Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Similar documents
HPLC Column Material - Bulk Ware

Liquid Chromatography

Sample Preparation TLC Plates

LC Technical Information

Lab 10 Guide: Column Chromatography (Nov 3 9)

Chapter content. Reference

High Performance Liquid Chromatography

Open Column Chromatography, GC, TLC, and HPLC

RediSep Rf C18 Flash Column Loading Techniques

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

LC and LC/MS Column Selection Flow Chart

Minimizing Solvent Impact on Purification of Nitrogencontaining

BGB Flash Cartridges. Ultra-pure silica-based material. High-performance spherical 30 µm C18, CN, Diol & HILIC. Pressure up to 27 bar (400 psi)

High Performance Liquid Chromatography

High Performance Liquid Chromatography

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Biochemistry. Biochemical Techniques HPLC

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Guide to Choosing and Using Polymer Reversed Phase Columns!

Bulk Silica Gels. SiliaFlash Irregular Silica Gels SiliaSphere PC Spherical Silica Gels

Basic Principles for Purification Using Supercritical Fluid Chromatography

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

M > ACN > > THF

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Chromatography. Gas Chromatography

GPC/SEC An essential tool for polymer analysis

Contents...4. Solid phase extraction...8. Sample filtration Vials and caps Liquid chromatography Thin layer chromatography...

Gel Permeation Chromatography - GPC

Chemistry 11. Unit 3 The Physical Properties and Physical Changes of Substances

FLASH CHROMATOGRAPHY

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns

Lab.2. Thin layer chromatography

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Sample Preparation. Approaches to Automation for SPE

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)


Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Hypersil BDS Columns TG 01-05

Experiment Nine Thin Layer Chromatography

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

Packings for HPLC. Packings for HPLC

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Theory and Instrumentation of GC. Chromatographic Parameters

What is Chromatography?

HPLC Praktikum Skript

Chromatography 1 of 26 Boardworks Ltd 2016

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

Analytical Chemistry

TLC. Thin Layer Chromatography. State-of-the-art TLC products. Quality Efficiency Selectivity.

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Instrumental Chemical Analysis

Method Development Kits

Chiral Flash Columns

Experiment 1: Extraction and Thin Layer Chromatography

Shodex TM ODP2 HP series columns

Polymer analysis by GPC-SEC. Technical Note. Introduction

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Bringing uhplc Performance to the Separation of Peptides

SGE is excited to launch a new HPLC product line under the ProteCol brand.

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

HPLC Sample Preparation

Chromatography. writing in color

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

High Performance Liquid Chromatography

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

HPLC Background Chem 250 F 2008 Page 1 of 24

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

for Acclaim Mixed-Mode HILIC-1 Column

penta-hilic UHPLC COLUMNS

High Pressure/Performance Liquid Chromatography (HPLC)

Page 1. Electronic Supplementary Material (ESI) for Green Chemistry This journal is The Royal Society of Chemistry 2012

Chromatography Lab # 4

Introduction to Chromatographic Separations

Strategies for the Flash Purification of Highly Polar Compounds

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Structural characterization begins with a purity check!

Lab scale isolation of compounds by Flash Chromatography

CHEMICAL SEPARATION EXPERIMENT 2

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Analytical Strategy: HS 2014 Rafael Hodel, Stefanie Jucker. Quality Control: Quantitative Nuclear Magnetic Resonance

[S016. CHROMATOGRAPHY]

Physical Separations and Chromatography

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

Chromatography Outline

Biotage 2012 Webinar series

SCPC Systems for Liquid-Liquid Extraction

Transcription:

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products for any flash and prep HPLC application. Extra features and tools ensure optimal results even for challenging separations without compromising on convenience. High Flexibility Multiple solutions for flash and prep HPLC applications Specialized Solutions Features that go beyond your expectations Maximum Convenience Development of a flash method in no time The wide range of Pure consumables cover any need: Flash cartridges Sample loader Prep HPLC columns Glass columns The consumables are available with numerous stationary phases and dimensions. Further more all are compa tible with any leading flash or prep HPLC systems on the market. Some applications require specialized equipment. Therefore BUCHI offers customized solutions: Glass columns for loading capacities 300 g Solid loader equipment resistent up to 50 bar (725 psi) 70 mm ID prep HPLC columns for large scale purifications Valuable tools make the setup of a flash purification run easier and faster: The digital tool FlashPure Scout helps to select the cartridge that best fits your needs The TLC to flash navigator software simplifies method optimization Thanks to the RFID tag on the flash cartridges, important parameters of a run get automatically transferred to the Pure system. 3

4

Pure Consumables Portfolio FlashPure FlashPure cartridges are offered in a wide range of sizes, covering different stationary phases, particle sizes and geometries. This enables the user to choose the flash cartridge which best suits his purification needs. PrepPure PrepPure HPLC columns are filled with high quality silica and enable the performance of high resolution separations. Easy scalability from 4.6 70 mm ID and phases for standard and targeted applications make PrepPure the obvious choice for best results. GlasPure When a purification has to be scaled up, GlasPure offers maximum flexibility in terms of scale and separation requirements. The glass columns are designed for sample amounts over 300 g and pressure up to 50 bar (725 psi). Sample Loader The type of sample loading on a flash cartridge or a prep HPLC column has a big impact on the final purification results. With the Pure sample loading portfolio, the chemist has the choice between several convenient options. 5

