Report of Test LLIA

Similar documents
Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA R02*

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400

LM-79 Report TEST REPORT NO.M037D

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM-79 Report TEST REPORT NO. L523A

LightLab I N T E R N A T I O N A L

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cat# LED Linear High Bay 100W

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Suxess Inc., dba LUX Dynamics LED-LHB-2-UNV HO LADC

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Morris Products 53 Carey Road, Queensbury, NY 12804

Lighting Sciences

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

LightLab I N T E R N A T I O N A L

Transcription:

eport of Test LLIA000858-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 14313 lm 107.5 W 133.1 lm/w PEPAED FO : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742, USA Page 1 of 7

Test eport No. LLIA000858-002 Legend: C0-Solid, C45-Dashed, C90-Grey (cd) INTENSITY SUMMAY (cd) C-Plane Flux Gamma C0 C22.5 C45 C67.5 C90 (lm) 90 0.0 5321 5321 5321 5321 5321 5.0 5265 5292 5302 5298 5282 502 10.0 5179 5204 5213 5209 5193 15.0 5037 5062 5068 5063 5048 1426 20.0 4844 4868 4871 4865 4850 25.0 4606 4626 4627 4620 4606 2128 2000 30.0 4327 4345 4343 4335 4322 35.0 4014 4029 4025 4015 4004 2513 60 40.0 3673 3683 3678 3667 3658 45.0 3310 3316 3310 3299 3292 2550 50.0 2928 2931 2924 2914 2909 55.0 2531 2531 2525 2517 2513 2256 4000 60.0 2126 2124 2119 2111 2108 65.0 1717 1714 1710 1703 1701 1691 70.0 1312 1309 1305 1299 1297 75.0 922 920 917 911 910 971 80.0 561 560 557 553 551 85.0 243 242 241 238 238 275 30 90.0 7 8 10 12 12 6000 (Two plane symmetry) C0-C90 ZONAL FLUX AND PECENTAGES AVEAGE LUMINANCE (cd / m^2) Zone Flux (lm) % Lamp % Luminaire Gamma C0 C45 C90 0-30 4056 N / A 28.3 45.0 28022 28022 27872 0-40 6569 N / A 45.9 55.0 26422 26361 26227 0-60 11375 N / A 79.5 65.0 24324 24222 24092 0-90 14313 N / A 100.0 75.0 21335 21204 21054 40-90 7743 N / A 54.1 85.0 16673 16522 16323 60-90 2938 N / A 20.5 90-180 1 N / A 0.0 0-180 14313 N / A 100.0 Total Light Output = 14,313 lm Signed: Spacing Criterion: 0-180 1.2 Spacing Criterion: 90-270 1.2 Authorized Signatory Date of test 28-Aug-2017 Date of report 29-Aug-2017 Page 2 of 7

Test eport No. LLIA000858-002 Intensity data (cd) C-Plane Gamma C0 C22.5 C45 C67.5 C90 0.0 5321 5321 5321 5321 5321 2.5 5287 5314 5324 5320 5305 5.0 5265 5292 5302 5298 5282 7.5 5229 5255 5264 5261 5245 10.0 5179 5204 5213 5209 5193 12.5 5115 5140 5147 5143 5127 15.0 5037 5062 5068 5063 5048 17.5 4947 4971 4976 4970 4955 20.0 4844 4868 4871 4865 4850 22.5 4730 4752 4755 4748 4734 25.0 4606 4626 4627 4620 4606 27.5 4471 4491 4490 4482 4469 30.0 4327 4345 4343 4335 4322 32.5 4174 4190 4188 4178 4166 35.0 4014 4029 4025 4015 4004 37.5 3846 3859 3854 3844 3834 40.0 3673 3683 3678 3667 3658 42.5 3494 3502 3496 3486 3477 45.0 3310 3316 3310 3299 3292 47.5 3120 3125 3119 3108 3102 50.0 2928 2931 2924 2914 2909 52.5 2731 2733 2726 2717 2712 55.0 2531 2531 2525 2517 2513 57.5 2330 2329 2323 2315 2311 60.0 2126 2124 2119 2111 2108 62.5 1921 1919 1914 1907 1904 65.0 1717 1714 1710 1703 1701 67.5 1513 1511 1506 1500 1498 70.0 1312 1309 1305 1299 1297 72.5 1115 1112 1108 1103 1102 75.0 922 920 917 911 910 77.5 737 735 732 727 726 80.0 561 560 557 553 551 82.5 396 395 392 389 387 85.0 243 242 241 238 238 87.5 106 106 106 106 105 90.0 7 8 10 12 12 Page 3 of 7

