RELATIONSHIP OF SEISMIC RESPONSES AND STRENGTH INDEXES OF GROUND MOTIONS FOR NPP STRUCTURES

Similar documents
Examining the Adequacy of the Spectral Intensity Index for Running Safety Assessment of Railway Vehicles during Earthquakes

EARTHQUAKE OBSERVATION OF A LOW-RISE BUILDING

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

K. Tokimatsu 1 and H. Arai 2. Professor, Dept. of Architecture and Building Engineering, Tokyo Institute of Technology, Japan 2

Blank line 10 pt Keywords: Response Characteristics, Skyscraper, Tohoku-Oki earthquake, Natural operiod

NATIONWIDE SITE AMPLIFICATION ZONATION STUDY USING JAPAN ENGINEERING GEOMORPHOLOGIC CLASSIFICATION MAP

PROBABILISTIC SEISMIC HAZARD MAPS AT GROUND SURFACE IN JAPAN BASED ON SITE EFFECTS ESTIMATED FROM OBSERVED STRONG-MOTION RECORDS

Simulated Earthquake Ground Motion for Structural Design"

Department of Civil Engineering, Kyoto University, by Shunzo OKAMOTO, M. J. A., Sept.

Tokyo, Japan,

Figure Locations of the CWB free-field strong motion stations, the epicenter, and the surface fault of the 1999 Chi-Chi, Taiwan earthquake.

THEORETICAL EVALUATION OF EFFECTS OF SEA ON SEISMIC GROUND MOTION

Estimation Method of Seismic Response Based on Momentary Input Energy Considering Hysteresis Shapes of a Building Structure

Special edition paper Development of Shinkansen Earthquake Impact Assessment System

BROADBAND STRONG MOTION SIMULATION OF THE 2004 NIIGATA- KEN CHUETSU EARTHQUAKE: SOURCE AND SITE EFFECTS

Effects of Multi-directional Shaking in Nonlinear Site Response Analysis: Case Study of 2007 Niigata-ken Chuetsu-oki Earthquake

Actual practices of seismic strong motion estimation at NPP sites

Effects of Surface Geology on Seismic Motion

Source modeling of hypothetical Tokai-Tonankai-Nankai, Japan, earthquake and strong ground motion simulation using the empirical Green s functions

Seismic Response Analysis of Structure Supported by Piles Subjected to Very Large Earthquake Based on 3D-FEM

REPORT ON THE TOHOKU AREA PASIFIC OFFSHORE EARTHQUAKE

The Slapdown Phase in High Acceleration Records of Large Earthquakes

COMPARISON OF FREQUENCY AND TIME-DOMAIN OBJECTIVE FUNCTIONS FOR BOREHOLE STATION'S INVERSE PROBLEMS

ON SEISMIC MOTION NEAR ACTIVE FAULTS BASED ON SEISMIC RECORDS

STRONG GROUND MOTION PREDICTION FOR HUGE SUBDUCTION EARTHQUAKES USING A CHARACTERIZED SOURCE MODEL AND SEVERAL SIMULATION TECHNIQUES

A STUDY ON EARTHQUAKE RESPONSES OF ACTUAL ROCK-FILL DAM AND NUMERICAL ANALYSES

REAL-TIME ASSESSMENT OF EARTHQUAKE DISASTER IN YOKOHAMA BASED ON DENSE STRONG-MOTION NETWORK

Preliminary Analysis for Characteristics of Strong Ground Motion from Gigantic Earthquakes

PREDICTION OF AVERAGE SHEAR-WAVE VELOCITY FOR GROUND SHAKING MAPPING USING THE DIGITAL NATIONAL LAND INFORMATION OF JAPAN

Revision of the AESJ Standard for Seismic Probabilistic Risk Assessment (2) Seismic Hazard Evaluation

PROBABILITY-BASED DESIGN EARTHQUAKE LOAD CONSIDERING ACTIVE FAULT

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

Damage Estimation of the Road Bridge Structure Using the Seismic Hazard map for BCM in Hokkaido, Japan

ANALYTIC STUDIES OF THE MAXIMUM DISPLACEMENTS OF SEISMIC ISOLATION UNDER MANY OBSERVED STRONG EARTHQUAKES

Effect of Correlations of Component Failures and Cross-connections of EDGs on Seismically Induced Core Damage of a Multi-unit Site

ESTIMATION OF INPUT SEISMIC ENERGY BY MEANS OF A NEW DEFINITION OF STRONG MOTION DURATION

Preliminary report of the 2011 off the Pacific coast of Tohoku Earthquake *

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES


Software Verification

Field Investigation and Dynamic Analysis of Damaged Structure on Pile Foundation during the 2011 off the Pacific Coast of Tohoku Earthquake