6

FlashPure For a wide range of flash applications Choose Your FlashPure Stationary Phase Ideal conditions for a successful separation result are given when the polarity of the target compound and the phases match. In case of solubility issues of the sample in the starting eluent, solid loading is an option (see page 14). Decreasing polarity Phase Silica C18 Amino Diol Alumina C18 WP (wide pores) Ideal applications High and medium polar compounds, most popular polar phase; mainly used for flash applications Low polar and unpolar compounds, most popular unpolar phase High and medium polar molecules, e.g. carbohydrates and amines Low and medium polar compounds, e.g. lipids Wide variety of molecules, e.g. acidic, basic or acid sensitive compounds Peptides Simplify method optimization using Pure Navigator software The Pure Navigator software improves efficiency and productivity by simplifying method optimization and taking the guesswork out of interpreting your TLC or HPLC scouting runs. The FlashPure TLC plates and HPLC scouting columns use the same silica type as the FlashPure ID and EcoFlex cartridges and therefore allow best results for upscaling applications. TLC Plates FlashPure EcoFlex Silica and Alumina coated Glass and aluminum backed Fluorescence indicator 20 20 cm size HPLC scouting columns Filled with FlashPure ID C18 and C18 WP silica Sizes: 4.6 mm ID, 50 / 150 / 250 mm lengths More technical information and item numbers available here: https://www.buchi.com/sites/default/files/tds_11594058_tlc_and_scouting.pdf

8

FlashPure Scout Easily find your cartridge with FlashPure Scout Choose the cartridge that best fits your needs Learn more about parameters to improve resolution Get all technical details of your FlashPure cartridge for method optimization Easily get all item numbers and a quote for selected cartridges More information about our cartridge finder: flashpurescout.buchi.com 9

FlashPure Product overview FlashPure EcoFlex RFID tagged cartridges Non RFID tagged cartridges Characteristics Silica C18 C18 WP Amino / Diol Alumina neutral / basic / acid Particle size [µm] 50 50 50 50 60 Irregular particle geometry Spherical particle geometry Pore size [Å] 55 75 55 75 92-108 92 108 50 70 Cartridge size [g] 4 3000 4 330 4 3000 4 330 8 3200 Luer lock fitting inlet Luer slip fitting outlet Luer lock with luer slip adapter fitting outlet Max. loading capacity [%] (based on silica weight) 10 10 2.5 5 4 10

FlashPure FlashPure ID FlashPure ID HP FlashPure Select 40 40 40 20 20 15 30 30 53 80 53 80 53 80 200 250 60 75 30 70 92 108 92 108 4 330 4 330 4 330 4 330 4 330 4 330 4 330 4 330 20 20 5 5 20 30 5 10 11

12

PrepPure Highest performance for prep applications Choose Your PrepPure Stationary Phase The successful separation of a target compound with prep HPLC requires a similar polarity of the target compound and the phase only when the sample is fully soluble in the starting eluent. Phase Ideal applications Starting eluent Silica C18 C18 AQ C4 High and medium polar compounds, most popular polar phase Low polar and unpolar compounds, most popular unpolar phase; most used in prep HPLC Polar to medium polar compounds in a high water environment High molecular weight compounds (> 2000 Da), such as proteins / peptides Non or mid polar organic solvents (Hexane, DCM) Water; polar organic solvents (ACN, MeOH) Water; polar organic solvents (ACN, MeOH) Water; polar organic solvents (ACN, MeOH) Specifications Phase Silica C18 C18 AQ C4 Particle size [µm] 5, 10, 15 5, 10, 15 5, 10, 15 5, 10, 15 Particle geometry spherical spherical spherical spherical Pore size [Å] 60 100 100 300 Column lengths [mm] Column ID [mm] 150, 250 4,6 70 150, 250 4,6 70 150, 250 4,6 70 150, 250 4,6 70 O SI OH O SI OH O SI O SI OH O OH O SI P H 2 O H 2 O H 2 O H 2 O Why use C18 AQ? Many polar compounds prefer highly aqueous mobile phases for solubility reasons and can be retained only with a minimal concentration of organic modifier. Standard C18 shows phase collapse and poor resolution resulting from these conditions. The polar end capping of C18 AQ allows phase stabilization and better retention of polar compounds in a highly aqueous environment. More technical information and item numbers available here: www.buchi.com/sites/default/files/tds_11594044_preppure.pdf 13

