -Dibenzofurans in Technical Kanechlor PCB Formulations in Japan

Ms. Nina Nazarian July 19, 2017 Town Administrator Project No Town of Princeton Document No Town Hall Drive Princeton, MA 01541

How Overly Cautious Risk Assessment Methods Overstate Risk from PCBs in Indoor Air

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application

,,... Partitioning of I?CBS in IMsoker.-

GC-MS screening and PCB analysis of sediment from central Kattegat

95 th Percentiles for Blood and Urine Levels of Chemicals Measured in the Report

Certificate of Analysis


Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Rapid Assay for Screening and Characterizing Microorganisms for the Ability to Degrade Polychlorinated Biphenyls

Official Journal of the European Union

Transcription:

Aroclors, Homologs and Congeners An Evaluation of the Options for PCB Analysis and a Comparison of the Interpretive Value Chuck Neslund, Technical Director, Eurofins Lancaster Laboratories Environmental, LLC NEMC, Orange County, CA August 8-12, 2016 Providing comprehensive scientific resources to environmental clients worldwide. www.lancasterlabsenv.com

Polychlorinated Biphenyls - PCBs Most commonly known for use in transformers as dielectric fluids Also used in hydraulic fluids, lubricants, as plasticizers and in caulking compounds Primary manufacturer was Monsanto product given the trade name Aroclor Aroclor nomenclature indicated the average % chlorine in the mixture i.e. Aroclor 1254 = approx 54% chlorine 2

Why are they important? PCBs bioaccumulate WHO (World Health Organization) has determined that some of the 209, ones referred to as dioxin-like PCBs, dl-pcbs, or coplanar PCBs, may be anticipated to cause cancer People can be exposed to PCBs through breathing in contaminated air, consuming contaminated food, and by skin contact with old electrical equipment that contains PCBs. 3

Polychlorinated Biphenyls - PCBs PCBs can be grouped or identified by three common descriptions; Aroclor a mixture of up to one hundred different congeners, grouped together based on an average percent weight chlorine basis Homolog congeners of the same chlorination level. There are 10 chlorination groupings Congener any of the individual chlorinated biphenyl compounds of which 209 are possible 4

Polychlorinated Biphenyls - Aroclors The most common analysis technique is GC/ECD, SW-846 Method 8082 Identifies and quantifies PCBs as an Aroclor Aroclor 1016 Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Limits are typically in the ug/kg and ug/l range Technique is prone to interferences 5

Polychlorinated Biphenyls - Aroclors Aroclor 1242 Aroclor 1254 Aroclor 1260

Polychlorinated Biphenyls - Aroclors Each Aroclor mix consists of dozens of congeners Congeners with the same number of chlorines on the biphenyl ring are called homologs For example, Aroclor1254 contains; 1% Trichlorobiphenyls 15% Tetrachlorobiphenyls 53% Pentachlorobiphenyls 26% Hexachlorobiphenyls 4% Heptachlorobiphenyls 7

Why are they important? Everything you know about Aroclor PCBs applies in some part to PCB Congeners Not all PCB congeners are found in Aroclors Approximately 130 of the 209 congeners are detected in Aroclors Congeners are also categorized by the number of chlorines substituted on the biphenyl ring These categories are called homolog groups or isomer groups 8

Polychlorinated Biphenyls - Homologs Homologs can be characterized by EPA Method 680 or EPA Method 1668. EPA Method 680 Gas Chromatography/Mass Spectrometry (low resolution) Can be operated full scan or selected ion monitoring (SIM) Therefore, sensitivities similar to what you have with 8270 0.1 ug/l for the lower chlorination homologs 0.3-0.5 ug/l for the higher chlorination homologs Low/single digit ug/kg for soils/solids

Polychlorinated Biphenyls - Homologs Nine congeners are used to characterize the homolog groups PCB 1 PCB 5 PCB 29 PCB 50 PCB 87 PCB 154 PCB 188 PCB 200 PCB 209 Monochlorobiphenyls Dichlorobiphenyls Trichlorobiphenyls Tetrachlorobiphenyls Pentachlorobiphenyls Hexachlorobiphenyls Heptachlorobiphenyls Octachlorobiphenyls Nona- and decachlorobiphenyl

Total Ion Chromatogram of 680 CCAL Abundance 180000 TIC: 0206_003.D\data.ms 160000 140000 120000 100000 80000 60000 40000 20000 Time--> 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00

Polychlorinated biphenyls - Homologs Quantitation is achieved with internal standard calibration using deuterated PAHs, like 8270 Homolog group is determined by summing the areas of all peaks within a given retention time, that have the same mass Even though a select few congeners are used for the calibration response, data does not yield congener information Results will consist of a value for each of the homolog groups and a sum of the homolog groups for a PCB total

TIC of Typical Sample Abundance TIC: 0056_042.D\data.ms 30000 25000 20000 15000 10000 5000 Time--> 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00

TIC of Contaminated Sample Abundance 450000 TIC: 0056_044.D\data.ms 400000 350000 300000 250000 200000 150000 100000 50000 Time--> 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00

Extracted Ion for Pentachlorobiphenyl Abundance Time--> Abundance Ion 326.00 (325.70to 326.70): 0056_057.D\data.ms 120 100 80 60 40 20 0 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 Time--> Ion 328.00 (327.70to 328.70): 0056_057.D\data.ms 120 100 80 60 40 20 0 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00

What are PCB Congeners? A congener is a specific chlorine substitution pattern on a biphenyl ring. There are a total of 209 possible substitution patterns ranging from 1 chlorine up to 10 chlorines 16

Polychlorinated Biphenyls Congeners To monitor and analyze for the more toxic congeners, High Resolution Mass Spectrometry (HRMS) is employed EPA Method 1668 HRGC/HRMS Capillary column to resolve many of the congeners Special clean-up techniques Reporting limits of ng/kg and pg/l 17

Polychlorinated Biphenyls Congeners Able to calibrate for all 209 congeners Calibration is also mostly internal standard except that the compounds used as internal standards are isotopically labeled PCB congeners Able to differentiate between congeners that are constituents of Aroclors and those that are not. Able to differentiate contribution of dl-pcbs from total PCB content 18

Calibration Standard with 209 Congeners

Example Data PCB15

Polychlorinated Biphenyls Congeners Can do fingerprinting of PCB sources based on ratios and relative amounts of the individual congeners Comparison of Aroclor based PCB congeners versus presence of non-aroclor based PCB congeners Homolog results determined by summing of individual congeners that make up each chlorination level. Total PCB concentration as well as special case congeners quantified. 21

Special Case Congeners Dioxin-like PCBs (12) PCB77 PCB81 PCB105 PCB114 PCB118 PCB123 PCB126 PCB156 PCB157 PCB167 PCB169 PCB189 Indicator PCBs (6) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 22

Questions 23