Special feature: Are its lessons being adequately applied? Follow-up on the ten-year anniversary of the Hanshin-Awaji Earthquake

Application of Capacity Spectrum Method to timber houses considering shear deformation of horizontal frames

Japan Seismic Hazard Information Station

Dynamic analysis of a reinforced concrete shear wall with strain rate effect. Synopsis. Introduction

EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE

PILE FOUNDATION RESPONSE DUE TO SOIL LATERAL SPREADING DURING HYOGO-KEN NANBU EARTHQUAKE

PEAK GROUND MOTION CHARACTERISTICS OF 1995 KOBE EARTHQUAKE AND AN EXTRACTED SIMPLE EVALUATION METHOD

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

Estimation of Seismic Shutoff of Intelligent Gas Meters in the Tokyo Metropolitan Area

SITE EFFECTS IN HIROSHIMA PREFECTURE, JAPAN DURING THE 2001 GEIYO EARTHQUAKE OF MARCH 24, 2001

RELATIONSHIP BETWEEN DAMAGE RATIO OF EXPRESSWAY EMBANKMENT AND SEISMIC INTENSITY IN THE 2004 MID-NIIGATA EARTHQUAKE

Effects of Surface Geology on Seismic Motion

A Seismic Simulation Technology Contributed to Preventing Earthquake Disaster

On The Ultimate Strength of RC Shear Wall under Multi-Axes Seismic Loading Condition

4 Associate Professor, DPRI, Kyoto University, Uji, Japan

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

Exploring the feasibility of on-site earthquake early warning using close-in records of the 2007 Noto Hanto earthquake

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings


Structural behavior of a high-rise RC structure under vertical earthquake motion

New Prediction Formula of Fourier Spectra Based on Separation Method of Source, Path, and Site Effects Applied to the Observed Data in Japan

STRONG MOTION PREDICTION ON ROCK SURFACE BY SUPERPOSED EVOLUTIONARY SPECTRA

Effects of Surface Geology on Seismic Motion

MODELING OF HIGH-FREQUENCY WAVE RADIATION PROCESS ON THE FAULT PLANE FROM THE ENVELOPE FITTING OF ACCELERATION RECORDS

Case Study On The Soft-First-Story Buildings Strengthened By Confined Concrete Columns

NON-LINEAR SEISMIC RESPNSE OF A PWR-TYPE REACTOR BUILDING SIMULATED BY A 3-D FEM MODEL

EFFECT OF RANDOM PARAMETERS IN SEMI-EMPIRICAL METHOD ON THE RESULTS OF GROUND MOTION PREDICTIONS

Study on acceleration response spectra for seismic design based on observed records in Hokkaido, JAPAN

RE-EVALUATION OF NONLINEAR SITE RESPONSE DURING THE 1964 NIIGATA EARTHQUAKE USING THE STRONG MOTION RECORDS AT KAWAGISHI-CHO, NIIGATA CITY

Ground Motions with Static Displacement Derived from Strong-motion Accelerogram Records by a New Baseline Correction Method

Advanced School on Direct and Inverse Problems of Seismology

GROUND MOTION SPECTRAL INTENSITY PREDICTION WITH STOCHASTIC GREEN S FUNCTION METHOD FOR HYPOTHETICAL GREAT EARTHQUAKES ALONG THE NANKAI TROUGH, JAPAN

Effects of Surface Geology on Seismic Motion

Frequency-dependent Strong Motion Duration Using Total Threshold Intervals of Velocity Response Envelope

CHARACTERISTICS OF STRONG GROUND MOTION FROM THE 2011 GIGANTIC TOHOKU, JAPAN EARTHQUAKE

Long-period Ground Motion Characteristics of the Osaka Sedimentary Basin during the 2011 Great Tohoku Earthquake

Synopses of Master Papers Bulletin of IISEE, 47, 73-78, 2013

STATIC AND DYNAMIC LOADING TESTS OF BRACKET COMPLEXES USED IN TRADITIONAL TIMBER STRUCTURES IN JAPAN

Title. Author(s)T. MIZUTANI; Y. NARAZAKI; Y. FUJINO. Issue Date Doc URL. Type. Note. File Information

Evaluating the effects of near-field earthquakes on the behavior of moment resisting frames

TRI-AXIAL SHAKE TABLE TEST ON THE THINNED WALL PIPING MODEL AND DAMAGE DETECTION BEFORE FAILURE

(c) (a) (b) EFFECTS OF LOCAL SITE AMPLIFICATION ON DAMAGE TO WOODEN HOUSES

Some Problems Related to Empirical Predictions of Strong Motion

Simulation of Nonlinear Behavior of Wall-Frame Structure during Earthquakes

SPATIAL DISTRIBUTION OF STRONG GROUND MOTION CONSIDERING ASPERITY AND DIRECTIVITY OF FAULT

MULTI-DIMENSIONAL VS-PROFILING WITH MICROTREMOR H/V AND ARRAY TECHNIQUES

Preliminary Investigation of Damage to Near Fault Buildings of the 1999 Chi-Chi Earthquake