14

GlasPure Scale-up purification Flexible dimensions for any sorbent size Column ID [mm] Pressure range [bar / psi] Capacity [g] by length 100 mm 230 mm 460 mm 920 mm 15 0 50 / 725 9 20 40 80 26 0 40 / 580 25 65 130 260 36 0 30 / 435 115 235 470 49 0 20 / 290 230 460 920 70 0 15 / 218 470 940 1800 100 0 10 / 145 935 1850 3700 Estimated g of silica (40 63 µm) Protect your glass column Pre-columns minimize dead volumes and enhance the life time of the main column by trapping contaminants. Size Pressure range [bar / psi] Compatibility [mm] Small 0 50 / 725 GlasPure ID 15 49 Large 0 20 / 290 GlasPure ID 70 100 Efficient filling of glass columns A homogeneouly packed column is essential to obtaining a reliable and reproducible separation. GlasPure filling sets allow packing in a fast, safe and reproducible way. The dry filling set is ideal for filling glass columns with silica gel using compressed gas. Silica gel in the size range 25 200 µm can be packed with this method. The slurry filling set is used for wet filling and conditioning of glass columns with silica gel particles smaller than 25 µm. More technical information and item numbers available here: www.buchi.com/sites/default/files/tds_11594056_glaspure.pdf 15

Sample Loader Convenient choices Pure Sample Loops Used for liquid loading The liquid sample gets injected manually into a loop and from there it s automatically transferred on the column Available loop sizes: 2 ml, 5 ml, 10 ml Pure Solid Loader Used for external solid loading Loader can be partially filled with the sample Resistant up to 50 bar (725 psi) Connected in front of the cartridge Available loader sizes: 15 g, 40 g FlashPure EcoFlex Silica Solid Loader Used for internal solid loading Openable cartridge filled 85 % with Silica Free space for solid sample Available loader sizes: 3.5 g, 10 g, 20 g, 35 g, 70 g, 100 g, 185 g, 280 g FlashPure EcoFlex Empty Solid Loader Used for external solid loading Loader needs to be filled completely with the sample Connected in front of the cartridge Available loader sizes: 12 g, 20 g, 40 g, 80 g, 120 g 16

Different sample loading techniques Loading Technique Purification Method Procedure Pros & Cons Liquid loading is used for samples, which are sufficiently dissolved in the starting eluent (= weak solvent) Flash Prep HPLC Liquid sample (mixture of crude sample and solvent) injected via an injection valve or directly on top of the cartridge / column Fast method but with reduced resolution Solid loading is used for samples which are only soluble in strong solvents ( initial mobile phase) or to improve resolution (less band broadening and tailing effect) Flash Solid sample (mixture of crude sample & support material) placed in front of the cartridge Slower method but enhanced resolution Why add support material (e.g. silica)? The crude sample gets absorbed on the silica which allows a better transfer and distribution of the eluted compounds. The sample is also kept in place and made stationary, which is important for work with substances such as oily extracts. More technical information and item numbers available here: www.buchi.com/sites/default/files/tds_11594057_sample_loader.pdf 17

Complete your portfolio Synthesis Work-up Evaporation We offer dedicated solutions for laboratory rotary evaporation for R&D or quality control. Based on our experience and knowledge, we offer tailor-made solutions to cover a wide range of distinct needs and achieve highest convenience. Chromatography Whatever the complexity or the scale of your purification process is, the BUCHI preparative chromatography systems are designed to fulfill your changing needs. Together with a broad range of high performance flash chromatography columns, we provide you the optimized solution suited to your purification workflow. 18

Analysis Freeze Drying Our first laboratory Freeze Dryer with Infinite- Technology and Infinite-Control. Applications range from R&D to quality control within a broad spectrum of market segments. Our solutions stand out by their efficiency and practical capability. Melting Point To determine your melting and boiling points with high accuracy, visual or automatic determination and optional qualification packages meeting highest regulatory standards. 19

Core messages to our customers BUCHI creates added value «Quality in your hands» is the guiding principle that shapes our philosophy and our actions. It challenges us to provide outstanding services that are precisely tailored to your needs. This means that we must stay in close contact with our customers. That is why we keep in touch and continue to work very hard to understand you and your business even better. We help you by providing high-quality products, systems, solutions, applications and services that offer you added value. This allows you to focus entirely on your processes and your work. Competent We have the technological expertise and decades of experience needed to provide competent support and work with you to continually improve our services. Reliable We guarantee the quality and functionality of our equipment and will continue to help you quickly and efficiently whenever something does not operate to your satisfaction. Safe By collaborating closely with you, we do everything in our power to make our products, systems, solutions, applications and services as safe as possible for people and the environment. Cost-effective We strive to create a high level of economic benefit and maximum added value for you. Global As an international family-owned business with own subsidiaries and qualified distributors, we have a presence wherever you are located. BÜCHI Labortechnik AG CH 9230 Flawil T +41 71 394 63 63 F +41 71 394 64 64 info@buchi.com Easy We support you by providing carefully designed solutions as well as instruments and systems that are easy to operate. Sustainable We support environmentally friendly processes and manufacture products that have a long service life. We utilize advanced technologies to leave the smallest environmental footprint possible. 11595622A en 1901 / Technical data are subject to change without notice / Quality Systems ISO 9001 The English version is the original language version and serves as basis for all translations into other languages. www.buchi.com