Test eport No. LLIA000858-002 Intensity data (cd) C-Plane Gamma C0 C22.5 C45 C67.5 C90 90.0 7 8 10 12 12 92.5 0 0 0 0 0 95.0 0 0 0 0 0 97.5 0 0 0 0 0 100.0 0 0 0 0 0 102.5 0 0 0 0 0 105.0 0 0 0 0 0 107.5 0 0 0 0 0 110.0 0 0 0 0 0 112.5 0 0 0 0 0 115.0 0 0 0 0 0 117.5 0 0 0 0 0 120.0 0 0 0 0 0 122.5 0 0 0 0 0 125.0 0 0 0 0 0 127.5 0 0 0 0 0 130.0 0 0 0 0 0 132.5 0 0 0 0 0 135.0 0 0 0 0 0 137.5 0 0 0 0 0 140.0 0 0 0 0 0 142.5 0 0 0 0 0 145.0 0 0 0 0 0 147.5 0 0 0 0 0 150.0 0 0 0 0 0 152.5 0 0 0 0 0 155.0 0 0 0 0 0 157.5 0 0 0 0 0 160.0 0 0 0 0 0 162.5 0 0 0 0 0 165.0 0 0 0 0 0 167.5 0 0 0 0 0 170.0 0 0 0 0 0 172.5 0 0 0 0 0 175.0 0 0 0 0 0 177.5 0 0 0 0 0 180.0 0 0 0 0 0 Page 4 of 7

Test Number: LLIA000858 002 Catalog Number: F LHB110/50K/F 87 One Arcata Electronics, Inc. SL 100 I2350 120 277 W D1 S LED driver Coefficients Of Utilization Zonal Cavity Method Effective Floor Cavity eflectance 0.20 C 80 70 50 30 10 0 W 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84 2 99 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 70 3 90 80 72 65 88 78 71 65 75 69 63 72 67 62 70 65 61 59 4 83 71 62 55 80 69 61 55 67 60 54 65 58 53 62 57 53 51 5 76 63 54 48 74 62 54 47 60 53 47 58 52 46 56 51 46 44 6 70 57 48 42 68 56 48 42 54 47 41 53 46 41 51 45 40 38 7 65 52 43 37 64 51 43 37 49 42 37 48 41 36 47 41 36 34 8 61 47 39 33 59 47 39 33 45 38 33 44 37 32 43 37 32 30 9 57 43 35 30 55 43 35 30 42 35 29 41 34 29 40 34 29 27 10 53 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25 For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic assumptions: 1) oom surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance. Circle of Light Plot Height(ft) Beam Width (across 50% Nadir Illum) Illuminance at Nadir (fc) 0 180 90 270 6.0 147.8 7.27 7.26 8.0 83.1 9.70 9.68 10.0 53.2 12.12 12.10 12.0 37.0 14.54 14.53 14.0 27.1 16.97 16.95 16.0 20.8 19.39 19.37 Page 5 of 7

Test eport No. LLIA000858-002 Page 6 of 7

Test eport No. LLIA000858-002 Test Distance 9.5 m Test Temperature 24.9 C Notes The laboratory has not participated in the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. Tested in accordance with the applicable sections of publications: IES LM-79-08 (Sec. 12), IES LM-16-93, IES LM-58-13, CIE 13.3:1995, CIE 15:2004, ANSI C78.377:2015, ANSI C82.77-10:2014. The luminous intensity values, and other derived quantities, contained in this report are based on the absolute data, as measured. Prorating the performance of the sample for the use of other component combinations (such as lamp / LED / Ballast / driver), or for use in different environmental conditions than that tested, may produce erroneous results. This report is free of erasures and corrections. Photometric intensity values are reported using the CIE Gamma coordinate system as defined in CIE publication number 121. This report may contain data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government. 29-Aug-17 12:44:26 EPOT program version: 3.808a Page 7 of 7