SEISMIC HAZARD AND DESIGN BY USING ENERGY FLUX

A SPECTRAL ATTENUATION MODEL FOR JAPAN USING DIGITAL STRONG MOTION RECORDS OF JMA87 TYPE

STUDY ON APPLICABILITY OF SEMI-ACTIVE VARIABLE DAMPING CONTROL ON BRIDGE STRUCTURES UNDER THE LARGE EARTHQUAKE MOTION

2011/3/11 14:46, Depth 24km, M9.0 (JMA)

Analysis of Ignitions Following 2011 Tohoku Earthquake Using Kawasumi Model DRAFT

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

STRONG MOTION RECORDS FROM THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE

PROBABILISTIC PERFORMANCE-BASED SEISMIC DEMAND MODEL FOR R/C FRAME BUILDINGS

Estimation of Damage Ratios of Wooden Houses and Water Distribution Pipelines in an Earthquake Scenario for the Tokyo Metropolitan Region

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

STUDY ON MICROTREMOR CHARACTERISTICS BASED ON SIMULTANEOUS MEASUREMENTS BETWEEN BASEMENT AND SURFACE USING BOREHOLE

RESIDUAL STORY-DRIFT OF WEAK-BEAM PORTAL FRAME WITH SLIP-TYPE RESTORING FORCE CHARACTERISTICS OF COLUMN-BASE SUBJECTED TO GROUND MOTION

Transcription:

RELATIONSHIP OF SEISMIC RESPONSES AND STRENGTH INDEXES OF GROUND MOTIONS FOR NPP STRUCTURES Seckin Ozgur CITAK 1 Hiroshi KAWASE 2 and Shinya IKUTAMA 3 1 Research Engineer, Ohsaki Research Institute, Inc., Tokyo, JAPAN. 2 Professor, Safety control of urban space, Disaster Management for Safe and Secure Society, Disaster Prevention Research Institute, Kyoto University, Kyoto, JAPAN. 3 Senior Research Engineer, The Japan Atomic Power Company, Tokyo, JAPAN. Email: citak@ohsaki.co.jp, kawase@zeisei.dpri.kyoto-u.ac.jp, shinya_ikutama@japc.co.jp ABSTRACT: In this study we investigate the relationship of seismic responses of ABWR type of Nuclear Power Plant structures, represented by shear force at each floor, and strength indices of simulated ground motions such as PGA, PGV, A (the measurement parameter for Japanese Meteorological agency (JMA) seismic intensity), and PGA*PGV. Through the study we identified basic shear indices that can indicate or predict damage level that we can expect in the future without complex calculations. For this purposes Nonlinear Direct Integration Time History Analysis are performed for the ABWR Model using simulated strong motion records, and shear force responses of linear members are correlated with strength indices of ground motions in order to obtain shear indices. We found that the regression lines, especially with PGA for all floor levels can be used for the easy assessment of seismic response and could be the basic indices for the prediction of damage level of ABWR type of NPP structures. Also we were able to examine the ABWR model using acceleration data recorded during the 27 Niigata-ken Chuetsu-Oki earthquake, M=6.8, at the basement level of seven Kashiwazaki-Kariwa Nuclear Power Plant units. KEYWORDS: Nuclear Power Plant, ABWR, Damage estimation, Shear indices, Strong ground motion parameters, seismic response. 1. INTRODUCTION When earthquake occurs, the strong motion generated by the fault rupture causes damages and destructions to buildings thus harshly affecting human lives. The most crucial issue in earthquake disaster prevention of an urban area is how to reduce building damages, which inevitably leads to importance of knowing how to estimate quantitatively the damage levels that buildings would endure due to strong ground motion. Traditional quantitative expression for damage level of a structure is shear force, and recently story drift angle is also used. Also, there is a need to have an appropriate index to express strength of earthquake vibration. The most common representative indices are peak ground acceleration (PGA) and velocity (PGV), multiplication of them (PGA*PGV) and A, which is a filtered peak acceleration value used for JMA seismic intensity. There are two levels in evaluation of possible damage levels in buildings. First and the most common way is through a damage evaluation analysis of an individual building. Second way is to perform damage evolution for a whole building stock of an urban area by making use of statistical earthquake survey data and classifying buildings according to their age, height and structural type. Evaluation of seismic performance of buildings has become one of the topics of interest among researchers especially after the 1995 Kobe earthquake. However, most of them focused their research on evaluation of seismic performance of individual buildings, while only few studies were conducted on seismic performance of a building stock of urban area as a whole. For example Masuda and Kawase (22) have studied relationship

between the strength indices and damage ratio of middle-rise structures and established vulnerability functions for building models (Nagato and Kawase 24) with observed ground motions as input waves. According to the study for middle-rise structures vulnerability functions were better predictable for PGA*PGV or JMA seismic intensity than PGA or PGV. Establishing the relationship of ground motion strength indices and structural responses can be used for finding preliminary damage indices or shear indices. Our previous studies (Citak et al. 2, 26) were devoted to understanding of seismic behavior of Nuclear Power Plant (hereinafter NPP) structures, to predicting their damage level in such a way that could give us quick information on possible condition of concerned structures immediately after strong ground shaking. Here in this paper we calculated shear indices using simulated strong ground motions predicted by the Central Disaster Prevention Council of Japan for Tokai-Tonankai-Nankai Earthquake (23) as an extension to our previous studies, where recorded strong motions were used as an input force. Also, using recorded strong motion data of 27 Niigata-ken Chuetsu-Oki earthquake additional simulation analyses were carried out for an ABWR type of NPP structures. 2. OBJECTIVES AND SCOPE OF STUDY This study focuses on seismic response of NPP structures and relationship of seismic responses of NPP structures and strength indices of ground motions or ground motion parameters. Seismic parameters are represented by strength indices of ground motions such as PGA, PGV, A, PGA*PGV, and structural responses are represented by shear forces. First, numerical modeling of an ABWR type of NPP structure was carried out and its dynamic characteristics such as modes, transfer functions were analyzed. Second, simulated strong ground motions predicted by the Central Disaster Prevention Council of Japan for Tokai-Tonankai- Nankai Earthquake were used as an input force for the Nonlinear Direct Integration Time History Analysis. For the analysis the computer program SAP2 Nonlinear 9, one of the most widely used static and dynamic Finite Element Analysis software was used. Finally, the shear force responses of the linear members were correlated with the strength indices of simulated strong ground motions, and shear indices were obtained. In addition simulation analyses were carried out for Kashiwazaki-Kariwa NPP buildings. During the 27 Niigata-ken Chuetsu-Oki earthquake, M=6.8, strong ground motion accelerations were recorded at the basement level of seven Kashiwazaki-Kariwa NPP units. First unit of this power plant was built in 1985, and seventh (and the last) one built in 1997 to resist different design input acceleration levels (167gal~273gal) (Table 4). In Japan NPP structures are built on Tertiary or earlier bedrock, thus design accelerations are set to a relatively low level when compared to a surface ground acceleration level. Surprisingly, at the Niigata-ken Chuetsu-Oki earthquake event, peak ground accelerations were of average 2.3 times (3.6 times at unit 2) larger than those used for the design. Using the recorded acceleration data (Tokyo Electric Power Company 27) the ABWR model simulation analyses were conducted. Soil-structure interaction was not considered, because direct acceleration records observed at the basement floor levels were available. 3. ANALYSIS MODEL OF THE NPP (ABWR) STRUCTURE Physical properties, used in the analysis model, of NPP (ABWR) structure, were obtained from The report of nuclear power plant facilities limit characteristics evaluation method (Nuclear Power Engineering Corporations (hereinafter NUPEC) 1998). The structural NPP (ABWR) model was represented as a lumped mass-spring-damper system (Figure 1) with lumped masses at each floor level, weightless frame members, springs and dampers that represent interaction of structure with ground. In more detail, the lumped masses at floor levels (m1, m2 m16) were connected via massless bars (B1, B2 B15). The lumped masses M9 and M1 represent the foundation of the structural model. The system was joined to the ground by horizontal, vertical, and rotational springs and dampers, which represent soil structure interaction. The NPP (ABWR) Model consisted of an outer wall with joints from 1 to 8, and an inner core with joints from 11 to 16. These two

parts of the structure were rigidly connected at the floor levels. Two joints at each floor level were constrained together for all degrees of freedom. The foundation was represented by B9 at the foundation level. Figure 1 Analysis model of NPP (ABWR) structure 4. STRONG GROUND MOTIONS USED FOR DYNAMIC ANALYSIS In dynamic analysis of the NPP (ABWR) model, we used strong motions simulated by the Central Disaster Prevention Council (the work of Tokai earthquake investigation committee, Tokai earthquake measure investigation committee, and Tonankai and Nankai Earthquake investigation committee) for Tokai-Tonankai-Nankai Earthquake. The simulated strong motion data consisted of NS, EW and UD components for each 1 km mesh at the engineering bedrock of the concerned area. These waveforms were first calculated for 5 km mesh, then adjusted and interpolated by the spline function for seismic intensity values. Therefore, the real calculated waveform has been synthesized for 5 km mesh only. In the analyses we used about 5986 waves including EW and NS components of 2993 records, which consisted of randomly chosen 3 records of 1-4 gal level and of all records, which have acceleration levels of more than 4 Gal. The records are summarized in Table 1 and PGA distribution for the concerned area is shown in Figure 2. Figure 2 Peak Ground Acceleration distribution for selected data (Gal (cm/sec 2 ))

Table 1 Analyzed data Prefecture Points Maximum PGA(Gal) Maximum PGV(cm/s) 1 Wakayama 1263 966.7 12.3 2 Tokushima 585 533.9 86.4 3 Kochi 1155 815.2 13. Total 2993 5. DETERMINATION OF GROUND MOTION PARAMETERS The correlation between shear responses of the NPP (ABWR) structure and the seismic indexes were examined. Seismic indexes were determined by the following methods of calculation. PGA (maximum ground motion acceleration) is an assumed value of the maximum absolute acceleration value of a strong ground motion record. Before calculating this seismic index, the records are baseline corrected and long period vibrations filtered by using BUTTERWOTH high pass filter. PGV is the maximum absolute value from velocity waveform, which is obtained by integrating acceleration record. PGA*PGV is the value obtained by multiplying PGA and PGV (not in time domain). A is a measurement parameter of the JMA seismic intensity (Earthquake Research Committee 1998). The value of A is an index that used to calculate seismic intensity by Equation (1). It is also called strength of the earthquake movement (Shabestari and Yamazaki 1998). I = 2 log( A ) +.7 (1) Here, I The JMA seismic intensity; A - Maximum value of a, which satisfies w ( t a) dt. 3 (the range of integration is assumed to be the time duration that strong shaking continues); t - Time (sec); a parameter related to the strong ground motion (cm/sec 2 ); w( t a) - Parameter, which depends on the following relations: v ( t) < a ------ w ( t a) = v( t) a ------ w ( t a) = 1 Where, v(t) is a vector-combined acceleration of three components at each time interval t filtered by a frequency-domain filter defined in Table 2. Table 2 Types of Filter and its formula Filter Type Calculation formula Filter for effect at cycle (1/f) 1/2 High-cut Filter (1+.694X 2 +.241X 4 +.557X 6 +.9664X 8 +.134X 1 +.155X 12 ) -1/2 Low-cut Filter (1-exp (-(f/.5) 3 )) 1/2 f - frequency of the earthquake motion (Hz); X= f / f c (f c =1 H z ), f =.5 H z 6. ANALYSES RESULTS The purpose of the study was to examine the relationship between the responses of the NPP structure and the strength indices of ground motions. Direct integration non-linear time history analysis (Chopra 1995) (Wilson 22) was adopted with 5% of model damping. The total of 5986 simulated acceleration data (see Table 1) were used as an input force for the dynamic analysis. As for the analysis results shear forces for each individual

member were obtained and plotted against ground motion strength indices. Also linear regression line passing through the coordinate system point were drawn (Figure 3 for PGA and A, Figure 4 for PGV and PGA*PGV). Table 3 summarizes the results represented in the graphs. From the prospect of predicting building damage for a certain level earthquake, better correlation would indicate a better adequacy of a particular strength index for its use in damage estimation. Table 3 NPP (ABWR) Model Shear indices and Regression line coefficients R 2 Floor No PGA A PGV PGA*PGV (Member No) Shear Index R 2 Shear Index R 2 Shear Index R 2 Shear Index R 2 Floor8 (B1) 11.625.789 17.26.531 96.816.78 71.36x.428.7 Floor7 (B2) 27.833.791 41.312.527 231.738.93 164.92x.431.71 Floor6 (B3) 44.242.798 65.661.536 368.377.11 253.986x.434.76 Floor5 (B4) 65.27.84 96.825.55 543.433.129 366.996x.436.715 Floor4 (B5) 77.932.81 115.75.558 65.122.146 43.529x.438.723 Floor3 (B6) 13.763.818 154.15.569 867.36.175 551.529x.442.737 Floor2 (B7) 86.181.83 128.129.589 721.874.211 437.574x.447.756 Floor1 (B8) 55.397.837 82.552.621 465.53.242 274.512x.45.78 Floor6 (B1) 15.692.86 23.33.551 13.796.128 83.35x.437.718 Floor5 (B11) 3.83.816 45.753.565 257.64.156 167.496x.44.73 Floor4 (B12) 38.829.822 57.675.571 324.29.173 25.366x.443.737 Floor3 (B13) 44.81.833 66.547.582 374.616.197 226.297x.447.751 Floor2 (B14) 37.85.837 55.158.598 31.936.222 184.482x.449.766 Floor1 (B15) 37.173.837 55.435.629 312.618.246 184.78x.45.785 Average.816.57.165.736 It can be seen from Table 3, where each strong ground indices are presented for each floor level with its correlation coefficient for all analyzed simulated ground motions, shear responses have good correlation (R 2 =.789-.837) with PGA for all floors. On the other hand, it is clear that the strength index PGV does not show good correlation with shear force for any floor (R 2 =.78-.246). A, which is max of filtered acceleration that used to calculate JMA intensity, show considerably good correlation (R 2 =.527-.629) with shear responses. It shall be pointed out that index PGA*PGV did have bad linear correlation, but situation improved greatly (R 2 =.7-.785) when the correlation was assumed to be nonlinear (i.e., parabolic) as it can be clearly seen in Figure 4. 7. SIMULATION ANALYSES USING OBSERVED STRONG GROUND MOTION DATA Simulation analyses were carried out for the ABWR building of Kashiwazaki Kariwa NPP, which experienced M=6.8 Niigata-ken Chuetsu-Oki Earthquake in 27. During this earthquake acceleration exceeding up to 3.6 times of design acceleration level was recorded. Table 4 gives brief information on the NPP buildings and the observed strong motions. Buildings No.6 and No.7 are ABWR type structures. Strong motions were recorded at the basement level and an upper level of the buildings. The upper level corresponds to M4-M12 floor of our model. Figure 5 shows spectral ratios calculated using the recorded and simulated acceleration data. The spectral ratio (M4-M12/M9) of our model is close to those calculated from the recorded data, especially for the building No.7 (EW-direction). Since the strong motions were recorded at the basement floor, springs and dampers representing soil-structure interaction can be omitted. Table 5 presents maximum shear forces and story drift angle results obtained from the analyses of the simplified ABWR model (with soil-structure interaction omitted). The maximum story drift angle is 1/2 at the Floor 4 of the building No.6 (EW-direction), which shows that the relative displacements are still in a reasonable range, even the recorded PGA levels exceeded the design PGA value.

15 1 5 B1 y = 11.625x R 2 =.7892 15 1 5 B1 y = 17.26x R 2 =.5231 PGA ( gal ) 2 4 6 8 1 Ao 1 2 3 4 5 6 7 3 2 1 B2 y = 27.833x R 2 =.791 PGA ( gal ) 2 4 6 8 1 B2 3 2 y = 41.312x 1 R 2 =.527 Ao 1 2 3 4 5 6 7 2 15 1 5 B1 y = 15.692x R 2 =.86 PGA ( gal ) 2 4 6 8 1 6 4 2 B3 y = 44.242x R 2 =.798 PGA ( gal ) 2 4 6 8 1 B1 2 15 1 y = 23.33x 5 R 2 =.551 Ao 1 2 3 4 5 6 7 B3 6 4 2 y = 65.661x R 2 =.536 Ao 1 2 3 4 5 6 7 4 3 2 1 B11 y = 3.83x R 2 =.816 PGA ( gal ) 2 4 6 8 1 8 6 4 2 B4 y = 65.27x R 2 =.84 PGA ( gal ) 2 4 6 8 1 B11 4 3 2 y = 45.753x 1 R 2 =.565 Ao 1 2 3 4 5 6 7 B4 8 6 4 y = 96.825x 2 R 2 =.55 Ao 1 2 3 4 5 6 7 4 3 2 1 B12 y = 38.829x R 2 =.822 PGA ( gal ) 2 4 6 8 1 1 5 B5 y = 77.932x R 2 =.81 PGA ( gal ) 2 4 6 8 1 B12 4 3 2 y = 57.675x 1 R 2 =.571 Ao 1 2 3 4 5 6 7 B5 1 5 y = 115.75x R 2 =.558 Ao 1 2 3 4 5 6 7 6 4 2 B13 y = 44.81x R 2 =.833 PGA ( gal ) 2 4 6 8 1 15 1 5 B6 y = 13.763x R 2 =.818 PGA ( gal ) 2 4 6 8 1 B13 6 4 y = 66.547x 2 R 2 =.582 Ao 1 2 3 4 5 6 7 B6 15 1 5 y = 154.15x R 2 =.569 Ao) 1 2 3 4 5 6 7 6 4 2 B14 y = 37.85x R 2 =.837 PGA ( gal ) 2 4 6 8 1 1 5 B7 y = 86.181x R 2 =.83 PGA ( gal ) 2 4 6 8 1 B14 6 4 2 y = 55.158x R 2 =.598 Ao 1 2 3 4 5 6 7 B7 1 5 y = 128.129x R 2 =.589 Ao 1 2 3 4 5 6 7 6 4 2 B15 y = 37.173x R 2 =.837 PGA ( gal ) 2 4 6 8 1 8 6 4 2 B8 y = 55.397x R 2 =.837 PGA ( gal ) 2 4 6 8 1 B15 6 4 2 y = 55.435x R 2 =.629 Ao 1 2 3 4 5 6 7 B8 8 6 4 y = 82.552x 2 R 2 =.621 Ao 1 2 3 4 5 6 7 Figure 3 NPP (ABWR) Model Shear Force and PGA (left), A (right) Correlation Graphs 15 1 5 B1 y = 96.816x R 2 =.781 15 1 5 B1 y = 71.36x.4282 R 2 =.73 PGV ( cm/s ) 5 1 15 Max(acc)*Max(vel) 4 8 12 3 2 1 B2 y = 231.738x R 2 =.93 3 2 1 B2 y = 164.92x.431 R 2 =.71 PGV ( cm/s ) 5 1 15 Max(acc)*Max(vel) 4 8 12 2 15 1 5 B1 y = 13.796x R 2 =.128 PGV ( cm/s ) 5 1 15 6 4 2 B3 y = 368.377x R 2 =.11 PGV ( cm/s ) 5 1 15 2 15 1 5 B1 y = 88.35x.437 R 2 =.718 Max(acc)*Max(vel) 4 8 12 6 4 2 B3 y = 253.986x.434 R 2 =.76 Max(acc)*Max(vel) 4 8 12 4 3 2 1 B11 y = 257.64x R 2 =.156 PGV ( cm/s ) 5 1 15 8 6 4 2 B4 y = 543.433x R 2 =.129 PGV ( cm/s ) 5 1 15 4 3 2 1 B11 y = 167.496x.44 R 2 =.73 Max(acc)*Max(vel) 4 8 12 Shear Force (t) 8 6 4 2 B4 y = 366.996x.436 R 2 =.715 Max(acc)*Max(vel) 4 8 12 4 3 2 1 B12 y = 324.29x R 2 =.173 PGV ( cm/s ) 5 1 15 1 5 B5 y = 65.122x R 2 =.146 PGV ( cm/s ) 5 1 15 4 3 2 1 B12 y = 25.366x.443 R 2 =.737 Max(acc)*Max(vel) 4 8 12 1 5 B5 y = 43.529x.438 R 2 =.723 Max(acc)*Max(vel) 4 8 12 6 4 2 B13 y = 374.616x R 2 =.197 PGV ( cm/s ) 5 1 15 15 1 5 B6 y = 867.36x R 2 =.175 PGV ( cm/s ) 5 1 15 6 4 2 B13 y = 226.297x.447 R 2 =.751 Max(acc)*Max(vel) 4 8 12 15 1 5 B6 y = 551.529x.442 R 2 =.737 Max(acc)*Max(vel) 4 8 12 6 4 2 B14 y = 31.936x R 2 =.222 PGV ( cm/s ) 5 1 15 1 5 B7 y = 721.874x R 2 =.211 PGV ( cm/s ) 5 1 15 6 4 2 B14 y = 184.482x.449 R 2 =.766 Max(acc)*Max(vel) 4 8 12 1 5 B7 y = 437.574x.447 R 2 =.756 Max(acc)*Max(vel) 4 8 12 6 4 2 B15 y = 312.618x R 2 =.246 PGV ( cm/s ) 5 1 15 8 6 4 2 B8 y = 465.53x R 2 =.242 PGV ( cm/s ) 5 1 15 6 4 2 B15 y = 184.78x.45 R 2 =.785 Max(acc)*Max(vel) 4 8 12 8 6 4 2 B8 y = 274.512x.45 R 2 =.78 Max(acc)*Max(vel) 4 8 12 Figure 4 NPP (ABWR) Model Shear Force and PGV (left), PGA*PGV (right) Correlation Graphs

Table 4 Design and observed acceleration values at Kashiwazaki Kariwa NPP (TEPCO 27) Unit Structure Construction Design Acc.*(Gal) Observed Acc. (Gal) No Type year NS EW UD NS EW UD 1 BWR 1985 274 273 235 311 68 48 2 BWR 199 167 167 235 34 66 282 3 BWR 1993 192 193 235 38 384 311 4 BWR 1994 193 194 235 31 492 337 5 BWR 199 249 254 235 277 442 25 6 ABWR 1996 263 235 322 271 322 488 7 ABWR 1997 263 263 235 267 356 355 * Peak acceleration at the foundation level calculated considering soil amplification effect for NS and EW directions, acceleration values for UD direction, however, estimated from static design. 1 Spectral Ratio KK-NPP-No6-NS KK-NPP-No6-EW KK-NPP-No7-NS KK-NPP-No7-EW Analysis Model M4-M12/M9 1.1.1 1 1 1 Frequency (Hz) Figure 5 Spectral Ratios of No.6, No.7 and NPP (ABWR) Model Table 5 Maximum shear force responses and story drift angle values for each floor as analysis results of recorded acceleration data at No.6 and No.7 of Kashiwazaki Kariwa NPP Floor No Floor h. (cm) No6-NS No6-EW No7-NS No7-EW Drift Drift Drift B1-15 B1-8 Angle B1-15 B1-8 Angle B1-15 B1-8 Angle B1-15 B1-8 Drift Angle Floor8 115 5566.26 751.37 5343.26 3978.17 Floor7 65 1362.27 18511.39 12347.26 974.19 Floor6 82 719 19723.27 1199 384.41 6491 18648.25 491 13847.19 Floor5 54 12834 2822.32 217 44216.49 1249 26616.3 9395 2383.23 Floor4 58 15476 3364.32 24936 5237.5 14877 31326.3 11564 2468.21 Floor3 75 178 4225.29 27657 67748.47 16926 4834.28 13599 312.21 Floor2 65 23 45512.26 31919 72324.41 19836 44284.25 1659 3536.2 Floor1 65 28747 4164.2 45164 6538.32 2848 4977.2 23417 33497.16

8. CONCLUSION In general, it is difficult to predict or explain expected building damage using only one particular strength index. PGA is relatively the best index to predict the damage level of the structure. A, though has complicated calculation method, can be the second best index for damage prediction calculations. As for PGA*PGV, correlation coefficient values are between those of PGA and A, when correlation assumed to be nonlinear. PGV did not show good correlation with shear force, therefore can not be considered as a reliable index in the damage calculations. Using shear indices, PGA, A as well as PGA*PGV we can predict damage levels of an ABWR type of Nuclear Power Plant (NPP) buildings immediately after an earthquake, without any complex calculations. Also, a simple ABWR model was constructed for simulation analyses using records of 27 Niigata Chuetsu-Oki Earthquake. Soil-structure interaction was not considered, because acceleration records observed at the basement floor levels were available for. The maximum story drift angle was found to be 1/2 at the Floor 4 of the building No.6 (EW-direction), which shows that the relative displacements are still in a reasonable range, even the recorded PGA levels exceeded the design PGA values. ACKNOWLEDGEMENT We appreciate all institutions shown in the reference for providing us strong motion data as well as building data. REFERENCES Masuda, A., Kawase, H. (22). Study on construction of vulnerability function by earthquake response analysis for reinforced concrete buildings. J. of Structural and Construction Eng., Trans. of AIJ. No.558, 11-17. Nagato, K., Kawase, H. (24). Damage Evaluation Models of Reinforced Concrete Buildings Based on the Damage Statistics and Simulated Strong Motions During the 1995 Hyogo-ken Nanbu Earthquake. Earthquake Engineering and Structural Dynamics. Vol.33, No.6, 755-774. Citak, S., Kawase H., Fushimi M., Ikutama S. (24). Relationship of seismic responses and strength indexes of ground motions for a large-scale rigid structure. Architectural Institute of Japan, Hokkaido annual conference. 955-956. Seckin Ozgur CITAK, Hiroshi KAWASE, Shinya IKUTAMA. (26). Relationship of seismic responses and strength indexes of ground motions for a Large-Scale Rigid Structures. 1 st ECEES First European Conference on Earthquake Engineering and Seismology, Geneva, Switzerland, 3-8 September 26. Paper Number: 718. Central Disaster Prevention Council (23). Ground motion acceleration data of Simulated Tokai Tonankai Nankai Earthquake. Tokyo Electric Power Company (27). Acceleration data recorded at Kashiwazaki-Kariwa Nuclear Power Station during July 16, 27 Niigata-Chuetsu-Oki Earthquake (Data CD No.23) Nuclear Power Engineering Corporation (NUPEC) (1998). The report of nuclear power plant facilities limit characteristics evaluation method. Earthquake Research Committee (1998). Seismic activity in Japan-Regional perspectives on the characteristics of destructive earthquakes-(excerpt). http://www.hp139.jishin.go.jp/eqchreng/eqchrfrm.htm Shabestari, K., T., Yamazaki, F. (1998). Attenuation Relationship of JMA Seismic Intensity using Recent JMA Records. Proceedings of the 1th. Earthquake Engineering Symposium, Vol. 1, pp. 529-534. Chopra, A. (1995). Dynamics of Structures. Theory and Applications to Earthquake Engineering. Prentice-Hall. Wilson, E.L. (22) Three Dimensional Static And Dynamic Analysis Of Structures. Computers and Structures Inc. Berkeley, California. Tokyo Electric Power Company (TEPCO) (27).The report on the analysis of strong ground motion data recorded at Kashiwazaki-Kariwa Nuclear Power Plant during 27 Niigata-Chuetsu-Oki Earthquake. http://www.tepco.co.jp/cc/press/betu7_j/images/773d.pdf